Standard Energy Efficiency Data Platform® [SWR-17-25]

The Standard Energy Efficiency Data Platform® (SEED Platform) provides public agencies and other organizations with a standardized but flexible, cost-effective, secure, enterprise data platform to manage portfolio scale building performance data from a variety of sources. The SEED Platform streamlines the administrative effort required by public agencies implementing building performance and transparency programs.

Source record↗

Best Practices Guide for Energy-Efficient Data Center Design

This guide provides an overview of best practices for energy-efficient data center design which spans the categories of information technology (IT) systems and their environmental conditions, data center air management, cooling and electrical systems, and heat recovery. IT system energy efficiency and environmental conditions are presented first because measures taken in these areas have a cascading effect of secondary energy savings for the mechanical and electrical systems. This guide concludes with a section on metrics and benchmarking values by which a data center and its systems energy efficiency can be evaluated. No design guide can offer “the most energy-efficient” data center design but the guidelines that follow offer suggestions that provide efficiency benefits for a wide variety of data center scenarios.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Low-Income Energy Affordability Data (LEAD) Tool Methodology

Methodology document describing the underlying data and analysis behind the Low-income Energy Affordability Data (LEAD) Tool, a web-accessible, interactive platform developed by U.S. Department of Energy and National Renewable Energy Laboratory that allows users to build their own national, state, city, or county profiles with estimated, locally specific low-income household energy characteristics. Users are able to visualize the profiles as well as compare differences among profiles. In addition, users will be able to save their profiles and download visualizations and data. characteristics. Users are able to visualize the profiles as well as compare differences among profiles. In addition, users will be able to save their profiles and download visualizations and data.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Demonstration of Data Center Energy Use Prediction Software

This report documents a demonstration of a software modeling tool from Romonet that was used to predict energy use and forecast energy use improvements in an operating data center. The demonstration was conducted in a conventional data center with a 15,500 square foot raised floor and an IT equipment load of 332 kilowatts. It was cooled using traditional computer room air handlers and a compressor-based chilled water system. The data center also utilized an uninterruptible power supply system for power conditioning and backup. Electrical energy monitoring was available at a number of locations within the data center. The software modeling tool predicted the energy use of the data center's cooling and electrical power distribution systems, as well as electrical energy use and heat removal for the site. The actual energy used by the computer equipment was recorded from power distribution devices located at each computer equipment row. The model simulated the total energy use in the data center and supporting infrastructure and predicted energy use at energy-consuming points throughout the power distribution system. The initial predicted power levels were compared to actual meter readings and were found to be within approximately 10 percent at a particular measurement point, resulting in a site overall variance of 4.7 percent. Some variances were investigated, and more accurate information was entered into the model. In this case the overall variance was reduced to approximately 1.2 percent. The model was then used to predict energy use for various modification opportunities to the data center in successive iterations. These included increasing the IT equipment load, adding computer room air handler fan speed controls, and adding a water-side economizer. The demonstration showed that the software can be used to simulate data center energy use and create a model that is useful for investigating energy efficiency design changes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Storage Data Submission Guidelines

In order to consider and understand emerging energy storage technologies, data analysis can be executed to ascertain proper operation and performance. The technical benefits of rigorous testing and data analysis are important for the customer, the planner, developer, and system operator: the end-user has a safe, reliable system that performs predictably on a macro level. The test-and-analyze approach to verifying performance of energy storage devices, equipment, and systems integration into the grid improves the understanding of the value of energy storage over time from the economic vantage point. Demonstrating the lifecycle value of energy storage begins with the data the provider supplies for analysis. After review of energy storage data received from several providers, it has become clear that some ESS data is inconsistent and incomplete - thus leading to a question of the inefficacy of the data when it comes time to analyze it. This paper will review and propose general guidelines such as sampling rates and data points that providers must supply in order for robust data analysis to take place. Consistent guidelines are the basis of the proper protocol to (a) reduce time it takes data to reach those who are providing analyses; (b) allow them to better understand the energy storage installations; and (c) provide high quality analysis of the installation. This paper intends to serve as a starting point for what data points should be provided when monitoring. As battery technologies continue to advance and the industry expands, this paper will be updated to remain current.

25 ENERGY STORAGE↗

United States Data Center Energy Usage Report: 2025 Update

This report updates the 2024 Data Center Energy Usage Report (2024 Report) and estimates that data centers could account for 11.8% of total U.S. electricity by 2030. The estimate also includes a range of scenarios that indicate the energy use could be between 9.5 and 15.3% of total U.S. electricity use by 2030. In comparison, the 2024 Report estimate range was 6.7% to 12.0% of total U.S. electricity by 2028.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

DCDM1: Lessons Learned from the World's Most Energy Efficient Data Center

This presentation discusses the holistic approach to design the world's most energy-efficient data center, which is located at the U.S. Department of Energy National Renewable Energy Laboratory (NREL). This high-performance computing (HPC) data center has achieved a trailing twelve-month average power usage effectiveness (PUE) of 1.04 and features a chiller-less design, component-level warm-water liquid cooling, and waste heat capture and reuse. We provide details of the demonstrated PUE and energy reuse effectiveness (ERE) and lessons learned during four years of production operation. Recent efforts to dramatically reduce the water footprint will also be discussed. Johnson Controls partnered with NREL and Sandia National Laboratories to deploy a thermosyphon cooler (TSC) as a test bed at NREL's HPC data center that resulted in a 50% reduction in water usage during the first year of operation. The Thermosyphon Cooler Hybrid System (TCHS) integrates the control of a dry heat rejection device with an open cooling tower.

97 MATHEMATICS AND COMPUTING↗

Data Center Energy Efficiency and Renewable Energy Site Assessment: Anderson Readiness Center; Salem, Oregon

This report summarizes the results from the data center energy efficiency and renewable energy site assessment conducted for the Oregon Army National Guard in Salem, Oregon. A team led by NREL conducted the assessment of the Anderson Readiness Center data centers March 18-20, 2014 as part of ongoing efforts to reduce energy use and incorporate renewable energy technologies where feasible. Although the data centers in this facility account for less than 5% of the total square footage, they are estimated to be responsible for 70% of the annual electricity consumption.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Data Center Energy Efficiency

Fact sheet describes how the Federal Energy Management Program helps federal agencies implement data center energy efficiency projects.

Kam, Kendall [US Department of Energy (USDOE) Fede↗

Towards Trust-Augmented Visual Analytics for Data-Driven Energy Modeling

The promise of data-driven predictive modeling is being increasingly realized in various science and engineering disciplines, where experts are used to the more conventional, simulation-driven modeling practices. However, trust remains a bottleneck for greater adoption of machine learning-based models for domain experts, who might not be necessarily trained in data science. In this paper, we focus on the building energy domain, where physics-based simulations are being complemented or replaced by machine learning-based methods for forecasting energy supply and demand at various spatio-temporal scales. We study the trust problem in close collaboration with energy scientists and engineers and describe how visual analytics can be leveraged for alleviating this trust bottleneck for stakeholders with varying degrees of expertise and analytics goals in this domain.

Kandakatla, Akshith R.↗

Holistic Approach to Data Center Energy Efficiency

This presentation discusses NREL's Energy System Integrations Facility and NREL's holistic design approach to sustainable data centers that led to the world's most energy-efficient data center. It describes Peregrine, a warm water liquid cooled supercomputer, waste heat reuse in the data center, demonstrated PUE and ERE, and lessons learned during four years of operation.

97 MATHEMATICS AND COMPUTING↗

Improving Data Center Energy Efficiency Through End-to-End Cooling Modeling and Optimization. Final Report

This report summarizes the development and demonstration of the three features developed for the DOE project “Improving Data Center Energy Efficiency through End-to-End Cooling Modeling and Optimization” (Award No. DE-EE0007688). The development of the three software features, Feature 1: Optimization of Cooling System Operation, Feature 2: Optimization of Airflow Management System, and Feature 3: Simultaneous Optimization of Airflow Management and Cooling Systems, are described first. Feature 1 is implemented in Phase 1 of the project and demonstrates 15% energy savings from cooling system optimization by applying the proposed retrofit solutions. Feature 2 is implemented in Phase 2 and the assessments show cooling energy-saving potential between 19.3% and 54.0%, depending on the energy-saving measures employed. In addition, investigating the energy saving potential for a hypothetical simple data center shows about 6.8% energy savings by optimizing the server load placement. Feature 3 is implemented in Phase 3 and the results show energy savings of 53.4% and 74.6% for the two partner data centers, respectively, compared to the baselines defined in Phase 1. Lastly, the project outcomes including software releases and publications are discussed.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Laser geodynamic satellite thermal/optical/vibrational analysis and testing, volume 2, book 2

The main tasks described involved an interferometric evaluation of several cubes, a prediction of their dihedral angles, a comparison of these predictions with independent measurements, a prediction and comparison of far field performance, recommendations as to revised dihedral angles and a subsequent analysis of cubes which were reworked to confirm the recommendations. A tolerance study and theoretical evaluation of several cubes was also performed to aid in understanding the results. The far field characteristics evaluated included polarization effects and treated both intensity distribution and encircled energy data. The energy in the 13.2 - 16.9 arc-sec annular region was tabulated as an indicator of performance sensitivity. The results are provided in viewgraph form, and show the average dihedral angle of an original set of test cubes to have been 1.8 arc-sec with an average far field annulus diameter of 18 arc-sec. Since the peak energy in the 13.2 - 16.9 arc-sec annulus was found to occur for a 1.35 arc-sec cube, and since cube tolerances were shown to increase the annulus diameter slightly, a nominal dihedral angle of 1.25 arc-sec was recommended.

Source record↗

Community-Scale Attic Retrofit and Home Energy Upgrade Data Mining

The U.S. Department of Energy’s Building America research team, Alliance for Residential Building Innovation (ARBI), implemented a project to increase residential retrofits in Davis, California. The project used a neighborhood-focused strategy for implementation and a low-cost retrofit program that focused on upgraded attic insulation and duct sealing. ARBI worked with a community partner, the not-for-profit Cool Davis Initiative, as well as selected area contractors to implement a strategy that sought to capitalize on the strong local expertise of partners and the unique aspects of the Davis, California, community. Working with community partners also allowed ARBI to collect and analyze data about effective messaging tactics for community-based retrofit programs.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Revealing Occupancy Patterns in an Office Building through the Use of Occupancy Sensor Data

Energy simulation programs like DOE-2 and EnergyPlus are tools that have been proven to aid with energy calculations to predict energy use in buildings. Some inputs to energy simulation models are relatively easy to find, including building size, orientation, construction materials, and HVAC system size and type. Others vary with time (e.g. weather and occupancy) and some can be a challenge to estimate in order to create an accurate simulation. In this paper, the analysis of occupancy sensor data for a large commercial, multi-tenant office building is presented. It details occupancy diversity factors for private offices and summarizes the same for open offices, hallways, conference rooms, break rooms, and restrooms in order to better inform energy simulation parameters. Long-term data were collected allowing results to be presented to show variations of occupancy diversity factors in private offices for time of day, day of the week, holidays, and month of the year. The diversity factors presented differ as much as 46% from those currently published in ASHRAE 90.1 2004 energy cost method guidelines, a document referenced by energy modelers regarding occupancy diversity factors for simulations. This may result in misleading simulation results and may introduce inefficiencies in the final equipment and systems design.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗