Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Fire Detection Organizing Questions

Verified models of fire precursor transport in low and partial gravity: a. Development of models for large-scale transport in reduced gravity. b. Validated CFD simulations of transport of fire precursors. c. Evaluation of the effect of scale on transport and reduced gravity fires. Advanced fire detection system for gaseous and particulate pre-fire and fire signaturesa: a. Quantification of pre-fire pyrolysis products in microgravity. b. Suite of gas and particulate sensors. c. Reduced gravity evaluation of candidate detector technologies. d. Reduced gravity verification of advanced fire detection system. e. Validated database of fire and pre-fire signatures in low and partial gravity.

Source record↗

Fireworthiness of transport aircraft interior systems

The fire worthiness of air transport interiors was evaluated. The effect of interior systems on the survival of passengers and crew in an uncontrolled transport aircraft fire is addressed. Modification of aircraft interior subsystem components which provide improvements in aircraft fire safety are examined. Three specific subsystem components, interior panels, seats and windows, offer the most immediate and highest payoff by modifying interior materials of existing aircrafts. It is shown that the new materials modifications reduce the fire hazards because of significant reduction in their characteristic flame spread, heat release, and smoke and toxic gas emissions.

Parker, J. A.↗

Analysis of Fire Calls to an Industrial Complex Over a 12-year Period

This paper gives an analysis of fire calls from over a decade of operations at a process facility. These data include valid alarms, unwanted or false alarms, ambulance calls, and hazardous material cleanup calls. Of special interest are false alarms, which are not only a nuisance to facility productivity but are detrimental to public and facility safety. Of the fire calls listed here, over half were from false alarms. The results given are compared to National Fire Protection Association data. The data presented can serve as exemplar data for future facilities and can be compared to other operating facilities’ experiences.

99 GENERAL AND MISCELLANEOUS↗

Edge Diffusion Flame Propagation and Stabilization Studied

In most practical combustion systems or fires, fuel and air are initially unmixed, thus forming diffusion flames. As a result of flame-surface interactions, the diffusion flame often forms an edge, which may attach to burner walls, spread over condensed fuel surfaces, jump to another location through the fuel-air mixture formed, or extinguish by destabilization (blowoff). Flame holding in combustors is necessary to achieve design performance and safe operation of the system. Fires aboard spacecraft behave differently from those on Earth because of the absence of buoyancy in microgravity. This ongoing in-house flame-stability research at the NASA Glenn Research Center is important in spacecraft fire safety and Earth-bound combustion systems.

Takahashi, Fumiaki↗

Spacecraft Fire Suppression: Testing and Evaluation

The objective of this project is the testing and evaluation of the effectiveness of a variety of fire suppressants and fire-response techniques that will be used in the next generation of spacecraft (Crew Exploration Vehicle, CEV) and planetary habitats. From the many lessons learned in the last 40 years of space travel, there is common agreement in the spacecraft fire safety community that a new fire suppression system will be needed for the various types of fire threats anticipated in new space vehicles and habitats. To date, there is no single fire extinguishing system that can address all possible fire situations in a spacecraft in an effective, reliable, clean, and safe way. The testing conducted under this investigation will not only validate the various numerical models that are currently being developed, but it will provide new design standards on fire suppression that can then be applied to the next generation of spacecraft extinguishment systems. The test program will provide validation of scaling methods by conducting small, medium, and large scale fires. A variety of suppression methods will be tested, such as water mist, carbon dioxide, and nitrogen with single and multiple injection points and direct or distributed agent deployment. These injection methods cover the current ISS fire suppression method of a portable hand-held fire extinguisher spraying through a port in a rack and also next generation spacecraft units that may have a multi-point suppression delivery system built into the design. Consideration will be given to the need of a crew to clean-up the agent and recharge the extinguishers in flight in a long-duration mission. The fire suppression methods mentioned above will be used to extinguish several fire scenarios that have been identified as the most relevant to spaceflight, such as overheated wires, cable bundles, and circuit boards, as well as burning cloth and paper. Further testing will be conducted in which obstructions and ventilation will be added to represent actual spacecraft conditions (e.g., a series of cards in a card rack).

Abbud-Madrid, Angel↗

Spacecraft Fire Safety Research at NASA Glenn Research Center

Appropriate design of fire detection systems requires knowledge of both the expected fire signature and the background aerosol levels. Terrestrial fire detection systems have been developed based on extensive study of terrestrial fires. Unfortunately there is no corresponding data set for spacecraft fires and consequently the fire detectors in current spacecraft were developed based upon terrestrial designs. In low gravity, buoyant flow is negligible which causes particles to concentrate at the smoke source, increasing their residence time, and increasing the transport time to smoke detectors. Microgravity fires have significantly different structure than those in 1-g which can change the formation history of the smoke particles. Finally the materials used in spacecraft are different from typical terrestrial environments where smoke properties have been evaluated. It is critically important to detect a fire in its early phase before a flame is established, given the fixed volume of air on any spacecraft. Consequently, the primary target for spacecraft fire detection is pyrolysis products rather than soot. Experimental investigations have been performed at three different NASA facilities which characterize smoke aerosols from overheating common spacecraft materials. The earliest effort consists of aerosol measurements in low gravity, called the Smoke Aerosol Measurement Experiment (SAME), and subsequent ground-based testing of SAME smoke in 55-gallon drums with an aerosol reference instrument. Another set of experiments were performed at NASAs Johnson Space Center White Sands Test Facility (WSTF), with additional fuels and an alternate smoke production method. Measurements of these smoke products include mass and number concentration, and a thermal precipitator was designed for this investigation to capture particles for microscopic analysis. The final experiments presented are from NASAs Gases and Aerosols from Smoldering Polymers (GASP) Laboratory, with selected results focusing on realistic fuel preparations and heating profiles with regards to early detection of smoke. SAFFIRE is the upcoming large-scale fire experiment which will be executed in a Cygnus vehicle after it undocks from the ISS.

Aerosol↗

Multiplexed Optical Fiber Sensors for Coal Fired Advanced Fossil Energy Systems

This report summarizes technical progress on the program Multiplexed Optical Fiber Sensors for Coal Fired Advanced Fossil Energy Systems funded by the National Energy Technology Laboratory of the U.S. Department of Energy, and performed jointly by the Center for Photonics Technology of the Bradley Department of Electrical and Computer Engineering and the Department of Materials Science and Engineering at Virginia Tech. This three-year project started on October 1, 2008. In the project, a fiber optical sensing system based on intrinsic Fabry-Perot Interferometer (IFPI) was developed for strain and temperature measurements for Ultra Supercritical boiler condition assessment. Investigations were focused on sensor design, fabrication, attachment techniques and novel materials for high temperature and strain measurements. At the start of the project, the technical requirements for the sensing technology were determined together with our industrial partner Alstom Power. As is demonstrated in Chapter 4, all the technical requirements are successfully met. The success of the technology extended beyond laboratory test; its capability was further validated through the field test at DOE NETL, in which the sensors yielded distributed temperature mapping of a testing coupon installed in the turbine test rig. The measurement results agreed well with prior results generated with thermocouples. In this project, significant improvements were made to the IFPI sensor technology by splicing condition optimization, transmission loss reduction, sensor signal demodulation and sensor system design.

01 COAL, LIGNITE, AND PEAT↗

Unexpected Control Structure Interaction on International Space Station

On June 23, 2011, the International Space Station (ISS) was performing a routine 180 degree yaw maneuver in support of a Russian vehicle docking when the on board Russian Segment (RS) software unexpectedly declared two attitude thrusters failed and switched thruster configurations in response to unanticipated ISS dynamic motion. Flight data analysis after the maneuver indicated that higher than predicted structural loads had been induced at various locations on the United States (U.S.) segment of the ISS. Further analysis revealed that the attitude control system was firing thrusters in response to both structural flex and rigid body rates, which resonated the structure and caused high loads and fatigue cycles. It was later determined that the thruster themselves were healthy. The RS software logic, which was intended to react to thruster failures, had instead been heavily influenced by interaction between the control system and structural flex. This paper will discuss the technical aspects of the control structure interaction problem that led to the RS control system firing thrusters in response to structural flex, the factors that led to insufficient preflight analysis of the thruster firings, and the ramifications the event had on the ISS. An immediate consequence included limiting which thrusters could be used for attitude control. This complicated the planning of on-orbit thruster events and necessitated the use of suboptimal thruster configurations that increased propellant usage and caused thruster lifetime usage concerns. In addition to the technical aspects of the problem, the team dynamics and communication shortcomings that led to such an event happening in an environment where extensive analysis is performed in support of human space flight will also be examined. Finally, the technical solution will be presented, which required a multidisciplinary effort between the U.S. and Russian control system engineers and loads and dynamics structural engineers to develop and implement an extensive modification in the RS software logic for ISS attitude control thruster firings.

Gomez, Susan F.↗

RECOVER: An Automated Cloud-Based Decision Support System for Post-fire Rehabilitation Planning

RECOVER is a site-specific decision support system that automatically brings together in a single analysis environment the information necessary for post-fire rehabilitation decision-making. After a major wildfire, law requires that the federal land management agencies certify a comprehensive plan for public safety, burned area stabilization, resource protection, and site recovery. These burned area emergency response (BAER) plans are a crucial part of our national response to wildfire disasters and depend heavily on data acquired from a variety of sources. Final plans are due within 21 days of control of a major wildfire and become the guiding document for managing the activities and budgets for all subsequent remediation efforts. There are few instances in the federal government where plans of such wide-ranging scope and importance are assembled on such short notice and translated into action more quickly. RECOVER has been designed in close collaboration with our agency partners and directly addresses their high-priority decision-making requirements. In response to a fire detection event, RECOVER uses the rapid resource allocation capabilities of cloud computing to automatically collect Earth observational data, derived decision products, and historic biophysical data so that when the fire is contained, BAER teams will have a complete and ready-to-use RECOVER dataset and GIS analysis environment customized for the target wildfire. Initial studies suggest that RECOVER can transform this information-intensive process by reducing from days to a matter of minutes the time required to assemble and deliver crucial wildfire-related data.

cloud computing↗

Risk-Informed Systems Analysis (RISA) Dynamic Fire PRA Roadmap

Modeling and implementing fire safety for nuclear power plants is a costly activity. Because of the complexity of fire phenomenon and multiple operational procedures, it is difficult to computationally provide assurance that the mitigation methods are adequate for critical areas using current analysis methods. An economical method to provide more accurate modeling and optimize mitigation methods is needed to improve nuclear power viability. This report describes the initial investigation into modeling and simulation tools for application of fire as part of the Risk-Informed Systems Analysis (RISA), formerly Risk-Informed Safety Margin Characterization (RISMC). The report provides a framework of how 3D modeling and simulation techniques could be combined with a dynamic Probabilistic Risk Analysis (PRA) to reduce compounding conservatism present in current Fire PRA methods. Electrical Power Research Institute has analyzed current Fire PRA practices and identified the most significant contributors to risk and areas for improving analysis. This framework describes how to apply dynamic PRA and simulation methods for key contributors/scenarios, credit missing factors of manual fire suppression, and applying conditional probabilities.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Summary of Oxy Boiler Design Guidelines and Design Considerations (Topical Report- Recovery Act: Oxy-Combustion Technology Development for Industrial-Scale Boiler Applications)

This Topical Report outlines guidelines and key considerations for design and operation of pulverized coal-fired boilers for oxy-combustion. The scope addressed includes only the boiler island, not the entire oxy-fired CO 2 capture plant. These guidelines are primarily developed for tangential-fired boilers and focus on designs capable of dual air and oxy-fired operation. The guidelines and considerations discussed are applicable to both new units and existing boiler retrofits. These guidelines are largely based on the findings from the extensive 15 MW th pilot testing and design efforts conducted under this project. A summary level description is provided for each major aspect of boiler design impacted by oxy-combustion, and key considerations are discussed for broader application to different utility and industrial designs. Guidelines address the boiler system arrangement, firing system, boiler thermal design, ducting, materials, control system, and other key systems.

42 ENGINEERING↗

Evaluation of Gas, Oil and Wood Pellet Fueled Residential Heating System Emissions Characteristics

This study has measured the emissions from a wide range of heating equipment burning different fuels including several liquid fuel options, utility supplied natural gas and wood pellet resources. The major effort was placed on generating a database for the mass emission rate of fine particulates (PM 2.5) for the various fuel types studied. The fine particulates or PM 2.5 (less than 2.5 microns in size) were measured using a dilution tunnel technique following the method described in US EPA CTM-039. The PM 2.5 emission results are expressed in several units for the benefit of scientists, engineers and administrators. The measurements of gaseous emissions of O{sub 2}, CO{sub 2}, CO, NO{sub x} and SO{sub 2} were made using a combustion analyzer based on electrochemical cells These measurements are presented for each of the residential heating systems tested. This analyzer also provides a steady state efficiency based on stack gas and temperature measurements and these values are included in the report. The gaseous results are within the ranges expected from prior emission studies with the enhancement of expanding these measurements to fuels not available to earlier researchers. Based on measured excess air levels and ultimate analysis of the fuel's chemical composition the gaseous emission results are as expected and fall within the range provided for emission factors contained in the US-EPA AP 42, Emission Factors Volume I, Fifth Edition. Since there were no unexpected findings in these gaseous measurements, the bulk of the report is centered on the emissions of fine particulates, or PM 2.5. The fine particulate (PM 2.5) results for the liquid fuel fired heating systems indicate a very strong linear relationship between the fine particulate emissions and the sulfur content of the liquid fuels being studied. This is illustrated by the plot contained in the first figure on the next page which clearly illustrates the linear relationship between the measured mass of fine particulate per unit of energy, expressed as milligrams per Mega-Joule (mg/MJ) versus the different sulfur contents of four different heating fuels. These were tested in a conventional cast iron boiler equipped with a flame retention head burner. The fuels included a typical ASTM No. 2 fuel oil with sulfur below 0.5 percent (1520 average ppm S), an ASTM No. 2 fuel oil with very high sulfur content (5780 ppm S), low sulfur heating oil (322 ppm S) and an ultra low sulfur diesel fuel (11 ppm S). Three additional oil-fired heating system types were also tested with normal heating fuel, low sulfur and ultralow sulfur fuel. They included an oil-fired warm air furnace of conventional design, a high efficiency condensing warm air furnace, a condensing hydronic boiler and the conventional hydronic boiler as discussed above. The linearity in the results was observed with all of the different oil-fired equipment types (as shown in the second figure on the next page). A linear regression of the data resulted in an Rsquared value of 0.99 indicating that a very good linear relationship exits. This means that as sulfur decreases the PM 2.5 emissions are reduced in a linear manner within the sulfur content range tested. At the ultra low sulfur level (15 ppm S) the amount of PM 2.5 had been reduced dramatically to an average of 0.043 mg/MJ. Three different gas-fired heating systems were tested. These included a conventional in-shot induced draft warm air furnace, an atmospheric fired hydronic boiler and a high efficiency hydronic boiler. The particulate (PM 2.5) measured ranged from 0.011 to 0.036 mg/MJ. depending on the raw material source used in their manufacture. All three stoves tested were fueled with premium (low ash) wood pellets obtained in a single batch to provide for uniformity in the test fuel. Unlike the oil and gas fired systems, the wood pellet stoves had measurable amounts of particulates sized above the 2.5-micron size that defines fine particulates (less than 2.5 microns). The fine particulate emissions rates ranged from 22 to 30 mg/ MJ with an average value of 25 mg/MJ for the three stoves tested.

02 PETROLEUM↗

Detecting Anomalies for Fire Prevention in Distribution Systems: Challenges and Analytical Techniques

Electric utilities in California have historically been linked to up to 10% of wildfires. To mitigate this risk, Southern California Edison has invested significantly in wildfire prevention strategies, including undergrounding cables and enhancing equipment inspections. This article explores a novel approach to fire prevention by detecting anomalies in the distribution system that may indicate potential fire hazards. The focus is on identifying arcing conditions through high-resolution point-on-wave (POW) measurements. Arcing, a precursor to fires, is challenging to detect due to its subtle transients and complex system topology. The article discusses the use of advanced signal processing and machine learning techniques, such as spectral correlation function and discrete wavelet transform, to extract features from POW data and accurately identify arcing events. The study demonstrates a high accuracy rate in detecting arcing, paving the way for improved fire prevention measures in electric distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Emergency escape system protects personnel from explosion and fire

Elevator-type emergency escape system evacuates personnel from tall structures, especially when the possibility of explosion or fire exists. The system consists of a spike shaped rescue cabin which descends along a vertical guide cable, penetrates the dome shaped roof of an underground blast shelter and stops in a deceleration bed of granular material.

Offik, W. G.↗

Life cycle assessment of biochar produced from forest residues using portable systems

Forest fires are getting extreme and more frequent because of increased fuel loads in the forest and extended dry conditions. Fuel treatment (i.e., thinning) methods to mitigate forest fires will generate large volumes of forest residues together with available logging residues that can be used to produce biochar. It has been proposed that portable biochar systems are economical means to utilize forest residues as an alternative to slash burning. In this study, the environmental impacts of biochar produced from forest residues using three portable systems [1. Biochar Solutions Incorporated (BSI), 2. Oregon Kiln, and 3. Air-curtain Burner] were evaluated using a cradle-to-gate life-cycle assessment approach. Environmental impacts were analyzed considering the various quality of feedstock, biomass collection methods, different production sites, and various sources of power used in the production of biochar. The results illustrate that the global warming potential (GWP) of biochar production from forest residues through BSI, Oregon Kiln, and Air-Curtain Burner were 0.25–0.31, 0.11, and 0.16 tonne CO 2 eq./tonne of fixed carbon in biochar respectively. Compared to pile burn, biochar production from forest residues with a portable system at the landing, reduced global warming potential (GWP) by 1.92–2.83, 2.7, and 1.9 tonnes CO 2 eq./tonne of biochar through BSI, Oregon Kiln, and Air-Curtain Burner respectively. The Air-Curtain Burner and Oregon Kiln have minimal feedstock preparation, thus have lower environmental impacts than the BSI system. The BSI system requires feedstock preparation and power to operate the system. The use of the biomass-gasifier generator improved the environmental performance substantially (16–280%) compared with a diesel generator in biochar production. Overall, the net GWP in biochar produced (0.10–1.63 tonne CO 2 eq./tonne of residues) from forest residues can reduce environmental impacts (2–40 times lower net CO 2 eq. emissions) compared to slash burning.

54 ENVIRONMENTAL SCIENCES↗