Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Experiment Optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Volatile fatty acid extraction from fermentation broth using a hydrophobic ionic liquid and in situ enzymatic esterification

Efficient recovery of volatile fatty acids (VFAs) from fermentation broth is a challenge due to low VFA titers and thus limits the commercialization of VFA production using biological routes. Liquid–liquid extraction using hydrophobic ionic liquids (ILs) shows great promise for the extraction and esterification of hydrophilic VFAs. In this study, several ILs were evaluated to select a water-immiscible and efficient extraction solvent. The selected IL, trihexyltetradecyl phosphonium dibutylphosphate ([P 666,14 ][DBP]), gave a cumulative VFA extraction of around 842.8 mg per g IL. The predicted excess enthalpy (H E ) and logarithmic activity coefficients ln(γ) using the COSMO-RS model were validated with the experimentally obtained VFA recovery from fermentation broth. To understand the extraction mechanism of VFAs, quantum theory of atoms in molecules (QTAIM) and noncovalent interaction (NCI) were performed. The results suggest that long chain fatty acids exhibit strong van der Waals interaction with the DBP anion leading to higher VFA extraction. The enzymatic esterification of VFAs with ethanol in [P 666,14 ][DBP] was optimized using the Box–Behnken response surface design of experiment. Under the optimized conditions, up to 83.7% of hexanoic acid was converted to ethyl esters, while other shorter chain VFAs have lower conversion efficiency (38.3–63.2%).

09 BIOMASS FUELS↗

Analysis and Optimization of Seismo-Acoustic Monitoring Networks with Bayesian Optimal Experimental Design

The Bayesian optimal experimental design (OED) problem seeks to identify data, sensor configurations, or experiments which can optimally reduce uncertainty. The goal of OED is to find an experiment that maximizes the expected information gain (EIG) about quantities of interest given prior knowledge about expected data. Therefore, within the context of seismic monitoring, we can use Bayesian OED to configure sensor networks by choosing sensor locations, types, and fidelity in order to improve our ability to identify and locate seismic sources. In this work, we develop the framework necessary to use Bayesian OED to optimize the ability to locate seismic events from arrival time data of detected seismic phases. In order to do utilize Bayesian OED we must develop four elements:1. A likelihood function that describes the uncertainty of detection and travel times; 2. A Bayesian solver that takes a prior and likelihood to identify the posterior; 3. An algorithm to compute EIG; and, 4. An optimizer that finds a sensor network which maximizes EIG. Once we have developed this framework, we can explore many relevant questions to monitoring such as: how and what multiphenomenology data can be used to optimally reduce uncertainty, how to trade off sensor fidelity and earth model uncertainty, and how sensor types, number, and locations influence uncertainty

47 OTHER INSTRUMENTATION↗

Robust A-Optimal Experimental Design for Sensor Placement in Bayesian Linear Inverse Problems

Optimal design of experiments for Bayesian inverse problems has recently gained wide popularity and attracted much attention, especially in the computational science and Bayesian inversion communities. An optimal design maximizes a predefined utility function that is formulated in terms of the elements of an inverse problem, an example being optimal sensor placement for parameter identification. The state-of-the-art algorithmic approaches following this simple formulation generally overlook misspecification of the elements of the inverse problem, such as the prior or the measurement uncertainties. This work presents an efficient algorithmic approach for designing optimal experimental design schemes for Bayesian linear inverse problems such that the optimal design is robust to misspecification of elements of the inverse problem. Specifically, we consider a worst-case scenario approach for the uncertain or misspecified parameters, formulate robust objectives, and propose an algorithmic approach for optimizing such objectives. Furthermore, both relaxation and stochastic solution approaches are discussed with detailed analysis and insight into the interpretation of the problem and the proposed algorithmic approach. Extensive numerical experiments to validate and analyze the proposed approach are carried out for sensor placement in a parameter identification problem.

Bayesian inverse problems↗

Drive-pressure optimization in ramp-wave compression experiments through differential evolution

Ramp-wave dynamic-compression experiments are used to examine quasi-isentropic loading paths in materials. The gradual and continuous increase in pressure created by ramp waves make these types of experiments ideal for studying nonequilibrium material behavior, such as solidification kinetics. In ramp-wave compression experiments, the input drive pressure to the experimental setup may be exerted through one of a number of different mechanisms (e.g., magnetic fields, gas-gun-driven impactors, or high-energy lasers) and is generally required for simulating such experiments. Yet, regardless of the specific mechanism, this drive pressure cannot be measured directly (measurements are generally taken at a location near the back of the experimental setup through a transparent window), leading to an inverse problem where one must determine the drive pressure at the front of the experimental setup (i.e., the input) that corresponds to the particle velocity (the output) measured near the back of the experimental setup. Furthermore, we solve this inverse problem using a heuristic optimization algorithm, known as differential evolution, coupled with a multiphysics, hydrodynamics code that simulates the compression of the experimental setup. By running many rounds of forward simulations of the experimental setup, our optimization process iteratively searches for a drive pressure that is optimized to closely reproduce the experimentally measured particle velocity near the back of the experimental setup. While our optimization methodology requires a significant number of hydrodynamics simulations to be conducted, many of these can be performed in parallel, which greatly reduces the time cost of our methodology. One novel aspect of our method for determining the drive pressure is that it does not require physical modeling of the drive mechanism and can thus be broadly applied to many types of ramp-compression experiments, regardless of the drive mechanism.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Leveraging visible and near-infrared spectroelectrochemistry to calibrate a robust model for Vanadium(IV/V) in varying nitric acid and temperature levels

Spectroelectrochemistry and optimal design of experiments can be used to rapidly build accurate models for species quantification and enable a greater level of process awareness. Optical spectroscopy can provide vital elemental and molecular information, but several hurdles must be overcome before it can become a widely adopted analytical method for remote analysis in the nuclear field. Analytes with varying oxidation state, acid concentration, and fluctuating temperature must be efficiently accounted for to minimize time and resources in restrictive hot cell environments. The classic one-factor-at-a-time approach is not suitable for frequent calibration/maintenance operations in this setting. Therefore, a novel alternative was developed to characterize a system containing vanadium(IV/V) (0.01–0.1 M), nitric acid (0.1–4 M), and varying temperatures (20–45 °C). Here, spectroelectrochemistry methods were used to acquire a sample set selected by optimal design of experiments. This new approach allows for the accurate analysis of vanadium and HNO 3 concentration by leveraging UV–Vis–NIR absorption spectroscopy with robust and accurate chemometric models. The top model's root mean squared error of prediction percent values were 3.47%, 4.06%, 3.40%, and 10.9% for V(IV), V(V), HNO 3 , and temperature, respectively. These models, efficiently developed using the designed approach, exhibited strong predictive accuracy for vanadium and acid with varying oxidation states and temperature using only spectrophotometry, which advances current technology for real-world hot cell applications. Additionally, Nernstian analysis of the V(IV/V) standard potential was performed using traditional absorbance methods and multivariate curve resolution (MCR). The successful tests demonstrated that MCR Nernst tests may be valuable in highly convoluted spectral systems to better understand the redox processes' behavior.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Development of an Optimized Gasoline Surrogate Formulation for PACE Experiments and Simulations

New powertrain solutions are needed to address societal challenges stemming in part from a transportation sector which relies heavily on combustion of conventional hydrocarbon fuels like gasoline. One way to advance new solutions is through predictive simulations. Predictive simulations can potentially limit the extent of experimental validations, reduce time spent in engineering design cycles, unlock new strategies for high efficiency combustion with power density, and minimize tailpipe emissions. However, the simulation tools currently available are either too computationally expensive, inadequate in their accuracy, or a combination of the two. A DOE-funded consortium of national laboratories called the Partnership to Advance Combustion Engines (PACE) seeks to address this gap by rapidly delivering new knowledge and tools which enable market-competitive powertrain solutions for light-duty vehicles. Approaches to modeling combustion in powertrain systems typically incorporate computational fluid dynamics (CFD) simulations with chemical kinetic models. These CFD simulations generally use surrogate fuels featuring a limited number of existing components in a reduced kinetic model to limit computational costs. Such surrogate fuels often sacrifice matching several or more combustion and physical properties of the target gasoline fuel. Validation of surrogate fuels is also often only pursued for a small subset of standard metrics such as research or motor octane number (RON, MON). The purpose of this project is to develop an optimal E10 gasoline surrogate fuel suitable for tasks across PACE to facilitate rapid common analysis and progression toward consortium goals. This project received contributions from tasks led by eight PACE principal investigators. The project funding here reflects all tasks under Pitz, whose tasks also contributed to additional PACE projects. Based on the optimal gasoline surrogate fuel composition, a reduced chemical kinetic model will be shared with PACE researchers, industry, and the broader combustion community.

33 ADVANCED PROPULSION SYSTEMS↗

Optimization of Spirulina for biomanufacturing and the delivery of protein therapeutics

Lumen Bioscience has developed a novel cyanobacterial platform that enormously decreases the cost of pharmaceuticals used to prevent and treat illnesses. Arthrospira platensis (spirulina), is a photosynthetic microorganism that has been consumed as a dietary supplement for centuries in part because of its high protein content. Commercial cultivation operations have matured over the last 50 years to allow large-scale cultivation in outdoor ponds. Lumen recently discovered methods that transform this commercially important cyanobacterium into a genetically tractable platform for bioengineering. The high protein accumulation in spirulina makes it an ideal chassis for heterologous protein expression, and centuries of safe human consumption suggest its utility as an administration vehicle for biologic drugs. Lumen can express a broad range of recombinant proteins in spirulina and has developed manufacturing processes and strains to mucosally deliver bioactive proteins to treat and/or prevent disease. For example, Lumen has produced an oral cocktail of dried whole-cell spirulina biomass, containing 3 toxin-neutralizing antibodies and 1 endolysin, that is efficacious in a preclinical in vivo models of C. difficile infection. Lumen has also demonstrated that intranasal administration of a spirulina-manufactured neutralizing antibody can prevent disease by a respiratory pathogen, SARS-CoV-2, in a hamster model. Lumen’s current pipeline includes therapeutics to treat or prevent C. difficile infection, COVID-19, inflammatory bowel disease, cardiometabolic disease, and traveler’s diarrhea. Lumen deploys strategies to maximize the expression of these therapeutics for optimal dose sizing, a key limiting factor with past food crop-based expression systems. Spirulina can express exogenous proteins at unusually high levels (>15% of dry weight) but reaching this maximum value requires optimization of multiple interacting factors. We describe our current statistics design of experiments approach that optimizes these factors with minimal replicates. This maximizes exogenous protein expression allowing Lumen to generate spirulina-based therapeutics for a rapidly expanding range of medical uses.

Heinnickel, Mark↗

Integrating novel stellarator single-stage optimization algorithms to design the Columbia stellarator experiment

Abstract The Columbia Stellarator eXperiment (CSX), currently being designed at Columbia University, aims to test theoretical predictions related to QA plasma behavior, and to pioneer the construction of an optimized stellarator using three-dimensional, non-insulated high-temperature superconducting (NI-HTS) coils. The magnetic configuration is generated by a combination of two circular planar poloidal field (PF) coils and two 3D-shaped interlinked (IL) coils, with the possibility to add windowpane coils to enhance shaping and experimental flexibility. The PF coils and vacuum vessel are repurposed from the former Columbia Non-Neutral Torus experiment, while the IL coils will be custom-wound in-house using NI-HTS tapes. To obtain a plasma shape that meets the physics objectives with a limited number of coils, novel single-stage optimization techniques are employed, optimizing both the plasma and coils concurrently, in particular targeting a tight aspect ratio QA plasma and minimized strain on the HTS tape. Despite the increased complexity due to the expanded degrees of freedom, these methods successfully identify optimized plasma geometries that can be realized by coils meeting engineering specifications. This paper discusses the derivation of the constraints and objectives specific to CSX, and describe how two recently developed single-stage optimization methodologies are applied to the design of CSX. A set of selected configurations for CSX is then described in detail.

Baillod, A. (ORCID:0000000303529180)↗

Posiform planting: generating QUBO instances for benchmarking

We are interested in benchmarking both quantum annealing and classical algorithms for minimizing quadratic unconstrained binary optimization (QUBO) problems. Such problems are NP-hard in general, implying that the exact minima of randomly generated instances are hard to find and thus typically unknown. While brute forcing smaller instances is possible, such instances are typically not interesting due to being too easy for both quantum and classical algorithms. In this contribution, we propose a novel method, called posiform planting , for generating random QUBO instances of arbitrary size with known optimal solutions, and use those instances to benchmark the sampling quality of four D-Wave quantum annealers utilizing different interconnection structures (Chimera, Pegasus, and Zephyr hardware graphs) and the simulated annealing algorithm. Posiform planting differs from many existing methods in two key ways. It ensures the uniqueness of the planted optimal solution, thus avoiding groundstate degeneracy, and it enables the generation of QUBOs that are tailored to a given hardware connectivity structure, provided that the connectivity is not too sparse. Posiform planted QUBOs are a type of 2-SAT boolean satisfiability combinatorial optimization problems. Our experiments demonstrate the capability of the D-Wave quantum annealers to sample the optimal planted solution of combinatorial optimization problems with up to 5, 627 qubits.

97 MATHEMATICS AND COMPUTING↗

Nuclear data covariances are critical input to determine upper sub-critical limits and to design experiments to increase it [Slides]

This presentation discusses how Upper Subcritical Limits (USL) are key parameters to determine operational limits in nuclear criticality safety evaluations. It also discusses an example of plutonium casting operation using tantalum at LANL PF-4. The Whisper tool at Los Alamos relies on many inputs, including covariance data, leading the presentation to ask if an existing benchmark data be used in Whisper to adjust nuclear data and covariances to justify a higher USL. If not, Whisper can be used to help design an optimal new benchmark experiment. The presentation also seeks to determine what the possible impacts are on USL and operational limits for plutonium casting. In conclusion, nuclear data covariances are used for by Whisper for: GSSL adjustment of nuclear data and covariances, identification of most similar existing benchmark experiments to application, simulation of Upper Subcritical Limit of application, and input to optimization techniques for designing most appropriate new benchmark experiment(s) to meet requirements. This requires a complete set of nuclear data covariances, benchmarks and k-effective sensitivity profiles (for both benchmarks and applications). The presentation concludes by asking if end users should trust results that depend on current covariance data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

IER-517: Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK)

Nuclear criticality experiments are essential to the validation of nuclear data used in simulation software. The quality of nuclear data becomes paramount as simulation software becomes more relied upon for criticality safety studies and designs of nuclear systems. To improve the quality of nuclear data, experimenters can design critical experiments that are sensitive to isotope reaction pairs in materials of interest. The efforts conducted by the Organisation for Economic Co-operation and Development - Nuclear Energy Agency (OECD-NEA) Working Party on Nuclear Criticality Safety (WPNCS) Subgroup 8: Preservation of Expert Knowledge and Judgement Applied to Criticality Benchmarks (SG8) to categorize benchmarks according to their usefulness for nuclear data validation have been of great importance. Based on the OECD studies benchmark experiments included in the International Criticality Safety Benchmark Evaluation Project (ICSBEP) Handbook are concisely used by nuclear data evaluators, criticality safety engineers and others to validate nuclear data and simulation results. A lack of benchmarks sensitive to molybdenum in the (ICSBEP), particularly in the intermediate range, was noted by Los Alamos National Laboratory (LANL), the French Institut de Radioprotection et de Sûreté Nucléaire (IRSN), and Y-12 National Security Site prompting them to submit a joint integral experiment request to the Nuclear Criticality Safety Program (NCSP) in 2019. The request included both HEU and Plutonium systems in order to validate differential nuclear data focusing on the intermediate energy range but also includes thermal and fast configurations. This document represents the preliminary design work for a series of molybdenum integral experiments known as Molybdenum Optimized Benchmark System Demonstrating Integral Correlations (MOBY DICK).

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

CatMass : software for calculating optimal sample masses for X-ray absorption spectroscopy experiments involving complex sample compositions

This paper presents software for calculating the optimal mass of samples with complex compositions ( e.g. supported metal catalysts) for X-ray absorption spectroscopy (XAS) and scattering measurements. The ability to calculate the sample mass and other relevant parameters needed for an XAS measurement allows experimentalists to be better prepared in terms of detector selection, energy range of scan and overall time needed to complete the measurement, thus increasing efficiency. CatMass builds on existing sample mass calculators allowing users to determine the optimum sample preparation, collection geometry, usable energy range for a scan and approximate edge step of the absorption event. Visualization tools present the absorption calculation results in a format familiar to XAS experimentalists, with the added ability to save calculations and plots for future reference or recalculation. CatMass is a program broadly applicable in catalysis and is helpful for users with complex samples due to composition/stoichiometry or multiple competing elements.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Evaluating pulse-shaping capabilities of next-generation pulsed power architectures

This project evaluated the pulse shaping capabilities of next-generation pulsed power (NGPP) architectures. NGPP architectures share several common attributes including multiple independent pulse-generation lines, a radial water-insulated impedance transformer, and a central vacuum insulated load region. A multi-module circuit model was developed, incorporating independent pulse-generation lines and a 2-D transmission line mesh of the radial impedance transformer to assess the effects of azimuthal asymmetry in pulse-shaped experiments. Circuit model simulations demonstrated that NGPP architectures are able to produce the the desired current pulse shapes for exemplar NGPP experiments. Additionally, the project explored automated methods for experiment design, including derivative -ree optimization and machine learning. Pulse-shaped experiments require designers to determine machine parameters that reliably produce the desired current pulse at the load, a process that typically relies on expert knowledge and iterative adjustments using the Z circuit model. Given the increased complexity of NGPP systems, this manual approach may be impractical. While the evaluated methods do not eliminate the need for manual iteration, they can reduce the time required for experiment design. Derivative-free optimization automates much of the trial-and-error process, providing a close starting point for manual adjustments or making small modifications to near-final designs. Meanwhile, deep neural network methods can generate a good qualitative match to the desired current pulse in under one second without requiring circuit model simulations.

42 ENGINEERING↗

Optimizing the accuracy of viscoelastic characterization with AFM force–distance experiments in the time and frequency domains

Atomic Force Microscopy (AFM) force-distance (FD) experiments have emerged as an attractive alternative to traditional micro-rheology measurement techniques owing to their versatility of use in materials of a wide range of mechanical properties. Here, we show that the range of time dependent behaviour which can reliably be resolved from the typical method of FD inversion (fitting constitutive FD relations to FD data) is inherently restricted by the experimental parameters: sampling frequency, experiment length, and strain rate. Specifically, we demonstrate that violating these restrictions can result in errors in the values of the parameters of the complex modulus. In the case of complex materials, such as cells, whose behaviour is not specifically understood a priori, the physical sensibility of these parameters cannot be assessed and may lead to falsely attributing a physical phenomenon to an artifact of the violation of these restrictions. We use arguments from information theory to understand the nature of these inconsistencies as well as devise limits on the range of mechanical parameters which can be reliably obtained from FD experiments. The results further demonstrate that the nature of these restrictions depends on the domain (time or frequency) used in the inversion process, with the time domain being far more restrictive than the frequency domain. Lastly, we demonstrate how to use these restrictions to better design FD experiments to target specific timescales of a material's behaviour through our analysis of a polydimethylsiloxane (PDMS) polymer sample.

information theory↗

Leveraging design of experiments to build chemometric models for the quantification of uranium (VI) and HNO3 by Raman spectroscopy

Partial least squares regression (PLSR) and support vector regression (SVR) models were optimized for the quantification of U(VI) (10–320 g L −1 ) and HNO 3 (0.6–6 M) by Raman spectroscopy with optimized calibration sets chosen by optimal design of experiments. The designed approach effectively minimized the number of samples in the calibration set for PLSR and SVR by selecting sample concentrations with a quadratic process model, despite complex confounding and covarying spectral features in the spectra. The top PLS2 model resulted in percent root mean square errors of prediction for U(VI), HNO 3 , and NO 3 − of 3.7%, 3.6%, and 2.9%, respectively. PLS1 models performed similarly despite modeling an analyte with a majority linear response (i.e., uranyl symmetric stretch) and another with more covarying vibrational modes (i.e., HNO 3 ). Partial least squares (PLS) model loadings and regression coefficients were evaluated to better understand the relationship between weaker Raman bands and covarying spectral features. Support vector machine models outperformed PLS1 models, resulting in percent root mean square error of prediction values for U(VI) and HNO 3 of 1.5% and 3.1%, respectively. The optimal nonlinear SVR model was trained using a similar number of samples (11) compared with the PLSR model, even though PLS is a linear modeling approach. The generic D-optimal design presented in this work provides a robust statistical framework for selecting training set samples in disparate two-factor systems. This approach reinforces Raman spectroscopy for the quantification of species relevant to the nuclear fuel cycle and provides a robust chemometric modeling approach to bolster online monitoring in challenging process environments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Integrated edge-to-exascale workflow for real-time steering in neutron scattering experiments

We introduce a computational framework that integrates artificial intelligence (AI), machine learning, and high-performance computing to enable real-time steering of neutron scattering experiments using an edge-to-exascale workflow. Focusing on time-of-flight neutron event data at the Spallation Neutron Source, our approach combines temporal processing of four-dimensional neutron event data with predictive modeling for multidimensional crystallography. At the core of this workflow is the Temporal Fusion Transformer model, which provides voxel-level precision in predicting 3D neutron scattering patterns. The system incorporates edge computing for rapid data preprocessing and exascale computing via the Frontier supercomputer for large-scale AI model training, enabling adaptive, data-driven decisions during experiments. This framework optimizes neutron beam time, improves experimental accuracy, and lays the foundation for automation in neutron scattering. Although real-time experiment steering is still in the proof-of-concept stage, the demonstrated potential of this system offers a substantial reduction in data processing time from hours to minutes via distributed training, and significant improvements in model accuracy, setting the stage for widespread adoption across neutron scattering facilities and more efficient exploration of complex material systems.

97 MATHEMATICS AND COMPUTING↗