Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FLOCCULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Global-, local-, and intermediate-scale structures in prototype spiral galaxies

The relationship between galactic spiral structure and the matter in the underlying disk constitutes one of the central problems in galactic dynamics. In Bertin et al. (1989), disk matter characterized by a low-dispersive speed is shown to be capable of playing a key role in the generation of large-scale spiral structure. In Roberts et al. (1992), this self-gravitating, low-dispersion disk matter is shown to be capable of playing an essential role in the formation of structure on local and intermediate scales. Both in computed cases where large-scale spiral structure is present and in those where it is not, the same dominant physical processes and fundamental dynamical mechanisms are active on local scales. The new perception, in which large-scale and small-scale phenomena operate somewhat independently as evidenced in the computational studies, permits a range of flocculent, multiarmed, and grand design spiral types to be simulated. In particular, grand design galaxies with ragged appearances exhibiting spurs, arm branchings, and interarm bridges in addition to the major spiral arms, similar to those often observed, can be generated.

Roberts, William W., Jr.↗

Analysis of the distribution of pitch angles in model galactic disks - Numerical methods and algorithms

An automated mathematical method capable of successfully isolating the many different features in prototype and observed spiral galaxies and of accurately measuring the pitch angles and lengths of these individual features is developed. The method is applied to analyze the evolution of specific features in a prototype galaxy exhibiting flocculent spiral structure. The mathematical-computational method was separated into two components. Initially, the galaxy was partitioned into dense regions constituting features using two different methods. The results obtained using these two partitioning algorithms were very similar, from which it is inferred that no numerical biasing was evident and that capturing of the features was consistent. Standard least-squares methods underestimated the true slope of the cloud distribution and were incapable of approximating an orientation of 45 deg. The problems were overcome by introducing a superior fit least-squares method, developed with the intention of calculating true orientation rather than a regression line.

Russell, William S.↗

Biogeochemistry of fluoride in a plant-solution system

Fluoride (F-) pollutants can harm plants and the animals feeding on them. However, it is largely unknown how complexing and chelating agents affect F bioavailability. Two studies were conducted that measured F- bioavailability and uptake by rice (Oryza sativa L.). In the first study, rice was grown in solution culture (pH 5.0) with 0, 2, or 4 mM F- as KF to compare the interaction of F- with humic acid (HA) and with a conventional chelating agent, N-hydroxyethylenthylenediaminetriacetic acid (HEDTA). In the second study, F was supplied at 0, 0.5, 1.0, and 2.0 mM KF with an additional 2 mM F- treatment containing solution Ca at 2x (2 mM Ca) the level used in the first study, to test the effect added Ca had on F- availability and uptake. Total biomass was greatest with HEDTA and F- < 1 mM. Leaf and stem F concentrations increased exponentially as solution F- increased linearly, with nearly no F partitioning into the seed. Results suggest that F was taken up as HF0 while F- uptake was likely restricted. Additionally, F- competed with HA for Ca, thus preventing the formation of Ca-HA flocculents. The addition of soluble Ca resulted in the precipitation of CaF2 solids on the root surface, as determined by tissue analysis and energy dispersive X-ray spectroscopy.

NASA Discipline Life Support Systems↗

Beneficial effects of humic acid on micronutrient availability to wheat

Humic acid (HA) is a relatively stable product of organic matter decomposition and thus accumulates in environmental systems. Humic acid might benefit plant growth by chelating unavailable nutrients and buffering pH. We examined the effect of HA on growth and micronutrient uptake in wheat (Triticum aestivum L.) grown hydroponically. Four root-zone treatments were compared: (i) 25 micromoles synthetic chelate N-(4-hydroxyethyl)ethylenediaminetriacetic acid (C10H18N2O7) (HEDTA at 0.25 mM C); (ii) 25 micromoles synthetic chelate with 4-morpholineethanesulfonic acid (C6H13N4S) (MES at 5 mM C) pH buffer; (iii) HA at 1 mM C without synthetic chelate or buffer; and (iv) no synthetic chelate or buffer. Ample inorganic Fe (35 micromoles Fe3+) was supplied in all treatments. There was no statistically significant difference in total biomass or seed yield among treatments, but HA was effective at ameliorating the leaf interveinal chlorosis that occurred during early growth of the nonchelated treatment. Leaf-tissue Cu and Zn concentrations were lower in the HEDTA treatment relative to no chelate (NC), indicating HEDTA strongly complexed these nutrients, thus reducing their free ion activities and hence, bioavailability. Humic acid did not complex Zn as strongly and chemical equilibrium modeling supported these results. Titration tests indicated that HA was not an effective pH buffer at 1 mM C, and higher levels resulted in HA-Ca and HA-Mg flocculation in the nutrient solution.

Non-NASA Center↗

A model for the kinetics of homotypic cellular aggregation under static conditions

We present the formulation and testing of a mathematical model for the kinetics of homotypic cellular aggregation. The model considers cellular aggregation under no-flow conditions as a two-step process. Individual cells and cell aggregates 1) move on the tissue culture surface and 2) collide with other cells (or aggregates). These collisions lead to the formation of intercellular bonds. The aggregation kinetics are described by a system of coupled, nonlinear ordinary differential equations, and the collision frequency kernel is derived by extending Smoluchowski's colloidal flocculation theory to cell migration and aggregation on a two-dimensional surface. Our results indicate that aggregation rates strongly depend upon the motility of cells and cell aggregates, the frequency of cell-cell collisions, and the strength of intercellular bonds. Model predictions agree well with data from homotypic lymphocyte aggregation experiments using Jurkat cells activated by 33B6, an antibody to the beta 1 integrin. Since cell migration speeds and all the other model parameters can be independently measured, the aggregation model provides a quantitative methodology by which we can accurately evaluate the adhesivity and aggregation behavior of cells.

Non-NASA Center↗

Visualization of newt aragonitic otoconial matrices using transmission electron microscopy

Otoconia are calcified protein matrices within the gravity-sensing organs of the vertebrate vestibular system. These protein matrices are thought to originate from the supporting or hair cells in the macula during development. Previous studies of mammalian calcitic, barrel-shaped otoconia revealed an organized protein matrix consisting of a thin peripheral layer, a well-defined organic core and a flocculent matrix inbetween. No studies have reported the microscopic organization of the aragonitic otoconial matrix, despite its protein characterization. Pote et al. (1993b) used densitometric methods and inferred that prismatic (aragonitic) otoconia have a peripheral protein distribution, compared to that described for the barrel-shaped, calcitic otoconia of birds, mammals, and the amphibian utricle. By using tannic acid as a negative stain, we observed three kinds of organic matrices in preparations of fixed, decalcified saccular otoconia from the adult newt: (1) fusiform shapes with a homogenous electron-dense matrix; (2) singular and multiple strands of matrix; and (3) more significantly, prismatic shapes outlined by a peripheral organic matrix. These prismatic shapes remain following removal of the gelatinous matrix, revealing an internal array of organic matter. We conclude that prismatic otoconia have a largely peripheral otoconial matrix, as inferred by densitometry.

NASA Discipline Neuroscience↗

Automated titration method for use on blended asphalts

A system for determining parameters and compatibility of a substance such as an asphalt or other petroleum substance uses titration to highly accurately determine one or more flocculation occurrences and is especially applicable to the determination or use of Heithaus parameters and optimal mixing of various asphalt stocks. In a preferred embodiment, automated titration in an oxygen gas exclusive system and further using spectrophotometric analysis (2-8) of solution turbidity is presented. A reversible titration technique enabling in-situ titration measurement of various solution concentrations is also presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Methods for preparing colloidal nanocrystal-based thin films

Methods of exchanging ligands to form colloidal nanocrystals (NCs) with chalcogenocyanate (xCN)-based ligands and apparatuses using the same are disclosed. The ligands may be exchanged by assembling NCs into a thin film and immersing the thin film in a solution containing xCN-based ligands. The ligands may also be exchanged by mixing a xCN-based solution with a dispersion of NCs, flocculating the mixture, centrifuging the mixture, discarding the supernatant, adding a solvent to the pellet, and dispersing the solvent and pellet to form dispersed NCs with exchanged xCN-ligands. The NCs with xCN-based ligands may be used to form thin film devices and/or other electronic, optoelectronic, and photonic devices. Devices comprising nanocrystal-based thin films and methods for forming such devices are also disclosed. These devices may be constructed by depositing NCs on to a substrate to form an NC thin film and then doping the thin film by evaporation and thermal diffusion.

36 MATERIALS SCIENCE↗

Compositions and methods for treating contaminated water

A recombinant Moringa oleifera coagulant protein (MO) produced and secreted by Bacillus has coagulation/flocculation activity. The MO protein and the Bacillus host cells expressing the MO protein can be used in compositions and methods for treating contaminated water, such as drinking water or waste water. The MO protein can coagulate or flocculate suspended solid impurities in the water, which can then be removed.

Arnett, Clint M.↗

On-Site Pilot Study - Removal of Uranium, Radium-226 and Arsenic from Impacted Leachate by Reverse Osmosis - 13155

Conestoga-Rovers and Associates (CRA-LTD) performed an on-site pilot study at the Welcome Waste Management Facility in Port Hope, Ontario, Canada, to evaluate the effectiveness of a unique leachate treatment process for the removal of radioactive contaminants from leachate impacted by low-level radioactive waste. Results from the study also provided the parameters needed for the design of the CRA-LTD full scale leachate treatment process design. The final effluent water quality discharged from the process to meet the local surface water discharge criteria. A statistical software package was utilized to obtain the analysis of variance (ANOVA) for the results from design of experiment applied to determine the effect of the evaluated factors on the measured responses. The factors considered in the study were: percent of reverse osmosis permeate water recovery, influent coagulant dosage, and influent total dissolved solids (TDS) dosage. The measured responses evaluated were: operating time, average specific flux, and rejection of radioactive contaminants along with other elements. The ANOVA for the design of experiment results revealed that the operating time is affected by the percent water recovery to be achieved and the flocculant dosage over the range studied. The average specific flux and rejection for the radioactive contaminants were not affected by the factors evaluated over the range studied. The 3 month long on-site pilot testing on the impacted leachate revealed that the CRA-LTD leachate treatment process was robust and produced an effluent water quality that met the surface water discharge criteria mandated by the Canadian Nuclear Safety Commission and the local municipality. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Utilizing a Novel Acoustic Backscatter Array to Characterize Waste Consolidation and Settling in a Horizontal Flow Clarifier - 16051

As part of a collaboration between the University of Leeds, Sellafield Ltd and MMI Engineering Ltd, bespoke acoustic instrumentation and numerical simulation methods have been established to optimize nuclear legacy waste transfers. Specifically, a new ultrasonic measurement system has been developed, allowing suspended particle concentration and consolidation to be measured remotely. This technology has been combined with computational fluid dynamics (CFD) modelling of settling particulate systems, permitting full characterization, simulation and prediction of sludge separation processes. Presented here are experimental and numerical results on the transport and settling behavior of non-active nuclear-analogue suspensions in two flow geometries: gravitational settling of glass dispersions in a 250-liter column; and transport and sedimentation of flocculated calcite in a close-to-full-scale clarifier (9 m{sup 3} total volume and 4.8 m{sup 2} length). In addition, details of the design, construction and calibration of a custom-built Ultrasonic Array Research Platform (UARP) are described. Settling column results suggested that particle concentration changes could be simulated with good accuracy by a CFD model (developed using the open source OpenFOAM framework) when compared to measured samples. Large-scale clarifier trials were used to assess the effectiveness of the UARP controller with an attached in situ acoustic backscatter array (ABA). The ABA consisted of 8 transducers angled down at 20 deg. to the vertical, pulsing at 2-2.5 MHz in cycles (covering 1.8 m total depth). In comparison to a range of sampled concentrations across the length of the clarifier, results confirmed that the UARP-ABA system was highly successful at characterizing these complex flows over several hours of operation, allowing visualization of depth-wise bulk density changes and bed build-up over time. Collectively, this work highlights the capability of these tools to monitor and optimize a number of current waste transfer operations at Sellafield, with further potential applications for solid-liquid separations across waste, water treatment and minerals engineering industries. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Conventional and Next Generation Treatment Technologies for PFAS - 20067

In 2016, the United States Environmental Protection Agency (USEPA) established a Health Advisory Limit (HAL) for perfluorooctanoic acid (PFOA) and perfluorooctane sulfonic acid (PFOS) (individually and the summation) of 70 nanograms per liter (ng/L) based on developing toxicological information. These two compounds are among several thousand per- and polyfluoroalkyl substances (PFAS). Due to a multitude of commercially beneficial physical and chemical properties, the availability of PFAS-relevant and practical water treatment technologies is limited. The use of conventional adsorbents, such as activated carbon (AC) and anion exchange (AIX) resins, have become a 'de facto' interim measure to immediately address drinking water above this criterion. However, these adsorbents can have marginal long-term efficiency and are relatively unproven against the diversity of polyfluorinated compounds. Additionally, geochemical and/or co-contaminant competition can significantly impede adsorption based PFAS removal. These challenges may be addressed using engineered filtration, such as reverse osmosis or nanofiltration (RO/NF); however, for larger flow systems RO/NF may have unacceptable reject ratios as high as 35% and the capital cost may preclude these technologies. Extending these technologies to natural waters, which have various degrees of geochemical and co-contaminant competition, often requires a treatment train, combining conventional adsorbents or engineered filtration with pretreatment and more innovative and emerging remediation solutions for PFAS. Conventional and Next Generation water treatment technologies for PFAS generally employ one of three mechanisms (adsorption, separation, or destruction). These mechanisms include many types of technologies for both municipal drinking water and extracted natural water applications. The previously mentioned AC, AIX, and RO/NF are commercially available technologies that are actively being deployed for PFAS treatment. Research and development around these technologies is focused on optimization, and ultimate destruction of PFAS is achieved through incineration. Next Generation water treatment technologies include PFAS-specific flocculants, foam fractionation, novel AIX resins, new engineered adsorptive media, electrochemical treatment, sonolysis, and photolysis, radiation, and plasma (forms of advanced reductive processes [ARP]). Research and development around these technologies is focused on proof of concept and assimilation to real world applications. As the PFAS-relevant destructive technologies (such as incineration, electrochemical treatment, sonolysis, and ARP) are energy intensive, the state of the practice for PFAS water treatment is to focus adsorption/separation based technologies on reducing and concentrating the volume of water requiring destructive treatment. This enables more flexibility with respect to circulation frequency, residence time, and more control over energy usage. Water treatment for PFAS presently requires multiple technologies (i.e. a treatment train) to protect human health in a cost-conscious manner. An investment in research and development to explore new technologies is part of a key initiative for efficient protection of human health. This presentation attempts to review PFAS-relevant water treatment technologies and provide perspective as to their status with respect to applicability and commercial relevance. (authors)

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Iodine Co-Precipitation with Calcium Carbonate in the Presence of Silica Ions - 20360

Historical releases of I-129 to the subsurface at the U.S. Department of Energy Hanford Site have resulted in large dilute plumes that cover an area of over 50 km{sup 2}. The most concentrated I-129 plume is associated with the 200 West Area in the 200-UP-1 operable unit of the Hanford Central Plateau, where peak concentrations have been measured up to 30 times the drinking water standard of 1 pCi/L. The mobility of iodine depends on many factors, including chemical speciation, pH, redox conditions, as well as the presence of organic matter, calcium carbonate minerals and microbial activities. Speciation measurements estimate that the majority of the iodine (∼76%) in Hanford groundwater exists as iodate. Information on processes that affect iodate mobility in the Hanford subsurface support evaluation of environmental management options for the I-129 plumes. Iodate can be incorporated into calcium carbonate, which is a potential mechanism of naturally attenuating radioiodine in groundwater. However, the silica content in porewater may impact the contaminant-calcium carbonate incorporation process. Silica is one of the most abundant elements in nature and can have an impact on chemical weathering of alkaline-earth carbonates in the environment. Hence, this research aims to advances knowledge of the iodine co-precipitation process with calcium carbonate in the presence of silica. This information supports the technical basis evaluation of natural attenuation for I-129. Samples for these studies were prepared using calcium carbonate-forming solutions that included certified grade sodium meta-silicate nonahydrate (Na{sub 2}SiO{sub 3}), calcium chloride dehydrate (CaCl{sub 2}.2H{sub 2}O), sodium carbonate (NaCO{sub 2}), and sodium hydroxide (NaOH) solutions for pH adjustments. Triplicate samples were prepared with silica concentrations in the solution of 0 mM, 0.5 mM and 20 mM, mixed with an iodate standard (1000 ppm of IO{sub 3}{sup -} in H{sub 2}O) and sampled over a one-week period. Preliminary data analyses suggest that less iodine remains in solution in the presence of silica (average remaining aqueous fraction 0.23±0.03 at 20 mM of Si) relative to samples without silica (0.52±0.06); an indication that more iodine has been sorbed or incorporated into precipitates. However, the mechanisms for this behavior are still under investigation and need to be interpreted relative to pore water compositions that are representative of Hanford site-specific conditions. Scanning electron microscope equipped with energy dispersive spectroscopy (SEM-EDS) analyses were performed to observe the solid phase morphology in these experiments and showed rhombohedral calcite crystals covered with amorphous Si floccules. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Beneficial rheological properties of lithium-ion battery cathode slurries from elevated mixing and coating temperatures

It is crucial that lithium-ion battery manufacturers implement strategies to expedite production without sacrificing quality due to rising consumer demand. Cathode coating is commonly performed at the industrial scale with a slot-die coater. In slot-die coating, substrate velocity is maximized and imperfections (such as air entrainment and thickness variations) are minimized by reducing the viscosity of the material being coated. A simple, scalable technique of reducing the viscosity of the cathode slurry is to increase its temperature, though it is dire that this heat does not cause irreversible gelation or otherwise deteriorate the slurry constituents. Cathode slurries were prepared at different mixing temperatures between 25 °C and 75 °C and their flow behavior was studied at their mixing temperature. At practical shear rates, the slurry coated at 60 °C was 23% less viscous than that coated at 25 °C, meaning the critical coating speed could be increased by roughly 14% at 60 °C. Between 25 °C and 60 °C, the slurries’ yield stress and equilibrium storage modulus increased monotonically, providing the additional benefit of higher sedimentation resistance of the active materials. To examine the influence of temperature on coating morphology and electrochemical performance, slurries were prepared and coated at 25 °C and 60 °C. Micrographs revealed no superficial differences between coatings. The electrode coated at 60 °C demonstrated comparable capacity retention during long-term cycling and high-rate discharge testing when compared to the electrode coated at 25 °C. The findings of this study indicate that warmer mixing and coating operations serve to maximize cathode productivity, particularly if advancements can be made in industrial-scale electrode drying.

25 ENERGY STORAGE↗

REMOVAL OF SOLIDS FROM HIGHLY ENRICHED URANIUM SOLUTIONS USING THE H-CANYON CENTRIFUGE

Prior to the dissolution of Pu-containing materials in HB-Line, highly enriched uranium (HEU) solutions stored in Tanks 11.1 and 12.2 of H-Canyon must be transferred to provide storage space. The proposed plan is to centrifuge the solutions to remove solids which may present downstream criticality concerns or cause operational problems with the 1st Cycle solvent extraction due to the formation of stable emulsions. An evaluation of the efficiency of the H-Canyon centrifuge concluded that a sufficient amount (> 90%) of the solids in the Tank 11.1 and 12.2 solutions will be removed to prevent any problems. We based this conclusion on the particle size distribution of the solids isolated from samples of the solutions and the calculation of particle settling times in the centrifuge. The particle size distributions were calculated from images generated by scanning electron microscopy (SEM). The mean particle diameters for the distributions were 1-3 {micro}m. A significant fraction (30-50%) of the particles had diameters which were < 1 {micro}m; however, the mass of these solids is insignificant (< 1% of the total solids mass) when compared to particles with larger diameters. It is also probable that the number of submicron particles was overestimated by the software used to generate the particle distribution due to the morphology of the filter paper used to isolate the solids. The settling times calculated for the H-Canyon centrifuge showed that particles with diameters less than 1 to 0.5 {micro}m will not have sufficient time to settle. For this reason, we recommend the use of a gelatin strike to coagulate the submicron particles and facilitate their removal from the solution; although we have no experimental basis to estimate the level of improvement. Incomplete removal of particles with diameters < 1 {micro}m should not cause problems during purification of the HEU in the 1st Cycle solvent extraction. Particles with diameters > 1 {micro}m account for > 99% of the solid mass and will be efficiently removed by the centrifuge; therefore, the formation of emulsions during solvent extraction operations is not an issue. Under the current processing plan, the solutions from Tanks 11.1 and 12.2 will be transferred to the enriched uranium storage (EUS) tank following centrifugation. The solution from Tanks 11.1 and 12.2 may remain in the EUS tank for an extended time prior to purification. The effects of extended storage on the solution were not evaluated as part of this study.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

TREATABILITY TEST REPORT FOR THE REMOVAL OF CHROMIUM FROM GROUNDWATER AT 100-D AREA USING ELECTROCOAGULATION

The U.S. Department of Energy (DOE) has committed to accelerate cleanup of contaminated groundwater along the Columbia River. The current treatment approach was driven by a series of Interim Action Records of Decision (IAROD) issued in the mid-1990s. Part of the approach for acceleration involves increasing the rate of groundwater extraction for the chromium plume north of the 100-D Reactor and injecting the treated water in strategic locations to hydraulically direct contaminated groundwater toward the extraction wells. The current treatment system uses ion exchange for Cr(VI) removal, with off-site regeneration of the ion exchange resins. Higher flow rates will increase the cost and frequency of ion exchange resin regeneration; therefore, alternative technologies are being considered for treatment at high flow rates. One of these technologies, electrocoagulation (EC), was evaluated through a pilot-scale treatability test. The primary purpose of the treatability study was to determine the effectiveness of Cr(VI) removal and the robustness/implementability of an EC system. Secondary purposes of the study were to gather information about derivative wastes and to obtain data applicable to scaling the process from the treatability scale to full-scale. The treatability study work plan identified a performance objective and four operational objectives. The performance objective for the treatability study was to determine the efficiency (effectiveness) of hexavalent chromium removal from the groundwater, with a desired concentration of {le} 20 micrograms per liter ({micro}g/L) Cr(VI) in the effluent prior to re-injection. Influent and effluent total chromium and hexavalent chromium data were collected using a field test kit for multiple samples per week, and from off-site laboratory analysis of samples collected approximately monthly. These data met all data quality requirements. Two of three effluent chromium samples analyzed in the off-site (that is, fixed) laboratory met the performance objective during the continuous operational testing. Effluent hexavalent chromium analyzed by the field laboratory met the performance goal in over 90 percent of the samples. All effluent hexavalent chromium samples during the batch testing with high influent hexavalent chromium concentrations ({approx}2000 {micro}g/L) met the performance objective. Although the EC system was able to meet the performance goal, it must be noted that it was not uncommon for the system to be operated in recycle mode to achieve the performance goal. The EC unit was sometimes, but not always, capable of a single pass treatment efficiency high enough to meet the performance goal, and recycling water for multiple treatment passes was effective. An operational objective was to determine the volume and composition of the waste streams to enable proper waste designation. The toxicity characteristic leaching procedure (TCLP) concentrations, pH, and free liquids were determined for solid material from the EC electrodes (mechanically removed scale), the filter press, and the tank bottoms for the effluent and waste collector tanks. These data met all data quality requirements. All solid-phase secondary waste streams were found to be below the TCLP limits for the toxicity characteristic, and a pH value within the limits for the corrosivity characteristic. Out of three samples, two (one of scale from the EC unit and one from filter press solids) failed the free liquid (paint filter) test, which is one of the acceptability criteria for Hanford's Environmental Restoration Disposal Facility (ERDF). The solid-phase waste generation rate was about 0.65-gallon of solid waste per 100 gallons of water treated. It is concluded that the solid-phase secondary waste generated from this technology under the conditions at the test site will meet the toxicity and corrosivity criteria for disposal. It is also concluded that with engineering and/or operational improvements, a solid-phase secondary waste could be produced that would meet the free liquid disposal requirements. The second operational objective was to assess the operational reliability and safety of the system. For the continuous operations testing period from July 23 to September 12,2007, the system was not able to operate unattended. An extensive period of startup and adjustment preceded continuous operations, but was unsuccessful in providing a suitable and robust operating condition. Primary operational reliability problems were related to the sensitivity of the solid separation process to operational conditions such that a robust operating procedure (for example, chemical dosage) was not identified during the treatability test. Poor solids separation and high effluent iron concentrations also led to operational difficulties associated with injection well fouling.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗