Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Equipment Design”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Investigation Into The Effects of Microsecond Power Line Transients On Line-Connected Capacitors

An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage rating needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

Javor, Ken↗

Investigation into the Effects of Microsecond Power Line Transients on Line-Connected Capacitors

An investigation was conducted into the effect of power-line transients on capacitors used by NASA and installed on platform primary power inputs to avionics. The purpose was to investigate whether capacitor voltage ratings needs to be derated for expected spike potentials. Concerns had been voiced in the past by NASA suppliers that MIL-STD-461 CS06-like requirements were overly harsh and led to physically large capacitors. The author had previously predicted that electrical-switching spike requirements representative of actual power-line transient potentials, durations. and source impedance would require no derating. This investigation bore out that prediction. It was further determined that traditional low source impedance CS06-like transients also will not damage a capacitor, although the spikes themselves are not nearly as well filtered. This report should be used to allay fears that CS06-like requirements drive capacitor voltage derating. Only that derating required by the relatively long duration transients in power quality specification need concern the equipment designer.

Javor, K.↗

Solid State Laser

The Titan-CW Ti:sapphire (titanium-doped sapphire) tunable laser is an innovation in solid-state laser technology jointly developed by the Research and Solid State Laser Divisions of Schwartz Electro-optics, Inc. (SEO). SEO is producing the laser for the commercial market, an outgrowth of a program sponsored by Langley Research Center to develop Ti:sapphire technology for space use. SEO's Titan-CW series of Ti:sapphire tunable lasers have applicability in analytical equipment designed for qualitative analysis of carbohydrates and proteins, structural analysis of water, starch/sugar analyses, and measurements of salt in meat. Further applications are expected in semiconductor manufacture, in medicine for diagnosis and therapy, and in biochemistry.

Source record↗

Plant growth during the Greenhouse II experiment on the Mir orbital station

We carried out three experiments with Super Dwarf wheat in the Bulgarian/Russian growth chamber Svet (0.1 m2 growing area) on the Space Station Mir. This paper mostly describes the first of these NASA-supported trials, began on Aug. 13, 1995. Plants were sampled five times and harvested on Nov. 9 after 90 days. Equipment failures led to low irradiance (3, then 4 of 6 lamp sets failed), instances of high temperatures (ca. 37 degrees C), and sometimes excessive substrate moisture. Although plants grew for the 90 d, no wheat heads were produced. Considering the low light levels, plants were surprisingly green, but of course biomass production was low. Plants were highly disoriented (low light, mirror walls?). Fixed and dried samples and the root module were returned on the U.S. Shuttle Atlantis on Nov. 20, 1995. Samples of the substrate, a nutrient-charged zeolite called Balkanine, were taken from the root module, carefully examined for roots, weighed, dried, and reweighed. The Svet control unit and the light bank were shipped to Moscow. An experiment validation test (EVT) of plant growth and experimental procedures, carried out in Moscow, was highly successful. Equipment built in Utah to measure CO2, H2O vapor, irradiance, air and leaf (IR) temperature, O2, pressure, and substrate moisture worked well in the EVT and in space. After this manuscript was first prepared, plants were grown in Mir with a new light bank and controller for 123 d in late 1996 and 39 days in 1996/1997. Plants grew exceptionally well with higher biomass production than in any previous space experiment, but the ca. 280 wheat heads that were produced in 1996 contained no seeds. Ethylene in the cabin atmosphere was responsible. c2002 Published by Elsevier Science Ltd on behalf of COSPAR.

Mir Project↗

Continuous pH monitoring in a perfused bioreactor system using an optical pH sensor

Monitoring and regulating the pH of the solution in a bioprocess is one of the key steps in the success of bioreactor operation. An in-line optical pH sensor, based on the optical absorption properties of phenol red present in the medium, was developed and tested in this work for use in NASA space bioreactors based on a rotating wall-perfused vessel system supporting a baby hamster kidney (BHK-21) cell culture. The sensor was tested over three 30-day and one 124-day cell runs. The pH sensor initially was calibrated and then used during the entire cell culture interval. The pH reported by the sensor was compared to that measured by a fiber optically coupled Shimadzu spectrophotometer and a blood gas analyzer. The maximum standard error of prediction for all the four cell runs for development pH sensor against BGA was +/-0.06 pH unit and for the fiber optically coupled Shimadzu spectrophotometer against the blood gas analyzer was +/-0.05 pH unit. The pH sensor system performed well without need of recalibration for 124 days. Copyright 2002 Wiley Periodicals, Inc.

Bioreactors↗

Anatomical and functional characteristics of carotid sinus stimulation in humans

Transmission characteristics of pneumatic pressure to the carotid sinus were evaluated in 19 subjects at rest and during exercise. Either a percutaneous fluid-filled (n = 12) or balloon-tipped catheter (n = 7) was placed at the carotid bifurcation to record internal transmission of external neck pressure/neck suction (NP/NS). Sustained, 5-s pulses, and rapid ramping pulse protocols (+40 to -80 Torr) were recorded. Transmission of pressure stimuli was less with the fluid-filled catheter compared with that of the balloon-tipped catheter (65% vs. 82% negative pressure, 83% vs. 89% positive pressure; P < 0.05). Anatomical location of the carotid sinus averaged 3.2 cm (left) and 3.6 cm (right) from the gonion of the mandible with a range of 0-7.5 cm. Transmission was not altered by exercise or Valsalva maneuver, but did vary depending on the position of the carotid sinus locus beneath the sealed chamber. These data indicate that transmission of external NP/NS was higher than previously recorded in humans, and anatomical variation of carotid sinus location and equipment design can affect transmission results.

Randomized Controlled Trial↗

Analysis of space radiation data of semiconductor memories

This article presents an analysis of radiation effects for several select device types and technologies aboard the Combined Release and Radiation Effects Satellite (CRRES) satellite. These space-flight measurements covered a period of about 14 months of mission lifetime. Single Event Upset (SEU) data of the investigated devices from the Microelectronics Package (MEP) were processed and analyzed. Valid upset measurements were determined by correcting for invalid readings, hard failures, missing data tapes (thus voids in data), and periods over which devices were disabled from interrogation. The basic resolution time of the measurement system was confirmed to be 2 s. Lessons learned, important findings, and recommendations are presented.

Flight Experiment↗

Zero-Gravity Locomotion Simulators: New Ground-Based Analogs for Microgravity Exercise Simulation

Maintaining health and fitness in crewmembers during space missions is essential for preserving performance for mission-critical tasks. NASA's Exercise Countermeasures Project (ECP) provides space exploration exercise hardware and monitoring requirements that lead to devices that are reliable, meet medical, vehicle, and habitat constraints, and use minimal vehicle and crew resources. ECP will also develop and validate efficient exercise prescriptions that minimize daily time needed for completion of exercise yet maximize performance for mission activities. In meeting these mission goals, NASA Glenn Research Center (Cleveland, OH, USA), in collaboration with the Cleveland Clinic (Cleveland, Ohio, USA), has developed a suite of zero-gravity locomotion simulators and associated technologies to address the need for ground-based test analog capability for simulating in-flight (microgravity) and surface (partial-gravity) exercise to advance the health and safety of astronaut crews and the next generation of space explorers. Various research areas can be explored. These include improving crew comfort during exercise, and understanding joint kinematics and muscle activation pattern differences relative to external loading mechanisms. In addition, exercise protocol and hardware optimization can be investigated, along with characterizing system dynamic response and the physiological demand associated with advanced exercise device concepts and performance of critical mission tasks for Exploration class missions. Three zero-gravity locomotion simulators are currently in use and the research focus for each will be presented. All of the devices are based on a supine subject suspension system, which simulates a reduced gravity environment by completely or partially offloading the weight of the exercising test subject s body. A platform for mounting treadmill is positioned perpendicularly to the test subject. The Cleveland Clinic Zero-g Locomotion Simulator (ZLS) utilizes a pneumatic subject load device to apply a near constant gravity-replacement load to the test subject during exercise, and is currently used in conjunction with the General Clinical Research Center for evaluating exercise protocols using a bedrest analog. The enhanced ZLS (eZLS) at NASA Glenn Research Center features an offloaded treadmill that floats on a thin film of air and interfaces to a force reaction frame via variably-compliant isolators, or vibration isolation system. The isolators can be configured to simulate compliant interfaces to the vehicle, which affects mechanical loading to crewmembers during exercise, and has been used to validate system dynamic models for new countermeasures equipment designs, such as the second International Space Station treadmill slated for use in 2010. In the eZLS, the test subject and exercise device can be pitched at the appropriate angle for partial gravity simulations, such as lunar gravity (1/6th earth gravity). On both the eZLS and the NASA-Johnson Space Center standalone ZLS installed at the University of Texas Medical Branch in Galveston, Texas, USA, the subject's body weight relative to the treadmill is controlled via a linear motor subject load device (LM-SLD). The LM-SLD employs a force-feedback closed-loop control system to provide a relatively constant force to the test subject during locomotion, and is set and verified for subject safety prior to each session. Locomotion data were collected during parabolic flight and on the eZLS. The purpose was to determine the similarities and differences between locomotion in actual and simulated microgravity. Subjects attained greater amounts of hip flexion during walking and running during parabolic flight. During running, subjects had greater hip range of motion. Trunk motion was significantly less on the eZLS than during parabolic flight. Peak impact forces, loading rate, and impulse were greater on the eZLS than during parabolic while walking with a low external load (EL) and rning with a high EL. Activation timing differences existed between locations in all muscles except for the rectus femoris. The tibialis anterior and gluteus maximus were active for longer durations on the eZLS than in parabolic flight during walking. Ground reaction forces were greater with the LM-SLD than with bungees during eZLS locomotion. While the eZLS serves as a ground-based analog, researchers should be aware that subtle, but measurable, differences in kinematics and leg musculature activities exist between the environments. Aside from space applications, zero-gravity locomotion simulators may help medical researchers in the future with development of rehabilitative or therapeutic protocols for injured or ill patients. Zero-gravity locomotion simulators may be used as a ground-based test bed to support future missions for space exploration, and eventually may be used to simulate planetary locomotion in partial gravity environments, including the Moon and Mars. Figure: Zero-gravity Locomotion Simulator at the Cleveland Clinic, Cleveland, Ohio, USA

Perusek, Gail P.↗

Pulmonary Toxicity of Simulated Lunar and Martian Dusts Intratracheally Instilled into Mice

The National Aeronautics and Space Administration (NASA) is contemplating sending humans to Mars and to the Moon for further exploration. Equipment designated for these extraterrestrial bases will require testing in simulated Martian or lunar environments. The properties of Hawaiian and San Francisco Mountain volcanic ashes make them suitable to be used in these test environments as Martian and lunar dust simulants, respectively. The present toxicity study was conducted to address NASA's concern about the health risk of dust exposures in the test facilities. In addition, the results obtained on these simulants can be used to design a toxicity study of actual moon dust and Martian dust, which will probably be available in a few years. Respirable portions of lunar soil simulant (LSS) and Martian soil simulant (MSS) were separated from their respective raw materials. These soil simulants, together- with fine titanium dioxide (negative control for fibrogenesis in mice), and crystalline silica (positive control) were each intratracheally instilled in saline to groups of 4 male mice (C57BL/6J, 2-3 months old) at 0.1 mg/mouse (LD) or lmg/mouse (HD). The lungs were harvested 7 or 90 days after the single dust treatment for histopathological examination. Lungs of the LSS-LD groups on either the 7- or 90-day study showed no evidence of inflammation, edema, or fibrosis. Clumps of particles and an increased number of macrophages, visible in the lungs examined after 7 days, were absent after 90 days. The LSS-HD-7d group showed mild to moderate alveolitis with neutrophilic and lymphocytic infiltration, and mild perivascular and peribronchiolar inflammation. The LSS-HD-90d group showed signs of chronic inflammation: septal thickening, mild perivascular and peribronchiolar inflammation, mild alveolitis and some fibrosis. Foci of particle-laden macrophages (PLMs) were still visible. Lungs of the MSS-LD-7d group revealed mild focal intraalveolar inflammation with neutrophilic and lymphocytic infiltration, and mild perivascular and peribronchiolar inflammation. The MSS-LD-90d group showed PLMs and scattered foci of mild fibrosis. The MSS-HD-7d group showed large foci of PLMs, intraalveolar debris, mild to moderate focal alveolitis, and mild to moderate perivascular and peribronchiolar inflammation. The MSS-HD-90d group showed focal chronic mild to moderate alveolitis and fibrosis. To mimic the oxidative and reactive properties of Martian surface dust in the test animals, groups of 4 mice were exposed to ozone (0.5 ppm for 3 hours) prior to instillation of the MSS. Lung lesions in the MSS groups were more severe with the ozone pretreatment. The O3-MSS-HD-90d group had wide spread intraalveolar debris, focal moderate alveolitis and fibrosis. The results for the titanium dioxide and quartz controls were consistent with the known pulmonary toxicity of these compounds. The overall severity of toxic injury to the lungs was TiO2<LSS<MSS<MSS+O3<quartz. In general, the toxic responses increased with the increase of dust burden in the lung. Except for TiO2, the increased duration of dust presence in the lung from 7 to 90 days transformed the acute inflammatory response to a chronic inflammatory lesion.

Lam, Chiu-Wing↗

A Review of International Space Station Habitable Element Equipment Offgassing Characteristics

Crewed spacecraft trace contaminant control employs both passive and active methods to achieve acceptable cabin atmospheric quality. Passive methods include carefully selecting materials of construction, employing clean manufacturing practices, and minimizing systems and payload operational impacts to the cabin environment. Materials selection and manufacturing processes constitute the first level of equipment offgassing control. An element-level equipment offgassing test provides preflight verification that passive controls have been successful. Offgassing test results from multiple International Space Station (ISS) habitable elements and cargo vehicles are summarized and implications for active contamination control equipment design are discussed

Perry, Jay L.↗

The Importance of Human Reliability Analysis in Human Space Flight: Understanding the Risks

HRA is a method used to describe, qualitatively and quantitatively, the occurrence of human failures in the operation of complex systems that affect availability and reliability. Modeling human actions with their corresponding failure in a PRA (Probabilistic Risk Assessment) provides a more complete picture of the risk and risk contributions. A high quality HRA can provide valuable information on potential areas for improvement, including training, procedural, equipment design and need for automation.

Hamlin, Teri L.↗

Instrumentation & Data Acquisition System (D AS) Engineer

The primary job of an Instrumentation and Data Acquisition System (DAS) Engineer is to properly measure physical phenomenon of hardware using appropriate instrumentation and DAS equipment designed to record data during a specified test of the hardware. A DAS system includes a CPU or processor, a data storage device such as a hard drive, a data communication bus such as Universal Serial Bus, software to control the DAS system processes like calibrations, recording of data and processing of data. It also includes signal conditioning amplifiers, and certain sensors for specified measurements. My internship responsibilities have included testing and adjusting Pacific Instruments Model 9355 signal conditioning amplifiers, writing and performing checkout procedures, writing and performing calibration procedures while learning the basics of instrumentation.

Jackson, Markus Deon↗

Orion Portable Fire Extinguisher Performance Testing Against a Laptop Lithium-Ion Battery Stored-Energy Fire-Method, Magnesium Fires, and Combustion By-Product Toxicity

As part of the qualification of the International Space Station (ISS) fine water mist portable fire extinguisher (PFE), several test methods were developed to determine firefighting capability against stored-energy sources. The most challenging of these devised stored-energy fire test methods proved to be the Lithium-ion (Li-ion) battery fire test scenario. The Orion crew capsule will utilize a different PFE technology from ISS (water spray rather than water mist), which spurred the need for the same type of evaluation focused on the sources of stored energy slated for use on Orion. Laptops were identified as a realistic source for stored-energy fires, requiring a modified Li-ion battery fire test scenario. In addition to open test cell (ambient oxygen concentration) testing to evaluate new proposed PFE performance, sealed chamber (20.9% and elevated oxygen concentration) testing was also performed. Chamber testing included combustion product sampling at various fire progression points for analysis and application to Orion emergency equipment design and response planning. The PFE stored-energy fire test methodology was modified and testing performed. Initial tests indicated ignition of the laptop magnesium laptop cases was possible. Additional tests were performed to characterize the laptop magnesium case fire behavior in various configurations. The new water spray PFE technology proved effective in extinguishing laptop stored-energy fires, and much was learned in the way these types of fires progressed. Findings indicate potential laptop magnesium case ignition mitigation strategies need to be further investigated.

Harper, Susana A.↗

Full Lunar Surface Visualization and Simulation Platform

This project created a visualization and simulation software platform for the entire lunar surface. Given the polar Artemis landing targets, the challenging terrain, lighting, and associated integrated crew / vehicle risk assessment, a more integrated approach to mission safety certification, potentially impacting equipment design and crew activity is required. This integrated capability will enable Safety and Mission Assurance (SMA), Flight Operations (FOD), and EVA to effectively collaborate to reduce human lunar exploration operational risk utilizing the identical tools to perform mission planning, rehearsal simulations, and providing the Safety Review Panel with integrated risk analysis capability.

information fusion↗

Development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements

The development of high temperature containerless processing equipment and the design and evaluation of associated systems required for microgravity materials processing and property measurements are discussed. Efforts were directed towards the following task areas: design and development of a High Temperature Acoustic Levitator (HAL) for containerless processing and property measurements at high temperatures; testing of the HAL module to establish this technology for use as a positioning device for microgravity uses; construction and evaluation of a brassboard hot wall Acoustic Levitation Furnace; construction and evaluation of a noncontact temperature measurement (NCTM) system based on AGEMA thermal imaging camera; construction of a prototype Division of Amplitude Polarimetric Pyrometer for NCTM of levitated specimens; evaluation of and recommendations for techniques to control contamination in containerless materials processing chambers; and evaluation of techniques for heating specimens to high temperatures for containerless materials experimentation.

Rey, Charles A.↗

Maintainability design criteria for packaging of spacecraft replaceable electronic equipment.

Maintainability must be designed into long-duration spacecraft and equipment to provide the required high probability of mission success with the least cost and weight. The ability to perform repairs quickly and easily in a space environment can be achieved by imposing specific maintainability design criteria on spacecraft equipment design and installation. A study was funded to investigate and define design criteria for electronic equipment that would permit rapid removal and replacement in a space environment. The results of the study are discussed together with subsequent simulated zero-g demonstration tests of a mockup with new concepts for packaging.

Kappler, J. R.↗