Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise Test”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Flight test results of the strapdown ring laser gyro tetrad inertial navigation system

A helicopter flight test program undertaken to evaluate the performance of Tetrad (a strap down, laser gyro, inertial navigation system) is described. The results of 34 flights show a mean final navigational velocity error of 5.06 knots, with a standard deviation of 3.84 knots; a corresponding mean final position error of 2.66 n. mi., with a standard deviation of 1.48 n. mi.; and a modeled mean position error growth rate for the 34 tests of 1.96 knots, with a standard deviation of 1.09 knots. No laser gyro or accelerometer failures were detected during the flight tests. Off line parity residual studies used simulated failures with the prerecorded flight test and laboratory test data. The airborne Tetrad system's failure--detection logic, exercised during the tests, successfully demonstrated the detection of simulated ""hard'' failures and the system's ability to continue successfully to navigate by removing the simulated faulted sensor from the computations. Tetrad's four ring laser gyros provided reliable and accurate angular rate sensing during the 4 yr of the test program, and no sensor failures were detected during the evaluation of free inertial navigation performance.

Carestia, R. A.↗

PNNL Measurement Results for the 2018 FlatTop Criticality Nuclear Accident Dosimetry Exercise at the Nevada National Security Site (IER-253)

The Pacific Northwest National Laboratory (PNNL) participated in the FlatTop exercise IER-253 at the National Nuclear Security Site (NNSS) during the week of May 21, 2018. This report summarizes the measurements of the personal nuclear accident dosimeters (PNAD). Additionally, portable survey instrument readings and measurements of the simulated biological samples are included. The FlatTop exercise (IER-253) tested only PNADs and did not include fixed nuclear accident dosimeters (FNAD). Previous PNAD results obtained in 2016 at the Godiva-IV exercise IER-148 were summarized in PNNL Measurement Results for the 2016 Criticality Accident Dosimetry Exercise at the Nevada National Security Site IER-148 (PNNL-26497). The results clearly indicated that the previous dose conversions were a historical legacy of the Hanford Site and corresponded closer to kerma dose (or first collision dose, and not to Hp(10) dose). The technical basis for PNAD dose was based on the Godiva-IV exercise and documented in A New Dose Calculation Methodology for New PNAD and FNAD Designs at PNNL (PNNL-27023). The configuration of the PNAD was described in these two documents. The FlatTop exercise was the first time PNNL tested this new dose calculation methodology. Results were generally favorable with some results conservatively over reported that fell above the performance criteria. The reported gamma dose results fell non-conservatively low because only the default parameters obtained from the Godiva-IV exercise were used, and because the OSL gamma dosimeter has an energy dependency. The results from the simulated biological samples were also favorable, and in several cases conservatively over reported.

61 RADIATION PROTECTION AND DOSIMETRY↗

Surface Operations: Two Case Studies of Simulated Lunar Operations

In September 2007, a team of scientists and engineers from several NASA centers participated in a field exercise at Meteor Crater, Arizona. The tests in this field exercise utilized recently developed robots of varying scales and capabilities and humans in pressurized space suits. Two examples of operations performed in the field are presented: a surface operations scenario involving suited crew supported by a number of mobile robots and setup operations for accessing a crater. The surface operations scenario simulated the end of a crew sortie and involved the following agents: 1) Suit subjects from Johnson Space Center s (JSC) advanced spacesuit laboratory 2) JSC's unpressurized crewed rover testbed, SCOUT 3) The Jet Propulsion Laboratory s (JPL) rough terrain, payload carrying robot, ATHLETE 4) JSC's Astronaut assist robot, Robonaut 5) Ames Research Center's (ARC) inspection robot, K-10. Operations began with ATHLETE positioning a pressurized rover compartment (PRC) as two crew members drove the SCOUT unpressurized rover from the field. The crew dismounted SCOUT, walked to the PRC for recharging. Robonaut then removed a sample box from the SCOUT equipment tray. K-10 then performed a drive around inspection of SCOUT, assembling a mosaic image. Lastly, the SCOUT vehicle was remotely driven to the next site. The setup operations for crater access scenario involved ATHLETE and Robonaut. This scenario began with Robonaut approaching ATHLETE and extracting a tether line. ATHLETE then extracted a drill and drilled an anchor into the surface. Robonaut then reconnected the tether to the anchor and backed away. ATHLETE is then ready to descend into the crater. This descending into the crater step is currently in the planning phase.

Bluethmann, William J.↗

Benefits, Consequences, and Uncertainties of Conventional (Exercise) Countermeasure Approaches

This presentation will review the pros, cons, and uncertainties of using exercise countermeasures in hypothetical long duration exploration missions. The use of artificial gravity and exercise will be briefly discussed. One benefit to continued use of exercise is related to our extensive experience with spaceflight exercise hardware and programming. Exercise has been a part of each space mission dating back to the 1960's when simple isometric and bungee exercises were performed in the Gemini capsule. Over the next 50 years, exercise hardware improved cumulating in today's ISS suite of exercise equipment: Cycle Ergometer with Vibration Isolation and Stabilization System (CEVIS), Treadmill (T2) and Advanced Resistive Exercise Device (ARED). Today's exercise equipment is the most robust ever to be flown in space and allows the variety and intensity of exercise that might reasonably be expected to maintain muscle mass and function, bone density and cardiovascular fitness. A second benefit is related to the large body of research literature on exercise training. There is a considerable body of supporting research literature including >40,000 peer reviewed research articles on exercise training in humans. A third benefit of exercise is its effectiveness. With the addition of T2 and ARED to our ISS exercise suite, crew member outcomes on standard medical tests have improved. Additionally exercise has other positive side effects such as stress relief, possible improvement of immune function, improved sleep, etc. Exercise is not without its consequences. The major cons to performance of in‐flight exercise are the time and equipment required. Currently crew are scheduled 2.5 hrs/day for exercise and there is considerable cost to develop, fly and maintain exercise hardware. While no major injuries have been reported on ISS, there is always some risk of injury with any form of exercise There are several uncertainties going forward; these relate mostly to the development of small compact robust effective exercise devices for the next generation of space vehicles. It is becoming increasingly apparent that high intensity exercise is required for maintenance of fitness and functional capability and so future hardware will need to be developed, tested and implemented that allow for a wide variety of exercise, at high intensity while likely involving low mass, volume and power. There are many unanswered issues related to the minimum number and type of exercise devices required for exploration, optimizing exercise prescriptions for these devices, whether a treadmill is absolutely required, and even whether any single countermeasure can adequately protect muscle, bone, cardiovascular and sensorimotor function.

Ploutz-Snyder, Lori↗

Time-to-Fatigue and Intramuscular pH Measured via NIRS During Handgrip Exercise in Trained and Sedentary Individuals

In exercising muscles force production and muscular endurance are impaired by a decrease in intramuscular pH. The effects of aerobic training (AT) on preventing acidosis and prolonging exercise time in muscles not specifically targeted by the training are unknown. Purpose: To compare interstitial pH, measured non-invasively with near infrared spectroscopy (NIRS), in the flexor digitorum profundus (FDP) during rhythmic handgrip exercise in sedentary subjects and those who participate in AT activities that target the lower body. Methods: Maximal isometric force (MIF) was measured on three separate days in AT (n=5) and sedentary (n=8) subjects using a handgrip dynamometer (HGD). Isometric muscular endurance (IME) was measured during five trials, each separated by at least 48 hrs. For each IME trial subjects rhythmically squeezed (4 sec at 40% of MVC) and relaxed (2 sec) to fatigue or failure to reach the target force in three consecutive contractions or four non-consecutive contractions. Interstitial pH was derived from spectra collected using a NIRS sensor adhered to the skin over the FDP. The first four IME trials served to familiarize subjects with the protocol; the fifth trial was used for analysis. NIRS-derived pH was averaged in 30 sec increments. Between group differences in MIF and exercise time were tested using paired t-tests. A repeated measures ANOVA was used to analyze effects of AT and exercise time on pH. Results: MIF was not different between groups (mean SD; aerobic=415.6 95.4 N vs. sedentary =505.1 107.4 N). Time to fatigue was greater in the AT than in the sedentary group (mean SD: 611 173 sec vs. 377 162 sec, p<0.05). pH was not different between groups at any time point. Average pH decreased (p<0.05) in both groups from rest (pH=7.4) through 90 sec of exercise (pH=6.9), but did not decrease further throughout the remainder of exercise. Conclusion: Although between group differences in pH were not detected, differences during the onset of exercise may exist with a more frequent sampling. AT individuals appear to better tolerate decreased interstitial pH and are able to continue submaximal muscular work, possibly due to psychological familiarization to muscular fatigue and/or systemic physiological benefits.

Everett, M. E.↗

Long Duration Exposure Facility (LDEF) low temperature Heat Pipe Experiment Package (HEPP) flight results

The Low Temperature Heat Pipe Flight Experiment (HEPP) is a fairly complicated thermal control experiment that was designed to evaluate the performance of two different low temperature ethane heat pipes and a low-temperature (182 K) phase change material. A total of 390 days of continuous operation with an axially grooved aluminum fixed conductance heat pipe and an axially grooved stainless steel heat pipe diode was demonstrated before the data acquisition system's batteries lost power. Each heat pipe had approximately 1 watt applied throughout this period. The HEPP was not able to cool below 188.6 K during the mission. As a result, the preprogrammed transport test sequence which initiates when the PCM temperature drops below 180 K was never exercised, and transport tests with both pipes and the diode reverse mode test could not be run in flight. Also, because the melt temperature of the n-heptane PCM is 182 K, its freeze/thaw behavior could not be tested. Post-flight thermal vacuum tests and thermal analyses have indicated that there was an apparent error in the original thermal analyses that led to this unfortunate result. Post-flight tests have demonstrated that the performance of both heat pipes and the PCM has not changed since being fabricated more than 14 years ago. A summary of HEPP's flight data and post-flight test results are presented.

Mcintosh, Roy↗

Maximum Oxygen Uptake During and After Long-Duration Space Flight

Decreased maximum oxygen consumption (VO2max) during and after space flight may impair a crewmember s ability to perform mission-critical work that is high intensity and/or long duration in nature (Human Research Program Integrated Research Plan Risk 2.1.2: Risk of Reduced Physical Performance Capabilities Due to Reduced Aerobic Capacity). When VO2max was measured in Space Shuttle experiments, investigators reported that it did not change during short-duration space flight but decreased immediately after flight. Similar conclusions, based on the heart rate (HR) response of Skylab crewmembers, were made previously concerning long-duration space flight. Specifically, no change in the in-flight exercise HR response in 8 of 9 Skylab crewmembers indicated that VO2max was maintained during flight, but the elevated exercise HR after flight indicated that VO2max was decreased after landing. More recently, a different pattern of in-flight exercise HR response, and assumed changes in VO2max, emerged from routine testing of International Space Station (ISS) crewmembers. Most ISS crewmembers experience an elevated in-flight exercise HR response early in their mission, with a gradual return toward preflight levels as the mission progresses. Similar to previous reports, exercise HR is elevated after ISS missions and returns to preflight levels by 30 days after landing. VO2max has not been measured either during or after long-duration space flight. The purposes of the ISS VO2max experiment are (1) to measure VO2max during and after long-duration spaceflight, and (2) to determine if submaximal exercise test results can be used to accurately estimate VO 2max.

Moore, Alan D., Jr.↗

Geolab in NASA's First Generation Pressurized Excursion Module: Operational Concepts

We are building a prototype laboratory for preliminary examination of geological samples to be integrated into a first generation Habitat Demonstration Unit-1/Pressurized Excursion Module (HDU1-PEM) in 2010. The laboratory GeoLab will be equipped with a glovebox for handling samples, and a suite of instruments for collecting preliminary data to help characterize those samples. The GeoLab and the HDU1-PEM will be tested for the first time as part of the 2010 Desert Research and Technology Studies (DRATS), NASAs annual field exercise designed to test analog mission technologies. The HDU1-PEM and GeoLab will participate in joint operations in northern Arizona with two Lunar Electric Rovers (LER) and the DRATS science team. Historically, science participation in DRATS exercises has supported the technology demonstrations with geological traverse activities that are consistent with preliminary concepts for lunar surface science Extravehicular Activities (EVAs). Next years HDU1-PEM demonstration is a starting point to guide the development of requirements for the Lunar Surface Systems Program and test initial operational concepts for an early lunar excursion habitat that would follow geological traverses along with the LER. For the GeoLab, these objectives are specifically applied to enable future geological surface science activities. The goal of our GeoLab is to enhance geological science returns with the infrastructure that supports preliminary examination, early analytical characterization of key samples, insight into special considerations for curation, and data for prioritization of lunar samples for return to Earth.

Evans, C. A.↗

Validation of the Pulmonary Function System for Use on the International Space Station

Aerobic deconditioning occurs during long duration space flight despite the use of exercise countermeasures (Convertino, 1996). As a part of International Space Station (ISS) medical operations, periodic tests designed to estimate aerobic capacity are performed to track changes in aerobic fitness and to determine the effectiveness of exercise countermeasures. These tests are performed prior to, during, and after missions of greater than 30 days in duration. Crewmembers selected for missions aboard the ISS perform a graded exercise test on a cycle ergometer approximately 270 days prior to their scheduled launch date in order to measure peak oxygen consumption (VO2PK) and peak heart rate (HRpk). Approximately 30 to 45 days prior to launch, crewmembers perform a submaximal cycle ergometer test at work rates set to elicit 25, 50 and 75% of their pre-flight VO2PK. This test, known as the Periodic Fitness Evaluation (PFE), serves as a baseline measure to which subsequent in-and post-flight exercise tests are compared. While onboard the ISS, crewmembers are normally scheduled to perform the PFE beginning with flight day (FD) 14 and every 30 days thereafter. The PFE is also conducted 5 and 30 days following flight. Using PFE data, aerobic fitness is estimated by quantifying the VO2 vs. HR relationship using linear regression and calculating the VO2 that would occur at the crewmember s previously measured HRpk. Currently, for data collected during flight, this technique assumes that the pre- vs. in-flight oxygen consumption per given cycle workload is similar. However, the validity of this assumption is based upon a sparse amount of data collected during the Skylab era (Michel, et al. 1977). The method of using heart rate and cycle ergometer work rates has been used to estimate aerobic fitness in normal gravity (Astrand and Ryhming, 1954; Lee, 1993). Due to spaceflight induced physiological alterations, such as shifts in extracellular fluid (e.g. plasma) volume, this method may not be valid during space flight. In addition, the ergometer onboard ISS is vibration-isolated and moves with the astronaut s application of force into the pedals. The effect of this movement on the VO2 of cycle exercise on ISS has not been quantified.

McCleary, Frank A.↗

National Campaign Development Test Executive Summary

NASA’s vision for Advanced Air Mobility (AAM) is to provide safe, sustainable, accessible, and affordable aviation for transformational local and intraregional missions and includes the transportation of passengers and cargo as well as aerial work missions, such as infrastructure inspection or search and rescue operations. NASA’s technical expertise, intergovernmental relationships, and high level of public trust will help this technology come to market concurrent with infrastructure readiness, public acceptance, and constructive regulation. By advising and integrating disparate AAM efforts across the country and working collaboratively with the FAA, the National Campaign (NC) objective is to motivate industry progress and support the development of policy, regulatory, and technical standards in a manner that best ensures public safety and benefit to the American people. NC began with the Dry Run and Developmental Test (NC-DT), which served as a pathfinder for collaboration and direct involvement with industry partners in integrated simulation exercises and flight tests. NC-DT culminated with an acoustics-gathering flight test in September 2021 with industry partner Joby’s prototype S4 2.0 air vehicle, which delivered the first foundational baseline of noise levels present in Electric Vertical Takeoff and Landing (eVTOL) vehicles. Through the DT phase, the NC team built and tested the airspace and range infrastructure while assessing the readiness level of industry partners leading up to future NC events. The purpose of this paper is to provide an overview of NC-DT.

National Campaign↗

Reliability of the Danish Aerospace Corporation Portable Pulmonary Function System

Metabolic gas analysis is a critical component of investigations that measure cardio-pulmonary exercise responses during and after long-duration spaceflight. The primary purpose of the current study was to determine the reliability and intra-subject repeatability of a metabolic gas analysis device, the Portable Pulmonary Function System (PPFS), designed for use on the International Space Station (ISS). The second objective of this study was to directly compare PPFS measurements of expired oxygen and carbon dioxide (FEO2 and FECO2) to values obtained from a well-validated clinical metabolic gas analysis system (ParvoMedics TrueOne (c) [PM]). Eight subjects performed four peak cycle tests to maximal exertion. The first test was used to prescribe work rates for the subsequent test sessions. Metabolic gas analysis for this test was performed by the PM, but samples of FEO2 and FECO2 also were simultaneously collected for analysis by the PPFS. Subjects then performed three additional peak cycle tests, consisting of three 5-min stages designed to elicit 25%, 50%, and 75% maximal oxygen consumption (VO2max) followed by stepwise increases of 25 W/min until subjects reached volitional exhaustion. Metabolic gas analysis was performed using the PPFS for these tests. Intraclass correlation coefficients (ICC), within-subject standard deviations (WS SD), and coefficients of variation (CV%) were calculated for the repeated exercise tests. Mixed model regression analysis was used to compare paired FEO2 and FECO2 values obtained from the PPFS and the PM during the initial test. The ICC values for oxygen consumption (VO2), carbon dioxide production (VCO2), and ventilation (VE) indicate that the PPFS is highly reliable (0.79 to 0.99) for all exercise levels tested; however, ICCs for respiratory exchange ratio (RER) were low ( 0.11 - 0.51), indicating poor agreement between trials during submaximal and maximal exercise. Overall, CVs ranged from 1.6% to 6.7% for all measurements, a finding consistent with reported values that were obtained using other metabolic gas analysis techniques. The PPFS and PM produced comparable FEO2 data; however, there was less agreement between measures of FECO2 obtained from the two devices, particularly at lower CO2 concentrations. The PPFS appears, in practically all respects, to yield highly reliable metabolic gas analysis data. Lower reliability of RER measurements reported in the literature and likely is not a function of the PPFS device. Further examination of PPFS CO2 data is warranted to better understand the limitations of these PPFS measurements. Overall, the PPFS when used for repeated measures of cardio-pulmonary exercise should provide accurate and reliable data for studies of human adaptation to spaceflight.

Portable Pulmonary Function System (PPFS)↗

Potential benefits of maximal exercise just prior to return from weightlessness

The purpose of this study was to determine whether performance of a single maximal bout of exercise during weightlessness within hours of return to earth would enhance recovery of aerobic fitness and physical work capacities under a 1G environment. Ten healthy men were subjected to a 10-d bedrest period in the 6-deg headdown position. A graded maximal supine cycle ergometer test was performed before and at the end of bedrest to simulate exercise during weightlessness. Following 3 h of resumption of the upright posture, a second maximal exercise test was performed on a treadmill to measure work capacity under conditions of 1G. Compared to before bedrest, peak oxygen consumption, V(O2), decreased by 8.7 percent and peak heart rate (HR) increased by 5.6 percent in the supine cycle test at the end of bedrest. However, there were no significant changes in peak V(O2) and peak HR in the upright treadmill test following bedrest. These data suggest that one bout of maximal leg exercise prior to return from 10 d of weightlessness may be adequate to restore preflight aerobic fitness and physical work capacity.

Convertino, Victor A.↗

Logistics for the 2026 International Nuclear Accident Dosimetry Intercomparison Exercise

The purpose of this exercise is to test participants’ nuclear accident dosimeters (NADs) and personnel to the requirements established by American National Standards Institute (ANSI), Health Physics Society (HPS) standard ANSI/HPS-N13.3-2013 (R2025) Dosimetry for Criticality Accidents. IER-634 is the second nuclear accident dosimetry exercise taking place at the Armed Forces Radiobiology Research Institute (AFRRI) in Bethesda, MD, a Department of Defense (DOD) facility. This effort continues use of the high-dose neutron exposure test bed maintained by the DOD and represents the continued collaboration between the DOD and Department of Energy (DOE). Previous work at AFRRI included a reactor characterization (IER 484) in 2023 and a nuclear accident intercomparison exercise (IER-602) in 2024.

61 RADIATION PROTECTION AND DOSIMETRY↗

Preliminary Evaluation of National Campaign Scenarios for Urban Air Mobility

Urban Air Mobility and Advanced Air Mobility concepts offer a novel method for transportation of passengers and cargo. Whereas the concept may reduce congestion of roads and highways, it also introduces new complexity to the National Airspace in terms of management of such operations. NASA, in partnership with FAA and industry, approaches these complexities with research and development activities such as flight tests and simulations, in order to better understand the impacts and necessary mechanisms by which these operations could be integrated. One example of such research and development activity that NASA is conducting is the Advanced Air Mobility National Campaign effort. Flight-test scenarios were proposed as part of the National Campaign and tested in simulation for evaluation with industry partners prior to the Flight test. This simulation, exercised as an engineering evaluation, provided a data collection opportunity to better understand what iterations and modifications would be needed to successfully demonstrate the flight-test scenarios in order to mature the concept of Urban Air Mobility and Advanced Air Mobility.

urban air mobility↗

Preliminary Evaluation of National Campaign Scenarios for Urban Air Mobility

Urban Air Mobility and Advanced Air Mobility concepts offer a novel method for transportation of passengers and cargo. Whereas the concept may reduce congestion of roads and highways, it also introduces new complexity to the National Airspace in terms of management of such operations. NASA, in partnership with FAA and industry, approaches these complexities with research and development activities such as flight tests and simulations, in order to better understand the impacts and necessary mechanisms by which these operations could be integrated. One example of such research and development activity that NASA is conducting is the Advanced Air Mobility National Campaign effort. Flight-test scenarios were proposed as part of the National Campaign and tested in simulation for evaluation with industry partners prior to the Flight test. This simulation, exercised as an engineering evaluation, provided a data collection opportunity to better understand what iterations and modifications would be needed to successfully demonstrate the flight-test scenarios in order to mature the concept of Urban Air Mobility and Advanced Air Mobility.

Urban Air Mobility↗

Effect of Pharmacologically-Induced Hypovolemia on Aerobic Capacity

Decreased peak oxygen consumption (VO2pk) and an elevated exercise heart rate (HR) response are associated with a reduction in plasma volume (PV) after space flight and bed rest, a space flight analog. Reduced VO2pk and submaximal exercise tolerance would negatively impact an astronaut s ability to perform near maximal work that would be required in the event of an emergency. We previously have administered IV furosemide followed by a low salt diet to model PV loss and orthostatic intolerance observed after spaceflight. Purpose: To determine whether a pharmacologically-induced reduction in PV results in decreased VO2pk and elevated exercise HR response. Methods: Six subjects (5M, 1F) performed two graded peak cycle tests (work rate increased by 35 or 50 W every 3 min), once while normovolemic and once while hypovolemic. HR and expired respiratory gases were continuously measured. To induce hypovolemia, subjects were administered a single dose of IV furosemide (0.5 mg.kg-1) 30 hr before exercise testing and then consumed a low-salt diet (10 mEq.d(sup -1)). PV was measured using carbon monoxide rebreathing. Exercise HR and VO2 responses were quantified as the area under the curve (AUC) calculated over each quartile of the peak test, based on test time in the hypovolemia condition. Paired t-tests were used to test for differences in PV, VO2pk, and peak HR between conditions. Repeated-measures ANOVAs were used to test for differences in AUC between conditions. Results: PV (3.32+/-0.12 vs. 2.77+/-0.16 L, p<0.05) and VO2pk (3.30+/-0.67 vs. 2.90+/-0.57 L.min(sup -1), p<0.05) were lower during hypovolemia than during normovolemia, but peak HR was not different (187+/-5 vs. 187+/-5 bpm). The AUC for VO2 and HR was different (p<0.05) between conditions only in the highest quartile: HR was 4% higher and VO2 was 5% lower during the hypovolemia condition. Conclusion: The mean difference in VO2pk (-12%) between normovolemia and hypovolemia was similar to the mean difference in PV (-17%). Similar decreases in PV and VO2pk have been observed following short duration space flight, suggesting that pharmacologically-induced PV loss can be used to model microgravity-induced reductions in VO2pk.

Everett, Meghan E.↗

In-Flight Evaluation of the Traffic Aware Planner on the NASA HU-25A Guardian Aircraft

NASA’s Traffic Aware Planner (TAP) software is a research-prototype decision support tool that provides pilots with time- and fuel-saving route recommendations that optimize their current trajectory. The software runs on a first-of-a-kind system architecture onboard three aircraft in revenue service conducting operational evaluations with a major domestic airline. Therefore, significant NASA-internal testing is required prior to releasing the software to the partner airline. This paper describes a flight test plan that exercises the functionality of the TAP software in a representative operational environment, describes the system architecture developed and implemented for the NASA Langley HU-25A Guardian aircraft to support the test objectives, presents outcomes of the flight test campaign, and discusses use cases that demonstrate the value of flight testing for this activity.Research into flight path optimization of transport aircraft conducted by the National Aeronautics and SpaceAdministration (NASA) has produced an operational concept known as Traffic Aware Strategic Aircrew Requests(TASAR) [1, 2]. This near-term concept [3] provides the aircrew with a flight deck decision support tool known asthe Traffic Aware Planner (TAP). The TAP software leverages a growing number of information sources on the flightdeck to make time- and fuel-saving route optimization recommendations to the aircrew while en route. The aircrewcan then use the suggestions provided by the tool to make route change requests with a greater likelihood of acceptanceby air traffic control (ATC). Since TASAR is a concept intended for the current operational environment, it isintentionally designed to have no safety-critical impact or require any changes to current Federal AviationAdministration (FAA) rules and procedures [4, 5].The research prototype TAP system [6–8], explained further in Section III.C, continually incorporates up-to-dateaircraft state data from onboard avionics, as well as the latest position of surrounding traffic, the most recent windforecast, and the most recent convective weather forecast, in order to calculate candidate trajectory modifications thatimprove upon the current active route. These trajectories account for user-selectable objective functions [3] of reducedfuel burn, reduced flight time, or an airline-derived combination of factors known as trip cost. Previous analyses andsimulations have estimated substantial savings for airlines employing this technique within the U.S. National AirspaceSystem (NAS) [9–11]. Operational evaluations with Alaska Airlines seek to validate these projected benefits usingmeasured data while simultaneously providing benefits to the airline [12, 13].The TAP software has undergone a number of human-in-the-loop simulations [14] and flight test activities[15–17] in order to validate the operational concept, evaluate human factors considerations (e.g., workload, usability,distraction, etc.), and to assess the ability of the software to function in a representative operational environment (e.g.,connected to live avionics data, using in-flight internet connectivity, etc.). However, these simulations and flight testcampaigns did not account for the hardware architecture implemented on the three aircraft for Alaska Airlines’operational evaluations of the TAP software. Therefore, a need was identified to thoroughly test the functionality ofthe software in a similar hardware architecture to that of the partner airline’s aircraft. Information regarding testapparatus and environments used to evaluate TAP prior to testing on the HU-25A can be found in reference [18].A campaign of flight trials on a NASA aircraft, the HU-25A Guardian, was conducted to ensure that the researchprototype TAP system functions well in a configuration similar to the Alaska Airlines aircraft prior to deployment.This airborne, networked environment enables an assessment of the operational factors unique to the flight environment. Additionally, this activity evaluated the effectiveness and benefit of new TAP functionality andoperation in a relevant flight environment while allowing the rapid prototyping of new concepts and features.This paper is organized as follows: Section II discusses the details of the flight test plan, flight profiles, and theduties of personnel involved with conducting flight operations. Section III describes the test platform, avionicsequipage, and system architecture. Section IV presents a discussion of results, and Section V contains concludingremarks.

Underwood, Matthew C.↗

NASA's Desert RATS Science Backroom: Remotely Supporting Planetary Exploration

NASA's Desert Research and Technology Studies (Desert RATS) is a multi-year series of tests designed to exercise planetary surface hardware and operations in conditions where long-distance, multi-day roving is achievable. In recent years, a D-RATS science backroom has conducted science operations and tested specific operational approaches. Approaches from the Apollo, Mars Exploration Rovers and Phoenix missions were merged to become the baseline for these tests. In 2010, six days of lunar-analog traverse operations were conducted during each week of the 2-week test, with three traverse days each week conducted with voice and data communications continuously available, and three traverse days conducted with only two 1-hour communications periods per day. In 2011, a variety of exploration science scenarios that tested operations for a near-earth asteroid using several small exploration vehicles and a single habitat. Communications between the ground and the crew in the field used a 50-second one-way delay, while communications between crewmembers in the exploration vehicles and the habitat were instantaneous. Within these frameworks, the team evaluated integrated science operations management using real-time science operations to oversee daily crew activities, and strategic level evaluations of science data and daily traverse results. Exploration scenarios for Mars may include architectural similarities such as crew in a habitat communicating with crew in a vehicle, but significantly more autonomy will have to be given to the crew rather than step-by-step interaction with a science backroom on Earth.

Cohen, Barbara A.↗