Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FeO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

179 records · Page 10

Ba₁₋ₓSrₓFeO₃₋ᵧ as an Improved Oxygen Carrier for Chemical Looping Air Separation: A Computational and Experimental Study

Chemical looping air separation (CLAS) is a promising method to generate pure carbon-dioxide from fuel combustion with a pure oxygen stream, which is produced through the capture, and targeted release, of oxygen from the atmosphere using a solid oxide carrier. The performance of this process depends on the redox characteristics of the oxide carrier. Using experimental oxygen-temperature-programmed desorption (TPD) and thermogravimetric analysis (TGA), the study shows that Ba₀․₇₅Sr₀․₂₅FeO₃ has improved oxygen storage capacity (OSC), oxidation, and reduction kinetics over pristine SrFeO₃ at temperatures ranging from 300-500 °C. The redox energetics computed by using first-principles density functional theory (DFT) calculations also depict the measured trend establishing it as an important descriptor of the measured performance. The Ba₁₋ₓSrₓFeO₃₋ᵧ depicts a Sr-substitution and oxygen stoichiometry induced structural phase transition from hexagonal at low temperatures to pseudo-cubic phase with higher OSC up to T=400 °C. Also, the mechanism leading to this structural phase transition is identified by performing electronic and vibrational structural calculations. This presentation was given on March 8, 2024 at the APS March Meeting in Minneapolis, MN.

Acharya, Shree Ram↗

Microwave-Assisted Co-Gasification of Mixed Plastics and Corn Stover to Produce Clean Hydrogen Using Fe-Based Catalyst

Microwave-assisted gasification is an energy-efficient alternative to conventional gasification in which known feedstocks can be converted into syngas, char, and other byproducts to produce clean hydrogen at lower temperatures (~550 °C) through selective heating. Fe oxides are well-known gasification catalysts that can reduce in-situ to activate the methyl radicals by supplying surface oxygen and promoting H2 formation. This study introduces Fe2O3 as a microwave-active catalyst to enhance H2 production and tar reduction for plastic-corn stover co-gasification. The results found that the microwave reaction at 800 °C produced 24 times more mmol of hydrogen per kWh energy as compared to the conventional run at 900 °C. The X-ray diffraction results show the presence of Fe3O4 and FeO peaks indicating reduction of Fe2O3 to help devolatize reaction intermediates; while the appearance of metallic Fe in the microwave run at 800 °C indicates that Fe2O3 achieves full reduction at the microwave gasification temperature yielding maximum hydrogen production.

Abedin, Ashraf↗

The Position Index of Overhead LED Sources Under Different Spectral Power Distributions and Background Luminances

The position index was developed by Luckiesh and Guth in 1949 and is widely used in discomfort glare models to account for the position of the glare source when predicting the presence and magnitude of visual discomfort. The applicability of this index to modern LED sources has not been evaluated; however, it is of concern due to potentially higher luminance levels of LEDs compared to the sources used by Luckiesh and Guth. Furthermore, the position index of overhead sources beyond 60° above the line of sight has not been quantified. An experiment was conducted using a hemispherical apparatus with LED sources. The position of the light source, background luminance, the spectral power distribution, and anchor (starting luminance level before adjustment) were varied and two procedures were used to determine the position index of these sources. Data from 29 participants indicate that overhead sources located 60° or 80° above the line of sight were detectable and their position index can be quantified. The position index values were found to be higher than those reported in previous studies, suggesting that anchor bias and the small luminance range in previous studies likely influenced their position index values. No differences were found in position index values by spectral power distribution, background luminance, participant age group, or eyeglass wearing. In conclusion, the position index values reported in this study account for range and anchor bias, providing a better estimate that should be incorporated into discomfort glare models.

Discomfort glare↗

Relative Contributions of sc-DER, mel-DER, Color Rendition, Chromaticity, and Illuminance to Spatial Brightness Perception

An experiment was conducted to examine spectrally based factors that contribute to the visual perception of interior environments, with a focus on brightness perception. Thirty-two participants evaluated 60 different lighting scenes in a mock office. The lighting spectral power distributions varied systematically in illuminance, chromaticity (CCT and Duv), s cone opic daylight efficacy ratio (sc-DER), melanopic daylight efficacy ratio (mel-DER), and color rendition (R f , R g , and R cs,h1 ). At the operationalized levels of these variables, illuminance had the largest effect on brightness perception. Notably, the second largest effect was due to changes in red chroma (R cs,h1 ). The effect of sc-DER was also statistically significant but was a tertiary effect. The effects of mel-DER, CCT, and Duv were not statistically significant. This large effect of red chroma is consistent with the existing understanding that changes in color perception are often perceived when illuminance changes. In conclusion, with appropriate changes in color rendition and other factors held constant, spatial brightness perception was preserved through a decrease from 500 lux to 250 lux.

42 ENGINEERING↗

Custom Accessors: Enabling Scalable Data Ingestion, (Re-)Organization, and Analysis on Distributed Systems

The emerging class of high velocity and high volume data analytic workflows comprise interwoven data ingestion, organization, and processing stages, with ingestion and organization steps often contributing comparable or even higher computational costs than actual processing steps. Since complex workflows consist of a variety of phases that view and use data differently, being able to construct efficient, scalable, distributed data structures (arrays, vectors, sets, maps, and multi-maps) is essential and requires custom methods to extend and shrink containers, analyze and position data, and, maintain globallyconsistent meta-data. In this paper, we propose a novel datastructure access paradigm based on the concept of Accessors. At a high level, accessors are customizable callable objects that can modify the behavior of insert, read, update, and delete operations for distributed containers while preserving atomicity guarantees. Accessors provide a very clean and natural way to implement a variety of programming patterns, e.g., conditional insertion/deletion and cascading computations, which would be otherwise hard (or even impossible) to express in parallel and distributed settings without using locks. We demonstrate the practicality and usefulness of our approach with two representative use cases and study the performance of these applications on a distributed High-Performance Computing system. Our analysis highlights that our proposed abstraction allows for an effective overlapping and concurrent execution of different workflow steps (e.g., data ingestion and analysis), which in a conventional analytics pipeline would execute sequentially, contributing cumulatively to the overall latency.

Castellana, Vito G. [BATTELLE (PACIFIC NW LAB)] (O↗

Exploring Architectural-Aware Affinity Policies in Modern HPC Runtimes

Modern commodity and High-Performance Computing (HPC) systems are evolving with complex CPU architectures. These architectures now feature higher core and NUMA domain counts and implement features such as hyperthreading. When considering significant differences in hardware configurations, library availability, and hardware-tailored system/software stacks, which could substantially vary from one system to another, performance portability is hard to achieve. Throughout the years, this trend resulted in an increasingly high burden on application developers to fine-tune their workloads for each architecture. This work explores how hardware-dependent aspects such as locality/process/thread affinity affect performance in modern CPU architectures. We focus our study on the Global Memory and Threading (GMT) distributed runtime system as a representative of Partitioned Global Address Space (PGAS) software stacks commonly adopted for productivity. In particular, to appreciate performance implications, we evaluate GMT’s thread affinity policies, and, introduce two new ones which exploit architectural awareness. Finally, we explore alternative NUMA configurations via different process bindings and perform a scalability study on three HPC clusters with varying CPU architectures and NUMA layouts. Our analysis indicates that more complex architectures are more affected by affinity and binding policies and highlights the importance of setting proper runtime configurations to achieve superior performance.

Di Dio Lavore, Ian↗

DIMPLES: Distributed Influence Maximization for Pandemic pLanning on Exascale Systems

We study exascale parallel algorithms for the selection of intervention or monitoring strategies in massive realistic socio-technical networks through scalable Influence Maximization (InfMax) algorithms. We employ novel techniques to enable efficient scaling on up to 8k nodes of OLCF Frontier, with 65k AMD GPUs and 458k AMD CPU cores. Current state-of-the-art InfMax tools are limited to networks with only a few million actors (vertices) and a few hundred million interactions (edges). By overcoming these limitations, we show that our approach is capable of processing a realistic social contact network of the United States with 285 million nodes and about 8 billion edges. This two orders-of-magnitude improvement over the previous state-of-the-art is obtained by leveraging algorithmic advancements for the InfMax problem and designing several problem-specific approaches to overlap communication with computation, improve GPU efficiency, and lower the application’s memory requirements. We evaluate strong scaling for computing 10k most influential seeds using up to 8k nodes of an exascale system, and weak scaling from 128 to 8k system nodes for seed sets ranging from 625 to 40k seeds. We achieve the fastest-known runtime of 25 minutes while performing 48 million diffusion simulations totaling 2.31 petabytes to identify 40k influential seeds using 8k nodes, and take 5.75 minutes to identify 10k seeds while using 4k nodes.

Minutoli, Marco [Pacific Northwest National Labora↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. This type of product is mounted to upper walls or ceilings to treat air in the portion of the room above occupants; this allows for safe use of the room when the device is operating, but requires sufficient air mixing between upper and lower portions of the room. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance data allowed for comparison against manufacturer or vendor claims if the tested products included such claims. Some products had no performance data available for a given quantity (e.g., UV-C output power), and only four of the eight luminaires had radiant intensity distribution data files in a standard format (e.g., IES LM-63) available for download from product websites. The lack of publicly available performance data makes it difficult for potential buyers and specifiers to identify suitable products and design GUV systems for their specific applications. When products had performance claims, they were sometimes contradictory (e.g., unexplained differences between multiple power values) or ambiguous (e.g., measurement units conflict with quantity, unclear whether luminaire power or lamp power, unclear whether UV output power or UV-C output power). Three of the eight tested luminaires had claimed output power (i.e., radiant flux) values that exceeded measured values by more than an order of magnitude. There was substantial variation in UV-C radiant efficiency, with a measured range of 0.3–1.9% for LED and 0.4–2.1% for LPM, as shown in Figure 1. For example, the LPM luminaire with 0.4% radiant efficiency would need 5 times the amount of electrical energy used by the LPM luminaire with 2.1% radiant efficiency to produce the same amount of UV-C output power. LPM luminaires that had parabolic reflectors aligned with inclined louvers exhibited substantially higher UV-C radiant efficiency than tested luminaires with other designs, potentially cutting energy use by 75%. These results indicate a substantial opportunity for more energy efficient LPM luminaire designs, while demonstrating that UV LED luminaires can offer comparable UV-C radiant efficiency in this application. This may seem surprising, given that LED emitters have lower UV-C radiant efficiency than LPM lamps, but the efficiency-throttling louvers that are generally required for LPM luminaires typically are not needed for LEDs thanks to their directionality. However, lateral beam angles (which describe beam width as viewed from above) were 41–83° for LED luminaires versus 89–110° for LPM luminaires. More luminaires may be required if their lateral beam angles are relatively small, and coverage may be poor if UV-C radiant intensity distribution (i.e., beam shape) is not considered when designing systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

The Effect of Luminance Pattern on Nighttime Discomfort Glare Response (CRADA Final Report)

LED luminaires with apertures containing visually resolvable “bright” (i.e., high luminance) spots are commonly used to illuminate outdoor environments. However, the impact of the distance between LEDs, which determines spatial frequency at a given viewing distance, on perceived discomfort caused by these luminaires remains unclear. This study involved 29 participants who were each shown 68 stimuli varying in spatial frequency, intensity, diffusion level, and ambient lighting in a dark laboratory setting. Participants reported their experiences of discomfort from glare, ability to resolve individual LEDs, and afterimages. The findings revealed that increased spatial frequency heightened both discomfort and the likelihood of experiencing afterimages. It is hypothesized that the point spread function of the eye contributed to these effects, where sources began to be perceived as a single larger source with equal or greater intensity. These results suggest that LED luminaire designs should favor configurations with lower spatial frequencies to minimize discomfort. A simple quantity, direct illuminance at the eye, is recommended for use to predict discomfort from glare because it performed like other more complex models.

59 BASIC BIOLOGICAL SCIENCES↗

Radiometric Testing of Germicidal UV Products, Round 2: Upper-Room Luminaires (CALiPER Report)

This report analyzes the independently tested performance of eight germicidal ultraviolet (GUV) upper-room luminaires marketed for use in occupied spaces and purchased between March and June 2023. Three of the luminaires used UV-emitting LEDs, and the remaining five luminaires used low-pressure mercury (LPM) lamps. Product testing covered radiometric and electrical performance for each luminaire. Initial performance was measured for all eight products, and four were additionally measured after 100 h and 500 h of operation. Measured performance was compared against manufacturer or vendor claims. Specifiers and buyers of GUV products need accurate performance claims and data to deploy GUV technology safely and effectively. As with the CALiPER GUV Round 1 report, this CALiPER GUV Round 2 report demonstrates that manufacturers and vendors need significant education and training to accurately test and report the performance of their GUV products. Further development of industry consensus standards and guidelines may address testing limitations and improve test methods, product performance, and the accuracy of performance claims.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Review of the Use of Wearables in Indoor Environmental Quality Studies and an Evaluation of Data Accessibility from a Wearable Device

An understanding of indoor environmental quality (IEQ) and its effects on occupant well-being can inform building system design and operation. The use of wearables in field studies to collect subjective and objective health performance indicators (HPIs) from a large number of occupants could deliver important improvements in IEQ. To facilitate the use of wearables in IEQ studies, there is a need to identify which HPIs should be collected and to evaluate data accessibility from these devices. To address this issue, a literature review of previous IEQ studies was conducted to identify relationships between different IEQ factors and HPIs, with a focus on HPIs that were collected using wearables. A preliminary assessment of data accessibility from a selected wearable device (Fitbit Versa 2) was performed and documented. The review suggested the need to further investigate and collect sleep quality parameters, heart rate, stress response, as well as subjective ratings of comfort using wearables. The data accessibility assessment revealed issues related to missing data points and data resolution from the examined device. A set of recommendations is outlined to inform future studies.

60 APPLIED LIFE SCIENCES↗

Studying Response to Light in Offices: A Literature Review and Pilot Study

Researchers have been exploring the influence of light on health in office settings for over two decades; however, a greater understanding of physiological responses and technology advancements are shifting the way researchers study the influence of light in realistic environments. New technologies paired with Ecological Momentary Assessments (EMAs) administered via smartphones provide ways to collect information about individual light exposure and occupant response throughout the day. The study aims to document occupant response to tunable lighting in a real office environment, including potential beneficial or adverse health and well-being effects. Twenty-three office employees agreed to participate in a twelve-week study examining occupant response to two lighting conditions (static vs. dynamic). No significant differences were observed for any of the measures, highlighting the importance and complexity of in-situ studies conducted in realistic environments. While prior office studies have shown a significant influence on daytime sleepiness and sleep quality, research has not shown mood or stress to be significantly impacted by lighting conditions. Correlation analyses regarding lighting satisfaction, environmental satisfaction, and visual comfort demonstrate a significant relationship between certain items that may inform future studies. Further, the high correlation means it is reasonable to assume that many environmental factors in offices can influence occupant behavior and well-being.

60 APPLIED LIFE SCIENCES↗

Examining Perceptual Luminance Uniformity of Simulated Luminaire Patterns

Luminaire luminance uniformity is an important aspect that can affect perceived lighting quality, discomfort glare, and efficacy. While several metrics have been proposed to characterize luminance uniformity, previous studies have shown that current metrics such as Max:Min or Avg:Min luminance ratios can be insensitive to important differences in luminance gradient that may affect perceived uniformity. In an attempt to resolve this issue, previous studies incorporated a contrast sensitivity function for the human eye based on spatial frequency, such as in the UHVS metric; however, this metric has not been comprehensively studied in relation to perceived uniformity ratings. The study presented in this paper aimed to examine the relationship between the UHVS metric and perceived uniformity ratings. Specifically, the study used a web-based questionnaire that presented simulated luminance patterns and asked participants to assess uniformity using a two-alternative forced-choice procedure. Responses were collected and analyzed from 94 participants. The results showed a significant correlation and relationship between the UHVS metric and perceived uniformity. However, comparisons between patterns that had similar UHVS and between patterns that had larger differences in UHVS did not yield consistent results. These results suggest that the UHVS metric might be used for general guidance but may warrant further studies to better understand its sensitivity and improve its alignment with perceived uniformity ratings.

Abboushi, Belal K.↗

System and method of storing and analyzing information

A system and method of storing and analyzing information is disclosed. The system includes a compiler layer to convert user queries to data parallel executable code. The system further includes a library of multithreaded algorithms, processes, and data structures. The system also includes a multithreaded runtime library for implementing compiled code at runtime. The executable code is dynamically loaded on computing elements and contains calls to the library of multithreaded algorithms, processes, and data structures and the multithreaded runtime library.

Feo, John T.↗