Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Exercise”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

IER 538: International Dosimetry Intercomparison Exercise with Godiva-IV [Slides]

Presentation on International Dosimetry Intercomparison Exercise with Godiva-IV. This presentation details Department of Energy (DOE) requirements and irradiation. Graphs show Neutron dose conversion factors, Neutron dose characterization, and Photon dose characterization. Results of 2m, 3m, and 4m tests are then compared to DOE standards. Findings show photon dose measurements were limited by instrumentation not available. Additionally, there has been a turnover of staff in dosimetry. However, funding is being provided for Universal Nuclear Accident Dosimeter (U-NAD).

61 RADIATION PROTECTION AND DOSIMETRY↗

Homogeneity, Heterogeneity and Uncertainty in Epic Shadow exercises [Slides]

High precision analyses demonstrate the ability to measure very small differences between sample aliquots. Is it appropriate for us to assume a homogenous sample in ES exercises? When running aliquots in triplicate should the data be averaged? If averaged what uncertainty should be applied, and what does the uncertainty describe? What is the most appropriate uncertainty to apply on single measurements?

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Deployment Equipment Exercises for NMV UVT Visit

In this exercise, you will use the Insta360 X3 action cameras to capture mock inspection footage and review the footage to identify objects that were hidden in the facility.

47 OTHER INSTRUMENTATION↗

Building Cybersecurity Educational Materials for Students: The Windfarm Capture-The-Flag Exercise

Securing and protecting critical infrastructure in an increasingly digital world is vital but it is all too often an afterthought. It is especially important that students become aware of internet safety and security at an early age. However, the availability of interactive and educational cybersecurity material targeted toward students is minimal in the United States. Here we show an example of interactive cyber security educational material that an educator can use in their classroom to encourage students to think about the interaction between real-world physical objects, cyber security, and information security. By putting together a “capture-the-flag” exercise, students can see in real time how hackers and cybercriminals exploit vulnerabilities and gain access information. The students try to “capture” the “flag” (i.e., information) in the wind farm by looking for oddities in the code or by taking advantage of weaknesses in everyday protocols. Students can also see how cybersecurity interacts with the power grid through the wind farm project scenario and how a hacker could cause serious problems to a critical infrastructure sector. Our goal for the project is getting students interested in cybersecurity and help them develop an awareness of how important having robust security systems is. We also hope that this project demonstrates the importance of introducing these concepts early and inspires others to create similar projects geared toward students.

97 MATHEMATICS AND COMPUTING↗

Strategic National Level Exercises Program White Paper - Draft

The general objective of this white paper is to share lessons learned and provide interdisciplinary recommendations on how to use NLE to evaluate, assess and improve national nuclear security regimes. The specific objectives of this white paper are: — To describe the type of exercises, benefits and requirements — To outline the different capacity areas and capability performance levels — To provide concrete and actionable recommendations to INS’s partners on how to use NLE to improve national nuclear security regimes.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Integrated Modeling, Mapping, and Simulation (IMMS) framework for planning exercises.

The Integrated Modeling, Mapping, and Simulation (IMMS) program is designing and prototyping a simulation and collaboration environment for linking together existing and future modeling and simulation tools to enable analysts, emergency planners, and incident managers to more effectively, economically, and rapidly prepare, analyze, train, and respond to real or potential incidents. When complete, the IMMS program will demonstrate an integrated modeling and simulation capability that supports emergency managers and responders with (1) conducting 'what-if' analyses and exercises to address preparedness, analysis, training, operations, and lessons learned, and (2) effectively, economically, and rapidly verifying response tactics, plans and procedures.

99 GENERAL AND MISCELLANEOUS↗

Web-based emergency response exercise management systems and methods thereof

According to one embodiment, a method for simulating portions of an emergency response exercise includes generating situational awareness outputs associated with a simulated emergency and sending the situational awareness outputs to a plurality of output devices. Also, the method includes outputting to a user device a plurality of decisions associated with the situational awareness outputs at a decision point, receiving a selection of one of the decisions from the user device, generating new situational awareness outputs based on the selected decision, and repeating the sending, outputting and receiving steps based on the new situational awareness outputs. Other methods, systems, and computer program products are included according to other embodiments of the invention.

99 GENERAL AND MISCELLANEOUS↗

Whole core analysis of OECD/NEA TVA-WB1 benchmark exercise 1 using continuous-energy Monte Carlo code MVP with JENDL-4.0u and ENDF/B-VII.0

The TVA WB1 benchmark problem was precisely modeled in accordance with the geometry and material specifications, and benchmark exercise 1 was solved with the MVP code and the nuclear data libraries based on JENDL-4.0u (JENDL-4.0 updated file) and ENDF/B-VII.0. The criticality, the control rod bank worth, the isothermal temperature coefficient (ITC), the integral rod worth of bank D, and differential soluble boron worth (DBW) were obtained. The criticality and the control rod bank worth were compared with the measured data and published calculation results with other codes, Serpent and KENO. The criticality and the control rod bank worth calculated by MVP and the libraries agree with the measured and the published calculation results within the criteria specified in the ANSI/ANS standard. From these results, the calculation model for the MVP and the libraries was verified. The other parameters such as ITC, the integral rod worth, and DBW were also compared between JENDL-4.0u and ENDF/B-VII.0. The comparison of the results shows JENDL-4.0u and ENDF/B-VII.0 give comparable results within the standard deviation, the difference between libraries is small. (author)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

IAEA Coordinated Research Project on Master Curve Approach to Monitor Fracture Toughness of RPV Steels: Final Results of the Experimental Exercise to Support Constraint Effects

The precracked Charpy single-edge notched bend, SE(B), specimen (PCC) is the most likely specimen type to be used for determination of the reference temperature, T0, with reactor pressure vessel (RPV) surveillance specimens. Unfortunately, for many RPV steels, significant differences have been observed between the T0 temperature for the PCC specimen and that obtained from the 25-mm thick compact specimen [1TC(T)], generally considered the standard reference specimen for T0. This difference in T0 has often been designated a specimen bias effect, and the primary focus for explaining this effect is loss of constraint in the PCC specimen. The International Atomic Energy Agency (IAEA) has developed a coordinated research project (CRP) to evaluate various issues associated with the fracture toughness Master Curve for application to light-water RPVs. Topic Area 1 of the CRP is focused on the issue of test specimen geometry effects, with emphasis on determination of T0 with the PCC specimen and the bias effect. Topic Area 1 has an experimental part and an analytical part. Participating organizations for the experimental part of the CRP performed fracture toughness testing of various steels, including the reference steel JRQ (A533-B-1) often used for IAEA studies, with various types of specimens under various conditions. Additionally, many of the participants took part in a round robin exercise on finite element modeling of the PCVN specimen, discussed in a separate paper. Results from fracture toughness tests are compared with regard to effects of specimen size and type on the reference temperature T0. It is apparent from the results presented that the bias observed between the PCC specimen and larger specimens for Plate JRQ is not nearly as large as that obtained for Plate 13B (-11 C vs -37 C) and for some of the results in the literature (bias values as much as -45 C). This observation is consistent with observations in the literature that show significant variations in the bias that are dependent on the specific materials being tested. There are various methods for constraint adjustments and two methods were used that reduced the bias for Plate 13B from -37 C to -13 C in one case and to -11 C in the second case. Unfortunately, there is not a consensus methodology available that accounts for the differences observed with different materials. Increasing the Mlim value in the ASTM E-1921 to ensure no loss of constraint for the PCC specimen is not a practicable solution because the PCC specimen is derived from CVN specimens in RPV surveillance capsules and larger specimens are normally not available. Resolution of these differences are needed for application of the master curve procedure to operating RPVs, but the research needed for such resolution is beyond the scope of this CRP.

36 MATERIALS SCIENCE↗

Lidar Inter-Comparison Exercise Final Campaign Report

The objective of this IOP was to evaluate the performances of the new Leosphere R-MAN 510 lidar procured by the Australian Bureau of Meteorology, by testing it against the MPL and Raman lidars at the Darwin ARM site. This lidar is an eye-safe (355 nm), turn-key mini Raman lidar, which allows for the detection of aerosols and cloud properties, and the retrieval of particulate extinction profiles. To do so, the R-MAN 510 lidar has been operated at the Darwin ARM site, next to the MPL, Raman lidar, and Vaisala ceilometer for three months (from 20 January 2013 to 20 April 2013) in order to collect a good sample for statistical comparisons. The comparisons with the Raman lidar were not performed, since the Raman lidar attenuated backscatter and depolarization ratio product was not available. A new product has just been delivered to the ARM archive as a value-added product, hence this study will continue. Nevertheless we have developed software to match the different space and time resolutions of the other lidars and project the data onto a common grid to permit detailed comparison of the instruments’ performance and an enhanced analysis of clouds and aerosols through the use of composite data products, like the ratios of attenuated backscatters, attenuated scattering ratios and depolarization ratios. Comparisons between the MPL and R-MAN510 lidar data exhibit large differences in total attenuated backscatter at 355 and 532 nm, attenuated scattering ratios, and aerosol volume depolarization ratios. Differences in attenuated backscatter result mainly from the different relative contributions of scattering from molecules and particles at the different wavelengths, but there are some intriguing differences that will require further investigations. The differences in volume depolarization ratios are due to the much larger contribution of molecular returns to the volume depolarization ratio (5 times larger at 355 nm than at 532 nm). The R-MAN510 lidar is also found to be much less sensitive to daylight solar background illumination, which is greater at the visible wavelength than in the UV.

54 ENVIRONMENTAL SCIENCES↗

The Table of Standard Atomic Weights—an exercise in consensus

The present Table of Standard Atomic Weights (TSAW) of the elements is perhaps one of the most familiar datasets in science. Unlike most parameters in physical science whose values and uncertainties are evaluated using the “Guidelines for Uncertainty in Measurement” (GUM), the majority of standard atomic-weight values and their uncertainties are consensus values, not GUM-evaluated values. The Commission on Isotopic Abundances and Atomic Weights of the International Union of Pure and Applied Chemistry (IUPAC) regularly evaluates the literature for new isotopic-abundance measurements that can lead to revised standard atomic-weight values, A r (E) for element E. The Commission strives to provide utmost clarity in products it disseminates, namely the TSAW and the Table of Isotopic Compositions of the Elements (TICE). In 2016, it was recognized by the Commission that a guideline recommending expression of uncertainty listed in parentheses following the standard atomic-weight value, e.g. A r (Se) = 78.971(8), is not in accord with the GUM, which suggests that this parenthetic notation be reserved to express standard uncertainty, not the expanded uncertainty used in the TSAW and TICE. In 2017, to eliminate this noncompliance with the GUM, a new format was adopted in which the uncertainty value is specified by the plus-minus symbol, e.g. A r (Se) = 78.971 ± 0.008. To clarify the definition of uncertainty, a new footnote has been added to the TSAW. This footnote emphasizes that an atomic-weight uncertainty is a consensus (decisional) uncertainty. Not only has the Commission shielded users of the TSAW and TICE from unreliable measurements that appear in the literature as a result of unduly small uncertainties, but the aim of IUPAC has been fulfilled by which any scientist, taking any natural sample from commerce or research, can expect their sample atomic weight to lie within A r (E) ± its uncertainty almost all of the time.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗