Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Germanium”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Low-temperature irradiation-induced defects in p-type germanium

Besides two well-known dominant peaks, which have been earlier correlated with the single monovacancy and gallium interstitial defect, a number of small lines appear in deep level transient spectroscopy (DLTS) spectra measured in situ after particle irradiation at low temperatures in p-type germanium. Three of the most pronounced have been studied to some detail in the present investigation by combining DLTS and high-resolution Laplace DLTS. These three lines are called H70, H280 and H290, where the H refers to their hole-trap nature, and the numbers to their apparent enthalpy for hole emission relative to the valence-band edge. The H70 trap is most probably a primary defect, and its observed energy level is found to be an acceptor level. Possible defects related to these DLTS lines are discussed with special emphasis on the divacancy defect in germanium.

36 MATERIALS SCIENCE↗

Void formation in amorphous germanium due to high electronic energy deposition

The effect of high electronic energy deposition in amorphous germanium has been studied experimentally by Au irradiation with ion energies of up to 185 MeV and different angles of incidence and by molecular dynamics computer simulations. In both cases, the energy deposition leads to void formation accompanied by strong swelling of the amorphous germanium. The simulation results prove that the formation of the voids is mainly based on a shock wave mechanism and the swelling is determined by the competing processes of the formation and growth of voids on the one hand and the shrinking and annihilation of voids on the other hand. In full agreement between experiment and simulation, the amount of the swelling is a linear function of the total energy deposited into electronic processes and there exists a threshold value of the electronic energy loss per ion and depth for swelling. A comparison of the threshold values obtained by the experiment and the simulation suggests that approximately 20% of the energy deposited into electronic processes is converted into atomic motion.

36 MATERIALS SCIENCE↗

Structural modifications of low-energy heavy-ion irradiated germanium

Heavy-ion irradiation of crystalline germanium (c-Ge) results in the formation of a homogeneous amorphous germanium (a-Ge) layer at the surface. This a-Ge layer undergoes structural modification such as a strong volume expansion accompanied by drastic surface blackening with further ion irradiation. In the present paper we investigate the mechanism of this ion-induced structural modification in a-Ge basically for the irradiation with I ions (3 and 9 MeV) at room and low temperature as a function of ion fluence for the ion incidence angles of {Theta}=7 deg. and {Theta}=45 deg. For comparison, Ag- and Au-ion irradiations were performed at room temperature as a function of the ion fluence. At fluences two orders of magnitude above the amorphization threshold, morphological changes were observed for all irradiation conditions used. Over a wide range of ion fluences we demonstrate that the volume expansion is caused by the formation of voids at the surface and in the depth of the projected ion range. At high ion fluences the amorphous layer transforms into a porous structure as established by cross section and plan view electron microscopy investigations. However, the formation depth of the surface and buried voids as well as the shape and the dimension of the final porous structure depend on the ion fluence, ion species, and irradiation temperature and will be discussed in detail. The rate of the volume expansion (i.e., porous layer formation) depends linearly on the value of {epsilon}{sub n}. This clearly demonstrates that the structural changes are determined solely by the nuclear energy deposited within the amorphous phase. In addition, at high ion fluences all perpendicular ion irradiations lead to a formation of a microstructure at the surface, whereas for nonperpendicular ion irradiations a nonsaturating irreversible plastic deformation (ion hammering) without a microstructure formation is observed. For the irradiation with ion energies of several MeV, the effect of plastic deformation shows a linear dependence on the ion fluence. Based on these results, we provide an explanation for the differences in surface morphology observed for different angles of incidence of the ion beam will be discussed in detail.

36 MATERIALS SCIENCE↗

Potential for large germanium detector arrays for solar-axion searches utilizing the axio-electric effect for detection

The sensitivities of large arrays of low-background germanium detectors for solar-axion, or axionlike particle, searches are investigated in the context of several coupling scenarios. A search was made for the 14.4-keV axion branch from the M1 transition in the thermally excited {sup 57}Fe in the solar core in 80 kg d of data from the International Germanium Experiment (IGEX) Dark Matter experiment. In one scenario, the direct couplings of axions to hadrons and to electrons were assumed to be in the range of the Peccei-Quinn scale 3x10{sup 5}{<=}f{sub PQ}{<=}7x10{sup 5} GeV. This scenario is excluded by the IGEX data. In a second case, at the same Peccei-Quinn scale, coupling to photons and to electrons is suppressed. The IGEX data partially exclude this scenario depending on the degree of suppression. In the third case, the Peccei-Quinn scale for all couplings is assumed to be in the range 3x10{sup 6}{<=}f{sub PQ}{<=}7x10{sup 6} GeV. Detection rates in Ge for all three scenarios are presented for several detector arrays.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Gepta-EX: a multi-channel germanium detector for X-ray absorption fine structure

Fluorescence-mode X-ray absorption spectroscopy (XAS) at high photon energies requires detectors with high stopping power and excellent energy resolution to measure weak element-specific signals. Traditional silicon-based detectors suffer from poor efficiency above ∼20 keV, while most high-Z materials such as cadmium telluride, cadmium zinc telluride, and gallium arsenide have focused predominantly on imaging applications with limited spectroscopic resolution. In contrast, germanium combines excellent stopping power with superior intrinsic energy resolution due to its low Fano factor and favorable charge transport properties, making it ideal for high-resolution spectroscopy in the 15 keV to 100 keV range. To address these requirements, we report on the development, fabrication, and performance evaluation of Gepta-EX, a compact multi-channel high-purity germanium (HPGe) detector system for fluorescence-mode XAS. The Gepta-EX system features a monolithic seven-channel HPGe pixel array integrated with low-noise CUBE charge-sensitive preamplifiers, housed within a thermally isolated compact cryostat operating near 90 K. The detector achieves energy resolutions of 218 eV at 5.9 keV (from a 55 Fe source) and 373 eV at 59.5 keV (from a 241 Am source), with uniform performance across all channels. By avoiding the escape peak interference commonly associated with silicon detectors and providing stable, high-resolution performance, Gepta-EX represents a powerful tool for high-energy X-ray spectroscopy.

36 MATERIALS SCIENCE↗

GeMini: The Next-Generation Mechanically-Cooled Germanium Spectrometer

The next-generation mechanically-cooled germanium spectrometer has been developed. GeMini (MINIature GErmanium spectrometer) has been designed to bring high-resolution gamma-ray spectroscopy to a range of demanding field environments. Intended applications include short-notice inspections, border patrol, port monitoring and emergency response, where positive nuclide identification of radioactive materials is required but power and liquid cryogen are not easily available. GeMini weighs 2.75 kg for the basic instrument and 4.5 kg for the full instrument including user interface and ruggedized hermetic packaging. It is very low power allowing it to operate for 10 hours on a single set of rechargeable batteries. This instrument employs technology adapted from the gamma-ray spectrometer currently flying on NASA's Mercury MESSENGER spacecraft. Specifically, infrared shielding techniques allow for a vast reduction of thermal load. This in turn allows for a smaller, lighter-weight design, well-suited for a hand-held instrument. Three working prototypes have been built and tested in the lab. The measured energy resolution is 3 keV fwhm at 662 keV gamma-rays. This paper will focus on the design and performance of the instrument.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Initial Field Measurements with the Multisensor Airborne Radiation Survey (MARS) High Purity Germanium (HPGe) Detector Array

Abstract: The Multi-sensor Airborne Radiation Survey (MARS) project has developed a new single cryostat detector array design for high purity germanium (HPGe) gamma ray spectrometers that achieves the high detection efficiency required for stand-off detection and actionable characterization of radiological threats. This approach is necessary since a high efficiency HPGe detector can only be built as an array due to limitations in growing large germanium crystals. The system is ruggedized and shock mounted for use in a variety of field applications. This paper reports on results from initial field measurements conducted in a truck and on two different boats.

characterization↗

Polarization of the terahertz radiation of uniaxially compressed p germanium at the electrical breakdown of a shallow acceptor impurity

The spectral and polarization investigations of spontaneous terahertz radiation under the conditions of the electrical breakdown of shallow acceptors (gallium) in germanium crystals have been reported. The radiation spectra of crystals uniaxially compressed in the [111] direction at a pressure of about 3 kbar, as well as undeformed crystals, have been measured at T = 5 K using a Fourier spectrometer with step scanning. The polarization of radiation has been estimated for transitions of holes between various states of a shallow acceptor in uniaxially compressed germanium. To identify the observed radiation lines, their experimental energies and polarizations have been compared to the respective calculated values. The spectral lines corresponding to the transitions of holes from the resonance state to the excited states of acceptors have been identified.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Formation of Porous Germanium Layers by Silver-Ion Implantation

We propose a method for the formation of porous germanium (P-Ge) layers containing silver nanoparticles by means of high-dose implantation of low-energy Ag{sup +} ions into single-crystalline germanium (c-Ge). This is demonstrated by implantation of 30-keV Ag{sup +} ions into a polished c-Ge plate to a dose of 1.5 × 10{sup 17} ion/cm{sup 2} at an ion beam-current density of 5 μA/cm{sup 2}. Examination by high-resolution scanning electron microscopy (SEM), atomic-force microscopy (AFM), X-ray diffraction (XRD), energy-dispersive X-ray (EDX) microanalysis, and reflection high-energy electron diffraction (RHEED) showed that the implantation of silver ions into c-Ge surface led to the formation of a P-Ge layer with spongy structure comprising a network of interwoven nanofibers with an average diameter of ∼10–20 nm Ag nanoparticles on the ends of fibers. It is also established that the formation of pores during Ag{sup +} ion implantation is accompanied by effective sputtering of the Ge surface.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Recommendations for a Static Cosmic Ray Shield for Enriched Germanium Detectors

This document provides a detailed study of cost and materials that could be used to shield the detector material of the international Tonne-scale germanium neutrinoless double-beta decay experiment from hadronic particles from cosmic ray showers at the Earth's surface. This work was motivated by the need for a shield that minimizes activation of the enriched germanium during storage; in particular, when the detector material is being worked on at the detector manufacturer's facility. This work considers two options for shielding the detector material from cosmic ray particles. One option is to use a pre-existing structure already located near the detector manufacturer, such as Canberra Industries in Meriden, Connecticut. The other option is to build a shield onsite at a detector manufacturer's site. This paper presents a cost and efficiency analysis of such construction.

61 RADIATION PROTECTION AND DOSIMETRY↗

Optimization of the Transport Shield for Neutrinoless Double-beta Decay Enriched Germanium

This document presents results of an investigation of the material and geometry choice for the transport shield of germanium, the active detector material used in 76Ge neutrinoless double beta decay searches. The objective of this work is to select the optimal material and geometry to minimize cosmogenic production of radioactive isotopes in the germanium material. The design of such a shield is based on the calculation of the cosmogenic production rate of isotopes that are known to cause interfering backgrounds in 76Ge neutrinoless double beta decay searches.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

US-ROK Action Sheet 34: Safeguards Application of a Hand-held Mechanically Cooled Germanium Spectrometer

This report summarizes results of Action Sheet 34 - for the cooperative efforts on the field testing and evaluation of a high-resolution, hand-held, gamma-ray spectrometer, known as SPG (Spectroscopic Planar Germanium), for safeguards application such as short notice inspections, UF6 analysis, enrichment determination, and other potential applications. The Spectroscopic Planar Germanium (SPG) has been demonstrated IAEA Physical Inventory Verification (PIV) in South Korea. This field test was a success and the feedback provided by KINAC, IAEA, and national laboratory staff was used to direct efforts to improve the instrument this year. Key points in this report include measurement results from PIV, analysis of spectra with commercially available Ortec U235 and PC-FRAM, and completion of tripod and tungsten collimator and integration of user feedback.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutron Damage in Mechanically-Cooled High-Purity Germanium Detectors for Field-Portable Prompt Gamma Neutron Activation Analysis (PGNAA) Systems

Prompt Gamma Neutron Activation (PGNAA) systems require the use of a gamma-ray spectrometer to record the gamma-ray spectrum of an object under test and allow the determination of the object’s composition. Field-portable systems, such as Idaho National Laboratory’s PINS system, have used standard liquid-nitrogen-cooled high-purity germanium (HPGe) detectors to perform this function. These detectors have performed very well in the past, but the requirement of liquid-nitrogen cooling limits their use to areas where liquid nitrogen is readily available or produced on-site. Also, having a relatively large volume of liquid nitrogen close to the detector can impact some assessments, possibly leading to a false detection of explosives or other nitrogen-containing chemical. Use of a mechanically-cooled HPGe detector is therefore very attractive for PGNAA applications where nitrogen detection is critical or where liquid-nitrogen logistics are problematic. Mechanically-cooled HPGe detectors constructed from p-type germanium, such as Ortec’s trans-SPEC, have been commercially available for several years. In order to assess whether these detectors would be suitable for use in a fielded PGNAA system, Idaho National Laboratory (INL) has been performing a number of tests of the resistance of mechanically-cooled HPGe detectors to neutron damage. These detectors have been standard commercially-available p-type HPGe detectors as well as prototype n-type HPGe detectors. These tests compare the performance of these different detector types as a function of crystal temperature and incident neutron fluence on the crystal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Cryogenic readout techniques for germanium detectors

High Purity Germanium detectors are used in many applications, from nuclear and astro-particle physics, to homeland security or environment protection. Although quite standard configurations are often used, with cryostats, charge sensitive amplifiers and analog or digital acquisition systems all commercially available, it might be the case that a few specific applications, e.g. satellites, portable devices, cryogenic physics experiments, etc. also require the development of a few additional or complementary techniques. An interesting case is for sure GERDA, the Germanium Detector Array experiment, searching for neutrino-less double beta decay of {sup 76}Ge at the Gran Sasso National Laboratory of INFN - Italy. In GERDA the entire detector array, composed of semi-coaxial and BEGe naked crystals, is operated suspended inside a cryostat filled with liquid argon, that acts not only as cooling medium and but also as an active shield, thanks to its scintillation properties. These peculiar circumstances, together with the additional requirement of a very low radioactive background from all the materials adjacent to the detectors, clearly introduce significant constraints on the design of the Ge front-end readout electronics. All the Ge readout solutions developed within the framework of the GERDA collaboration, for both Phase I and Phase II, will be briefly reviewed, with their relative strength and weakness compared together and with respect to ideal Ge readout. Finally, the digital processing techniques developed by the GERDA collaboration for energy estimation of Ge detector signals will be recalled. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of the PHDS Germanium Gamma-ray Imager (GeGI) in Facility Decontamination Assessment - 19471

As part of a site wide investigation, U.S. EPA Region 5 had to assess the nature and extent of contamination in a former radioactive source manufacturing facility. This work involved verification of the radioisotope expected, ensuring no other radioisotopes were present, and quantification of the activity and areal extent of contamination throughout the facility. The device used to support this assessment work was the Germanium Gamma-ray Imager (GeGI) manufactured by PHDS Co. of Knoxville, Tennessee. GeGI is a germanium-semiconductor imaging detector system that provides identification, location, and quantification of radioactive materials within its field of view. GeGI provides the highest fidelity radiological assay information including the best gamma-ray energy resolution and spatial localization of any existing technology, including gamma-ray energy resolution of ∼0.3% full-width half-max (FWHM) at 662 keV and angular location resolution ∼ +/-1 degree. The GeGI is a mechanically cooled, portable system well-suited to field operations. PHDS Co. also provided on-site support during assessment operations and performed subsequent data analysis. Gamma-ray spectral data and associated images were collected with GeGI in six primary areas of the facility having significant residual contamination. A total of 61 gamma-ray spectrum/image sets were collected over the course of three working days (22 Compton images and 39 Pinhole/Compton images). During data collection, Compton imaging was used as the means by which to identify and prioritize hotspots. After contaminated regions were identified via Compton imaging, short-distance Pinhole spectrum/image sets were collected for additional analysis. All of the spectrum/image sets were analyzed to determine the radioisotope distribution within the GeGI field of view, as well as to provide an estimate of the activity associated with each hotspot. It was determined that the nature of residual contamination present was distributed across specific areas of elevated activity, where in some areas there was significant accumulation of contaminated material. It was also determined that no discrete sources of high-activity were present, as would be expected in the case of radioactive material product intended for sealed source manufacture. Results included the activity of residual contamination for each of the areas assessed, and an estimate of the physical area over which that contamination was distributed. It was anticipated by EPA that if decontamination were to be performed that it would involve some type of concrete scabbling or other means of physical removal of contaminated material. The GeGI data could be used to estimate the areal extent (square footage) of concrete removal that would be required for decontamination. Using the activity estimate data from the GeGI along with an estimated depth of concrete removal, planning could be performed for decontamination work (equipment and personnel), waste collection, packaging, transportation, and disposal, along with an associated cost estimate. With regard to health and safety, use of the GeGI reduced the radiation dose to the EPA R5 staff performing the assessment work. The GeGI is a non-destructive device that supports assessment of radioactively contaminated areas and sources from a distance, reducing the need for close contact to radiation, and the time necessary for personnel to operate near such hazards. Use of the GeGI in this facility assessment was our first attempt to apply this technology in what proved to be a quick and efficient decontamination assessment method. The GeGI can assess the nature and extent of residual contamination in a facility, first by quickly identifying the areas of elevated activity, followed by refined measurement and assessment of those elevated areas. The GeGI data can then be used to develop planning and a cost estimate of required decontamination and waste management activities. Since it's a non-destructive gamma identification and imaging device, it can reduce the distance of workers from radioactive sources and the dose incurred from assessment work. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Atomic-scale characterization of germanium isotopic multilayers by atom probe tomography

We report comparison of the interfacial sharpness characterization of germanium (Ge) isotopic multilayers between laser-assisted atom probe tomography (APT) and secondary ion mass spectrometry (SIMS). An alternating stack of 8-nm-thick naturally available Ge layers and 8-nm-thick isotopically enriched {sup 70}Ge layers was prepared on a Ge(100) substrate by molecular beam epitaxy. The APT mass spectra consist of clearly resolved peaks of five stable Ge isotopes ({sup 70}Ge, {sup 72}Ge, {sup 73}Ge, {sup 74}Ge, and {sup 76}Ge). The degree of intermixing at the interfaces between adjacent layers was determined by APT to be around 0.8 {+-} 0.1 nm which was much sharper than that obtained by SIMS.

36 MATERIALS SCIENCE↗

Cross sections for {sup 68}Ge production in natural- and enriched-germanium targets irradiated with protons of energy 100 MeV and background in experiments devoted to searches for the 2{beta}0{nu} decay of {sup 76}Ge

The rate of {sup 68}Ge production at sea level under the effect of the nuclear component of cosmic rays is calculated. The calculation is based on the experimental values of the cross sections for {sup 68}Ge production in natural- and enriched-germanium targets (enrichment in {sup 76}Ge) irradiated with high-energy protons. The background from the decays of {sup 68}Ge can be a serious problem in new-generation experiments devoted to searches for the 2{beta}0{nu} decay of {sup 76}Ge.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗