Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOCUSING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Signatures of vacuum birefringence in low-power flying focus pulses

Vacuum birefringence produces a differential phase between orthogonally polarized components of a weak electromagnetic probe in the presence of a strong electromagnetic field. Despite representing a hallmark prediction of quantum electrodynamics, vacuum birefringence remains untested in pure light configurations due to the extremely large electromagnetic fields required for a detectable phase difference. Here, we exploit the programmable focal velocity and extended focal range of a flying focus laser pulse to substantially lower the laser power required for detection of vacuum birefringence. In the proposed scheme, a linearly polarized x-ray probe pulse counterpropagates with respect to a flying focus pulse, whose focus moves at the speed of light in the same direction as the x-ray probe. The peak intensity of the flying focus pulse overlaps the probe over millimeter-scale distances and induces a polarization ellipticity on the order of 10 − 10 , which lies within the detection sensitivity of existing x-ray polarimeters. Published by the American Physical Society 2024

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Ultrabright Electron Bunch Injection in a Plasma Wakefield Driven by a Superluminal Flying Focus Electron Beam

Here, we propose a new method for self-injection of high-quality electron bunches in the plasma wakefield structure in the blowout regime utilizing a “flying focus” produced by a drive beam with an energy chirp. In a flying focus the speed of the density centroid of the drive bunch can be superluminal or subluminal by utilizing the chromatic dependence of the focusing optics. We first derive the focal velocity and the characteristic length of the focal spot in terms of the focal length and an energy chirp. We then demonstrate using multidimensional particle-in-cell simulations that a wake driven by a superluminally propagating flying focus of an electron beam can generate GeV-level electron bunches with ultralow normalized slice emittance (~30 nm rad), high current (~17 kA), low slice energy spread (~0.1%), and therefore high normalized brightness (> 10 19 A/ m 2 /rad 2 ) in a plasma of density ~10 19 cm –3 . The injection process is highly controllable and tunable by changing the focal velocity and shaping the drive beam current. Nearterm experiments at FACET II where the capabilities to generate tens of kA, < 10 fs drivers are planned, could potentially produce beams with brightness near 10 20 A / m 2 / rad 2 .

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Self-Focused Pulse Propagation Is Mediated by Spatiotemporal Optical Vortices

We show that the dynamics of high-intensity laser pulses undergoing self-focused propagation in a nonlinear medium can be understood in terms of the topological constraints imposed by the formation and evolution of spatiotemporal optical vortices (STOVs). STOVs are born from point phase defects on the sides of the pulse nucleated by spatiotemporal phase shear. These defects grow into closed loops of spatiotemporal vorticity that initially exclude the pulse propagation axis, but then reconnect to form a pair of toroidal vortex rings that wrap around it. STOVs constrain the intrapulse flow of electromagnetic energy, controlling the focusing-defocusing cycles and pulse splitting inherent to nonlinear pulse propagation. Here, we illustrate this in two widely studied but very different regimes, relativistic self-focusing in plasma and nonrelativistic self-focusing in gas, demonstrating that STOVs mediate nonlinear propagation irrespective of the detailed physics.

42 ENGINEERING↗

Focusing a round coherent beam by spatial filtering the horizontal source

This paper illustrates the use of spatial filtering with a horizontal slit near the source to enlarge the horizontal coherence in an experimental station and produce a diffraction-limited round focus at an insertion device beamline for X-ray photon correlation spectroscopy experiments. Simple expressions are provided to guide the optical layout, and wave propagation simulations confirm their applicability. The two-dimensional focusing performance of Be compound refractive lenses to produce a round diffraction-limited focus at 11 keV capable of generating a high-contrast speckle pattern of an aerogel sample is demonstrated. The coherent scattering patterns have comparable speckle sizes in both horizontal and vertical directions. The focal spot sizes are consistent with hybrid ray-tracing calculations. Producing a two-dimensional focus on the sample can be helpful to resolve speckle patterns with modern pixel array detectors with high visibility. This scheme has now been in use since 2019 for the 8-ID beamline at the Advanced Photon Source, sharing the undulator beam with two separate beamlines, 8-ID-E and 8-ID-I at 7.35 keV, with increased partially coherent flux, reduced horizontal spot sizes on samples, and good speckle contrast.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

MO-AB-210-00: Diagnostic Ultrasound Imaging Quality Control and High Intensity Focused Ultrasound Therapy Hands-On Workshop

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

MO-AB-210-03: Workshop [ Advancements in high intensity focused ultrasound ]

The goal of this ultrasound hands-on workshop is to demonstrate advancements in high intensity focused ultrasound (HIFU) and to demonstrate quality control (QC) testing in diagnostic ultrasound. HIFU is a therapeutic modality that uses ultrasound waves as carriers of energy. HIFU is used to focus a beam of ultrasound energy into a small volume at specific target locations within the body. The focused beam causes localized high temperatures and produces a well-defined regions of necrosis. This completely non-invasive technology has great potential for tumor ablation and targeted drug delivery. At the workshop, attendees will see configurations, applications, and hands-on demonstrations with on-site instructors at separate stations. The involvement of medical physicists in diagnostic ultrasound imaging service is increasing due to QC and accreditation requirements. At the workshop, an array of ultrasound testing phantoms and ultrasound scanners will be provided for attendees to learn diagnostic ultrasound QC in a hands-on environment with live demonstrations of the techniques. Target audience: Medical physicists and other medical professionals in diagnostic imaging and radiation oncology with interest in high-intensity focused ultrasound and in diagnostic ultrasound QC. Learning Objectives: Learn ultrasound physics and safety for HIFU applications through live demonstrations Get an overview of the state-of-the art in HIFU technologies and equipment Gain familiarity with common elements of a quality control program for diagnostic ultrasound imaging Identify QC tools available for testing diagnostic ultrasound systems and learn how to use these tools List of supporting vendors for HIFU and diagnostic ultrasound QC hands-on workshop: Philips Healthcare Alpinion Medical Systems Verasonics, Inc Zonare Medical Systems, Inc Computerized Imaging Reference Systems (CIRS), Inc. GAMMEX, Inc., Cablon Medical BV Steffen Sammet: NIH/NCI grant 5R25CA132822, NIH/NINDS grant 5R25NS080949 and Philips Healthcare research grant C32.

60 APPLIED LIFE SCIENCES↗

TU-B-210-00: MR-Guided Focused Ultrasound Therapy in Oncology

MR guided focused ultrasound (MRgFUS), or alternatively high-intensity focused ultrasound (MRgHIFU), is approved for thermal ablative treatment of uterine fibroids and pain palliation in bone metastases. Ablation of malignant tumors is under active investigation in sites such as breast, prostate, brain, liver, kidney, pancreas, and soft tissue. Hyperthermia therapy with MRgFUS is also feasible, and may be used in conjunction with radiotherapy and for local targeted drug delivery. MRI allows in situ target definition and provides continuous temperature monitoring and subsequent thermal dose mapping during HIFU. Although MRgHIFU can be very precise, treatment of mobile organs is challenging and advanced techniques are required because of artifacts in MR temperature mapping, the need for intercostal firing, and need for gated HIFU or tracking of the lesion in real time. The first invited talk, “MR guided Focused Ultrasound Treatment of Tumors in Bone and Soft Tissue”, will summarize the treatment protocol and review results from treatment of bone tumors. In addition, efforts to extend this technology to treat both benign and malignant soft tissue tumors of the extremities will be presented. The second invited talk, “MRI guided High Intensity Focused Ultrasound – Advanced Approaches for Ablation and Hyperthermia”, will provide an overview of techniques that are in or near clinical trials for thermal ablation and hyperthermia, with an emphasis of applications in abdominal organs and breast, including methods for MRTI and tracking targets in moving organs. Learning Objectives: Learn background on devices and techniques for MR guided HIFU for cancer therapy Understand issues and current status of clinical MRg HIFU Understand strategies for compensating for organ movement during MRgHIFU Understand strategies for strategies for delivering hyperthermia with MRgHIFU CM - research collaboration with Philips.

60 APPLIED LIFE SCIENCES↗

Design of ultrasonic attenuation sensor with focused transmitter for density measurements of a slurry in a large steel pipeline

To design an ultrasonic sensor to measure the attenuation and density of a slurry carried by a large steel pipeline (diameter up to 70 cm) is the goal of this research. The pitch-catch attenuation sensor, placed in a small section of the pipeline, contains a send unit with a focused transducer that focuses the ultrasound to a small region of the receive unit on the opposite wall. The focused transducer consists of a section of a sphere (base ~12 cm) on the outer side of the send unit and a 500 kHz piezoelectric shell of PZT5A epoxied to it. The Rayleigh surface integral is used to calculate the pressure in steel and in water (slurry). An incremental method to plot the paths of ultrasonic rays shows that the rays focus where expected. Further, there is a region where the parallel rays are perpendicular to the wall of the receive unit. Designs for pipeline diameters of 25 cm and 71 cm show that the pressure in water at the receive transducer is about 17 times that for a pitch-catch system using 5 cm diameter disk transducers. The enhanced signal increases the sensitivity of the measurements and improves the signal-to-noise ratio.

Greenwood, Margaret Stautberg↗

Investigation of focusing and correcting aberrations with binary amplitude and polarization modulation

Here, we investigate the focusing and correcting wavefront aberration of an optical wave using binary amplitude and polarization modulation. Focusing is performed by selectively modulating the field in different zones of the pupil to obtain on-axis constructive interference at a given distance. The conventional Soret zone plate (binary amplitude profile) is expanded to a polarization Soret zone plate with twice the focusing efficiency. Binary pixelated devices that approximate the sinusoidal transmission profile of a Gabor zone plate by spatial dithering are also investigated with amplitude and polarization modulation. Wavefront aberrations are corrected by modulation of the field in the pupil plane to prevent destructive interference in the focal plane of an ideal focusing element. Polarization modulation improves the efficiency obtained by amplitude-only modulation, with a gain that depends on the aberration. Experimental results obtained with Cr-on-glass devices for amplitude modulation and liquid crystal devices operating in the Mauguin condition for polarization modulation are in very good agreement with simulations.

47 OTHER INSTRUMENTATION↗

Beam distortion effects upon focusing an ultrashort petawatt laser pulse to greater than 10 22 W/cm 2

When an ultrashort laser pulse is tightly focused to a size approaching its central wavelength, the properties of the focused spot diverge from the diffraction-limited case. Here, we report on this change in behavior of a tightly focused petawatt-class laser beam by an $f/1$ off-axis parabolic mirror (OAPM). Considering the effects of residual aberration, the spatial profile of the near-field, and pointing error, we estimate the deviation in peak intensities of the focused spot from the ideal case. Here, we verify that the estimated peak intensity values are within an acceptable error range of the measured values. With the added uncertainties in target alignment, we extend the estimation to infer on-target peak intensities of ≥10 22 W/cm 2 for a target at the focal plane of this $f/1$ OAPM.

47 OTHER INSTRUMENTATION↗

Thrust #3: Simulation and Measurement of Bio-enabled Lensless Infrared Focusing and Spatially-Controlled Multiwavelength IR reflection

The path to quantitatively characterizing the possible impact of refractive index on the focusing behavior of C. Wailesii diatoms frustules and their replicas first required the careful design of a control experiment that allowed for judicious control of both material and hole pattern variables, which are thought to govern focusing behavior. This was accomplished by FIB-milling synthetic hole patterns with well-controlled dimensions into thin SiO 2 and MgO/Si films. In doing so, an ideal sample is obtained whose pore patterns can be simulated via beam propagation methods and whose relatively simple interference patterns can be measured by far-field diffraction imaging. Together with refractive index measurements via ellipsometry on SiO 2 and MgO/Si thin films, these results showed that the focusing distances at six different wavelengths over 550-1050 nm are strongly correlated with the dispersion of the refractive index in this range. Although assertions have been made to this point in the literature, the results given here presented an improved characterization of the role that refractive index played in focusing behavior in a “diatom-like” hole pattern that otherwise is missing in earlier works due to inadequate characterization of refractive index dispersion and poor control over hole pattern dimensions. These results provided a reference point with which measurements and simulations of diatoms and their replicas can be compared.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Physical Sciences Vistas: Perspectives on Excellence in Mission-Focused Science, Technology, and Engineering at Los Alamos Laboratory (Issue 1, 2020)

This is the first 2020 issue of Physical Sciences Vistas, with a focus on “excellence in mission-focused science, technology, and engineering.” Excellence in mission-focused ST&E comprises one of the four elements of the Laboratory Agenda, focusing on sustaining and enhancing LANL’s science base. This issue highlights the diverse efforts of personnel in our Physical Sciences Directorate (ALDPS) to enhance science, technology, and engineering at the Laboratory. As we reflect on work at the Laboratory, mostly from our homes due to COVID-19, it is gratifying to see the important, diverse contributions to ST&E across ALDPS.

36 MATERIALS SCIENCE↗

Fast Ultrasonic Imaging with Total Focusing Method (TFM) for Inspection of Additively Manufactured Polymer Composite Component

Ultrasonic adaptive imaging based on the phased-array technology and the synthetic focusing algorithm Total Focusing Method (TFM) is proposed for fast ultrasonic nondestructive evaluation of additively manufactured composite materials. Nondestructive evaluation and inspection of additively manufactured parts and components are necessary for quality assurance of the materials. Effective detection of defects and anomalies in manufactured parts prevents extra cost and production time. However, there are several limitations encountered when using conventional methods of nondestructive inspection for as built additively manufactured parts due to surface conditions and geometrical complexity. Post-processing operations, such as machining, are usually needed to detect possible defects such as layer disband, micro-cracks, and voids in the composite parts. The capability of aperture focusing in phased array ultrasonic methods provides the opportunity for the adjustment of the delay laws in ultrasonic beams and reduces the noise and beam distortion for better imaging. An additively manufactured carbon fiber reinforced Acrylonitrile Butadiene Styrene (ABS) composite sample with artificial side and bottom-drilled holes of different sizes, used to represent defects, was successfully inspected using the Total Focusing Method (TFM). Unlike conventional ultrasonic techniques, results show a promising way to provide inspection of as built additively manufactured composite parts with rough surface finishes. The proposed method helps to decrease inspection time and eliminate extra machining and preparation costs.

Taheri, Hossein↗

A study of transient stimulated Raman scattering and self-focusing in the picosecond time regime

Two third order processes, stimulated Raman scattering and self-focusing, with picosecond pulses are studied. In the case of transient stimulated scattering, the gain is reduced from the steady state value, and qualitatively new features, such as shortening and delay of the Stokes pulse relative to the laser pulse, appear. These predictions are extended to realistic laser pulses, and experiments confirm all of the theoretical predictions. The self-focusing and frequency broadening of picosecond pulses is studied in the absence of stimulated Raman scattering in several materials with large orientational Kerr constants. Measurements of the relaxation time indicate that the orientational Kerr effect is important in the self-focusing of picosecond pulses. Self-focused filaments are observed to propagate with constant diameters over a distance greater than 10 cm, but disappear before the end of a 20 cm cell. The filaments radiate light continuously along their path and the spectrum of the light shows that the frequency content extends symmetrically for several hundred wave numbers on either side of the laser frequency.

Reintjes, J. F.↗

Prediction of sonic boom at a focus

The behavior of sonic boom at a focus has been reviewed for the purpose of extending present sonic boom computational methods to include focal zones. The geometry of a focal zone - whether a smooth caustic, a cusped caustic, or a perfect focus to a point - determines the character of focused signatures. The seeming contradiction of various experimental data can be resolved by noting these differences. A ray acoustic analysis has been developed for quantitative determination of caustic geometry. The only reliable theory presently available for signatures at a focus is for a smooth caustic. There has been some controversy between theoretical and experimental values of a constant in the scaling law for this case. It has been found that this discrepancy can be resolved by accounting for the finite thickness of real sonic boom shock waves. These findings have been incorporated into an existing sonic boom computer program.

Plotkin, K. J.↗

The effect of adiabatic focusing upon charged-particle propagation in random magnetic fields

The charged particles considered are scattered by random fields while they propagate along the diverging lines of force of a spatially inhomogeneous guiding field. Their longitudinal transport is described in terms of the eigenfunctions of a Sturm-Liouville operator which incorporates the effect of adiabatic focusing along with that of scattering. The relaxation times and characteristic velocities which appear in this matrix formulation of the transport problem are graphed and tabulated. Explicit formulas which describe the particle-density profile that results from a localized impulsive injection are derived for two different regimes. In the first regime, where focusing is relatively weak, a diffusive mode of propagation is dominant, but coherent modes are also present, and they become prominent as the intensity of focusing increases. In the second regime, where focusing is strong and where diffusion does not occur, the propagation is purely coherent. The existence of this supercoherent mode of particle transport opens up many possibilities for the interpretation of astrophysical phenomena.

Earl, J. A.↗

Scanning and focusing mechanisms of METEOSAT radiometer

The scanning and focusing mechanisms settled onboard the METEOSAT Radiometer are described. A large camera which will take line by line pictures of the earth from a geostationary satellite in the same manner as a TV picture using both the spin of the spacecraft and the tilt of a telescope is included. The scanning mechanism provides the + or - 9 degrees tilt angle of the telescope through 2,500 elementary steps of 1.256 0.0001 radian. As the radiometer image quality is closely dependent on the characteristics of the scanning law, the mechanism is required to fulfill functional performances specifications particularly severe in terms of linearity of the scan curve, accuracy of each step as well as repeatability of the short-term scanning. The focusing mechanism allows + or - 12 millimeters shift of the telescope focus by step increments of 0.140 mm. The focus adjustment is achieved by moving a dihedral reflector according to a pure straight-line motion. The main requirements of each mechanism are summarized and their design and performances are described in detail.

Jouan, J.↗

Investigation of a staged plasma-focus apparatus

A new staged plasma-focus geometry combining two Mather-type plasma-focus guns was constructed, and the current-sheet dynamics were investigated. The production of simultaneous pairs of plasma foci was achieved. The intensities of X-ray and fusion-neutron emission were measured and found to agree with the scaling law for a plasma focus. Advantages of this new geometry include the possibility of using plasma-focus type pinches in multiple arrays at power levels beyond the validity regime of the current scaling law for a single gun.

Lee, J. H.↗