Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fast Timing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Timing resolution and rate capability of Photonis miniPlanacon XPM85212/A1-S MCP-PMT

In this paper we report on a set of experiments that focus on measuring the timing performance of the Photonis miniPlanacon XPM85212/A1-S microchannel plate photomultiplier tubes along with the detector response at high event rates. The detector has a single photoelectron timing resolution of 30 ps at low rates ( 10 kHz ). We show that both the gain and the timing start to deteriorate around 1 MHz with 20 photoelectrons per channel at 1 0 4 target gain, giving the current per unit of area limits of 1.38 μ A / cm 2 and 2.38 μ A / cm 2 for the two tested devices. Photo-multiplier tubes with lower micro-channel plate resistivity exhibit a better rate capability due to the faster replenishment of the charge inside the microchannels. As we demonstrate, another method to improve the rate capability is to operate the photon detector tubes at a lower gain by reducing the supply voltage and compensating for the loss of amplitude by an additional amplification stage at the expense of the achieved timing resolution. The tube active area over which the beam is spread also plays a role since the same amount of light yields a better rate capability when spread over a larger area. The tubes exposed to high event rates showed an uncharacteristically slow recovery back to its initial gain with 80 % of the initial gain recovered only after several tens of minutes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Exploring Approaches for Accelerated Mass Spectrometric Detection of Fluorochemicals from Aqueous Solutions Using Indirect, Adsorbent-Facilitated Desorption Ionization

There is a growing need for rapid, low-cost analytical tools to screen water supplies for persistent contaminants. Due to their ubiquitous presence in the environment and their detrimental effects on human health, there is a public interest in widespread testing for perfluoroalkyl substances (PFAS). However, the most common methods for PFAS analysis can be time-intensive, requiring a preconcentration step followed by liquid chromatography–mass spectrometry (LC–MS), and are cost-prohibitive for most members of the public. To address these challenges, this study explores a novel method for rapid analysis of aqueous analytes by concentrating analytes on solid adsorbents and detecting them using mass spectrometric analysis via desorption ionization directly from the adsorbent surface. We demonstrate this general approach of indirect solution analysis (ISA) with desorption electrospray ionization (ISA-DESI) and laser desorption ionization (ISA-LDI). Various adsorbent materials were screened, including commercial mesoporous carbons, alumina, and metal–organic frameworks (MOFs). Using ISA-DESI, we consistently detect concentrations as low as 5–100 parts per trillion (ppt) for perfluorooctanoic acid (PFOA) and 10–100 ppt for perfluoroundecanoic acid (PFUnDA). This approach enables rapid detection in under 5 min, making it suitable for applications requiring trace detection with fast response times. We further demonstrate the use of ISA-DESI on a range of environmentally relevant contaminants. Advantages of this indirect solution analysis approach include simplified sample preparation, accelerated analysis, and low cost with readily available materials, making it a promising tool to accelerate mass spectrometric PFAS detection for identifying contaminated sites, performing laboratory studies, and monitoring industrial waste streams.

Bays, Nathan Robert [Sandia National Laboratories ↗

Characterization of the miniPlanacon XPM85112-S-R2D2 MCP-PMT with custom modified backend electronics

We report the results of the measurements of three pieces of the new Photonis miniPLANACON microchannel-plate photomultipliers (MCP-PMTs) intended for use in the demanding environment of the Large Hadron Collider (LHC) beamline as a part of the AFP Time-of-Flight detector. These photomultipliers were modified in cooperation with the manufacturer by using a custom backend and were subjected to numerous tests, with the focus on the rate capability and crosstalk behaviour. We determined that the two of them with a lower MCP resistance are able to operate without significant saturation at an anode current density of 1 μA/cm 2 . These two are, therefore, suitable for the intended use and are currently installed as part of the AFP detector packages.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pumped Storage Hydropower (PSH) FAST Commissioning Prize Technical Analysis

The US energy landscape has undergone major changes over the past 10 years and will continue to see significant changes in future decades as the power grid increases its reliance on variable renewable energy resources. Because of the inherent variability of these resources, renewable energy growth may require additional energy storage capacity to provide flexible load-following capabilities and other grid services that can quickly adjust to changes in energy demand and generation. Pumped storage hydropower (PSH)—one such energy storage technology—uses pumps to convey water from a lower reservoir to an upper reservoir for energy storage and releases water back to the lower reservoir via a powerhouse for hydropower generation. PSH facility pump and generation cycling often follows economic and energy demand conditions. Across the United States, 43 PSH facilities are in operation and 55 projects are in various permitting or licensing stages. Altogether, the 43 operational projects provide the wide majority (95%) of utility-scale electricity storage in the United States. These facilities also provide significant power and nonpower grid benefits, including large-scale electrical system reserve capacity, grid reliability support, and electricity supply-demand balancing through quick-response capabilities and operational flexibility. PSH systems can accomplish these at a scale (e.g., size) and cost that makes these systems highly attractive from a technical standpoint. Although these research concepts are still in their infancy, they demonstrate promising potential as future PSH energy storage technologies. Although PSH has many advantages, development in the United States has effectively stalled since the 1990s, partially because of the magnitude of project costs and financing interest during development and construction, the length of time from project investment until project revenue begins, permitting challenges, construction risks, competition from other storage technologies (e.g., batteries, hydrogen storage), and electricity market evolution and uncertainty. In short, the time, cost, and risk associated with modern PSH development have resulted in limited growth in the United States recently, despite the growing energy storage demand stemming from increased wind and solar power deployment. Technology innovation is needed to help reduce PSH commissioning time, cost, and risk, particularly during the post-licensing phase of project development. To address challenges facing the PSH industry and to improve PSH commissioning timelines, the US Department of Energy (DOE) Water Power Technologies Office (WPTO) initiated the PSH Furthering Advancements to Shorten Time to (FAST) Commissioning Prize project.

13 HYDRO ENERGY↗

Control of monodomain polymer-stabilized cuboidal nanocrystals of chiral nematics by confinement.

Liquid crystals are important components of optical technologies. Cuboidal crystals consisting of chiral liquid crystals-the so-called blue phases (BPs), are of particular interest due to their crystalline structures and fast response times, but it is critical that control be gained over their phase behavior as well as the underlying dislocations and grain boundaries that arise in such systems. Blue phases exhibit cubic crystalline symmetries with lattice parameters in the 100 nm range and a network of disclination lines that can be polymerized to widen the range of temperatures over which they occur. Here, we introduce the concept of strain-controlled polymerization of BPs under confinement, which enables formation of strain-correlated stabilized morphologies that, under some circumstances, can adopt perfect single-crystal monodomain structures and undergo reversible crystal-to-crystal transformations, even if their disclination lines are polymerized. We have used super-resolution laser confocal microscopy to reveal the periodic structure and the lattice planes of the strain and polymerization stabilized BPs in 3D real space. Our experimental observations are supported and interpreted by relying on theory and computational simulations in terms of a free energy functional for a tensorial order parameter. Simulations are used to determine the orientation of the lattice planes unambiguously. The findings presented here offer opportunities for engineering optical devices based on single-crystal, polymer-stabilized BPs whose inherent liquid nature, fast dynamics, and long-range crystalline order can be fully exploited.

confinement↗

Velocity Extraction Using Complete Time-Domain Waveform Data and Audio Machine Learning

We developed a new machine learning-based tool for extracting information from interferometry measurements: MIDWAZE (Modular Interferometry Direct Waveform AnalyZEr). This paper showcases MIDWAZE’s ability to extract an object’s velocity information from Photonic Doppler Velocimetry (PDV) data at near-human accuracy with little to no human intervention. MIDWAZE can extract velocities roughly 350 times as fast as a human analyst "rushing" to complete their extractions, with similar extraction accuracy. MIDWAZE’s most outstanding feature is that it operates directly in waveform/temporal space, freeing analysis from certain limitations imposed by traditional spectrogram-based approaches and opening the way to "phase aware" PDV analysis. MIDWAZE also has limited ability to discriminate between different solid objects, which we develop as a first step towards automated discrimination of different kinds of objects such as ejecta clouds.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

New method for level-lifetime measurements with thick scintillators

Level lifetimes provide key insight into the structure of atomic nuclei and serve as stringent tests of theoretical descriptions. Though several methods for determining level lifetimes exist for both reaction measurements and decay studies, here the focus is on techniques involving the direct measurement of time differences between population and subsequent depopulation of excited states. The techniques presented herein are broadly applicable across multiple timing ranges, but the approach is specifically described for the βγ timing method. A multi-step, amplitude-dependent time walk correction was employed to address the data analysis complications that arise from using thick scintillators for electron detection. Further, additional corrections for the depth of the interaction must also be performed when the parent isotope has been implanted into the detector. Techniques are presented for performing these time walk and depth of interaction corrections. Subsequently, a new Monte Carlo method utilizing measured detector responses obtained from the data, coupled with chi-square minimization, is presented for extracting excited state lifetimes ≳ 100 picoseconds. The framework of this Monte Carlo method is developed for the decay of a state in 68 Zn with a known 1.6 ps half life, which is considered prompt given the detection sensitivity of the technique, and then benchmarked using two other excited states in neutron-rich Ni isotopes with 120(34) ps and 1.05(3) ns half lives. Using this new method which takes into account the thick scintillator used, these same half lives were measured to be 135(10) ps and 1.04(24) ns, respectively. The overall good agreement demonstrates the validity of the technique.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of Advanced, Radiation Resistant, Optical-based Detector Technology for Future Experiments.

The primary objective of this project has been to advance the design of high-performance electromagnetic (EM) calorimeters for future particle physics experiments, to identify and measure the timing, position and energy of electrons, positrons and gamma rays, particularly in high-luminosity environments with intense radiation and pileup conditions. To meet such challenges, the proposed research has focused on the development of ultra-compact, radiation-hard calorimeter modules, to provide excellent timing, spatial, and energy resolution. The work aligns with the DOE’s Basic Research Needs (BRN) for High Energy Physics (HEP) Instrumentation and the research team contributes actively to the Coordinating Panel on Advanced Detectors (CPAD) RDC9 calorimetry collaboration in the USA and the European Committee on Future Accelerators (ECFA) DRD-CALO calorimetry collaboration at CERN, the European Laboratory for Particle Physics located in Geneva, Switzerland. The research builds on the RADiCAL (radiation-hard, ultra-compact) modular sampling calorimeter approach, developed by the research team, which employs dense and very bright optical materials such as LYSO:Ce scintillator plates that are interleaved with very dense tungsten plates to minimize detector size while optimizing performance. The modules are comparable in size to a human index finger, dimensionally 14 mm x 14 mm in cross section and 135 mm in length. And despite the small size, the structure is capable of providing excellent timing and energy resolution. This is facilitated through the use of specialized quartz capillaries filled with wavelength-shifting filaments, positioned at various depths along the length of a module, to collect and guide light signals to silicon photomultipliers (SiPMs) which detect and convert the optical signals to electronic signals for analysis. The primary goals of this project have been: (1) Achieve a timing resolution to σ t ≤ 30 ps for high-energy electrons and photons, important for their association with specific events produced in colliding-beam experiments and for the detection of decays-in-flight of long-lived particles. The project has achieved this goal in beam tests of a single RADiCAL module at CERN, during which a timing resolution of σ t = 27 ps was measured for electrons of energy E = 150 GeV. Based upon a mathematical fit to the data measured over a broad energy range from low energy to high energy, a resolution of σ t ≤ 18 ps has been estimated for electrons of very high (TeV) energy. From these measurements and with further expected technical improvements, the timing resolution should reach σ t ≤ 10 ps, important for searches for discovery physics in upcoming and future experiments. (2) Achieve an energy resolution of σ E / E ≤ 10% / $\sqrt{E}$. The project has yet to achieve this goal, but is close to it, having measured a value of σ E / E ≤ 15.9% / $\sqrt{E}$ using a modular array. Ultimately, the resolution goal is expected to be reached by adjustments to material thicknesses within the modules, which will improve the sampling fraction to measure more precisely the shower energy for lower energy particles. The versatility of the modular RADiCAL approach enables the testing of advanced materials, photosensors and electronics, developed in collaboration with CPAD RDC and ECFA DRD-CALO groups. The structure can distinguish electrons, positrons and gamma rays from hadrons and muons and beam-induced backgrounds, making it a valuable tool in a variety of detector environments, including future circular colliders (FCC-ee, FCC-hh) proposed for the European Laboratory for Particle Physics (CERN), the muon-collider proposed for Fermi National Accelerator Laboratory (Fermilab), and searches for new physics in beam-dump, fixed target and forward-physics experiments. And, while designed with particle physics applications in mind, the technologies developed in this project have the potential for application more broadly in particle and nuclear physics, materials science, and medical physics, underscoring the far-reaching potential of this line of instrumentation research and development.

47 OTHER INSTRUMENTATION↗

Cooling and Timing Tests of the ATLAS Fast TracKer VME Boards

The Fast TracKer (FTK) is an ATLAS trigger upgrade built for full-event, low-latency, high-rate tracking. The FTK core, made of 9U VME boards, performs the most demanding computational task. The associative memory board (AMB) serial link processor and the auxiliary card (AUX), plugged on the front and back sides of the same VME slot, constitute the processing unit (PU), which finds tracks using hits from eight layers of the inner detector. The PU works in pipeline with the second stage board (SSB), which finds 12-layer tracks by adding extra hits to the identified tracks. In the designed configuration, 16 PUs and four SSBs are installed in a VME crate. The high power consumption of the AMB, AUX, and SSB (respectively, of about 250, 70, and 160 W per board) required the development of a custom cooling system. Even though the expected power consumption for each VME crate of the FTK system is high compared with a common VME setup, the 8 FTK core crates will use ≈60 kW, which is just a fraction of the power and the space needed for a CPU farm performing the same task. We report on the integration of 32 PUs and eight SSBs inside the FTK system, on the infrastructures needed to run and cool them, and on the tests performed to verify the system processing rate and the temperature stability at a safe value.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Demonstration and analysis of volumetric additive manufacturing via sub-orbital spaceflight testing

Computed Axial Lithography (CAL) represents a significant advancement in the emerging field of Volumetric Additive Manufacturing (VAM). CAL addresses key limitations of traditional photopolymer additive manufacturing technologies, by eliminating the need for layering and support structures. Unlike conventional methods, CAL prints components by illuminating all points within a desired geometry simultaneously, using tomographic reconstruction to form the object in a single step. This unique approach eliminates the relative motion between the object and the precursor material, enabling faster printing speeds and reducing the waste associated with support structures. However, CAL parts require post-processing steps before they can be utilized. CAL's core attributes make it particularly suited for In-Space Manufacturing (ISM), due to its fast fabrication times, wide breadth of materials it can use, and minimized footprint. CAL has been successfully demonstrated in microgravity during parabolic flight experiments. However to fully validate and understand CAL's behaviour in microgravity, all manufacturing and post-processing steps must be integrated. In June 2024, we conducted SpaceCAL Mission 3, testing this entire workflow on a suborbital flight aboard Virgin Galactic's SpaceShipTwo. During ~140 s of microgravity, the system autonomously manufactured and post-processed four parts using PEGDA700 resin. Post-flight analysis showed that 2/4 parts were recognisable, while others were distorted due to bubble formation from residual water droplets, off-axis optical aberrations, and non-uniform solvent rinsing. Despite these limitations, this study represents the first integrated CAL workflow in space, providing an initial experimental demonstration and analysis for closed-loop in-space manufacturing.

Waddell, Taylor [Department of Mechanical Engineer↗

Voltage regulation in distribution grids: A survey

Environmental and sustainability concerns have caused a recent surge in the penetration of distributed energy resources into the power grid. This may lead to voltage violations in the distribution systems making voltage regulation more relevant than ever. Owing to this and rapid advancements in sensing, communication, and computation technologies, the literature on voltage control techniques is growing at a rapid pace in distribution networks. In particular, there is a paradigm shift from traditional offline centralized approaches to distributed ones leveraging increased and varied types of actuators, real-time sensing, fast and efficient computations, and an overall distributed situational awareness. This paper reviews state-of-the-art voltage control algorithms, summarizes the underlying methods, and classifies their coordination mechanisms into local, centralized, distributed, and decentralized. The underlying solution methodologies are further classified into two categories, open-loop and feedback-based. Two specific example workflows are provided to illustrate these solutions for voltage regulation.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Automated 3D cytoplasm segmentation in soft X-ray tomography

Cells’ structure is key to understanding cellular function, diagnostics, and therapy development. Soft X-ray tomography (SXT) is a unique tool to image cellular structure without fixation or labeling at high spatial resolution and throughput. Fast acquisition times increase demand for accelerated image analysis, like segmentation. Currently, segmenting cellular structures is done manually and is a major bottleneck in the SXT data analysis. This paper introduces ACSeg, an automated 3D cytoplasm segmentation model. ACSeg is generated using semi-automated labels and 3D U-Net and is trained on 43 SXT tomograms of immune T cells, rapidly converging to high-accuracy segmentation, therefore reducing time and labor. Furthermore, adding only 6 SXT tomograms of other cell types diversifies the model, showing potential for optimal experimental design. ACSeg successfully segmented unseen tomograms and is published on Biomedisa, enabling high-throughput analysis of cell volume and structure of cytoplasm in diverse cell types.

59 BASIC BIOLOGICAL SCIENCES↗

Distributed approximate minimal Steiner trees with millions of seed vertices on billion-edge graphs

In this report, we present a parallel 2-approximation Steiner minimal tree algorithm and its MPI-based distributed implementation. In place of expensive distance computations between all pairs of seed vertices, the solution we employ exploits a cheaper Voronoi cell computation. Our design leverages asynchronous processing and message prioritization to accelerate convergence of distance computations, and harnesses vertex and edge centric processing to offer fast time-to-solution. We demonstrate scalability and performance using real-world graphs with up to 128 billion edges and 512 compute nodes, and show the ability to find Steiner trees with up to one million seed vertices. Using 12 data instances, we present comparison with the state-of-the-art exact solver, SCIP-Jack, and two sequential 2-approximate algorithms. We empirically show that, on average, the total distance of the Steiner tree identified by our solution is 1.1290 times greater than the Steiner minimal tree – well within the theoretical approximation bound of 2.

97 MATHEMATICS AND COMPUTING↗

Extraordinarily large permittivity modulation in zinc oxide for dynamic nanophotonics

The dielectric permittivity of a material encapsulates the essential physics of light-matter interaction into the material's local response to optical excitation. Photo-induced modulation of the permittivity can enable an unprecedented level of control over the phase, amplitude, and polarization of light. Therefore, the detailed dynamic characterization of technology-relevant materials with substantially tunable optical properties and fast response times is a crucial step to realize tunable optical devices. This work reports on the extraordinarily large permittivity changes in zinc oxide thin films (up to similar to 3.6 relative change in the real part of the dielectric permittivity at 1600 nm wavelength) induced by optically generated free carriers. We demonstrate broadband reflectance modulation up to 70% in metal-backed oxide mirrors at the telecommunication wavelengths, with picosecond-scale relaxation times. The epsilon near zero points of the films can be dynamically shifted from 8.5 mm to 1.6 mm by controlling the pump fluence. Additionally, the modulation can be selectively enhanced at specific wavelengths employing metal-backed zinc oxide disks while maintaining picosecond-scale switching times. This work provides insights into the free-carrier assisted permittivity modulation in zinc oxide and could enable the realization of novel dynamic devices for beam-steering, polarizers, and spatial light modulators.

36 MATERIALS SCIENCE↗

Radiation hard gallium oxide scintillators for high count rate radiation detection

Despite decades of materials research, the availability of appropriate crystalline radiation-hard scintillators with ultrafast decay times (~10ns) and high light yields (>2000 ph/MeV) are still limited. In this study, we demonstrate the potential of gallium oxide (β-Ga 2 O 3 ) based scintillators for high count rate applications. The low-cost rugged β-Ga 2 O 3 scintillators were grown using the optical float zone (FZ) technique. Several dopants and growth atmospheres were used to demonstrate the balance between ultrafast primary decay time and the light yield of the scintillators. Light yields as high as 6446 ± 716 ph/MeV were obtained with 18.3 ns decay time for 662 keV gamma rays. Decay times as fast as 12ns were obtained with a 3212 ± 357 ph/MeV light yield. An excellent 662 keV gamma energy resolution of 7% was obtained using the β-Ga 2 O 3 :Ce crystals. Even with these excellent scintillation properties, the gamma radiation hardness of β-Ga 2 O 3 crystals was better than the leading radiation-hard lead tungstate (PbWO 4 ) crystals. Twenty-six scintillators fabricated from the grown β-Ga 2 O 3 crystals were tested for radiation hardness with a 60 Co gamma irradiation rate of 14 krad/h with a total radiation dose of 2 Mrad. The scintillation properties of these crystals remained unaffected. To date, no other scintillator has demonstrated such high radiation resistance. Furthermore, these FZ-grown low-cost, non-hygroscopic, and high-density β-Ga 2 O 3 scintillators can replace the existing scintillators in many applications ranging from nuclear and high energy physics experiments to nuclear security.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

A novel conditional formulation of the Vlasov–Ampère equations: a conservative, positivity, asymptotic and Gauss law preserving scheme

We propose a novel reformulation of the Vlasov–Ampère equations for plasmas that reveals discrete symmetries that enables simultaneous conservation of mass, momentum and energy; preservation of Gauss’s law; positivity of the distribution function; and consistency with quasi-neutral asymptotics. The approach employs variable and coordinate transformations to yield a coupled system comprising a modified Vlasov equation and associated moment–field equations. The modified Vlasov equation advances a conditional distribution function that excludes mass, momentum and energy densities, which are instead evolved through moment equations enforcing the relevant symmetries, conservation laws and involution constraints. This reformulation aligns naturally with a recent slow-manifold reduction technique, which separates fast electron time scales and simplifies the treatment of the quasi-neutral limit within the reduced moment–field subsystem. Using this framework, we develop a numerical method for the reduced 1D1V subsystem that, for the first time in the literature, satisfies all key physical constraints while maintaining a quasi-neutral asymptotic behaviour. The advantages of the method are demonstrated on canonical electrostatic test problems, including the multiscale ion acoustic shock wave.

1D1V↗

Computational Prediction of Coiled–Coil Protein Gelation Dynamics and Structure

Protein hydrogels represent an important and growing biomaterial for a multitude of applications, including diagnostics and drug delivery. We have previously explored the ability to engineer the thermoresponsive supramolecular assembly of coiled–coil proteins into hydrogels with varying gelation properties, where we have defined important parameters in the coiled–coil hydrogel design. Using Rosetta energy scores and Poisson–Boltzmann electrostatic energies, we iterate a computational design strategy to predict the gelation of coiled–coil proteins while simultaneously exploring five new coiled–coil protein hydrogel sequences. Provided this library, we explore the impact of in silico energies on structure and gelation kinetics, where we also reveal a range of blue autofluorescence that enables hydrogel disassembly and recovery. As a result of this library, we identify the new coiled–coil hydrogel sequence, Q5, capable of gelation within 24 h at 4 °C, a more than 2-fold increase over that of our previous iteration Q2. The fast gelation time of Q5 enables the assessment of structural transition in real time using small-angle X-ray scattering (SAXS) that is correlated to coarse-grained and atomistic molecular dynamics simulations revealing the supramolecular assembling behavior of coiled–coils toward nanofiber assembly and gelation. This work represents the first system of hydrogels with predictable self-assembly, autofluorescent capability, and a molecular model of coiled–coil fiber formation.

36 MATERIALS SCIENCE↗

Predicting Partial Atomic Charges in Metal–Organic Frameworks: An Extension to Ionic MOFs

Molecular simulation is an invaluable tool to predict and understand the usage of metal–organic frameworks (MOFs) for gas storage and separation applications. Accurate partial atomic charges, commonly obtained from density functional theory (DFT) calculations, are often required to model the electrostatic interactions between the MOF and adsorbates, especially when the adsorbates have dipole or quadrupole moments, such as water and CO 2 . Machine learning (ML) models have been previously employed to predict partial charges and avoid the computational cost associated with DFT calculations. However, previous ML models suffer from small training data sets, which limit their scope of application. In this work, we introduce two novel machine learning models, PACMOF2-neutral and PACMOF2-ionic, aimed at predicting the density-derived electrostatic and chemical (DDEC6) partial atomic charges for both neutral and ionic MOFs. These models not only yield DFT-level accuracy at a fraction of the computational cost but also demonstrate a remarkable improvement in prediction of adsorption, as validated with grand canonical Monte Carlo simulations. Furthermore, the robustness and fast computational time of the PACMOF2 models, along with their transferability to other porous materials such as covalent organic frameworks and zeolites, underscores their potential in high-throughput screening of MOFs for diverse applications.

36 MATERIALS SCIENCE↗