Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLUOROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Preclinical investigation for developing injectable fiducial markers using a mixture of BaSO{sub 4} and biodegradable polymer for proton therapy

Purpose: The aim of this study is to investigate the use of mixture of BaSO{sub 4} and biodegradable polymer as an injectable nonmetallic fiducial marker to reduce artifacts in x-ray images, decrease the absorbed dose distortion in proton therapy, and replace permanent metal markers. Methods: Two samples were made with 90 wt. % polymer phosphate buffer saline (PBS) and 10 wt. % BaSO{sub 4} (B1) or 20 wt. % BaSO{sub 4} (B2). Two animal models (mice and rats) were used. To test the injectability and in vivo gelation, a volume of 200 μl at a pH 5.8 were injected into the Sprague-Dawley rats. After sacrificing the rats over time, the authors checked the gel morphology. Detectability of the markers in the x-ray images was tested for two sizes (diameters of 1 and 2 mm) for B1 and B2. Four samples were injected into BALB/C mice. The polymer mixed with BaSO{sub 4} transform from SOL at 20 °C with a pH of 6.0 to GEL in the living body at 37 °C with a pH of 7.4, so the size of the fiducial marker could be controlled by adjusting the injected volume. The detectability of the BaSO{sub 4} marker was measured in x-ray images of cone beam CT (CBCT), on-board imager [anterior–posterior (AP), lateral], and fluoroscopy (AP, lateral) using a Novalis-TX (Varian Medical Systems, Palo Alto, CA) repeatedly over 4 months. The volume, HU, and artifacts for the markers were measured in the CBCT images. Artifacts were compared to those of gold marker by analyzing the HU distribution. The dose distortion in proton therapy was computed by using a Monte Carlo (MC) code. A cylindrical shaped marker (diameter: 1 or 2 mm, length: 3 mm) made of gold, stainless-steel [304], titanium, and 20 wt. % BaSO{sub 4} was positioned at the center of the spread-out Bragg peak (SOBP) in parallel or perpendicular to the beam entrance. The dose distortion was measured on the depth dose profile across the markers. Results: Transformation to GEL and the biodegradation were verified. All BaSO{sub 4} markers could be detected in the CBCT. In the OBI and fluoroscopy images, all markers visible in the AP, but only B2(2 mm) could be identified in the lateral images. Changes of BaSO{sub 4} position were not detected in vivo (mice). The volume of the markers decreased by up to 65% and the HU increased by 22%, on average. The mean HU values around the B1, B2, and gold markers were 121.30 [standard deviation (SD): 54.86], 126.31 (SD: 62.13), and 1070.7 (SD: 235.16), respectively. The MC-simulated dose distortion for the BaSO{sub 4} markers was less than that of the commercially used markers. The dose reduction due to the gold marker was largest (15.05%) followed by stainless steel (7.92%) and titanium (6.92%). Dose reduction by B2 (2 mm) was 4.75% and 0.53% in parallel and perpendicular orientations, respectively. Conclusions: BaSO{sub 4} mixed with PBS is a good contrast agent in biodegradable polymer marker because of minimal artifacts in x-ray images and minimal dose reduction in proton therapy. The flexibility of the size is considered to be an advantage of this material over solid type fiducials.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-06: ECG-Gated CT Reconstruction for a C-Arm Inverse Geometry X-Ray System

Purpose: To obtain ECG-gated CT images from truncated projection data acquired with a C-arm based inverse geometry fluoroscopy system, for the purpose of cardiac chamber mapping in interventional procedures. Methods: Scanning-beam digital x-ray (SBDX) is an inverse geometry fluoroscopy system with a scanned multisource x-ray tube and a photon-counting detector mounted to a C-arm. In the proposed method, SBDX short-scan rotational acquisition is performed followed by inverse geometry CT (IGCT) reconstruction and segmentation of contrast-enhanced objects. The prior image constrained compressed sensing (PICCS) framework was adapted for IGCT reconstruction to mitigate artifacts arising from data truncation and angular undersampling due to cardiac gating. The performance of the reconstruction algorithm was evaluated in numerical simulations of truncated and non-truncated thorax phantoms containing a dynamic ellipsoid to represent a moving cardiac chamber. The eccentricity of the ellipsoid was varied at frequencies from 1–1.5 Hz. Projection data were retrospectively sorted into 13 cardiac phases. Each phase was reconstructed using IGCT-PICCS, with a nongated gridded FBP (gFBP) prior image. Surface accuracy was determined using Dice similarity coefficient and a histogram of the point distances between the segmented surface and ground truth surface. Results: The gated IGCT-PICCS algorithm improved surface accuracy and reduced streaking and truncation artifacts when compared to nongated gFBP. For the non-truncated thorax with 1.25 Hz motion, 99% of segmented surface points were within 0.3 mm of the 15 mm diameter ground truth ellipse, versus 1.0 mm for gFBP. For the truncated thorax phantom with a 40 mm diameter ellipse, IGCT-PICCS surface accuracy measured 0.3 mm versus 7.8 mm for gFBP. Dice similarity coefficient was 0.99–1.00 (IGCT-PICCS) versus 0.63–0.75 (gFBP) for intensity-based segmentation thresholds ranging from 25–75% maximum contrast. Conclusions: The PICCS algorithm was successfully applied to reconstruct truncated IGCT projection data with angular undersampling resulting from simulated cardiac gating. Research supported by the National Heart, Lung, and Blood Institute of the NIH under award number R01HL084022. The content is solely the responsibility of the authors and does not necessarily represent the official views of the NIH.

60 APPLIED LIFE SCIENCES↗

RECONSTRUCTION OF INDIVIDUAL DOSES DUE TO MEDICAL EXPOSURES FOR MEMBERS OF THE TECHA RIVER COHORT

Purpose: To describe a methodology for reconstruction of doses due to medical exposures for members of the Techa River Cohort (TRC) who received diagnostic radiation at the clinic of the Urals Research Center for Radiation Medicine (URCRM) in 1952–2005. To calculate doses of medical exposure for the TRC members and compare with the doses that resulted from radioactive contamination of the Techa River. Material and Methods: Reconstruction of individual medical doses is based on data on x-ray diagnostic procedures available for each person examined at the URCRM clinics and values of absorbed dose in 12 organs per typical x-ray procedure calculated with the use of a mathematical phantom. Personal data on x-ray diagnostic examinations have been complied in the computerized “Registry of x-ray diagnostic procedures.” Sources of information are archival registry books from the URCRM x-ray room (available since 1956) and records on x-ray diagnostic procedures in patient-case histories (since 1952). The absorbed doses for 12 organs of interest have been evaluated per unit typical x-ray procedure with account taken of the x-ray examination parameters characteristic for the diagnostic machines used at the URCRM clinics. These parameters have been evaluated from published data on technical characteristics of the x-ray diagnostic machines used at the URCRM clinics in 1952–1988 and taken from the x-ray room for machines used at the URCRM in 1989–2005. Absorbed doses in the 12 organs per unit typical x-ray procedure have been calculated with use of a special computer code, EDEREX, developed at the Saint-Petersburg Research Institute of Radiation Hygiene after Professor P.V. Ramzaev. Individual accumulated doses of medical exposure have been calculated with a computer code, MEDS (Medical Exposure Dosimetry System), specifically developed at the URCRM. Results: At present, the “Registry of x-ray diagnostic procedures” contains information on individual x-ray examinations for over 9,500 persons including 6,415 TRC members. Statistical analysis of the Registry data showed that the more frequent types of examinations were fluoroscopy and radiography of the chest and fluoroscopy of the stomach and the esophagus. Average absorbed doses accumulated by year 2005 calculated for the 12 organs varied from 4 mGy for testes to 40 mGy for bone surfaces. Maximum individual medical doses could reach 500–650 mGy and in some cases exceeded doses from exposure at the Techa River. Conclusions: For the first time the doses of medical exposure were calculated and analyzed for members of the Techa River Cohort who received diagnostic radiation at the URCRM clinics. These results are being used in radiation-risk analysis to adjust for this source of confounding exposure in the TRC.

dose reconstruction↗

Radiation dose in coronary angiography and intervention: initial results from the establishment of a multi-centre diagnostic reference level in Queensland public hospitals

Radiation dose to patients undergoing invasive coronary angiography (ICA) is relatively high. Guidelines suggest that a local benchmark or diagnostic reference level (DRL) be established for these procedures. This study sought to create a DRL for ICA procedures in Queensland public hospitals. Data were collected for all Cardiac Catheter Laboratories in Queensland public hospitals. Data were collected for diagnostic coronary angiography (CA) and single-vessel percutaneous intervention (PCI) procedures. Dose area product (P{sub KA}), skin surface entrance dose (K{sub AR}), fluoroscopy time (FT), and patient height and weight were collected for 3 months. The DRL was set from the 75th percentile of the P{sub KA.} 2590 patients were included in the CA group where the median FT was 3.5 min (inter-quartile range = 2.3–6.1). Median K{sub AR} = 581 mGy (374–876). Median P{sub KA} = 3908 uGym{sup 2} (2489–5865) DRL = 5865 uGym{sup 2}. 947 patients were included in the PCI group where median FT was 11.2 min (7.7–17.4). Median K{sub AR} = 1501 mGy (928–2224). Median P{sub KA} = 8736 uGym{sup 2} (5449–12,900) DRL = 12,900 uGym{sup 2}. This study established a benchmark for radiation dose for diagnostic and interventional coronary angiography in Queensland public facilities.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Superior mesenteric artery syndrome: a radiographic review

Purpose: To provide a review of the etiology, clinical presentation, and imaging findings of superior mesenteric artery (SMA) syndrome. Methods: A literature review of 24 relevant articles regarding SMA syndrome was performed. Results: Clinicians and radiologists with a high index of suspicion based on symptomatology may pursue radiologic investigation in the form of upper gastrointestinal (GI) series and contrast-enhanced abdominal computed tomography (CT). Magnetic resonance imaging (MRI) and ultrasound (US) are less commonly utilized modalities in the work-up of SMA syndrome, but provide imaging alternatives without the use of ionizing radiation. Imaging can assist in diagnosis by demonstrating characteristic findings of reduced aortomesenteric angle, reduced aortomesenteric distance, gastroduodenal distention, bowel caliber narrowing at the takeoff of the superior mesenteric artery from the aorta, as well as delayed gastric emptying or positional obstruction observed with real time with fluoroscopy. Conclusion: SMA syndrome is a rare disease that can go unrecognized and undiagnosed, exacerbating weight loss in an already significantly malnourished patient population. The diagnosis of SMA syndrome must be based on clinical symptomatology correlated with radiographic information. Once diagnosed, SMA syndrome can be safely treated by conservative measures although occasionally requires invasive intervention in the form of enteral tube placement, percutaneous jejunostomy tube placement, total parenteral nutrition, ligament of Treitz lysis, or duodenojejunostomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Palliation of Malignant Biliary and Duodenal Obstruction with Combined Metallic Stenting

Purpose. The purpose of this study is to evaluate the efficacy of palliation of malignant biliary and duodenal obstruction with combined metallic stenting under fluoroscopy guidance. Materials and Methods. A retrospective analysis of 9 patients (6 men and 3 women) who underwent biliary and duodenal stenting was performed. The mean age of patients was 61 years (range: 42-80 years). The causes of obstruction were pancreatic carcinoma in 7 patients, cholangiocellular carcinoma in one, and duodenal carcinoma in the other. Biliary and duodenal stents were placed simultaneously in 4 patients. In other 5 patients dudodenal stents were placed after biliary stenting when the duodenal obstruction symptoms have developed. In two patients duodenal stents were advanced via transgastric approach. Results. Technical success rate was 100 %. After percutaneous biliary drainage and stenting bilirubin levels decreased to normal levels in 6 patients and in remaining 3 patients mean reduction of 71% in bilirubin levels was achieved. Tumoral ingrowth occurred in one patient and percutaneous biliary restenting was performed 90 days after the initial procedure. Of the 9 patients, 6 patients were able to tolerate solid diet, whereas 2 patients could tolerate liquid diet and one patient did not show any improvement. Mean survival periods were 111 and 73 days after biliary and duodenal stenting, respectively. Conclusion. Combined biliary and duodenal stent placement which can be performed under fluoroscopic guidance without assistance of endoscopy is feasible and an effective method of palliation of malignant biliary and duodenal obstructions. If transoral and endoscopic approaches fail, percutaneous gastrostomy route allows duodenal stenting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Staff Radiation Doses to the Lower Extremities in Interventional Radiology

The purpose of this study was to investigate the radiation doses to the lower extremities in interventional radiology suites and evaluate the benefit of installation of protective lead shielding. After an alarmingly increased dose to the lower extremity in a preliminary study, nine interventional radiologists wore thermoluminescent dosimeters (TLDs) just above the ankle, over a 4-week period. Two different interventional suites were used with Siemens undercouch fluoroscopy systems. A range of procedures was carried out including angiography, embolization, venous access, drainages, and biopsies. A second identical 4-week study was then performed after the installation of a 0.25-mm lead curtain on the working side of each interventional table. Equivalent doses for all nine radiologists were calculated. One radiologist exceeded the monthly dose limit for a Category B worker (12.5 mSv) for both lower extremities before lead shield placement but not afterward. The averages of both lower extremities showed a statistically significant dose reduction of 64% (p < 0.004) after shield placement. The left lower extremity received a higher dose than the right, 6.49 vs. 4.57 mSv, an increase by a factor of 1.42. Interventional radiology is here to stay but the benefits of interventional radiology should never distract us from the important issue of radiation protection. All possible measures should be taken to optimize working conditions for staff. This study showed a significant lower limb extremity dose reduction with the use of a protective lead curtain. This curtain should be used routinely on all C-arm interventional radiologic equipment.

61 RADIATION PROTECTION AND DOSIMETRY↗

Retrospective Study of Rapid-Exchange Monorail Versus Over-the-Wire Technique for Femoropopliteal Angioplasty

PurposeThe purpose of this study was to compare procedural outcome of rapid-exchange (RX) monorail versus conventional over-the-wire (OTW) technique for femoropopliteal angioplasty.Materials and MethodsDemographic data, procedure details, angioplasty success, and complications of 328 consecutive percutaneous transluminal angioplasties (PTAs) were collected from a prospective database and retrospectively analyzed. Procedure details included duration of fluoroscopy, area-dose product, amount of contrast agent, sheath sizes, access route, length of stenosis, presence of total occlusion, technical and anatomical success (residual stenosis <30% in the absence of complications), need for bail-out stenting, and periprocedural complications. The RX technique alone was used in 102 of 328 cases (31%); the OTW technique, in 226 of 328 of cases (68%).ResultsTechnical success was 98% for the RX versus 95.4% for the OTW technique (p = 0.2). A significantly greater number of stents had to be implanted due to angioplasty failure when the OTW technique was used (RX, 5.9%; OTW, 13.7%; p = 0.04). There were no significant differences in fluorocopy time, dose-area product, or amount of contrast medium used. The RX system facilitated the use of smaller sheath sizes (5 Fr = 38% and 6 Fr = 59% for RX versus 5 Fr = 16.8% and {>=}6 Fr = 82.5% for OTW) but showed only a tendency toward lower overall complication rates (16.6% [17/102] in the RX group versus 19.9% [45/226] in the OTW group; p = 0.09). There was no effect on length of hospitalization. RX monorail systems were not associated with higher procedural costs when compared to conventional OTW technique.ConclusionWe conclude that RX monorail systems seem to enhance the technical success of femoropopliteal angioplasty. Although smaller sheath sizes can be used due to the lower profile of the RX systems, there is only a tendency toward lower complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gadolinium Use in Spine Pain Management Procedures for Patients with Contrast Allergies: Results in 527 Procedures

Introduction. To review the safety and efficacy of gadolinium in spine pain management procedures in patients at high risk for a contrast reaction and who are not suitable candidates for the use of standard non-ionic contrast. Methods. We reviewed records over a 61-month period of all image-guided spinal pain management procedures where patients had allergies making them unsuitable candidates for standard non-ionic contrast and where gadolinium was used to confirm needle tip placement prior to injection of medication. Results. Three hundred and four outpatients underwent 527 procedures. A spinal needle was used in all but 41 procedures. Gadolinium was visualized using portable C-arm fluoroscopy in vivo allowing for confirmation of needle tip location. The gadolinium dose ranged from 0.2 to 10 ml per level. The highest dose received by one patient was 15.83 ml intradiscally during a three-level discogram. Three hundred and one patients were discharged without complication or known delayed complications. One patient had documented intrathecal injection but without sequelae and 2 patients who underwent cervical procedures experienced seizures requiring admission to the intensive care unit. Both the latter patients were discharged without any further complications. Conclusion. Based on our experience we recommend using gadolinium judiciously for needle tip confirmation. We feel more confident using gadolinium in the lumbar spine and in cervical nerve blocks. Gadolinium should probably not be used as an injectate volume expander. The indications for gadolinium use in cervical needle-guided spine procedures are less clear and use of a blunt-tipped needle should be considered.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Lung Radiofrequency Ablation: In Vivo Experimental Study with Low-Perfusion-Rate Multitined Electrodes

The purpose of this study was to investigate the feasibility and safety of lung radiofrequency (RF) ablation by using low-perfusion-rate, expandable, multitined electrodes in an in vivo animal model. Ten New Zealand White rabbits underwent RF ablation using low-perfusion-rate, expandable, multitined electrodes (Starburst Talon; RITA Medical Systems, Mountain View, CA) and a 200-W RF generator. The electrode was positioned under fluoroscopy guidance and a single percutaneous RF ablation was performed. Saline perfusate was doped with nonionic iodinated contrast agent to render it visible on computed tomography (CT). The pump infused the saline doped with contrast agent into the lateral tines at a rate of 0.1ml/min. The planned ablation was of 3 min, with the hooks deployed to 2 cm at a target temperature of 105{sup o}C. An immediate posttreatment CT scan documented the distribution of the doped saline and the presence of immediate complications. The animals were monitored for delayed complications and sacrificed within 72 h (n = 4), 2 weeks (n = 3), or 4 weeks (n = 3). Assessment of ablation zone and adjacent structures was done at autopsy. Major complications consisted of pneumothorax requiring drainage (n = 2) and skin burn (n = 1). Immediately after the procedure the area of ablation was depicted at CT as a round, well-demarcated area, homogeneously opacified by iodinated contrast medium (mean size, 2.3 {+-} 0.8 cm). The presence of a sharply demarcated area of coagulation necrosis (mean size, 2.1 {+-} 0.4 cm) without severe damage to adjacent structures was confirmed at autopsy. In one case, euthanized at 4 weeks, in whom pneumothorax and pleural effusion were depicted, pleural fibrinous adhesions were demonstrated at autopsy. In conclusion, lung RF ablation performed in an in vivo animal model using low-perfusion-rate, expandable, multitined electrodes is feasible and safe. No severe damage to adjacent structures was demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Imaging of the Coronary Venous System: Validation of Three-Dimensional Rotational Venous Angiography Against Dual-Source Computed Tomography

Information on the anatomy of the cardiac venous system (CVS) is increasingly important for cardiac resynchronization therapy or percutaneous transvenous mitral valve annuloplasty. Three-dimensional (3D) imaging can further improve the understanding of the relationship of cardiac structures. This study was performed to validate the accuracy of rotational coronary sinus angiography (CSA) displaying the 3D anatomy of the CVS compared to ECG-gated, contrast-enhanced, cardiac dual-source computed tomography (DSCT). Five domestic pigs (60 kg) underwent DSCT using a standardized examination protocol. Using a standard C-arm for fluoroscopy, a rotational CSA was obtained and 3D-image reconstructions performed. Side branches were identified using both methods and enumerated. Vessel visibility was estimated for each side branch and great cardiac vein/anterior interventricular vein. Also, vessel diameters were measured at distinct landmarks, i.e., side branching. The amount of contrast medium was determined and the effective radiation exposure of both methods was calculated. There was no significant difference regarding the vessel diameter of the great cardiac vein/anterior interventricular vein or its side branches. Also, estimation of vessel visibility was not different between the two imaging modalities. Estimated radiation exposure and amount of contrast medium were lower for rotational CSA. In conclusion, a 3D reconstruction of rotational CSA images is possible. All parts of the CVS are well depicted, allowing a 3D overview of the CVS anatomy. On-site 3D visualization might improve decision making during cardiac interventions. In contrast to DSCT, rotational CSA does not demonstrate the anatomy of the mitral annulus or the course of the left circumflex artery.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Patient Dose Reference Levels for Interventional Radiology: A National Approach

A set of patient dose reference levels (RLs) for fluoroscopically guided interventional procedures was obtained in a survey launched by the National Society of Interventional Radiology (IR), involving 10 public hospitals, as recommended by the European Medical Exposures Directive. A sample of 1391 dose values (kerma area product [KAP]) was collected randomly during clinical procedures for seven of the most frequent procedures. Third quartiles of the KAP distributions were used to set the RLs. A regular quality control of the X-ray systems and a calibration of the dose meters were performed during the survey. The fluoroscopy time and total number of digital subtraction angiography images per procedure were also analyzed. The RL values proposed were 12 Gy cm{sup 2} for fistulography (hemodialysis access; sample of 180 cases), 73 Gy cm{sup 2} for lower limb arteriography (685 cases), 89 Gy cm{sup 2} for renal arteriography (55 cases), 80 Gy cm{sup 2} for biliary drainage (205 cases), 289 Gy cm{sup 2} for hepatic chemoembolization (151 cases), 94 Gy cm{sup 2} for iliac stent (70 cases), and 236 Gy cm{sup 2} for uterine embolization (45 cases). The provisional national RL values are lower than those obtained in a similar survey carried out in the United States from 2002 to 2004. These new values could be used to improve the practice of centers consistently working with doses higher than the RLs. This national survey also had a positive impact, as it helped increase the awareness of the members of the National Society of IR on a topic as crucial as patient dose values and programs on radiation protection.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Creation of a Tumor-Mimic Model Using a Muscle Paste for Radiofrequency Ablation of the Lung

The purpose of this study was to develop an easily created tumor-mimic model and evaluate its efficacy for radiofrequency ablation (RFA) of the lung. The bilateral lungs of eight living adult swine were used. A tumor-mimic model was made by percutaneous injection of 1.0 ml muscle paste through the bone biopsy needle into the lung. An RFA probe was then inserted into the tumor mimics immediately after tumor creation. Ablation time, tissue impedance, and temperature were recorded. The tumor mimics and their coagulated regions were evaluated microscopically and macroscopically. The muscle paste was easily injected into the lung parenchyma through the bone biopsy needle and well visualized under fluoroscopy. In 10 of 12 sites the tumor mimics were oval shaped, localized, and homogeneous on gross specimens. Ten tumor mimics were successfully ablated, and four locations were ablated in the normal lung parenchyma as controls. In the tumor and normal lung parenchyma, ablation times were 8.9 {+-} 3.5 and 4.4 {+-} 1.6 min, respectively; tissue impedances at the start of ablation were 100.6 {+-} 16.6 and 145.8 {+-} 26.8 {Omega}, respectively; and temperatures at the end of ablation were 66.0 {+-} 7.9 and 57.5 {+-} 7.6{sup o}C, respectively. The mean size of tumor mimics was 13.9 x 8.2 mm, and their coagulated area was 18.8 x 13.1 mm. In the lung parenchyma, the coagulated area was 15.3 x 12.0 mm. In conclusion, our tumor-mimic model using muscle paste can be easily and safely created and can be ablated using the ablation algorithm in the clinical setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Percutaneous Retrieval of a Radiolucent Foreign Body from an EVAR Device by Combining Different Image Modalities

Percutaneous extraction techniques are an established method for removing endovascular foreign bodies. Generally, the foreign body to be removed is radiopaque (i.e., catheter and guidewire fragments, vena cava filters, embolization coils, endovascular stents). We propose an application of these techniques to remove a radiolucent foreign body (i.e., pigtail cover) by means of a combination of different imaging techniques (fluoroscopy, digital subtraction angiography, ultrasound, and computed axial tomography).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

C-arm Cone Beam Computed Tomographic Needle Path Overlay for Fluoroscopic-Guided Placement of Translumbar Central Venous Catheters

C-arm cone beam computed tomography is an advanced 3D imaging technology that is currently available on state-of-the-art flat-panel-based angiography systems. The overlay of cross-sectional imaging information can now be integrated with real-time fluoroscopy. This overlay technology was used to guide the placement of three percutaneous translumbar inferior vena cava catheters.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Temperature Measurement During Polymerization of Bone Cement in Percutaneous Vertebroplasty: An In Vivo Study in Humans

Aim of the study was to 'in vivo' measure temperature, during percutaneous vertebroplasty (PV), within a vertebral body injected with different bone cements. According to the declaration of Helsinki, 22 women (60-80 years; mean, 75 years) with painful osteoporotic vertebral collapse underwent bilateral transpedicular PV on 22 lumbar vertebrae. Two 10-G vertebroplasty needles were introduced into the vertebra under digital fluoroscopy; a 16-G radiofrequency thermoablation needle (Starburst XL; RITA Medical System Inc., USA), carrying five thermocouples, was than coaxially inserted. Eleven different bone cements were injected and temperatures were measured every 30 s until temperatures dropped under 45{sup o}C. After the thermocouple needle was withdrawn, bilateral PV was completed with cement injection through the vertebroplasty needle. Unpaired Student's t-tests, Kruskal-Wallis test, and Wilcoxon signed rank test were used to evaluate significant differences (p < 0.05) in peak temperatures, variations between cements, and clinical outcome. All procedures were completed without complications, achieving good clinical outcomes (p < 0.0001). Regarding average peak temperature, cements were divided into three groups: A (over 60{sup o}C), B (from 50{sup o} to 60{sup o}C), and C (below 50{sup o}C). Peak temperature in Group A (86.7 {+-} 10.7{sup o}C) was significantly higher (p = 0.0172) than that in Groups B (60.5 {+-} 3.7{sup o}C) and C (44.8 {+-} 2.6{sup o}C). The average of all thermocouples showed an extremely significant difference (p = 0.0002) between groups. None of the tested cements maintained a temperature {>=}45{sup o}C for more than 30 min. These data suggest that back-pain improvement is obtained not by thermal necrosis but by mechanical consolidation only. The relative necrotic thermal effect in vertebral metastases seems to confirm that analgesia must be considered the main intent of PV.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Central Vein Dilatation Prior to Concomitant Port Implantation

Implantation of subcutaneous port systems is routinely performed in patients requiring repeated long-term infusion therapy. Ultrasound- and fluoroscopy-guided implantation under local anesthesia is broadly established in interventional radiology and has decreased the rate of complications compared to the surgical approach. In addition, interventional radiology offers the unique possibility of simultaneous management of venous occlusion. We present a technique for recanalization of central venous occlusion and angioplasty combined with port placement in a single intervention which we performed in two patients. Surgical port placement was impossible owing to occlusion of the superior vena cava following placement of a cardiac pacemaker and occlusion of multiple central veins due to paraneoplastic coagulopathy, respectively. In both cases the affected vessel segments were dilated with balloon catheters and the port systems were placed thereafter. After successful dilatation, the venous access was secured with a 25-cm-long, 8-Fr introducer sheath, a subcutaneous pocket prepared, and the port catheter tunneled to the venipuncture site. The port catheter was introduced through the sheath with the proximal end connected to a 5-Fr catheter. This catheter was pulled through the tunnel in order to preserve the tunnel and, at the same time, allow safe removal of the long sheath over the wire. The port system functioned well in both cases. The combination of recanalization and port placement in a single intervention is a straightforward alternative for patients with central venous occlusion that can only be offered by interventional radiology.

62 RADIOLOGY AND NUCLEAR MEDICINE↗