Measurement of velocity of light - use of interferometer
Magnetostrictively scanned interferometer for airborne recording of coronal temperatures during solar eclipse
Stars are observed with a ground-based instrument designed to measure small changes in the line-of-sight velocities. The purpose of the observations is to detect large planets by the oscillatory reflex motion they induce on the stars they are orbiting. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. Changes in the line-of-sight velocities are revealed by changes in the Doppler shift of the absorption-line spectra of stars. The scrambling of incident light by an optical fiber and the stability of wavelength calibration by a tilt-tunable Fabry-Perot etalon provide immunity to systematic errors that historically have effected more conventional radial velocity spectrographs. A cross-dispersed echelle spectrograph spatially separates the orders of constructive interference transmitted through the etalon. Selecting several echelle diffraction orders in the vicinity of 4250 to 4750 A, which are imaged on a CCD, about 350 points on the profile of the stellar spectrum are sampled by successive orders of interferometric transmission through the etalon.
Thermospheric wind data obtained from the Atmosphere Explorer E and Dynamics Explorer 2 satellites have been combined with wind data for the lower and upper thermosphere from ground-based incoherent scatter radar and Fabry-Perot optical interferometers to generate a revision (HWM90) of the HWM87 empirical model and extend its applicability to 100 km. Comparison of the various data sets with the aid of the model shows in general remarkable agreement, particularly at mid and low latitudes. The ground-based data allow modeling of seasonal/diurnal variations, which are most distinct at midlatitudes. While solar activity variations are now included, they are found to be small and not always very clearly delineated by the current data. They are most obvious at the higher latitudes. The model describes the transition from predominately diurnal variations in the upper thermosphere to semidiurnal variations in the lower thermosphere and a transition from summer to winter flow above 140 km to winter to summer flow below. Significant altitude gradients in the wind are found to extend to 300 km at some local times and pose complications for interpretation of Fabry-Perot observations.
Modified Al-dielectric-Al Fabry-Perot interference filter for isolating Hg 1849 angstrom emission line from Hg 2536 angstrom line
Optical determination of temperature variations throughout solar corona during eclipse of May 30, 1965
Isotope shift measurement for 6328 angstroms helium-neon laser transition
Tunable coupling of open waveguide type for semiconfocal Fabry-Perot cavity gives high transmission and high Q
The High Spectral Resolution Lidar (HSRL) system was developed for the remote measurement of atmospheric optical properties. Measurements are obtained by the separation of the backscattered signal into aerosol and molecular channels using a high spectral resolution Fabry-Perot optical interferometer to separate the aerosol contributions to backscatter near the laser wavelength from the Doppler-shifted molecular component of the backscatter. The transmitter consists of an optically pumped pulsed dye laser of the oscillator-amplifier design which emits at 467.88 nm, with a bandwidth of less than 0.3 pm. The transmitter and receiver share a common Schmidt-Cassegrain telescope, although they do not share the same field stop, but rather two conjugate stops. The HSRL system uses a computer-controlled dual-channel photon-counting data acquisition system providing for stable measurements at very low power levels and an excellent dynamic range. The system has been used to obtain airborne measurements of height profiles of aerosol and molecular backscatter cross sections.
A high spectral resolution lidar technique to measure optical scattering properties of atmospheric aerosols is described. Light backscattered by the atmosphere from a narrowband optically pumped oscillator-amplifier dye laser is separated into its Doppler broadened molecular and elastically scattered aerosol components by a two-channel Fabry-Perot polyetalon interferometer. Aerosol optical properties, such as the backscatter ratio, optical depth, extinction cross section, scattering cross section, and the backscatter phase function, are derived from the two-channel measurements.
Researchers are measuring small changes in the line-of-sight velocities of stars to detect the oscillating reflex acceleration induced by large planets. The intention is to observe enough stars for a long enough time to be able to make a statement of the probability of planets in a certain range of masses even if no planetary perturbations are detected. To make these measurements of Doppler shift with the required sensitivity, a new instrument was specifically designed, built and tested for this campaign of ground-based planet detection. The instrument is an optical spectrometer for which wavelengths are first calibrated by transmission through a tunable Fabry-Perot etalon interferometer. The intrinsic stability of the etalon and an image-scrambling fiber optic light feed provide great sensitivity to line-of-sight accelerations and immunity to systematic errors.
Explore the source record for details and available documents.
Description of an oscillating magnetic analyzer (KDP crystal plus Glan-Thompson prism) coupled to an echelle-interferometer spectrograph, and of single-slit magnetometer which by pressure variations can be made to scan the entire profiles of the circularly and linearly polarized Zeeman components. Freon gas is used as the scanner gas with wavelength displacements of 0.02 A per 0.1 in. Hg pressure change at the NaD lines. The available scan range is 15 A in the visual spectral region.
The mechanisms giving rise to certain airglow and auroral emissions and their height distribution are briefly surveyed. The basic principles of operation of scanning Fabry-Perot spectrometers are outlined in order to illustrate the calibration and use of such instruments to measure Doppler broadening and shift of atomic emission lines in the spectrum of the airglow and aurora and hence to infer atmospheric temperatures and wind velocities. Technical details of some specific instruments are given. Brief mention is made of the use of wide angle Michelson interferometers for the same application. Emphasis is given to the future importance of imaging Fabry-Perot spectrometers to permit the detailed mapping of temperature and wind velocity, especially in the auroral regions.
Remote displacement measurement is demonstrated using a Fabry-Perot cavity with a multimode optical fiber link. The sensing cavity modulates, as a function of its length, the spectrum of a light-emitting diode (LED). The light returns via the fiber and is analyzed by a tunable reference cavity. A closed-loop control causes the reference cavity to track the sensing cavity length within 2 x 10 to the -12th m. Displacement range is 2 x 10 to the -6th m. The reference cavity length is measured interferometrically, using a laser, to obtain the sensing cavity length. Advantages of this sensing technique include compatibility with multimode fiber-optic components, high immunity to optical losses, and large dynamic range.
We report the use of a short-length, multimode sapphire rod as an extension to a Michelson configuration, but operated as a low-finesse Fabry-Perot cavity. We demonstrate the performance of such a device as an interferometric sensor, where the interference between the reflections from the sapphire-air interface and an air-metallic surface is observed for microdisplacement of the metallic surface which is placed close to the sapphire endface. We describe in detail the fabrication procedure and present results obtained from the detection of temperature changes, applied strain, and surface acoustic waves.
The status of infrared instrumentation for astronomical investigations at U.C. Berkeley is described with emphasis on the techniques of high spectral and spatial resolution. Present instrumentation includes three Fabry-Perot spectrometers for the 10, 20, and 100 micron wavelength regions, a submillimeter receiver using an optically pumped laser, a 10 micron heterodyne spectrometer for studies of planetary atmospheres, and a 2-element 10 micron stellar interferometer for measuring the angular diameters of infrared stars.