Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flight Control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Role of Ce 4 + in the scintillation mechanism of codoped Gd 3 Ga 3 Al 2 O 12 : Ce

To control the time-response performance of widely used cerium-activated scintillators in cutting-edge medical-imaging devices, such as time-of-flight positron-emission tomography, a comprehensive understanding of the role of Ce valence states, especially stable Ce 4+ , in the scintillation mechanism is essential. However, despite some progress made recently, an understanding of the physical processes involving Ce 4+ is still lacking. The aim of this work is to clarify the role of Ce 4+ in scintillators by studying Ca 2+ codoped Gd 3 Ga 3 Al 2 O1 2 ∶Ce (GGAG∶Ce). By using a combination of optical absorption spectra and x-ray absorption near-edge spectroscopies, the correlation between Ca 2+ codoping content and the Ce 4+ fraction is seen. The energy-level diagrams of Ce 3+ and Ce 4+ in the Gd 3 Ga 3 Al 2 O 12 host are established by using theoretical and experimental methods, which indicate a higher position of the 5d 1 state of Ce 4+ in the forbidden gap in comparison to that of Ce 3+ . Underlying reasons for the decay-time acceleration resulting from Ca 2+ codoping are revealed, and the physical processes of the Ce 4+ -emission model are proposed and further demonstrated by temperature-dependent radioluminescence spectra under x-ray excitation.

Wu, Yuntao↗

Measurement of Beam Energy in the Fermilab's Linac taken at the Transfer Line

Linac is the first machine in the accelerator chain at Fermilab where H$^{-}$ ions are accelerated from 35 keV to 401.5\,MeV and then injected into a synchronton known as Booster where they are stripped of their electrons to become protons. One of the tools used during tuning of the Linac extraction energy is two beam pickups known as Griffin Detectors. Our goal is to control the output energy using machine learning techniques to increase the reliability and quality of the beam delivered from Linac. The first step is to understand the data from the diagnostics to develop reliable and accurate energy measurement, and control methods before implementing machine learning techniques. Two methods of energy measurement were studied, and their results are compared. The first method was the time of flight measurement using Beam Position Monitors that provide beam phase measurement. The second method used the relation between beam transverse positions and dispersion values to calculate momentum variation. The results of these two measurement methods are found to be consistent.

43 PARTICLE ACCELERATORS↗

Measurement of Beam Energy in the Fermilab's Linac taken at the transfer Line

Linac is the first machine in the Accelerator chain at Fermilab where 𝐻− particles are accelerated from 35 keV to 400 MeV and travel to the Booster where they are stripped. of the extra electrons to become protons. The Booster requires stable beam energy at injection. The Linac extraction energy tuning has been performed using two Beam Velocity Monitors (a.k.a Griffin detectors) to maintain stable relative energy between the Booster and the Linac. Our goal is to control the Linac energy parameters using Machine Learning techniques to increase reliability and quality of beam delivered from Linac. The first step is to understand the data from the Linac extraction diagnostics; and develop reliable, accurate methods for energy measurement and control before implementing machine learning. There were two methods of energy measurement implemented, and the results of these are compared. The first method was time of flight measurements using the Phase probes inside B eam Position Monitors (BPM) that provide the beam’s phase of arrival data. The second method used the relation between beam position data from the BPMs and dispersion values from the 400MeV MAD-X model to calculate momentum variation. The results of these two energy measurement methods compare well as the Linac energy is varied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of autonomous magnetometer rotorcraft for wide area assessment

Large areas across the United States are potentially contaminated with UXO, with some ranges encompassing tens to hundreds of thousands of acres. Technologies are needed which will allow for cost effective wide area scanning with 1) near 100 % coverage and 2) near 100 % detection of subsurface ordnance or features indicative of subsurface ordnance. The current approach to wide area assessment is a multi-level one, in which medium - altitude fixed wing optical imaging is used for an initial site assessment. This assessment is followed with low altitude manned helicopter based magnetometry. Subsequent to this wide area assessment targeted surface investigations are performed using either towed geophysical sensor arrays or man portable sensors. In order to be an effective tool for small UXO detection, the sensing altitude for magnetic site investigations needs to be on the order of 1 – 3 meters. These altitude requirements mean that manned helicopter surveys will generally only be feasible in large, open and relatively flat terrains. While such surveys are effective in mapping large areas relatively fast there are substantial mobilization/demobilization, staffing and equipment costs associated with these surveys (resulting in costs of approximately $100-$150/acre). In addition, due to the low altitude there are substantial risks to pilots and equipment. Surface towed arrays provide high resolution maps but have other limitations, e.g. in their ability to navigate rough terrain effectively. There is thus a need for other systems which can be used for effective data collection. An UAV (Unmanned Aerial Vehicle) magnetometer platform is an obvious alternative. The motivation behind such a system is that it reduces risk to operators, is lower in initial and Operational and Maintenance (O&M) costs (and can thus potentially be applied to smaller sites) and has the potential of being more effective in terms of detection and possibly characterization (through the use of dynamic acquisition, i.e. survey mission inflight reprioritization). We describe and report on a one year effort with as primary goal to provide a recommendation to SERDP for a path forward in the implementation of one or more autonomous unmanned magnetometer rotorcraft platforms. This recommendation (which is provided in chapter 6) is based on the following three elements a) An assessment on the applicability of autonomous rotorcraft magnetometer systems to the current DoD site inventory, and an initial assessment of which type(s) of autonomous unmanned magnetometer rotorcraft platforms (in terms of performance characteristics such as payload, altitude, obstacle avoidance, production rate and flight time) would be most relevant to this inventory (chapter 3); b) An evaluation of the feasibility of assembling such platforms from commercial components (unmanned rotorcraft, control systems and sensors – both magnetometer sensors and supporting sensors). This evaluation included several highly successful field tests (chapter 4 and 5); c) A recommendation of the path forward, which includes a detailed outline of the efforts required in the design, assembly and testing of different modular platforms (chapter 6)

58 GEOSCIENCES↗

High-resolution time-of-flight mass spectrometry fingerprinting of metabolites from cecum and distal colon contents of rats fed resistant starch

Time-of-flight mass spectrometry along with statistical analysis was utilized to study metabolic profiles among rats fed resistant starch (RS) diets. Fischer 344 rats were fed four starch diets consisting of 55 % (w/w, dbs) starch. A control starch diet consisting of corn starch was compared against three RS diets. The RS diets were high-amylose corn starch (HA7), HA7 chemically modified with octenyl succinic anhydride, and stearic-acid-complexed HA7 starch. A subgroup received antibiotic treatment to determine if perturbations in the gut microbiome were long lasting. A second subgroup was treated with azoxymethane (AOM), a carcinogen. At the end of the 8-week study, cecal and distal colon content samples were collected from the sacrificed rats. Metabolites were extracted from cecal and distal colon samples into acetonitrile. The extracts were then analyzed on an accurate-mass time-of-flight mass spectrometer to obtain their metabolic profile. The data were analyzed using partial least-squares discriminant analysis (PLS-DA). The PLS-DA analysis utilized a training set and verification set to classify samples within diet and treatment groups. PLS-DA could reliably differentiate the diet treatments for both cecal and distal colon samples. The PLS-DA analyses of the antibiotic and no antibiotic-treated subgroups were well classified for cecal samples and modestly separated for distal colon samples. PLS-DA analysis had limited success separating distal colon samples for rats given AOM from those not treated; the cecal samples from AOM had very poor classification. Mass spectrometry profiling coupled with PLS-DA can readily classify metabolite differences among rats given RS diets.

36 MATERIALS SCIENCE↗

Mass Spectrometry and Fourier Transform Infrared Spectroscopy for Analysis of Biological Materials

Time-of-flight mass spectrometry along with statistical analysis was utilized to study metabolic profiles among rats fed resistant starch (RS) diets. Fischer 344 rats were fed four starch diets consisting of 55% (w/w, dbs) starch. A control starch diet consisting of corn starch was compared against three RS diets. The RS diets were high-amylose corn starch (HA7), HA7 chemically modified with octenyl succinic anhydride, and stearic-acid-complexed HA7 starch. A subgroup received antibiotic treatment to determine if perturbations in the gut microbiome were long lasting. A second subgroup was treated with azoxymethane (AOM), a carcinogen. At the end of the eight week study, cecal and distal-colon contents samples were collected from the sacrificed rats. Metabolites were extracted from cecal and distal colon samples into acetonitrile. The extracts were then analyzed on an accurate-mass time-of-flight mass spectrometer to obtain their metabolic profile. The data were analyzed using partial least-squares discriminant analysis (PLS-DA). The PLS-DA analysis utilized a training set and verification set to classify samples within diet and treatment groups. PLS-DA could reliably differentiate the diet treatments for both cecal and distal colon samples. The PLS-DA analyses of the antibiotic and no antibiotic treated subgroups were well classified for cecal samples and modestly separated for distal-colon samples. PLS-DA analysis had limited success separating distal colon samples for rats given AOM from those not treated; the cecal samples from AOM had very poor classification. Mass spectrometry profiling coupled with PLS-DA can readily classify metabolite differences among rats given RS diets.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sensing and Sampling of Trace Contaminations by a Dexterous Hexrotor UAV at Nuclear Facilities - 18600

Safe and efficient cleanups are a priority for decontamination and decommissioning of nuclear facilities. The contaminations of byproducts and wastes in such nuclear facilities pose a serious problems while decommissioning, to both the operators and public. Sensing these contaminations and cleaning them is an essential part of the safety procedures. The contaminations might range from low-energy to high-energy byproducts. Sensing these byproducts would require contact based or non-contact based sensing, based on its energy levels. Byproducts such as americium, are low-energy which makes it difficult to sense and sample without contact. Therefore, the workers need to physically swab the surfaces to collect the samples of these contaminations. These tasks pose a great danger for the safety of the human workers which includes the risk to reach greater heights, exposure to the radiation and sampling the entire building. A robotic solution is much more desirable in these cases, where the worker can safely handle the contaminations from a safe area. Use of robotic technologies inside these hazardous environments ensures the safety and enhances the performance. The more suitable robotic solution for reaching great heights and covering large areas of nuclear facilities, are aerial vehicles. Multi-rotor unmanned aerial vehicle (UAV) are chosen for their ability to hover at a position and also fly around in confined spaces. Quadrotors are a common choice of multi-rotor UAVs both research and industry because of its ease to fly and commercial availability. For the applications during the cleanups we need the UAV to not only hover and fly in confined spaces, but also interact with the physical world. Despite of quadrotor's advantages, they are not a best suit as they can't interact with the physical world. The tasks involving physical interactions would require the UAV to apply arbitrary forces and torques in all six degrees of freedom (DOF). As quadrotors are under-actuated and non-holonomic in motion, they cannot exert all the required forces. At Collaborative Robotics Lab, Purdue University, we developed a novel multi-rotor UAV solution, Dexterous Hexrotor, which can exert arbitrary forces and torques in all six DOF, independently and instantaneously. This enables the UAV platform to quickly respond to the external disturbances and precisely hold its position during the mission. The Dexterous Hexrotor serves as a robotic tool for the workers to perform sensing and sampling during the cleanups. Workers can operate Dexterous Hexrotor manually and/or semi-autonomously with human intervention. Manual control requires the worker to fly the Dexterous Hexrotor using a remote control. So the workers should possess knowledge on flying the UAV and to perform physical interaction. A semiautonomous Dexterous Hexrotor requires human input to some extent and requires very less knowledge of flying. The autonomy is designed to operate in flight mode and sampling mode. In flight mode, Dexterous Hexrotor takes off from a 'safe' area, reaches the desired altitude, and fly autonomously towards a sampling point. This sampling point is the target position specified on the 2D reference map. This mode also includes navigation towards the sampling point, avoiding the obstacles in the constrained environment. After reaching a stopping point, Dexterous Hexrotor waits for the human input for a target location to swab and collect samples. The Dexterous Hexrotor is now in sampling mode and waits for the human input. The human operator selects the swabbing location through the live streaming video from onboard camera. Through visual servoing, aided by the map, the UAV will move closer towards the target position. It then transitions to the impact control scheme to perform physical interaction with the wall and collects samples. Once the sample is collected, it autonomously returns back to the takeoff position in 'safe' area for the analysis by mass spectrometry. In this paper, we majorly focus on the physical interaction strategy and the required components which enables the autonomy. Decommissioning of nuclear facilities requires decontamination inside the entire buildings. Decontamination of nuclear facilities involves sensing and sampling the huge buildings, long shafts, etc. Sampling the entire facility is not possible due to the limitation in Dexterous Hexrotor's flight time. But this can be achieved by using a swarm of Dexterous Hexrotors to cover larger areas. The onboard robotic arm can be designed based on the applications such as cleaning, applying sealants, etc. The modularity of the design allows us to switch components as per the requirements of the task. These kind of robotic solutions functioning as tools for the workers, aims to make the work environment safer and playful. (authors)

42 ENGINEERING↗

Autonomous aerial flight path inspection using advanced manufacturing techniques

Robotic systems have shown capabilities to perform inspection tasks in dangerous and difficult-to-access environments, such as those found in different components of power plants. However, most of the current robotic inspection technology is designed for specific components. Aerial robots, commonly termed as Drones, have raised an option to inspect a wider range of structural components. Nevertheless, current aerial inspecting technology still relies on a human pilot with limited line of sight, field of view and a reduced perception as the drone flies away, which prevents performing close-quarter inspection in intricate, structurally complex and GPS-denied environments. This work introduces offline inspection path generation methods based on robotics-integrated to manufacturing techniques. One method uses computer-aided manufacturing (CAM) techniques and the other an additive manufacturing (AM) approach to generate the flight path. That is to say, the drone would fly along the path described by a 3D (Three Dimensional) printer’s extruder or a CNC (Computer Numerical Control) machining tool, enabling to fly very close the structure even in physical structures with a complex geometry. Once the trajectories are generated, they are introduced for its validation in the Gazebo robotics simulator. Simulation results demonstrate the proper performance of the method and confirm that this approach can be used for close inspection of structural components.

42 ENGINEERING↗

Subtractive fabrication of ferroelectric thin films with precisely controlled thickness

The ability to control thin-film growth has led to advances in our understanding of fundamental physics as well as to the emergence of novel technologies. However, common thin-film growth techniques introduce a number of limitations related to the concentration of defects on film interfaces and surfaces that limit the scope of systems that can be produced and studied experimentally. Here, we developed an ion-beam based subtractive fabrication process that enables creation and modification of thin films with pre-defined thicknesses. To accomplish this we transformed a multimodal imaging platform that combines time-of-flight secondary ion mass spectrometry with atomic force microscopy to a unique fabrication tool that allows for precise sputtering of the nanometer-thin layers of material. To demonstrate fabrication of thin-films with in situ feedback and control on film thickness and functionality we systematically studied thickness dependence of ferroelectric switching of lead-zirconate-titanate, within a single epitaxial film. Lastly, our results demonstrate that through a subtractive film fabrication process we can control the piezoelectric response as a function of film thickness as well as improve on the overall piezoelectric response versus an untreated film.

36 MATERIALS SCIENCE↗

Analytical and experimental studies of leak location and environment characterization for the international space station

The International Space Station program is developing a robotically-operated leak locator tool to be used externally. The tool would consist of a Residual Gas Analyzer for partial pressure measurements and a full range pressure gauge for total pressure measurements. The primary application is to demonstrate the ability to detect NH{sub 3} coolant leaks in the ISS thermal control system. An analytical model of leak plume physics is presented that can account for effusive flow as well as plumes produced by sonic orifices and thruster operations. This model is used along with knowledge of typical RGA and full range gauge performance to analyze the expected instrument sensitivity to ISS leaks of various sizes and relative locations (“directionality”). The paper also presents experimental results of leak simulation testing in a large thermal vacuum chamber at NASA Goddard Space Flight Center. This test characterized instrument sensitivity as a function of leak rates ranging from 1 lb{sub m/}/yr. to about 1 lb{sub m}/day. This data may represent the first measurements collected by an RGA or ion gauge system monitoring off-axis point sources as a function of location and orientation. Test results are compared to the analytical model and used to propose strategies for on-orbit leak location and environment characterization using the proposed instrument while taking into account local ISS conditions and the effects of ram/wake flows and structural shadowing within low Earth orbit.

42 ENGINEERING↗

Optical Control of Reactions between Water and Laser-Cooled Be + Ions

In this work, we investigate reactions between laser-cooled Be + ions and room-temperature water molecules using an integrated ion trap and high-resolution time-of-flight mass spectrometer. This system allows simultaneous measurement of individual reaction rates that are resolved by reaction product. The rate coefficient of the Be + ( 2 S 1/2 ) + H 2 O → BeOH + + H reaction is measured for the first time and is found to be approximately two times smaller than predicted by an ion–dipole capture model. Zero-point-corrected quasi-classical trajectory calculations on a highly accurate potential energy surface for the ground electronic state reveal that the reaction is capture-dominated, but a submerged barrier in the product channel lowers the reactivity. Furthermore, laser excitation of the ions from the 2 S 1/2 ground state to the 2 P 3/2 state opens new reaction channels, and we report the rate and branching ratio of the Be + ( 2 P 3/2 ) + H 2 O → BeOH + + H and H 2 O + + Be reactions. Lastly, the excited-state reactions are nonadiabatic in nature.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Visualization of Solid-State Synthesis for Chalcogenide Na Superionic Conductors by in-situ Neutron Diffraction

Chalcogenide superionic sodium (Na) conductors are great potential as solid electrolytes (SEs) in all-solid-state Na batteries with advantages of high energy density and safety, and cost effectiveness. For solid Na-ion conductors, their crystal structures and ionically conductive properties are strongly influenced by the synthetic approaches and processing parameters. Thus, understanding the synthesis process is essential to control the structures and phases and thereby yields to Na-ion conductors with desirable properties. Thanks to the high-flux and deep-penetrating time-of-flight neutron diffraction (ND), we employed in situ experiments to track real-time structural changes of two chalcogenide SEs (Na 3 SbS 4 and Na 3 SbS 3.5 Se 0.5 ) during the solid-state synthesis. For these two conductors, the ND results reveal a fast one-step reaction for the synthesis and the molten process when heating up, and the recrystallization as well as the cubic-to-tetragonal phase transition up on cooling. Moreover, Se-doping is found to influence the reaction temperatures, lattice parameter and structure stability based on neutron experimental observations and theoretical simulation. This work presents a detailed structural study using in situ neutron diffraction technology for the solid synthesis process of chalcogenide Na-ion conductors, beneficial for the design and synthesis of new solid-state conductors.

25 ENERGY STORAGE↗

NPFTURBULENCE: Fast Response Temperature by Airborne Measurements

The original data were collected during the field campaign of the “Turbulent layers promoting New Particle Formation” experiment (NPFTURBULENCE; https://www.arm.gov/research/campaigns/aaf2024npfturbulence; https://www.arm.gov/publications/programdocs/doe-sc-arm-25-004.pdf ) over the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) Atmospheric Observatory (https://www.arm.gov/capabilities/observatories/sgp ) in north-central Oklahoma. The ARM Aerial Facility ArcticShark uncrewed aerial system (UAS, https://www.arm.gov/capabilities/observatories/aaf/uas) was based at Blackwell–Tonkawa Municipal Airport (IATA: BWL, ICAO: KBKN, FAA LID: BKN, 36.74475° N, 97.34918° W, 313.9 m MSL), for the field campaign from May 5 through May 29, 2024. The ArcticShark UAS performed 11 flights, including 10 research flights over the Central Facility of the ARM SGP to measure atmospheric state, turbulence, surface IR temperature and imagery, aerosol number concentration and size distribution. The current dataset presents fast response temperature in the atmospheric boundary layer and lower free troposphere measured on the airborne platform throughout the field campaign. The primary instruments used to create the current dataset were the fine wire thermocouple probe, Pitot-static system (part of the UAS control), and infrared gas analyzer sensor for H2O and CO2 (LI-840A). All parameters used in the temperature calculations (static and dynamic pressure, absolute humidity in form of dew point temperature) were included in the data set. For user convenience, one additional parameter was also included: the type of flight flag (level, up, down, turn, and combination of thereof).

Air temperature↗

Laser produced streams of Ge ions accelerated and optimized in the electric fields for implantation into SiO{sub 2} substrates

Ge crystals were prepared by means of laser-induced ion implantation technique. A Nd:YAG pulsed laser (repetition rate: 10 Hz; pulse duration: 3.5 ns; pulse energy: {approx}0.5 J) was used both as an ion source and to carry out the ablation processes. The optimization of the laser-generated ion beam parameters in a broad energy and current density range has been obtained controlling the electrostatic field parameters. Numerical simulations of the focusing system, performed adopting an OPERA 3D code, and an investigation of the ion characteristics, using the ion time-of-flight method, have allowed to optimize the preparation parameters. The structural properties of the samples were investigated by means of x-ray photoelectron, micro-Raman spectroscopies, and scanning electron microscopy techniques. Experimental results show that, by appropriately varying the ion implantation parameters and by a post-preparation annealing treatment, it is possible to achieve the development of a micrometer-sized crystalline Ge phase and/or an amorphous one.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Predictive guidance flight

The various technologies presented herein relate to utilizing predictive guidance during one or more phases of a trajectory flown by an interceptor during interception with a target. The trajectory of the interceptor comprises an initial phase, a predictive phase, and a final phase. The initial phase includes the launching of the interceptor and can be unguided. The predictive phase directs the interceptor towards the target, wherein the predictive phase utilizes predictive guidance to control the trajectory of the interceptor based upon a predicted location of the target relative to the current locations of the target and the interceptor. During the predictive phase, a motor(s) can be cycled on and off, causing a period(s) where the interceptor is being propelled by the ignited motor, and a period(s) where the interceptor is propelled by its own momentum after cessation of power from the motor, e.g., unpowered flight.

Spooner, Jeffrey T.↗

Unimolecular dissociation dynamics of electronically excited HCO(Ã 2 A"): rotational control of nonadiabatic decay

The photoinduced unimolecular decay of the electronically excited HCO(Ã 2 A") is investigated in a combined experimental–theoretical study. The molecule is excited to the (1, n 2 , 0) combination bands, which decay via Renner–Teller coupling to the ground electronic state. The rovibrational state distribution of the CO fragment was measured via the high-n Rydberg H-atom time-of-flight method and calculated using a wave packet method on an accurate set of potential energy surfaces. It is shown that the non-adiabatic decay rate is strongly modulated by the HCO rotational angular momentum, which leaves unique signatures in the product state distribution. Finally, the experimentally observed bimodal rotational distribution of the dominant CO(v = 0) fragment is likely due to decay of different vibronic states populated by the excitation and modulated by the excited state lifetime, which is in turn controlled by the parent rotational quantum number.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Coverage Dependent Charge Reduction of Cationic Gold Clusters on Surfaces Prepared Using Soft Landing of Mass-selected Ions

The ionic charge state of monodisperse cationic gold clusters on surfaces may be controlled by selecting the coverage of mass-selected ions soft landed onto a substrate. Polydisperse diphosphine-capped gold clusters were synthesized in solution by reduction of chloro(triphenylphosphine)gold(I) with borane tert-butylamine in the presence of 1,3-bis(diphenylphosphino)propane. The polydisperse gold clusters were introduced into the gas phase by electrospray ionization and mass selection was employed to select a multiply charged cationic cluster species (Au11L53+, m/z = 1409, L = 1,3-bis(diphenylphosphino)propane) which was delivered to the surfaces of four different self-assembled monolayers on gold (SAMs) at coverages of 1011 and 1012 clusters/mm2. Employing the spatial profiling capabilities of in-situ time-of-flight secondary ion mass spectrometry (TOF-SIMS) it is shown that, in addition to the chemical functionality of the monolayer (as demonstrated previously: ACS Nano, 2012, 6, 573) the coverage of cationic gold clusters on the surface may be used to control the distribution of ionic charge states of the soft-landed multiply charged clusters. In the case of a 1H,1H,2H,2H-perfluorodecanethiol SAM (FSAM) almost complete retention of charge by the deposited Au11L53+ clusters was observed at a lower coverage of 1011 clusters/mm2. In contrast, at a higher coverage of 1012 clusters/mm2, pronounced reduction of charge to Au11L52+ and Au11L5+ was observed on the FSAM. When soft landed onto 16- and 11-mercaptohexadecanoic acid surfaces on gold (16,11-COOH-SAMs), the mass-selected Au11L53+ clusters exhibited partial reduction of charge to Au11L52+ at lower coverage and additional reduction of charge to both Au11L52+ and Au11L5+ at higher coverage. The reduction of charge was found to be more pronounced on the surface of the shorter (thinner) C11 than the longer (thicker) C16-COOH-SAM. On the surface of the 1-dodecanethiol (HSAM) monolayer, the most abundant charge state was found to be Au11L52+ at lower coverage and Au11L5+ at higher coverage, respectively. A coverage-dependent electron tunneling mechanism is proposed to account for the observed reduction of charge of mass-selected multiply charged gold clusters soft landed on SAMs. The results demonstrate that one of the critical parameters that influence the chemical and physical properties of supported metal clusters, ionic charge state, may be controlled by selecting the coverage of charged species soft landed onto surfaces.

charge reductionkk↗

Progress in the Measurement of Prompt Neutron Output in Neutron-Induced Fission of 239 Pu: The Chi-Nu Project

Knowledge of the prompt neutron output from neutron-induced fission of 239 Pu is essential to nuclear defense and energy applications. Because the experimental data base is inadequate to constrain models of the spectrum of neutrons from fission, we have embarked on a multi-year program of new measurements of the prompt fission neutron spectrum as a function of the energy of the incident neutron that induces the fission. This is a joint LANL-LLNL project with participation by four university groups in advanced detector development. In the past year much progress has been achieved. The building housing the experiment has been completed and the flight paths including one for this experiment are now constructed. A parallel-plate avalanche counter (PPAC) containing 235 U is installed and working in the beam line. Neutron detectors for both low (<1 MeV) and high (> 0.5 MeV) neutrons have been assembled. The data acquisition system based on waveform digitizers has undergone extensive development and now can handle 10 PPAC channels and 10 neutron detectors simultaneously. In addition, a detector test station centered on a 252 Cf spontaneous fission chamber has been commissioned so that we can characterize our neutron detectors in a well understood experimental environment. Analysis of experiments at this facility has helped us understand the performance of several types of neutron detectors. In addition, the analysis work uncovered that the “standard” 252 Cf fission neutron spectrum in MCNPX disagrees significantly from that presently accepted by the international standards community. One year ago we submitted a report (LA-UR-11-05576) on the accuracies that could be reached under certain assumptions. Several sources of possible systematic uncertainties were identified, and procedures to control these uncertainties were suggested. This report is included as an appendix to this report. One element missing from these estimates was the contribution of backgrounds. It could not be quantified because, at that time, the building and flight path for the experiments had not been constructed. We now have made some measurements of the background and can now add this component to the accuracy projections. This report summarizes the progress in the past year. It also discusses measurements reported in the literature and some factors that should be considered when using these data to optimize parameters in nuclear model codes used in constructing evaluated nuclear data bases.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗