Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GOLD IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Tribological properties of ceramic/Ti3Al-Nb sliding couples for use as candidate seal materials to 700 deg C

Tribological properties of Ti3Al-Nb intermetallic disks sliding against alumina-boria-silicate fabric were ascertained in air at temperatures from 25 to 700 C. These materials are candidates for sliding seal applications for the National AeroSpace Plane. The tests were done using a pin on disk tribometer. Sliding was unidirectional at 0.27 m/sec under a nominal contact stress of 340 kPa. Gold sputter or ion plating deposited films were used to reduce friction and wear. Rhodium and palladium films were used beneath the gold lubricating films to prevent diffusion of the substrate into the gold at high temperature. The friction and wear of the unlubricated specimens was unacceptable. Friction coefficients were generally greater than 1.0. The ion plated gold films, when used with a rhodium diffusion barrier reduced friction by almost a factor of 2. Wear was also substantially reduced. The sputter deposited films were not adherent unless the substrate was sputter cleaned immediately prior to film deposition. Palladium did not function as a diffusion barrier.

Dellacorte, Christopher↗

Tribological properties of ceramic-(Ti3Al-Nb) sliding couples for use as candidate seal materials to 700 C

Tribological properties of Ti3Al-Nb intermetallic disks sliding against alumina-boria-silicate fabric were ascertained in air at temperatures from 25 to 700 C. These materials are candidates for sliding seal applications for the National AeroSpace Plane. The tests were done using a pin on disk tribometer. Sliding was unidirectional at 0.27 m/sec under a nominal contact stress of 340 kPa. Gold sputter or ion plating deposited films were used to reduce friction and wear. Rhodium and palladium films were used beneath the gold lubricating films to prevent diffusion of the substrate into the gold at high temperature. The friction and wear of the unlubricated specimens was unacceptable. Friction coefficients were generally greater than 1.0. The ion plated gold films, when used with a rhodium diffusion barrier reduced friction by almost a factor of 2. Wear was also substantially reduced. The sputter deposited films were not adherent unless the substrate was sputter cleaned immediately prior to film deposition. Palladium did not function as a diffusion barrier.

Dellacorte, Christhopher↗

C-O Bond Dissociation and Induced Chemical Ionization Using High Energy (CO{sub 2}){sub n}{sup +} Gas Cluster Ion Beam

A gas cluster ion beam (GCIB) source, consisting of CO{sub 2} clusters and operating with kinetic energies of up to 60 keV, has been developed for the high resolution and high sensitivity imaging of intact biomolecules. The CO{sub 2} molecule is an excellent molecule to employ in a GCIB source due to its relative stability and improved focusing capabilities, especially when compared to the conventionally employed Ar cluster source. Here we report on experiments aimed to examine the behavior of CO{sub 2} clusters as they impact a surface under a variety of conditions. Clusters of (CO{sub 2}){sub n}{sup +} (n = 2000~10,000) with varying sizes and kinetic energies were employed to interrogate both an organic and inorganic surface. The results show that C-O bond dissociation did not occur when the energy per molecule is less than 5 eV/n, but that oxygen adducts were seen in increasing intensity as the energy is above 5 eV/n, particularly, drastic enhancement up to 100 times of oxygen adducts was observed on Au surface. For Irganox 1010, an organic surface, oxygen containing adducts were observed with moderate signal enhancement. Molecular dynamics computer simulations were employed to test the hypothesis that the C-O bond is broken at high values of eV/n. These calculations show that C-O bond dissociation occurs at eV/n values less than the C-O bond energy (8.3 eV) by interaction with surface topological features. In general, the experiments suggest that the projectiles containing oxygen can enhance the ionization efficiency of surface molecules via chemically induced processes, and that CO{sub 2} can be an effective cluster ion source for SIMS experiments. .

74 ATOMIC AND MOLECULAR PHYSICS↗

Embedded Nanofibers Induced by High-Energy Ion Irradiation of Bulk GaSb

Semiconductor nanostructures have attracted widespread attention for their unique quantum-confined nanoscale properties. In particular, the luminescence properties of nanoscale semiconductors are seen as a key to the future of optoelectronic microdevice fabrication. Although numerous techniques exist for the formation and modification of nanostructures on material surfaces, fabrication of such structures embedded within the material have proved elusive. In this work, we present the formation of embedded nanofiber layers within GaSb by high energy Au+ ion irradiation, and we analyze the distinct regions of the fiber layers formed as a result. Using growth models for low energy ions, a modified growth model is presented to interpret the presence of these observed fiber regimes. Furthermore, methods for tailoring the relative sizes of the fiber layers are presented. An additional model is proposed to account for the removal of the surface layer at increasing ion fluence.

36 MATERIALS SCIENCE↗

Production and ion-ion cooling of highly charged ions in electron string ion source

The scheme of an internal injection of Au atoms into the working space of the ''Krion-2'' electron string ion source (ESIS) was applied and tested. In this scheme Au atoms are evaporated from the thin tungsten wire surface in vicinity of the source electron string. Ion beams with charge states up to Au{sup 51+} were produced. Ion-ion cooling with use of C and O coolant ions was studied. It allowed increasing of the Au{sup 51+} ion yield by a factor of 2. Ions of Kr up to charge state 28+ were also produced in the source. Electron strings were first formed with injection electron energy up to 6 keV. Methods to increase the ESIS ion output are discussed.

43 PARTICLE ACCELERATORS↗

Performance of an inverted ion source

Whereas energetic ion beams are conventionally produced by extracting ions (say, positive ions) from a plasma that is held at high (positive) potential, with ion energy determined by the potential drop through which the ions fall in the beam formation electrode system, in the device described here the plasma and its electronics are held at ground potential and the ion beam is formed and injected energetically into a space maintained at high (negative) potential. We refer to this configuration as an 'inverted ion source.' This approach allows considerable savings both technologically and economically, rendering feasible some ion beam applications, in particular small-scale ion implantation, that might otherwise not be possible for many researchers and laboratories. We have developed a device of this kind utilizing a metal vapor vacuum arc plasma source, and explored its operation and beam characteristics over a range of parameter variation. The downstream beam current has been measured as a function of extraction voltage (5-35 kV), arc current (50-230 A), metal ion species (Ti, Nb, Au), and extractor grid spacing and beamlet aperture size (3, 4, and 5 mm). The downstream ion beam current as measured by a magnetically-suppressed Faraday cup was up to as high as 600 mA, and with parametric variation quite similar to that found for the more conventional metal vapor vacuum arc ion source.

43 PARTICLE ACCELERATORS↗

Why natural monazite never becomes amorphous: Experimental evidence for alpha self-healing

Monazite, a common accessory rare-earth orthophosphate mineral in the continental crust widely used in U-Pb geochronology, holds promise for (U-Th)/He thermochronology and for the immobilization of Pu and minor actinides (MA) coming from spent nuclear fuel reprocessing. Previous results obtained on natural and plutonium-doped monazite have demonstrated the ability of this structure to maintain a crystalline state despite high radiation damage levels. However, the low critical temperature (180 °C), above which amorphization cannot be achieved in natural monazite under ion irradiation, does not explain this old and unsolved paradox: why do natural monazites, independent of their geological history, remain crystalline even when they did not experience any thermal event that could heal the defects? This is what the present study aims to address. Synthetic polycrystals of LaPO 4 -monazite were irradiated sequentially and simultaneously with α particles (He) and gold (Au) ions. Here, our results demonstrate experimentally for the first time in monazite, the existence of the defect recovery mechanism, called α-healing, acting in this structure due to electronic energy loss of α particles, which explains the absence of amorphization in natural monazite samples. This mechanism is critically important for monazite geo- and thermochronology and to design and predictively model the long-term behavior of ceramic matrices for nuclear waste conditioning.

36 MATERIALS SCIENCE↗

Laser generation of Au ions with charge states above 50+

Results of recent studies on highly charged Au ion generation, using the intense long pulses of the PALS high power iodine laser ({lambda}=1.315 {mu}m, E{sub L}=800 J/400 ps), operating under variable experimental conditions (1{omega}, 3{omega}, varying target thickness and changing focus positions), are presented. Both the ion collectors and the ion electrostatic analyzers were applied for the identification of ions in a large distance from the target. The time-of-flight collector signals were treated by a means of peak deconvolution assuming a shifted Maxwell-Boltzmann form of the constituent ion current peaks. Attention was paid to the influence of pulse precursor, which becomes evident, especially, if using thinner targets and 1{omega}. The results for 3{omega} point to the presence of several groups of ions with the highest recorded charge state Au{sup 53+}.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The potential application of ultra-nanocrystalline diamond films for heavy ion irradiation detection

The potential of utilizing the ultra-nanocrystalline (UNCD) films for detecting the Au-ion irradiation was investigated. When the fluence for Au-ion irradiation is lower than the critical value (f{sub c}= 5.0 Multiplication-Sign 10{sup 12} ions/cm{sup 2}) the turn-on field for electron field emission (EFE) process of the UNCD films decreased systematically with the increase in fluence that is correlated with the increase in sp{sup 2}-bonded phase ({pi}{sup *}-band in EELS) due to the Au-ion irradiation. The EFE properties changed irregularly, when the fluence for Au-ion irradiation exceeds this critical value. The transmission electron microscopic microstructural examinations, in conjunction with EELS spectroscopic studies, reveal that the structural change preferentially occurred in the diamond-to-Si interface for the samples experienced over critical fluence of Au-ion irradiation, viz. the crystalline SiC phase was induced in the interfacial region and the thickness of the interface decreased. These observations implied that the UNCD films could be used as irradiation detectors when the fluence for Au-ion irradiation does not exceed such a critical value.

36 MATERIALS SCIENCE↗

Dynamical Structures in Phase-Separated Films Deposited under Ion Bombardment

We report our experimental observation of ion bombardment effect on the film structures generated by co-evaporation of Au and silica. Three states are identified depending on the incident ion energy and beam current. Moderate ion bombardment creates nanoscale compositional modulations along the film growth direction. Strong ion bombardment induces disappearance of the compositional modulations. At still higher energy and flux, energetic ions sputter away all deposited atoms. The observed phenomena reflect synergistic effects of ion bombardment on the film growth in phase separated systems. Our observations suggest that ion beams can be employed to control the film structures in the deposition of phase-separated films.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Structural modifications of low-energy heavy-ion irradiated germanium

Heavy-ion irradiation of crystalline germanium (c-Ge) results in the formation of a homogeneous amorphous germanium (a-Ge) layer at the surface. This a-Ge layer undergoes structural modification such as a strong volume expansion accompanied by drastic surface blackening with further ion irradiation. In the present paper we investigate the mechanism of this ion-induced structural modification in a-Ge basically for the irradiation with I ions (3 and 9 MeV) at room and low temperature as a function of ion fluence for the ion incidence angles of {Theta}=7 deg. and {Theta}=45 deg. For comparison, Ag- and Au-ion irradiations were performed at room temperature as a function of the ion fluence. At fluences two orders of magnitude above the amorphization threshold, morphological changes were observed for all irradiation conditions used. Over a wide range of ion fluences we demonstrate that the volume expansion is caused by the formation of voids at the surface and in the depth of the projected ion range. At high ion fluences the amorphous layer transforms into a porous structure as established by cross section and plan view electron microscopy investigations. However, the formation depth of the surface and buried voids as well as the shape and the dimension of the final porous structure depend on the ion fluence, ion species, and irradiation temperature and will be discussed in detail. The rate of the volume expansion (i.e., porous layer formation) depends linearly on the value of {epsilon}{sub n}. This clearly demonstrates that the structural changes are determined solely by the nuclear energy deposited within the amorphous phase. In addition, at high ion fluences all perpendicular ion irradiations lead to a formation of a microstructure at the surface, whereas for nonperpendicular ion irradiations a nonsaturating irreversible plastic deformation (ion hammering) without a microstructure formation is observed. For the irradiation with ion energies of several MeV, the effect of plastic deformation shows a linear dependence on the ion fluence. Based on these results, we provide an explanation for the differences in surface morphology observed for different angles of incidence of the ion beam will be discussed in detail.

36 MATERIALS SCIENCE↗

Response of Nanocrystalline 3C Silicon Carbide to Heavy-Ion Irradiation

Nanostructured materials are generally believed to be more radiation resistant. This study reports on Au ion induced amorphization in nanocrystalline 3C-SiC, characterized using x-ray diffraction, transmission electron microscopy and Raman spectroscopy. Full amorphization at room temperature occurs at a comparable dose to that for bulk SiC single crystals. The behavior is attributed to a high ion flux and sluggish migration of point defects produced during irradiation. The results may have a significant implication of using nanophased SiC in extremely high radiation environments.

36 MATERIALS SCIENCE↗

Shot-to-shot reproducibility in the emission of fast highly charged metal ions from a laser ion source

The generation of fast highly charged metal ions with the use of the sub-nanosecond Prague Asterix Laser System, operated at a fundamental wavelength of 1315 nm, is reported. Particular attention is paid to shot-to-shot reproducibility in the ion emission. Au and Pd targets were exposed to intensities up to 5 x 10{sup 16} W/cm{sup 2}. Above the laser intensity threshold of {approx}3 x 10{sup 14} W/cm{sup 2} the plasma is generated in a form of irregular bursts. The maximum energy of protons constituting the leading edge of the fastest burst reaches a value up to 1 MeV. The fast ions in the following bursts have energy gradually decreasing with the increasing burst number, namely, from a value of about 0.5 MeV/charge regardless of the atomic number and mass of the ionized species.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Shape transformation of Sn nanocrystals induced by swift heavy-ion irradiation and the necessity of a molten ion track

We report on the spherical to rodlike shape transformation of Sn nanocrystals (NCs) embedded in amorphous SiO{sub 2} following irradiation with 185 MeV Au ions. Consistent with previous reports for other metals, transmission electron microscopy demonstrates that under irradiation, Sn NCs larger than a critical size (11 nm) elongate parallel to the incident ion direction, while smaller particles remain spherical. Irradiation-induced NC dissolution is significant, as evident from the formation of smaller NCs in place of their original larger counterparts. Using formation conditions that yield Sn NCs at the amorphous-SiO{sub 2}/crystalline-Si interface, we show that the irradiation-induced shape change occurs only within the SiO{sub 2} layer, in the direction opposite to that of the incident ions. We suggest this demonstrates the necessity of a molten ion track and provides further evidence for an elongation process involving NC melting and flow.

36 MATERIALS SCIENCE↗

Evolution of Crystallinity and Texturing on 120 MeV Au Ion Irradiation on NiO Thin Films

NiO thin films grown on Si(100) substrate by electron beam evaporation and sintered at 500 deg. C and 700 deg. C were irradiated with 120 MeV {sup 197}Au{sup 9+} ions. The FCC structure of the sintered films was retained up to the highest fluence (3 x l0{sup 13} ions.cm{sup -2}) of irradiation. As against the expected amorphization due to ion irradiation when electronic energy loss exceeds certain threshold value, we observe an improvement of crystallinity and grain orientation at certain fluences of irradiation.

36 MATERIALS SCIENCE↗

SU-E-T-460: Impact of the LINAC Repetition Rate On a High-Resolution Liquid Ionization Chamber Array for Patient-Specific QA

Purpose: The purpose of this study is to investigate the LINAC repetition-rate (dose-rate) dependence of OCTAVIUS 1000SRS liquid ionization chamber (LIC) array for patient specific QA of SRT plans delivered with flattening-filter-free (FFF) beams. Methods: 1) The repetition-rate dependence of 1000SRS was measured in a phantom constructed with 5-cm solid water above and below the array for build-up and backscatter. A 0.3cc calibrated ion chamber was also placed along the central axis 2.3cm below the center chamber of the array for normalizing LINAC output fluctuation. The signals from the center chamber of the array under different repetition rates in the range of 400–2400 MU/min for 6xFFF and 10xFFF beams on a Varian TrueBeamSTx LINAC, normalized by the independent chamber readings, were analyzed for the array response dependence on repetition rates. 2) Twelve Step-and-shoot IMRS QA plans (6xFFF and 10xFFF) were delivered to the array under different repetition rates for analysis and comparison. 3) The absolute doses measured by the center chamber were compared to measurements using an independent ionization chamber with the identical setup, taken as the gold standard. 4) The correction factors based on the actual delivery repetition rate were applied to the measurements, and the results were compared again to the gold standard. Results: 1) The 1000SRS array exhibited repetition-rate dependence for FFF beams, up to 5% for 6xFFF and 10% for 10xFFF; 2) The array showed clinically-acceptable repetition-rate dependence for regular flattened beams; 3) This repetition-rate dependence significantly affected the measurement accuracy, thereby affecting IMRS QA results; 4) By applying an empirical repetition-rate correction, the corrected measurements agreed better with the gold standard ion chamber measurements. Conclusion: OCTAVIUS 1000SRS LIC array exhibited considerable repetition-rate dependence for FFF beams, which will affect the accuracy of the absolute QA measurements, especially for IMRS plans with the step-and-shoot technique.

60 APPLIED LIFE SCIENCES↗

Spontaneous formation of superconducting NiBi{sub 3} phase in Ni-Bi bilayer films

We report the spontaneous formation of superconducting NiBi{sub 3} phase in thermally evaporated Ni-Bi bilayer films. High reaction-diffusion coefficient of Bi is believed to drive the formation of NiBi{sub 3} during the deposition of Bi on the Ni film. Cross sectional transmission electron microscopy and glancing incidence X-ray depth profiling confirmed the presence of NiBi{sub 3} throughout the top Bi layer. Superconducting transition at ∼3.9 K, close to the bulk value, was confirmed by transport and magnetization measurements. The bilayers were irradiated with varying fluence of 100 MeV Au ions to study the robustness of superconducting order in presence of large concentration of defects. Superconducting parameters of NiBi{sub 3}, such as transition temperature and upper critical field, remained unchanged upto an ion dose of 1 × 10{sup 14} ions/cm{sup 2}. The diffusive formation of NiBi{sub 3} in Ni opens the possibility of studying superconducting proximity effect at a truly clean superconductor-ferromagnet interface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Radiation stability of graphene under extreme conditions

In this letter, we report radiation stability of graphene under extreme condition of high energy density generated by 150 MeV Au ion irradiation. The experiment reveals that graphene is radiation resistant for irradiation at 10{sup 14 }ions/cm{sup 2} of 150 MeV Au ions. It is significant to note that annealing effects are observed at lower fluences whereas defect production occurs at higher fluences but significant crystallinity is retained. Our results demonstrate applicability of graphene based devices in radiation environment and space applications.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗