At least 181 records · Page 10

Sensor Tracks the Sun From Any Angle

Sensor system locates Sun from any angle and generates error signals to point object toward Sun and follow its motion. Sun-sensor system includes three photodetectors, each with separate field of view defined by set of apertures. As equipment rotates about axis, detectors put out time-varying signals processed by external electronics to determine rotation rate and direction to Sun.

Birnbaum, M., M.↗

Temporal Gain Correction for X-Ray Calorimeter Spectrometers

Calorimetric X-ray detectors are very sensitive to their environment. The boundary conditions can have a profound effect on the gain including heat sink temperature, the local radiation temperature, bias, and the temperature of the readout electronics. Any variation in the boundary conditions can cause temporal variations in the gain of the detector and compromise both the energy scale and the resolving power of the spectrometer. Most production X-ray calorimeter spectrometers, both on the ground and in space, have some means of tracking the gain as a function of time, often using a calibration spectral line. For small gain changes, a linear stretch correction is often sufficient. However, the detectors are intrinsically non-linear and often the event analysis, i.e., shaping, optimal filters etc., add additional non-linearity. Thus for large gain variations or when the best possible precision is required, a linear stretch correction is not sufficient. Here, we discuss a new correction technique based on non-linear interpolation of the energy-scale functions. Using Astro-HSXS calibration data, we demonstrate that the correction can recover the X-ray energy to better than 1 part in 104 over the entire spectral band to above 12 keV even for large-scale gain variations. This method will be used to correct any temporal drift of the on-orbit per-pixel gain using on-board calibration sources for the SXS instrument on the Astro-H observatory.

X-ray detector X-ray spectrometer X-ray calorimete↗

Simulating Alpha Particles Incident on MKID Chips for Quantum Sensitivity Analysis

Superconducting quantum devices, such as microwave kinetic inductance detectors (MKIDs), are highly sensitive instruments used in quantum computing and advanced sensing technologies. However, their extreme sensitivity also makes them vulnerable to background noise from natural sources like radiation. One significant contributor to this noise is alpha particles emitted by 210Po, a radon decay daughter that accumulates on surfaces near the detector. This project investigates how alpha particles emitted from 210Po interact with MKID chips. These particles can deposit energy on the detector surface, disrupting its operation and generating false signals. Understanding the energy and behavior of these particles is crucial for improving the design and reliability of quantum devices. To explore this, we first modeled the decay chain starting from 210Pb to 210Po using differential equations. This allowed us to predict how the activity of alpha-emitting isotopes changes over time, reaching a steady state after about two years. Next, we simulated alpha particle interactions with the MKID chip using the Geant4 software toolkit. We built a detailed computer model of the detector housing, including the copper lid where alpha particles originate, the silicon chip, and a thin aluminum sensor layer. Alpha particles were emitted isotropically from just beneath the copper lid’s surface, mimicking natural decay conditions. The simulation tracked how these particles deposit energy on the chip, generating electron-hole pairs and phonons. The results provide insight into the behavior of the resultant electron-hole pairs and phonons, giving us a clear understanding of the energy deposition distribution on the chip. This work supports efforts to mitigate background noise in superconducting sensors, advancing their use in quantum computing and sensitive physics experiments.

Hall, Matthew [Fermilab; UCLA]↗

Detectors for energies greater than 10 MeV

The detector telescopes used in gamma ray astronomy in general are more similar to particle detectors than to optical devices, since the high frequency of the radiation precludes the use of reflection or diffraction techniques, but the high energy content of each photon does enable them to be detected with scintillators, track imaging chambers, and solid state detectors. Within the gamma ray range, the basic design of the instrument changes as the energy of the gamma ray exceeds 10 to 20 MeV, and therefore, moves from the region where the Compton effect predominates in the absorption of the gamma ray to that where electron pair production is most important. In the energy range from 10 to 20 MeV to several times 10,000 MeV, gamma ray telescopes are usually built so that the electron pair may be seen and the properties of the electrons measured.

Source record↗

Solid state instrumentation concepts for earth resource observation

Late in 1980, specifications were prepared for detail design definition of a six band solid state multispectral instrument having three visible (VIS), one near infrared (NIR), and two short wave infrared (SWIR) bands. This instrument concept, known as the Multispectral Linear Array (MLA), also offered increased spatial resolution, on board gain and offset correction, and additional operational modes which would allow for cross track and stereoscopic viewing as well as a multialtitude operational capability. A description is presented of a summary of some of the salient features of four different MLA design concepts, as developed by four American companies. The designs ranged from the use of multiple refractive telescopes utilizing three groups of focal plane detectors electronic correlation processing for achieving spatial registration, and incorporating palladium silicide (PdSi) SWIR detectors, to a four-mirror all-reflective telecentric system utilizing a beam splitter for spatial registration.

Richard, H. L.↗

Characterization and Design of Digital Pointing Subsystem for Optical Communication Demonstrator

The Optical Communications Demonstrator (OCD) is a laboratory-based lasercom demonstration terminal designed to validate several key technologies, including beacon acquisition, high bandwidth tracking, precision bearn pointing, and point-ahead compensation functions. It has been under active development over the past few years. The instrument uses a CCD array detector for both spatial acquisition and high-bandwidth tracking, and a fiber coupled laser transmitter. The array detector tracking concept provides wide field-of-view acquisition and permits effective platform jitter compensation and point-ahead control using only one steering mirror. This paper describes the detailed design and characterization of the digital control loop system which includes the Fast Steering Mirror (FSM), the CCD image tracker, and the associated electronics. The objective is to improve the overall system performance using laboratory measured data. The. design of the digital control loop is based on a linear time invariant open loop model. The closed loop performance is predicted using the theoretical model. With the digital filter programmed into the OCD control software, data is collected to verify the predictions. This paper presents the results of the, system modeling and performance analysis. It has been shown that measurement data closely matches theoretical predictions. An important part of the laser communication experiment is the ability of FSM to track the laser beacon within the. required tolerances. The pointing must be maintained to an accuracy that is much smaller than the transmit signal beamwidth. For an earth orbit distance, the system must be able to track the receiving station to within a few microradians. The failure. to do so will result in a severely degraded system performance.

Racho, C.↗

NASA Tech Briefs, July 2012

Topics covered include: Instrument Suite for Vertical Characterization of the Ionosphere-Thermosphere System; Terahertz Radiation Heterodyne Detector Using Two-Dimensional Electron Gas in a GaN Heterostructure; Pattern Recognition Algorithm for High-Sensitivity Odorant Detection in Unknown Environments; Determining Performance Acceptability of Electrochemical Oxygen Sensors; Versatile Controller for Infrared Lamp and Heater Arrays; High-Speed Scanning Interferometer Using CMOS Image Sensor and FPGA Based on Multifrequency Phase-Tracking Detection; Ultra-Low-Power MEMS Selective Gas Sensors; Compact Receiver Front Ends for Submillimeter-Wave Applications; Dynamically Reconfigurable Systolic Array Accelerator; Blocking Losses With a Photon Counter; Motion-Capture-Enabled Software for Gestural Control of 3D Mod; Orbit Software Suite; CoNNeCT Baseband Processor Module Boot Code SoftWare (BCSW); Trajectory Software With Upper Atmosphere Model; ALSSAT Version 6.0; Employing a Grinding Technology to Assess the Microbial Density for Encapsulated Organisms; Demonstration of Minimally Machined Honeycomb Silicon Carbide Mirrors; Polyimide Aerogel Thin Films; Nanoengineered Thermal Materials Based on Carbon Nanotube Array Composites; Composite Laminate With Coefficient of Thermal Expansion Matching D263 Glass; Robust Tensioned Kevlar Suspension Design; Focal Plane Alignment Utilizing Optical CMM; Purifying, Separating, and Concentrating Cells From a Sample Low in Biomass; Virtual Ultrasound Guidance for Inexperienced Operators; Beat-to-Beat Blood Pressure Monitor; Non-Contact Conductivity Measurement for Automated Sample Processing Systems; An MSK Radar Waveform; Telescope Alignment From Sparsely Sampled Wavefront Measurements Over Pupil Subapertures; Method to Remove Particulate Matter from Dusty Gases at Low Pressures; Terahertz Quantum Cascade Laser With Efficient Coupling and Beam Profile; Measurement Via Optical Near-Nulling and Subaperture Stitching; 885-nm Pumped Ceramic Nd:YAG Master Oscillator Power Amplifier Laser System; Airborne Hyperspectral Imaging System; Heat Shield Employing Cured Thermal Protection Material Blocks Bonded in a Large-Cell Honeycomb Matrix; and Asymmetric Supercapacitor for Long-Duration Power Storage.

Source record↗

Detector Apparatus and Method

Transceiver and methods are included that are especially suitable for detecting metallic materials, such as metallic mines, within an environment. The transceiver includes a digital waveform generator used to transmit a signal into the environment and a receiver that produces a digital received signal. A tracking module preferably compares an in-phase and quadrature transmitted signal with an in-phase and quadrature received signal to produce a spectral transfer function of the magnetic transceiver over a selected range of frequencies. The transceiver initially preferably creates a reference transfer function which is then stored in a memory. Subsequently measured transfer functions will vary depending on the presence of metal in the environment which was not in the environment when the reference transfer function was determined. The system may be utilized in the presence of other antennas, metal, and electronics which may comprise a plastic mine detector for detecting plastic mines. Despite the additional antennas and other metallic materials that may be in the environment due to the plastic mine detector, the magnetic transceiver remains highly sensitive to metallic material which may be located in various portions of the environment and which may be detected by sweeping the detector over ground that may contain metals or mines.

Arndt, G. Dickey↗

Computational models of direct and indirect X‐ray breast imaging detectors for in silico trials

Abstract Background To facilitate in silico studies that investigate digital mammography (DM) and breast tomosynthesis (DBT), models replicating the variety in imaging performance of the DM and DBT systems, observed across manufacturers are needed. Purpose The main purpose of this work is to develop generic physics models for direct and indirect detector technology used in commercially available systems, with the goal of making them available open source to manufacturers to further tweak and develop the exact in silico replicas of their systems. Methods We recently reported on an in silico version of the SIEMENS Mammomat Inspiration DM/DBT system using an open‐source GPU‐accelerated Monte Carlo x‐ray imaging simulation code (MC‐GPU). We build on the previous version of the MC‐GPU codes to mimic the imaging performances of two other Food and Drug Administration (FDA)‐approved DM/DBT systems, such as Hologic Selenia Dimensions (HSD) and the General Electric Senographe Pristina (GSP) systems. In this work, we developed a hybrid technique to model the optical spread and signal crosstalk observed in the GSP and HSD systems. MC simulations are used to track each x‐ray photon till its first interaction within the x‐ray detector. On the other hand, the signal spread in the x‐ray detectors is modeled using previously developed analytical equations. This approach allows us to preserve the modeling accuracy offered by MC methods in the patient body, while speeding up secondary carrier transport (either electron–hole pairs or optical photons) using analytical equations in the detector. The analytical optical spread model for the indirect detector includes the depth‐dependent spread and collection of optical photons and relies on a pre‐computed set of point response functions that describe the optical spread as a function of depth. To understand the capabilities of the computational x‐ray detector models, we compared image quality metrics like modulation transfer function (MTF), normalized noise power spectrum (NNPS), and detective quantum efficiency (DQE), simulated with our models against measured data. Please note that the purpose of these comparisons with measured data would be to gauge if the model developed as part of this work could replicate commercially used direct and indirect technology in general and not to achieve perfect fits with measured data. Results We found that the simulated image quality metrics such as MTF, NNPS, and DQE were in reasonable agreement with experimental data. To demonstrate the imaging performance of the three DM/DBT systems, we integrated the detector models with the VICTRE pipeline and simulated DM images of a fatty breast model containing a spiculated mass and a calcium oxalate cluster. In general, we found that the images generated using the indirect model appeared more blurred with a different noise texture and contrast as compared to the systems with direct detectors. Conclusions We have presented computational models of three commercially available FDA‐approved DM/DBT systems, which implement both direct and indirect detector technology. The updated versions of the MC‐GPU codes that can be used to replicate three systems are available in open source format through GitHub.

Sengupta, Aunnasha↗

Evolution of miniature detectors and focal plane arrays for infrared sensors

Sensors that are sensitive in the infrared spectral region have been under continuous development since the WW2 era. A quest for the military advantage of 'seeing in the dark' has pushed thermal imaging technology toward high spatial and temporal resolution for night vision equipment, fire control, search track, and seeker 'homing' guidance sensing devices. Similarly, scientific applications have pushed spectral resolution for chemical analysis, remote sensing of earth resources, and astronomical exploration applications. As a result of these developments, focal plane arrays (FPA) are now available with sufficient sensitivity for both high spatial and narrow bandwidth spectral resolution imaging over large fields of view. Such devices combined with emerging opto-electronic developments in integrated FPA data processing techniques can yield miniature sensors capable of imaging reflected sunlight in the near IR and emitted thermal energy in the Mid-wave (MWIR) and longwave (LWIR) IR spectral regions. Robotic space sensors equipped with advanced versions of these FPA's will provide high resolution 'pictures' of their surroundings, perform remote analysis of solid, liquid, and gas matter, or selectively look for 'signatures' of specific objects. Evolutionary trends and projections of future low power micro detector FPA developments for day/night operation or use in adverse viewing conditions are presented in the following test.

Watts, Louis A.↗

Performance and Commissioning of the BigBite Timing Hodoscope for Nucleon Form Factor Measurements at Jefferson Lab

The BigBite Timing Hodoscope detector is the primary subject of this thesis. The Super BigBite Spectrometer is a Jefferson Lab Hall A Collaboration project that has and will continue to measure nucleon electromagnetic form factors. This spectrometer includes the Timing Hodoscope which provides high resolution particle timing data for scattered electrons in the electron arm of BigBite. The Timing Hodoscope utilizes 90, 25 × 25 × 600 mm3 scintillator bars stacked on top of each other to form a single detector plane, and these bars are connected to 180 photo-multiplier tubes via light guides. Particles collide with the scintillating material creating a shower of optical photons and these particle events in the bars are collected to generate signals that are readout by the data acquisition (DAQ) electronics. NINO ASIC amplifier-discriminator cards output signals from the photo-multiplier tubes into analogue and logic signals, which are sent to analogue-to-digital (ADC) and time-to-digital (TDC) converter data acquisition readout modules. This data is then used for analysis of the detector. The focus of this thesis is the construction, commissioning, calibration, and performance of the BigBite Timing Hodoscope before and during the first of five nucleon electromagnetic form factor experiments at Jefferson Lab Hall A. Before the neutron magnetic form factor, G n M, experiment, cosmic ray data was collected during commissioning to confirm proper operation of the Timing Hodoscope electronics by observing the ADC and TDC data. Commissioning studies for charge normalization, gain matching, and other ADC and TDC detector data variables were performed before moving the detector into Hall A. Following installation in Hall A, several calibration studies were implemented to fine-tune the detector in preparation for use in the experiment. The calibration studies included analysis of timing cuts, TDC alignment, the time-walk effect, time difference offsets, and scintillator velocity corrections. Once the Timing Hodoscope was well-calibrated, data-taking during the experiment commenced and the beam-on-target data was used to characterize the Timing Hodoscope performance during the G n M experiment run-time. The performance analysis included studies observing energy deposit, cluster size, rates, accidentals, pile-up, tracking efficiency, position resolution, and time resolution. After application of physics cuts to ensure a data set comprised of particle tracks corresponding to elastic electrons, which is the main data of interest for measurement of G n M, the Timing Hodoscope is shown on average across all kinematic settings to have a >98% tracking efficiency, a position resolution of 4-6 cm in the non-dispersive plane and 1.5-2 cm in the dispersive plane, and a time resolution of 500-750 ps. These performance results are compared to a GEANT4 based performance simulation of the BigBite Timing Hodoscope for reference, showing to what degree the measured performance values match those taken from the simulation.

Marinaro, Ralph↗

Field Funneling and Range Straggling in Silicon Detectors

Magnitudes of field funneling and range straggling determined in silicon-surface-barrier (Schottky-barrier) charged-particle detectors (SSBD's) through meaurement of charges collected from alpha-particle tracks. Method used extended to straightforward measurement of charge collection from heavy-ion tracks in these and other semiconductor devices. Such measurements used to assess single-event upsets in integratedcircuit chips, with view toward making them resistant to radiation. Field funneling and range straggling measured with electronic system in which charge collected from individual ions measured and recorded by multichannel analyzer.

Zoutendyk, J. A.↗

Search for higgsinos in compressed mass spectra using low-momentum tracks in pp collisions at s=13 TeV with the ATLAS detector

This paper presents two searches for the electroweak production of higgsinos with compressed mass spectra using 140 fb−1 of s=13$$ \sqrt{s}=13 $$ TeV proton-proton collision data collected by the ATLAS experiment at the Large Hadron Collider. Events are required to feature an energetic jet, large missing transverse momentum, and at least one low-momentum charged particle that serves as a candidate higgsino decay product. In the first search, targeting higgsino mass splittings in the range of 0.3–1 GeV, the higgsinos are expected to predominantly decay into pions that are identified as low-momentum charged particles with large transverse impact parameters due to the long higgsino lifetime (cτ ≈ ?(0.1–10 mm)), and neural networks are used to discriminate between signal and background processes. The second search targets larger mass splittings in the range of 1–3 GeV, where the higgsinos are expected to decay promptly into low-momentum leptons, one of which is identified by dedicated low-momentum electron or muon taggers based on neural networks utilising tracking and calorimeter information. No significant excess above the Standard Model prediction is observed in either search and the results are interpreted within simplified models, to set lower limits on the masses of the higgsino-like charginos and neutralinos. Together, these searches exclude chargino masses below 126 GeV at 95% confidence level for mass splittings between the chargino and lightest neutralino in the range of 0.3–2 GeV. This represents the first ATLAS constraints in a portion of this parameter space and surpasses the limits previously set by other experiments.

Aad, G↗

Planetary Instrument Definition and Development Program (PIDDP). Instrument for future planetary flight missions: A visible-infrared imaging spectrometer for planetary missions

The objective of this project is to develop and prove a small, light-weight, efficient imaging spectrometer design to cover the VIS/NIR spectral range for applications particularly but not exclusively to NASA inner solar system space missions. A design and a brassboard prototype will be developed and tested. Progress over the first year of this project includes design specification, optical design layout, grating specifications, infrared detector selection, and mechanical design. Mechanical and grating manufacturing drawings were begun. We developed an agreement in principle to cooperate with the German space group, DLR, to apply some of their electronics microminiaturization technology to this imaging spectrometer project, mostly or entirely at their expense. Funds from NASA for the second year of this effort have been received and the effort is on track. Release of funds for the third year of this award will be requested later this year in order to accelerate this work and bring it to a conclusion in time for new NASA missions considerations as well as to make effective use of the DLR contributions.

Mccord, Thomas B.↗

Measurement of $\nu_\mu$ CC Interactions With Two-Proton Final State in MINERvA

This dissertation presents a measurement of charged–current (CC) muon–neutrino interactions with exactly two protons and no pions in the final state (CC~$2p\,0\pi$), using data collected by the MINERvA detector in the NuMI medium–energy beam at Fermilab. Such two–proton topologies are a sensitive probe of nuclear dynamics in the few–GeV regime, including multi–nucleon correlations (npnh, notably $2p2h$) and intranuclear final–state interactions (FSI) such as pion absorption and nucleon rescattering. A precise experimental characterization of these processes is essential both for neutrino–interaction theory and for reducing systematic uncertainties in oscillation experiments that rely on accurate modeling of neutrino–nucleus interactions. Events are selected by requiring a $\nu_\mu$ CC interaction with a reconstructed $\mu^-$ and two proton tracks originating from a common vertex in MINERvA’s finely segmented scintillator tracker, with no reconstructed mesons. Muon charge and momentum are constrained by matching to the MINOS Near Detector, while proton identification exploits energy–loss profiles and stopping–proton features. Backgrounds from pion–producing channels that enter the signal region through FSI or reconstruction effects are constrained with data–driven sidebands (Michel–electron and isolated–cluster “blob” samples) and tuned via a simultaneous fit across signal and sideband regions. To correct detector resolution and acceptance effects, the analysis employs iterative Bayesian unfolding with extensive validation: statistical pseudo–experiments, and robustness checks against generator systematic “universes” and additional strong shape warps. Single–differential cross sections are reported for three observables tailored to the two–proton final state: the opening–angle cosine $\cos\!\left(\theta_{pp}\right)$, the leading–proton momentum, and the subleading–proton momentum. Systematic uncertainties include contributions from neutrino flux, interaction modeling (e.g., npnh and resonance parameters, pion FSI), and detector response (calibration, reconstruction efficiencies). The resulting distributions provide targeted constraints on the interplay of multi–nucleon dynamics and FSI that shape CC~$2p\,0\pi$ final states on hydrocarbon. Comparisons to modern GENIE–based simulations highlight kinematic regions where model components require refinement. These measurements thus inform generator tuning and improve the reliability of neutrino–energy reconstruction strategies for current and future long–baseline oscillation programs.

Syrotenko, Vladyslav S. [Tufts U.]↗

MIRC-X: A Highly Sensitive Six-telescope Interferometric Imager at the CHARA Array

Michigan InfraRed Combiner-eXeter (MIRC-X) is a new highly sensitive six-telescope interferometric imager installed at the CHARA Array that provides an angular resolution equivalent of up to a 330 m diameter baseline telescope in J- and H-band wavelengths ((λ/(2B))∼0.6 mas). We upgraded the original Michigan InfraRed Combiner (MIRC) instrument to improve sensitivity and wavelength coverage in two phases. First, a revolutionary sub-electron noise and fast-frame-rate C-RED ONE camera based on an SAPHIRA detector was installed. Second, a new-generation beam combiner was designed and commissioned to (i) maximize sensitivity, (ii) extend the wavelength coverage to J band, and (iii) enable polarization observations. A low-latency and fast-frame-rate control software enables high-efficiency observations and fringe tracking for the forthcoming instruments of the CHARA Array. Since mid-2017, MIRC-X has been offered to the community and has demonstrated best-case H-band sensitivity down to 8.2 correlated magnitude. MIRC-X uses single-mode fibers to coherently combine the light from six telescopes simultaneously with an image-plane combination scheme and delivers a visibility precision better than 1%, and closure phase precision better than 1°. MIRC-X aims at (i) imaging protoplanetary disks, (ii) detecting exoplanets with precise astrometry, and (iii) imaging stellar surfaces and starspots at an unprecedented angular resolution in the near-infrared. In this paper, we present the instrument design, installation, operation, and on-sky results, and demonstrate the imaging capability of MIRC-X on the binary system ι Peg. The purpose of this paper is to provide a solid reference for studies based on MIRC-X data and to inspire future instruments in optical interferometry.

79 ASTRONOMY AND ASTROPHYSICS↗

The High Visible Resolution (HVR) instrument of the spot ground observation satellite

Two identical high resolution cameras, capable of attaining a track width of 116 km in an almost vertical line of sight from the two 60 km images of each instrument, will be carried on the initial mission of the space observation of Earth satellite (SPOT). Specifications for the instrument, including the telescope and CCD devices are summarized. The present status of development is described including the optical characteristics, structure and thermal control, detector assembly, electronic equipment, and calibration. SPOT mission objectives include the developments relating to soil use, the exploration of EART Earth resources, the discrimination of plant species, and cartography.

Otrio, G.↗

Understanding Solar Energetic Particles With STEREO HET

The project evaluates solar energetic particles (SEPs) in the Heliosphere utilizing in situ data from the STEREO mission. More specifically, raw data from the High Energy Telescope (HET) corresponding to the abundances and energy spectra of electrons, protons, He, and heavier nuclei was extracted. C codes were modified and written to analyze Pulse heights and fluxes in a readable format. Plots of the data were formulated in Python. Low fluxes of heavier elements prompted a revaluation of the onboard binning process. New selection criteria will be generated to orient the particle energy loss in the detectors with the expected locations of the energy tracks corresponding to each element.

Energetic Particles↗