Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FUNCTION TEST”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Liapunov stability analysis of spinning flexible spacecraft.

The attitude stability of a class of spinning flexible spacecraft in a force-free environment is analyzed. The spacecraft is modeled as a rigid core having attached to it a flexible appendage idealized as a collection of elastically interconnected particles. Liapunov stability theorems are employed with the Hamiltonian of the system, constrained through the angular momentum integral so as to admit complete damping, used as a testing function. The Hamiltonian is written in terms of modal coordinates as interpreted by the hybrid coordinate formulation, thus allowing truncation to a level amenable to literal stability analysis. Testing functions are constructed for a spacecraft with an arbitrary (discretized) appendage, and closed form stability criteria are generated for the first mode of a restricted appendage model lying in a plane which contains the center of mass and is orthogonal to the spin axis. The criteria are (except for idealized cases on the stability boundary line in the parameter space) both necessary and sufficient for stability for any spacecraft characterized by the planar appendage model, such as a spacecraft containing solar panels and/or radial booms.

Barbera, F. J.↗

Changes in Pulmonary Function After Three-Dimensional Conformal Radiotherapy, Intensity-Modulated Radiotherapy, or Proton Beam Therapy for Non-Small-Cell Lung Cancer

Purpose: To investigate the extent of change in pulmonary function over time after definitive radiotherapy for non-small-cell lung cancer (NSCLC) with modern techniques and to identify predictors of changes in pulmonary function according to patient, tumor, and treatment characteristics. Patients and Methods: We analyzed 250 patients who had received {>=}60 Gy radio(chemo)therapy for primary NSCLC in 1998-2010 and had undergone pulmonary function tests before and within 1 year after treatment. Ninety-three patients were treated with three-dimensional conformal radiotherapy, 97 with intensity-modulated radiotherapy, and 60 with proton beam therapy. Postradiation pulmonary function test values were evaluated among individual patients compared with the same patient's preradiation value at the following time intervals: 0-4 (T1), 5-8 (T2), and 9-12 (T3) months. Results: Lung diffusing capacity for carbon monoxide (DLCO) was reduced in the majority of patients along the three time periods after radiation, whereas the forced expiratory volume in 1 s per unit of vital capacity (FEV1/VC) showed an increase and decrease after radiation in a similar percentage of patients. There were baseline differences (stage, radiotherapy dose, concurrent chemotherapy) among the radiation technology groups. On multivariate analysis, the following features were associated with larger posttreatment declines in DLCO: pretreatment DLCO, gross tumor volume, lung and heart dosimetric data, and total radiation dose. Only pretreatment DLCO was associated with larger posttreatment declines in FEV1/VC. Conclusions: Lung diffusing capacity for carbon monoxide is reduced in the majority of patients after radiotherapy with modern techniques. Multiple factors, including gross tumor volume, preradiation lung function, and dosimetric parameters, are associated with the DLCO decline. Prospective studies are needed to better understand whether new radiation technology, such as proton beam therapy or intensity-modulated radiotherapy, may decrease the pulmonary impairment through greater lung sparing.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Functional Mobility Testing: A Novel Method to Create Suit Design Requirements

This study was performed to aide in the creation of design requirements for the next generation of space suits that more accurately describe the level of mobility necessary for a suited crewmember through the use of an innovative methodology utilizing functional mobility. A novel method was utilized involving the collection of kinematic data while 20 subjects (10 male, 10 female) performed pertinent functional tasks that will be required of a suited crewmember during various phases of a lunar mission. These tasks were selected based on relevance and criticality from a larger list of tasks that may be carried out by the crew. Kinematic data was processed through Vicon BodyBuilder software to calculate joint angles for the ankle, knee, hip, torso, shoulder, elbow, and wrist. Maximum functional mobility was consistently lower than maximum isolated mobility. This study suggests that conventional methods for establishing design requirements for human-systems interfaces based on maximal isolated joint capabilities may overestimate the required mobility. Additionally, this method provides a valuable means of evaluating systems created from these requirements by comparing the mobility available in a new spacesuit, or the mobility required to use a new piece of hardware, to this newly established database of functional mobility.

England, Scott A.↗

Taylor-Lagrange renormalization scheme: Application to light-front dynamics

The recently proposed renormalization scheme based on the definition of field operators as operator valued distributions acting on specific test functions is shown to be very convenient in explicit calculations of physical observables within the framework of light-front dynamics. We first recall the main properties of this procedure based on identities relating the test functions to their Taylor remainder of any order expressed in terms of Lagrange's formulas, hence the name given to this scheme. We thus show how it naturally applies to the calculation of state vectors of physical systems in the covariant formulation of light-front dynamics. As an example, we consider the case of the Yukawa model in the simple two-body Fock state truncation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Functional Task Tests in Partial Gravity during Parabolic Flight

Critical mission tasks that are required by crews immediately after landing on a planetary surface are seat egress, jump, and walk. To be able to define an effective and comprehensive countermeasure strategy for preserving crew performance during exploration-class missions, there is a need to understand how these functional tasks are actually performed in partial gravity such as on the Moon or Mars. We propose to study the performance of the execution of these tasks during partial gravity phases (0.25g, 0.5g, 0.75g) of parabolic flight.

Gilles R Clement↗

Instrumented Lid: Full Instrumentation System Testing

This report describes full system testing of an instrumentation system for the monitoring of aluminum clad spent nuclear fuel (ASNF). The requirements for this system were laid out in a previous document, with respect to former studies, and the details of project actualization were reported. The reader is directed to these references for more background information. In short, a team composed of personnel from Savannah River National Laboratory (SRNL) and Idaho National Laboratory have been tasked with the design and fabrication of an instrumented assembly for remote sampling, monitoring, and radiation testing (SMART) for demonstration and surveillance of the dry storage environment and conditions of ASNF in a DOE standardized canister. SRNL proposed the fabrication of two systems to accomplish this goal: 1) an instrumentation system consisting of gas and particle collection, temperature, humidity, pressure, and radiation monitoring; and 2) a lid assembly consisting of a custom-designed lid and hat, together with a custom fuel basket. The corresponding instrumentation system is shown in the piping and instrumentation diagram. The individual functionality tests of the instrument system sensor components were performed, and the results were reported in the report “Instrumented Lid- System Functionality Testing.” Savannah River National Laboratory, September 1, 2019.7 The sensor components of instrumentation system have been mounted and tested in-line with a 6” diameter test canister, and the results are reported in this document.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Comparison of imatinib, nilotinib and silymarin in the treatment of carbon tetrachloride-induced hepatic oxidative stress, injury and fibrosis

Effective and well-tolerated anti-fibrotic drugs are currently lacking. Therefore, this study was carried out to investigate the potential anti-fibrotic effects of imatinib, nilotinib and silymarin on established hepatic fibrosis in the carbon tetrachloride (CCl{sub 4}) rat model. Male Wistar rats received intraperitoneal injections of CCl{sub 4} twice weekly for 8 weeks, as well as daily intraperitoneal treatments of imatinib (10 and 20 mg/kg), nilotinib (10 and 20 mg/kg) and silymarin (100 mg/kg) during the last 4 weeks of CCl{sub 4}-intoxication. At the end of the study, hepatic damage was evaluated by analysis of liver function tests and hepatic oxidative stress parameters. Hepatic fibrosis was evaluated by histopathology and morphometry, as well as collagen and 4-hydroxyproline contents. Nilotinib (20 mg/kg) was the most effective treatment to counteract CCl{sub 4}-induced hepatic injury as indicated by liver function tests and histopathology. Nilotinib (10 mg/kg), nilotinib (20 mg/kg) and silymarin (100 mg/kg) treatments reduced the mean score of hepatic fibrosis by 31%, 68% and 47%, respectively, and hepatic collagen content by 47%, 49% and 18%, respectively in CCl{sub 4}-treated rats. Hepatic morphometric evaluation and 4-hydroxyproline content revealed that CCl{sub 4}-induced fibrosis was ameliorated significantly by nilotinib (20 mg/kg) and imatinib (20 mg/kg). Unlike nilotinib, imatinib (20 mg/kg) showed some sort of hepatic injury evidenced by elevation of serum aminotransferases and total bilirubin levels, and hepatic total nitrate/nitrite content, as well as characteristic anisonucleosis visualized with the hematoxylin-eosin staining. In conclusion, this study provides the evidence that nilotinib exerts anti-fibrotic activity and suggests that it may be valuable in the treatment of hepatic fibrosis in humans. - Graphical abstract: Display Omitted Research Highlights: > The anti-fibrotic effects of imatinib, nilotinib and silymarin were compared. > These effects were evaluated on CCl{sub 4}-induced hepatic fibrosis in rats. > Nilotinib was found to possess potent anti-fibrotic activity. > In addition, nilotinib did not show any signs of hepatotoxicity. > Thus, nilotinib may be valuable in the treatment of hepatic fibrosis in humans.

60 APPLIED LIFE SCIENCES↗

SAS4A/SASSYS-1 Verification Testing for Sodium Fast Reactor Application: Acceptance Testing Report

AS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over sixty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. To support the dedication effort, this report has been generated to provide a detailed description of the available verification testing. The verification testing presented in this report captures functionality testing, focusing mainly on the testing of specific functions and algorithms for accuracy and precision of output, and interface testing, focusing mainly on the testing of critical input parameters and their valid ranges. Although SAS was developed to support the analysis of any liquid-metal-cooled nuclear reactor, the testing described in this document primarily focuses on the verification of SAS capabilities as they relate to a generic pool-type Sodium Fast Reactor (SFR).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Contrasting actions of pressor agents in severe autonomic failure

BACKGROUND: Orthostatic hypotension is the most disabling symptom of autonomic failure. The choice of a pressor agent is largely empiric, and it would be of great value to define predictors of a response. PATIENTS AND METHODS: In 35 patients with severe orthostatic hypotension due to multiple system atrophy or pure autonomic failure, we determined the effect on seated systolic blood pressure (SBP) of placebo, phenylpropanolamine (12.5 mg and 25 mg), yohimbine (5.4 mg), indomethacin (50 mg), ibuprofen (600 mg), caffeine (250 mg), and methylphenidate (5 mg). In a subgroup of patients, we compared the pressor effect of midodrine (5 mg) with the effect of phenylpropanolamine (12.5 mg). RESULTS: There were no significant differences in the pressor responses between patients with multiple system atrophy or pure autonomic failure. When compared with placebo, the pressor response was significant for phenylpropanolamine, yohimbine, and indomethacin. In a subgroup of patients, we confirmed that this pressor effect of phenylpropanolamine, yohimbine, and indomethacin corresponded to a significant increase in standing SBP. The pressor responses to ibuprofen, caffeine, and methylphenidate were not significantly different from placebo. Phenylpropanolamine and midodrine elicited similar pressor responses. There were no significant associations between drug response and autonomic function testing, postprandial hypotension, or plasma catecholamine levels. CONCLUSIONS: We conclude that significant increases in systolic blood pressure can be obtained in patients with orthostatic hypotension due to primary autonomic failure with phenylpropanolamine in low doses or yohimbine or indomethacin in moderate doses. The response to a pressor agent cannot be predicted by autonomic function testing or plasma catecholamines. Therefore, empiric testing with a sequence of medications, based on the risk of side effects in the individual patient and the probability of a response, is a useful approach.

Clinical Trial↗

Changes in Global Function and Regional Ventilation and Perfusion on SPECT During the Course of Radiotherapy in Patients With Non-Small-Cell Lung Cancer

Purpose: This study aimed to (1) examine changes in dyspnea, global pulmonary function test (PFT) results, and functional activity on ventilation (V)/perfusion (Q) single-photon emission computerized tomography (SPECT) scans during the course of radiation (RT), and (2) factors associated with the changes in patients with non-small-cell lung cancer (NSCLC). Methods and Materials: Fifty-six stage I to III NSCLC patients treated with definitive RT with or without chemotherapy were enrolled prospectively. Dyspnea was graded according to Common Terminology Criteria for Adverse Events version 3.0 prior to and weekly during RT. V/Q SPECT-computed tomography (CT) and PFTs were performed prior to and during RT at approximately 45 Gy. Functions of V and Q activities were assessed using a semiquantitative scoring of SPECT images. Results: Breathing improved significantly at the third week (mean dyspnea grade, 0.8 vs. 0.6; paired t-test p = 0.011) and worsened during the later course of RT (p > 0.05). Global PFT results did not change significantly, while regional lung function on V/Q SPECT improved significantly after {approx}45 Gy. The V defect score (DS) was 4.9 pre-RT versus 4.3 during RT (p = 0.01); Q DS was 4.3 pre-RT versus 4.0 during RT (p < 0.01). Improvements in V and Q functions were seen primarily in the ipsilateral lung (V DS, 1.9 pre-RT versus 1.4 during RT, p < 0.01; Q DS, 1.7 pre-RT versus 1.5 during RT, p < 0.01). Baseline primary tumor volume was significantly correlated with pre-RT V/Q DS (p < 0.01). Patients with central lung tumors had greater interval changes in V and Q than those with more peripheral tumors (p <0.05 for both V and Q DS). Conclusions: Regional ventilation and perfusion improved during RT at 45 Gy. This suggests that adaptive planning based on V/Q SPECT during RT may allow sparing of functionally recoverable lung tissue.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Damper Spring Unit of the Sentinel 1 Solar Array

The Damper Spring Unit (DSU, see Figure 1) has been designed to provide the damping required to control the deployment speed of the spring driven solar array deployment in an ARA Mk3 or FRED based Solar Array in situations where the standard application of a damper at the root-hinge is not feasible. The unit consists of four major parts: a main bracket, an eddy current damper, a spring unit, an actuation pulley which is coupled via Kevlar cables to a synchro-pulley of a hinge. The damper slows down the deployment speed and prevents deployment shocks at deployment completion. The spring unit includes 4 springs which overcome the resistances of the damper and the specific DSU control cable loop. This means it can be added to any spring driven deployment system without major modifications of that system. Engineering models of the Sentinel 1 solar array wing have been built to identify the deployment behavior, and to help to determine the optimal pulley ratios of the solar array and to finalize the DSU design. During the functional tests, the behavior proved to be very sensitive for the alignment of the DSU. This was therefore monitored carefully during the qualification program, especially prior to the TV cold testing. During TV "Cold" testing the measured retarding torque exceeded the max. required value: 284 N-mm versus the required 247 N-mm. Although this requirement was not met, the torque balance analysis shows that the 284 N-mm can be accepted, because the spring unit can provide 1.5 times more torque than required. Some functional tests of the DSU have been performed without the eddy current damper attached. It provided input data for the ADAMS solar array wing model. Simulation of the Sentinel-1 deployment (including DSU) in ADAMS allowed the actual wing deployment tests to be limited in both complexity and number of tests. The DSU for the Sentinel-1 solar array was successfully qualified and the flight models are in production.

Doejaaren, Frans↗

Toxicity and Outcome Results of a Class Solution With Moderately Hypofractionated Radiotherapy in Inoperable Stage III Non-Small Cell Lung Cancer Using Helical Tomotherapy

Purpose: To prospectively assess the feasibility, toxicity, and local control of a class solution protocol of moderately hypofractionated tomotherapy in Stage III, inoperable, locally advanced non-small-cell lung cancer patients. Methods and Materials: Eligible patients were treated according to a uniform class solution (70.5 Gy in 30 fractions) with fixed constraints and priorities using helical tomotherapy. Toxicity monitoring was performed using the Radiation Therapy Oncology Group criteria and the National Cancer Institute Common Terminology Criteria and Adverse Events (CTCAE) version 3.0. Pulmonary function tests were performed at the start and repeated at 3 months after treatment. Results: Our class solution resulted in a deliverable plan in all 40 consecutive patients. Acute Grade 3 lung toxicity was seen in 10% of patients. Two patients died during acute follow-up with pulmonary toxicity. Correlations were found between changes in pulmonary function test results and mean lung dose or the lung volume receiving 20 Gy (V{sub 20}). The correlation was strongest for lung diffusion capacity for carbon monoxide. A V{sub 20} of >27% and >32% were predictive for Grades 2 and 3 acute lung toxicity respectively (p < 0.05). Late Grade 3 toxicity was exclusively pulmonary, with an incidence of 16%. Overall Grade 3 lung toxicity correlated with a mean lung dose of >18 Gy and a median lung dose of >5 Gy (p < 0.05). Median survival was 17 months, and the 1-year and 2-year local progression-free survivals were 66% and 50%, respectively. Conclusion: The current class solution using moderately hypofractionated helical tomotherapy in patients with locally advanced non-small-cell lung cancer is feasible. Toxicity was acceptable and in line with other reports on intensity-modulated radiotherapy. The local progression-free survival was encouraging considering the unselected population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quadratic exponential vectors

We give a necessary and sufficient condition for the existence of a quadratic exponential vector with test function in L{sup 2}(R{sup d}) intersection L{sup {infinity}}(R{sup d}). We prove the linear independence and totality, in the quadratic Fock space, of these vectors. Using a technique different from the one used by Accardi et al. [Quantum Probability and Infinite Dimensional Analysis, Vol. 25, p. 262, (2009)], we also extend, to a more general class of test functions, the explicit form of the scalar product between two such vectors.

97 MATHEMATICS AND COMPUTING↗

Testing and Functions of the J2X Gas Generator

The Ares I, NASA s new solid rocket based crew launch vehicle, is a two stage in line rocket that has made its waytothe forefront of NASA s endeavors. The Ares I s Upper Stage (US) will be propelled by a J-2X engine which is fueled by liquid hydrogen and liquid oxygen. The J-2X is a variation based on two of its predecessor s, the J-2 and J-2S engines. ET50 is providing the design support for hardware required to run tests on the J-2X Gas Generator (GG) that increases the delivery pressure of the supplied combustion fuels that the engine burns. The test area will be running a series of tests using different lengths and curved segments of pipe and different sized nozzles to determine the configuration that best satisfies the thrust, heat, and stability requirements for the engine. I have had to research the configurations that are being tested and gain an understanding of the purpose of the tests. I then had to research the parts that would be used in the test configurations. I was taken to see parts similar to the ones used in the test configurations and was allowed to review drawings and dimensions used for those parts. My job over this summer has been to use the knowledge I have gained to design, model, and create drawings for the un-fabricated parts that are necessary for the J-2X Workhorse Gas Generator Phase IIcTest.

Miller, Nicholas↗

Does Adjuvant Radiotherapy Suppress Liver Regeneration After Partial Hepatectomy?

Purpose: To analyze the influence of the adjuvant radiotherapy (RT) on the liver regeneration and liver function after partial hepatectomy (PH). Methods and Materials: Thirty-four patients who underwent PH for biliary tract cancer between October 2003 and July 2005 were reviewed. Hemihepatectomy was performed in 14 patients and less extensive surgery in 20. Of the patients, 19 patients had no adjuvant therapy (non-RT group) and 15 underwent adjuvant RT by a three-dimensional conformal technique (RT group). Radiation dose range was 40 to 50 Gy (median, 40 Gy). Liver volume on computed tomography and the results of liver function tests at 1, 4, 12, 24, and 52 weeks after PH were compared between the RT and non-RT groups. Results: The preoperative characteristics were identical for both groups. During the interval between Weeks 4 and 12 when adjuvant RT was delivered in the RT group, the increase in liver volume was significantly smaller in the RT group than non-RT group (22.9 {+-} 38.3cm{sup 3} and 81.5 {+-} 75.6cm{sup 3}, respectively, p = 0.007). However, the final liver volume measured at 1 year after PH did not differ between the two groups (p = 0.878). Liver function tests were comparable for both groups. The resection extent and original liver volume was independent factors for final liver volume measured at 1 year after PH. Conclusions: In this study, adjuvant RT delayed the liver regeneration process after PH, but the volume difference between the two study groups became nonsignificant after 1 year. Adjuvant RT had no additional adverse effect on liver function after PH.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

E6 proteins of α and β cutaneous HPV types differ in their ability to potentiate Wnt signaling

We recently showed that E6 protein of human papillomavirus (HPV) 16, a mucosal high-risk α-PV type, can potentiate Wnt/β-catenin/TCF signaling. Here we investigated the transcriptional activities of E6 proteins of cutaneous HPV types from the β and α genera. Results from reporter-gene assays showed that similar to HPV16 E6, E6 of HPV10, a cutaneous α-HPV type that is prevalent in skin warts, efficiently enhances and stimulates Wnt/β-catenin/TCF transcription. HPV10 E6 also effectively elevated the expression levels of β-catenin and promoted its nuclear accumulation. E6 proteins of β-HPV types 8, 24, 38 and 49, which are prevalent in skin cancer, exhibited lower activities in all tested functions. The differences in activity correlated with E6's competence to interact with the ubiquitin ligase E6AP. This study reveals a role for E6 proteins of diverse cutaneous HPV types in potentiation of Wnt/β-catenin signaling, irrespective of their carcinogenic potential. - Highlights: • β- and α-HPV E6 proteins were compared for their effect on β-catenin signaling. • Promotion of β-catenin transcription, stability and nuclear accumulation was tested. • E6 of HPV10, a wart associated α-HPV, showed the highest activity in all tested functions. • E6s of the cancer associated, β-HPVs (8, 24, 38, 49), exhibited lower activities. • The difference correlated with E6 ability to bind the ubiquitin ligase E6AP.

60 APPLIED LIFE SCIENCES↗

Development and Testing of Functionally Operative and Visually Appealing Remote Firing Room Displays and Applications

This internship provided an opportunity for an intern to work with NASA's Ground Support Equipment (GSE) for the Spaceport Command and Control System (SCCS) at Kennedy Space Center as a remote display developer, under NASA technical mentor Kurt Leucht. The main focus was on creating remote displays and applications for the hypergolic and high pressure helium subsystem team to help control the filling of the respective tanks. As a remote display and application developer for the GSE hypergolic and high pressure helium subsystem team the intern was responsible for creating and testing graphical remote displays and applications to be used in the Launch Control Center (LCC) on the Firing Room's computers. To become more familiar with the subsystem, the individual attended multiple project meetings and acquired their specific requirements regarding what needed to be included in the software. After receiving the requirements for the displays, the next step was to create displays that had both visual appeal and logical order using the Display Editor, on the Virtual Machine (VM). In doing so, all Compact Unique Identifiers (CUI), which are associated with specific components within the subsystem, were need to be included in each respective display for the system to run properly. Then, once the display was created it was to be tested to ensure that the display runs as intended by using the Test Driver, also found on the VM. This Test Driver is a specific application that checks to make sure all the CUIs in the display are running properly and returning the correct form of information. After creating and locally testing the display it needed to go through further testing and evaluation before deemed suitable for actual use. For the remote applications the intern was responsible for creating a project that focused on channelizing each component included in each display. The core of the application code was created by setting up spreadsheets and having an auto test generator, generate the complete code structure. This application code was then loaded and ran on a testing environment set to ensure the code runs as anticipated. By the end of the semester-long experience at NASA's Kennedy Space Center, the individual should have gained great knowledge and experience in various areas of both display and application development and testing. They were able to demonstrate this new knowledge obtained by creating multiple successful remote displays that will one day be used by the hypergolic and high pressure helium subsystem team in the LCC's firing rooms to service the new Orion spacecraft. The completed display channelization application will be used to receive verification from NASA quality engineers.

Display Devices↗

Benchmarking the performance of density functional theory and point charge force fields in their description of sI methane hydrate against diffusion Monte Carlo

High quality reference data from diffusion Monte Carlo calculations are presented for bulk sI methane hydrate, a complex crystal exhibiting both hydrogen-bond and dispersion dominated interactions. The performance of some commonly used exchange-correlation functionals and all-atom point charge force fields is evaluated. Our results show that none of the exchange-correlation functionals tested are sufficient to describe both the energetics and the structure of methane hydrate accurately, while the point charge force fields perform badly in their description of the cohesive energy but fair well for the dissociation energetics. By comparing to ice I{sub h}, we show that a good prediction of the volume and cohesive energies for the hydrate relies primarily on an accurate description of the hydrogen bonded water framework, but that to correctly predict stability of the hydrate with respect to dissociation to ice I{sub h} and methane gas, accuracy in the water-methane interaction is also required. Our results highlight the difficulty that density functional theory faces in describing both the hydrogen bonded water framework and the dispersion bound methane.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗