Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Photometric and spectroscopic gamma-ray observations of solar transient phenomena using long duration balloons

A program currently in progress to conduct extended duration spectroscopic and photometric observation of solar X-ray phenomena from balloons is described. High photometric sensitivity to weak hard X-ray bursts is attained using a 600 sq cm array of phoswich scintillators. High spectral resolution for stronger bursts is available from an array of planar germanium detectors. These instruments are carried in a novel balloon gondola dssigned for the 15 to 20 day float durations available through using conventional zero pressure balloons in the radiation controlled (RACOON) mode.

Pelling, M. R.↗

A long-duration balloon payload for hard X-ray and gamma-ray observations of the sun

A balloon payload designed to study the processes of energy release, particle acceleration, and heating of the active corona in hard X-ray microflares and normal flares is described. An array of liquid nitrogen-cooled germanium detectors together with large area phoswich scintillation detectors provide the highest sensitivity (about 500 sq cm) and energy resolution (not greater than 0.7 keV) ever achieved for solar hard X-ray (about 15-600 keV) measurements. These detectors were flown in February 1987 from Australia on a long duration radiation controlled balloon flight (LDBF) which provided 12 days of observations before cutdown in Brazil. The payload includes solar cells for power, pointing, and navigation sensors, a microprocessor controlled data system with VCR tape storage, and transmitters for GOES and ARGOS spacecraft. This successful flight illustrates the potential of LDBFs for solar flare studies.

Lin, R. P.↗

A high-resolution gamma-ray and hard X-ray spectrometer for solar flare observations in Max 1991

A long duration balloon flight instrument for Max 1991 designed to study the acceleration of greater than 10 MeV ions and greater than 15 keV electrons in solar flares through high resolution spectroscopy of the gamma ray lines and hard X-ray and gamma ray continuum is described. The instrument, HIREGS, consists of an array of high-purity, n-type coaxial germanium detectors (HPGe) cooled to less than 90 K and surrounded by a bismuth germanate (BGO) anticoincidence shield. It will cover the energy range 15 keV to 20 MeV with keV spectral resolution, sufficient for accurate measurement of all parameters of the expected gamma ray lines with the exception of the neutron capture deuterium line. Electrical segmentation of the HPGe detector into a thin front segment and a thick rear segment, together with pulse-shape discrimination, provides optimal dynamic range and signal-to-background characteristics for flare measurements. Neutrons and gamma rays up to approximately 0.1 to 1 GeV can be detected and identified with the combination of the HPGe detectors and rear BGO shield. The HIREGS is planned for long duration balloon flights (LDBF) for solar flare studies during Max 1991. The two exploratory LDBFs carried out at mid-latitudes in 1987 to 1988 are described, and the LDBFs in Antarctica, which could in principle provide 24 hour/day solar coverage and very long flight durations (20 to 30 days) because of minimal ballast requirements are discussed.

Lin, R. P.↗

Observational techniques for solar flare gamma-rays, hard X-rays, and neutrons

The development of new instrumentation and techniques for solar hard X-ray, gamma ray and neutron observations from spacecraft and/or balloon-borne platforms is examined. The principal accomplishments are: (1) the development of a two segment germanium detector which is near ideal for solar hard X-ray and gamma ray spectroscopy; (2) the development of long duration balloon flight techniques and associated instrumentation; and (3) the development of innovative new position sensitive detectors for hard X-ray and gamma rays.

Lin, Robert P.↗

High-resolution observations of gamma-ray line emission from SN 1987A

Observations of SN 1987A made with a balloon-borne gamma-ray spectrometer comprising an array of high-purity germanium detectors on October 29-31, 1987 are presented. High resolution data, typically 2.5 keV at 1.33 MeV, were obtained for two transists of the supernova with interspersed background data. A preliminary estimation of line flux is presented. It is found that there is evidence of dynamical broadening of the 847 keV line. It is suggested that this line may be an emission from the first excited state of Fe-56 due to the radioactive decay of Co-56 providing evidence for nucleosynthesis in the supernova.

Sandie, W. G.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 pcts. at 1332 keV. Detector efficiencies as a function of energy and corrections for self absorption in the samples were determined with calibrated sources, unactivated control samples, and calculations. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum samples, Na-22 and Be-7 were seen. Other results are presented.

Moss, C. E.↗

Gamma-ray lines from SN1987A

Results of gamma-ray observations of SN1987A conducted over a period of 800 days using balloon-borne high-resolution germanium detectors are discussed. Most of the measurements show red-shifted line centroids (about 500 km/s) and broadened profiles, contradicting the standard homogeneous and spherically symmetric models, which predict blue-shifted lines and narrower line widths. To explain this apparent contradiction, it may be necessary to invoke fragmentation and nonspherical geometries.

Teegarden, B. J.↗

Measurements of induced radioactivity in some LDEF samples

Twenty-six stainless steel trunnion samples, five aluminum end support retainer plate samples, two aluminum keel plate samples, and two titanium clips were analyzed. The shielded high purity germanium detectors used had efficiencies of 33, 54, and 80 percent at 1332 keV. Detector efficiencies as a function of energy and corrections for self-absorption in the samples were determined with calibrated sources and unactivated control samples. Several measurements were made on most samples. In the trunnion samples, Mn-54 and Co-57 were seen and limits were obtained for other isotopes. The results agree well with 1-D activation calculations for an anisotropic trapped proton model. In the aluminum and titanium samples, Na-22 was detected. Other results are presented.

Moss, C. E.↗

An observation of the Galactic center region with the HEXAGONE high resolution gamma-ray spectrometer

The Galactic center region was observed for 6 hours on May 22, 1989 from a high altitude balloon with the HEXAGONE high resolution gamma-ray spectrometer. The instrument had a 285 sq/cm array of cooled germanium detectors with an energy resolution of 2.2 keV at 511 keV and an 18 deg FWHM field of view. The 511 keV gamma-rays from electron-positron annihilation and 1809 keV gamma-rays from the radioactive decay of Al-26 were observed to have fluxes of 8.9 x 10 exp -4 and 1.9 x 10 exp -4 ph/cm-s, respectively. Continuum emission was detected from 20 to 800 keV and preliminary results have been obtained for the spectrum. Below 120 keV this is well described by power law with a slope of -2.6. In the 120-250 keV band the spectrum contains a broad linelike feature. This is interpreted as the result of Compton backscattering of about 511 keV photons from a compact source of electron-positron annihilation radiation.

Matteson, J.↗

A tunable crystal diffraction telescope for the International Space Station

A focusing gamma ray telescope is proposed for use onboard the International Space Station. It consists of a tunable crystal diffraction lens which focuses gamma rays onto a small array of germanium detectors located on an extendable boom. While the weight of such an instrument is less than 500 kg, it features an angular resolution of 15 arcsec, an energy resolution of 2 keV and a 3 sigma sensitivity of the order of 10(exp -7) photons/sq cm sec for any individual narrow line at energies of between 200 and 1300 keV. The scientific potential of such a telescope is discussed. The principles of a diffraction lens and a tunable diffraction lens are described.

VonBallmoos, P.↗

High-resolution spectral measurements of GRO J1655-40

Data from the transient gamma ray germanium detector taken during 1995 provide a limited ability to study the high resolution spectrum of the X-ray transient GRO J1655-40. During a two-day period around the peak intensity, the soft spectrum was measured and found to be consistent with a power law spectrum with photon index -3.0 +/- 0.2. No evidence was found for narrow spectral features in the 50 to 100 keV band or around 511 keV. The 3 sigma upper limit for a narrow emission line at 511 keV is 1.2 x 10(exp -2) phot/cu cm s.

intZand, J. J. M.↗

Observing gamma-ray bursts with the INTEGRAL spectrometer SPI

The spectrometer for INTEGRAL (SPI) is a germanium spectrometer with a wide field of view and will provide the International Gamma Ray Astrophysics Laboratory (INTEGRAL) mission with the opportunity of studying gamma ray bursts. Simulations carried out to assess the response of the instrument using data from real burst data as input are reported on. It is shown that, despite the angular resolution of 3 deg, it is possible to locate the direction of bursts with an accuracy of a few arcmin, while offering the high spectral resolution of the germanium detectors. It is remarked that the SPI field of view is similar to the size of the halo of bursts expected around M 31 on galactic models. The detectability of bursts with such a halo is discussed.

Skinner, G. K.↗

The INTEGRAL scatterometer SPI

The INTErnational Gamma Ray Astrophysics Laboratory (INTEGRAL) mission's onboard spectrometer, the INTEGRAL spectrometer (SPI), is described. The SPI constitutes one of the four main mission instruments. It is optimized for detailed measurements of gamma ray lines and for the mapping of diffuse sources. It combines a coded aperture mask with an array of large volume, high purity germanium detectors. The detectors make precise measurements of the gamma ray energies over the 20 keV to 8 MeV range. The instrument's characteristics are described and the Monte Carlo simulation of its performance is outlined. It will be possible to study gamma ray emission from compact objects or line profiles with a high energy resolution and a high angular resolution.

Mandrou, P.↗

Final Qualification and Early On-Orbit Performance of the HESSI Cryocooler

The High Energy Solar Spectroscopic Imager (HESSI) spacecraft was launched on February 5, 2002. It now observes the Sun with the finest angular and energy resolutions ever achieved from a few keV to hundreds of keV, using an array of nine germanium detectors operating at 75K. The spacecraft was originally scheduled for launch in July 2000, but a vibration facility mishap damaged the primary structure of the spacecraft, along with the cryocooler, This paper describes issues in the qualification of a replacement for the original flight cooler, and describes early on-orbit performance.

Boyle, R. F.↗

On-Orbit Performance of the RHESSI Cryocooler

The Ramaty High Energy Solar Spectroscopic Imager (RHESSI) spacecraft was launched on February 5,2002. With more than a year of operation on-orbit, its Sunpower M77 cryocooler continues to maintain the array of nine germanium detectors at 7% Trends have begun to emerge in cryocooler power and vibration, suggesting that the cooler's operating point is slowly changing. Possible causes are identified and discussed.

Boyle, Robert F.↗

Description of a prototype emission-transmission computed tomography imaging system

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

NASA Discipline Musculoskeletal↗

The Gamma-Ray Imager/Polarimeter for Solar Flares (GRIPS)

The balloon-borne Gamma-Ray Imager/Polarimeter for Solar flares (GRIPS) instrument will provide a near-optimal combination of high-resolution imaging, spectroscopy, and polarimetry of solar-flare gamma-ray/hard X-ray emissions from approximately 20 keV to greater than approximately 10 MeV. GRIPS will address questions raised by recent solar flare observations regarding particle acceleration and energy release, such as: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? The spectrometer/polarimeter consists of sixteen 3D position-sensitive germanium detectors (3D-GeDs), where each energy deposition is individually recorded with an energy resolution of a few keV FWHM and a spatial resolution of less than 0.1 cubic millimeter. Imaging is accomplished by a single multi-pitch rotating modulator (MPRM), a 2.5-centimeter thick tungsten alloy slit/slat grid with pitches that range quasi-continuously from 1 to 13 millimeters. The MPRM is situated 8 meters from the spectrometer to provide excellent image quality and unparalleled angular resolution at gamma-ray energies (12.5 arcsec FWHM), sufficient to separate 2.2 MeV footpoint sources for almost all flares. Polarimetry is accomplished by analyzing the anisotropy of reconstructed Compton scattering in the 3D-GeDs (i.e., as an active scatterer), with an estimated minimum detectable polarization of a few percent at 150-650 keV in an X-class flare. GRIPS is scheduled for a continental-US engineering test flight in fall 2013, followed by long or ultra-long duration balloon flights in Antarctica.

Shih, Albert Y.↗

First Flight of the Gamma-Ray Imager Polarimeter for Solar Flares (GRIPS) Instrument

The Gamma-Ray Imager/Polarimeter for Solar ares (GRIPS) instrument is a balloon-borne telescope designed to study solar-flare particle acceleration and transport. We describe GRIPS's first Antarctic long-duration flight in January 2016 and report preliminary calibration and science results. Electron and ion dynamics, particle abundances and the ambient plasma conditions in solar flares can be understood by examining hard X-ray (HXR) and gamma-ray emission (20 keV to 10 MeV). Enhanced imaging, spectroscopy and polarimetry of flare emissions in this energy range are needed to study particle acceleration and transport questions. The GRIPS instrument is specifically designed to answer questions including: What causes the spatial separation between energetic electrons producing hard X-rays and energetic ions producing gamma-ray lines? How anisotropic are the relativistic electrons, and why can they dominate in the corona? How do the compositions of accelerated and ambient material vary with space and time, and why? GRIPS's key technological improvements over the current solar state of the art at HXR/gamma-ray energies, the Reuven Ramaty High Energy Solar Spectroscopic Imager (RHESSI), include 3D position-sensitive germanium detectors (3D-GeDs) and a single-grid modulation collimator, the multi-pitch rotating modulator (MPRM). The 3D-GeDs have spectral FWHM resolution of a few hundred keV and spatial resolution less than 1cu mm. For photons that Compton scatter, usually greater or equal to 150 keV, the energy deposition sites can be tracked, providing polarization measurements as well as enhanced background reduction through Compton imaging. Each of GRIPS's detectors has 298 electrode strips read out with ASIC/FPGA electronics. In GRIPS's energy range, indirect imaging methods provide higher resolution than focusing optics or Compton imaging techniques. The MPRM grid-imaging system has a single-grid design which provides twice the throughput of a bi-grid imaging system like RHESSI. The grid is composed of 2.5 cm deep tungsten-copper slats, and quasi-continuous FWHM angular coverage from 12.5-162 arcsecs are achieved by varying the slit pitch between 1-13 mm. This angular resolution is capable of imaging the separate magnetic loop footpoint emissions in a variety of are sizes. In comparison, RHESSI's 35-arcsec resolution at similar energies makes the footpoints resolvable in only the largest ares.

Duncan, Nicole↗