Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Electrode materials”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Li-Ion Cell Development for Low Temperature Applications

JPL is involved in the development of rechargeable Li-ion cells for future Mars Exploration Missions. The specific objectives are to improve the Li-ion cell cycle life performance and rate capability at low temperature (<<-20 C) in order to enhance survivability of the Mars lander and rover batteries. Poor Li-ion rate capability at low temperature has been attributed to: (1) the electrolytes becoming viscous or freezing and/or (2) reduced electrode capacity that results from decreased Li diffusivity. Our efforts focus on increasing the rate capability at low temperature for Li-ion cells. In order to improve the rate capability we evaluated the following: (1) cathode performance at low temperatures, (2) electrode active material particle size on low temperature performance and (3) Li diffusivity at room temperature and low temperatures. In this paper, we will discuss the results of our study.

Huang, C.-K.↗

Super NiCd Open-Circuit Storage and Low Earth Orbit (LEO) Life Test Evaluation

This presentation discusses Air Force tests performed on super NiCd cells to measure their performance under conditions simulating Low Earth Orbit (LEO) conditions. Super NiCd cells offer potential advantages over existing NiCd cell designs including advanced cell design with improved separator material and electrode making processes, but handling and storage requires active charging. These tests conclude that the super NiCd cells support generic Air Force qualifications for conventional LEO missions (up to five years duration) and that handling and storage may not actually require active charging as previously assumed. Topics covered include: Test Plan, Initial Characterization Tests, Open-Circuit Storage Tests, and post storage capacities.

Baer, Jean Marie↗

Lightweight fibrous nickel electrodes for nickel-hydrogen batteries

The NASA Lewis Research Center is currently developing nickel electrodes for nickel-hydrogen batteries. These electrodes are lighter in weight and have higher energy densities than the heavier state-of-the-art sintered nickel electrodes. Lightweight fibrous materials or plaques are used as conductive supports for the nickel hydroxide active material. These materials are commercial products that are fabricated into nickel electrodes by electrochemically impregnating them with active material. Evaluation is performed in half cells structured in the bipolar configuration. Initial performance tests include capacity measurements at five discharge levels, C/2, 1.0C, 1.37C, 2.0C, and 2.74C. The electrodes that pass the initial tests are life cycle-tested in a low Earth orbit regime at 80 percent depth of discharge.

Britton, Doris L.↗

Expansion of the nickel electrode

To observe a reasonable amount of expansion, months or years in acutal batteries are required. Therefore, the technique of electrode bending was developed. Active material is taken off a sample electrode on one side, and left only on the other side with a cadmium counter electrode. With this configuration, if the active material expands, the electrode will bend convex - concave towards this direction. This very small bending may be easily detected with light deflection. A laser beam was used to project it on the screen through a mirror attached on the electrode, thus making a very sensitive measurement of a very small expansion.

Lim, H. S.↗

Carbon Cloth Supports Catalytic Electrodes

Carbon cloth is starting material for promising new catalytic electrodes. Carbon-cloth electrodes are more efficient than sintered-carbon configuration previously used. Are also chemically stable and require less catalyst--an important economic advantage when catalyst is metal such as platinum.

Lu, W. T. P.↗

High Performance Nickel Electrodes for Space Power Applications

Performance characteristics such as efficiency, specific energy density and power density of nickel electrodes are generally limited by the electrode microstructure and nature of the active material within the electrode matrix. Progress is being made in our laboratory in a collaborative effort with NASA-Lewis Research Center to develop lighter weight, mechanically stable and highly efficient nickel electrodes for aerospace applications. Our approach is based on an electrode microstructure fabricated from a mixture of nickel fibers as small as 2 microns diameter and cellulose fibers. Performance data in flooded cell tests and cycle life data are presented. Performance characteristics are compared to other electrode microstructures such as the Fibrex Fiber mat and the Fibrex Powder substrate. The flexibility of our electrode microstructure and the significant advantages it offers in terms of weight and performance are demonstrated, in particular, its ability to accept charge at high rates and to discharge at high rates.

Adanuvor, Prosper K.↗

Creep Testing of High-Temperature Cu-8 Cr-4 Nb Alloy Completed

A Cu-8 at.% Cr-4 at.% Nb (Cu-8 Cr-4 Nb) alloy is under development for high-temperature, high heatflux applications, such as actively cooled, hypersonic vehicle heat exchangers and rocket engine combustion chambers. Cu-8 Cr-4 Nb offers a superior combination of strength and conductivity. It has also shown exceptional low-cycle fatigue properties. Following preliminary testing to determine the best processing route, a more detailed testing program was initiated to determine the creep lives and creep rates of Cu-8 Cr-4 Nb alloy specimens produced by extrusion. Testing was conducted at the NASA Lewis Research Center with constant-load vacuum creep units. Considering expected operating temperatures and mission lives, we developed a test matrix to accurately determine the creep properties of Cu-8 Cr-4 Nb between 500 and 800 C. Six bars of Cu-8 Cr-4 Nb were extruded. From these bars, 54 creep samples were machined and tested. The figure on the left shows the steady-state, or second-stage, creep rates for the samples. Comparison data for NARloy-Z (Cu-3 wt % Ag-0.5 wt % Zr), the alloy currently used in combustion chamber liners, were not unavailable. Therefore the steady-state creep rates for Cu at similar temperatures are presented. As expected, in comparison to pure Cu, the creep rates for Cu-8 Cr-4 Nb are much lower. The lives of the samples are presented in the figure on the right. As shown, Cu-8 Cr-4 Nb at 800 C is comparable to NARloy-Z at 648 C. At equivalent temperatures, Cu-8 Cr-4 Nb enjoys a 20 to 50 percent advantage in stress for a given life and 1 to 3 orders of magnitude greater life at a given stress. The improved properties allow for design tradeoffs and improvements in new and existing heat exchangers such as the next generation of combustion chamber liners. Average creep rates for Cu-8 Cr-4 Nb and pure Cu are shown. Average creep lives for Cu-8 Cr- 4 Nb and NARloy-Z are also shown. Currently, two companies are interested in the commercial usage of the Cu-8 Cr-4 Nb alloy. The Rocketdyne Division of Rockwell International is conducting independent testing to analyze the properties for their projected needs in advanced rocket engine applications. Metallamics, a company based in Traverse City, Michigan, is entering into a Space Act Agreement to evaluate and test Cu-Cr-Nb alloys as materials for welding electrodes that are used in robotic welding operations. Creep rate is one of the alloy properties that determines the degree to which a welding electrode will mushroom or expand at the tip. A material with a low creep rate will resist mushrooming and give the electrode a longer life, minimizing downtime. This application holds the potential for large-scale usage of the alloy in the automotive and other industries. Success here would dramatically decrease the cost of the alloy and increase availability for aerospace applications.

Source record↗

Spark Ignition of Flowing Gases. 2: Effect of Electrode Parameters on Energy Required to Ignite a Propane-Air Mixture

Research was conducted to determine the effect of the electrode parameters of spacing, configuration, and material' on the energy required for ignition of a flowing propane-air mixture. In addition, the data were used to indicate the energy distribution along the spark length and to confirm previous observations concerning the effect of spark duration on ignition energy requirements. The data were obtained with a mixture at a fuel-air ratio of 0.0835 (by weight), a pressure of 3 inches of mercury absolute, a temperature of 80 F, and a mixture velocity of 5 feet per second. Results showed that the energy required for ignition decreased as the electrode spacing was increased; a minimum energy occurred at. a spacing of 0.65 inch for large electrodes. For small electrodes, the spacing for minimum energy was not sharply defined. Small-diameter electrodes required less energy than large-diameter electrodes if the spacing was less than the optimum distance of 0.65 inch; at a spacing equal to the optimum distance, no difference was noted. Significant effects of electrode material on ignition energy were ascribed to differences in the type of spark discharges produced; glow discharges required higher energy than the arc-glow discharges. With pure glow discharges, the ignition energy was substantially constant for lead, cadmium, brass, aluminum, and tungsten electrodes. A method is described for determining the energy distribution along a glow discharge. It was found that one-third to one-half of the energy in the spark was concentrated in a small region near the cathode electrode, and the remainder was uniformly distributed across the spark gap. It was impossible to ascertain the dependence of ignition on. this distribution. It was also observed that long-duration (600 microsec) sparks required much less energy for ignition than did short-duration (1 microsec) sparks.

Swett, Clyde. C., Jr.↗

Carbon Nanotube Based Light Sensor

A light sensor substrate comprises a base made from a semi-conductive material and topped with a layer of an electrically non-conductive material. A first electrode and a plurality of carbon nanotube (CNT)-based conductors are positioned on the layer of electrically non-conductive material with the CNT-based conductors being distributed in a spaced apart fashion about a periphery of the first electrode. Each CNT-based conductor is coupled on one end thereof to the first electrode and extends away from the first electrode to terminate at a second free end. A second or gate electrode is positioned on the non-conductive material layer and is spaced apart from the second free end of each CNT-based conductor. Coupled to the first and second electrode is a device for detecting electron transfer along the CNT-based conductors resulting from light impinging on the CNT-based conductors.

Wincheski, russell A.↗

Solid expellant plasma generator

An improved solid expellant plasma generator has been developed. The plasma generator includes a support housing, an electrode rod located in the central portion of the housing, and a mass of solid expellant material that surrounds the electrode rod within the support housing. The electrode rod and the solid expellant material are made of separate materials that are selected so that the electrode and the solid expellant material decompose at the same rate when the plasma generator is ignited. This maintains a point of discharge of the plasma at the interface between the electrode and the solid expellant material.

Stone, Nobie H.↗

MOS Circuitry Would Detect Low-Energy Charged Particles

Metal oxide semiconductor (MOS) circuits for measuring spatially varying intensities of beams of low-energy charged particles have been developed. These circuits are intended especially for use in measuring fluxes of ions with spatial resolution along the focal planes of mass spectrometers. Unlike prior mass spectrometer focal-plane detectors, these MOS circuits would not be based on ion-induced generation of electrons, and photons; instead, they would be based on direct detection of the electric charges of the ions. Hence, there would be no need for microchannel plates (for ion-to-electron conversion), phosphors (for electron-to-photon conversion), and photodetectors (for final detection) -- components that degrade spatial resolution and contribute to complexity and size. The developmental circuits are based on linear arrays of charge-coupled devices (CCDs) with associated readout circuitry (see figure). They resemble linear CCD photodetector arrays, except that instead of a photodetector, each pixel contains a capacitive charge sensor. The capacitor in each sensor comprises two electrodes (typically made of aluminum) separated by a layer of insulating material. The exposed electrode captures ions and accumulates their electric charges during signal-integration periods.

Sinha, Mahadeva↗

Fabrication and testing of large size nickel-zinc cells

The design and construction of nickel zinc cells, containing sintered nickel electrodes and asbestos coated inorganic separator materials, were outlined. Negative electrodes were prepared by a dry pressing process while various inter-separators were utilized on the positive electrodes, consisting of non-woven nylon, non-woven polypropylene, and asbestos.

Klein, M.↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2023 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. Last year’s paper reported a fault condition termed “electrode bridging,” in which silver deposits on interelectrode wetted materials, eventually bridging the electrode gap and providing an alternate conduction pathway that diminishes the silver output of the reactor. Since then, two strategies have been developed that prevent this fault from occurring: 1) increasing the frequency of polarity reversal and 2) separating the active surface of the electrode from the interelectrode wetted material. These strategies were tested independently, and in both cases, the reactor performed as expected with no occurrence of bridging for at least one crew-year equivalent of cumulative operation. Additional tests were conducted at varying levels of influent dissolved oxygen to better understand the nature of the cathode reaction and its impact on reactor performance. Results indicate that the primary cathode reaction is the reduction of dissolved oxygen, which could imply a dependence of reactor performance on dissolved oxygen concentration. However, it was found that at the typical oxygen concentrations anticipated for spacecraft processed water, the impact on silver electrolysis performance was negligible. Finally, multiphysics modelling of the reactor fluid mechanics and electrochemistry was undertaken to provide the capability to optimize the design of a future reactor prototype.

silver electrolysis↗

Silver Electrolysis for Disinfection of Spacecraft Potable Water: 2023 Update

Anodic dissolution of silver electrodes, or “silver electrolysis,” is being investigated as a means of introducing biocidal silver into potable water on exploration spacecraft. Last year’s paper reported a fault condition termed “electrode bridging,” in which silver deposits on interelectrode wetted materials, eventually bridging the electrode gap and providing an alternate conduction pathway that diminishes the silver output of the reactor. Since then, two strategies have been developed that prevent this fault from occurring: 1) increasing the frequency of polarity reversal and 2) separating the active surface of the electrode from the interelectrode wetted material. These strategies were tested independently, and in both cases, the reactor performed as expected with no occurrence of bridging for at least one crew-year equivalent of cumulative operation. Additional tests were conducted at varying levels of influent dissolved oxygen to better understand the nature of the cathode reaction and its impact on reactor performance. Results indicate that the primary cathode reaction is the reduction of dissolved oxygen, which could imply a dependence of reactor performance on dissolved oxygen concentration. However, it was found that at the typical oxygen concentrations anticipated for spacecraft processed water, the impact on silver electrolysis performance was negligible. Finally, multiphysics modelling of the reactor fluid mechanics and electrochemistry was undertaken to provide the capability to optimize the design of a future reactor prototype.

silver electrolysis↗

Method of fabricating a PbS-PbSe IR detector array

A silicon wafer is provided which does not employ individually bonded leads between the IR sensitive elements and the input stages of multiplexers. The wafer is first coated with lead selenide in a first detector array area and is thereafter coated with lead sulfide within a second detector array area. The described steps result in the direct chemical deposition of lead selenide and lead sulfide upon the silicon wafer to eliminate individual wire bonding, bumping, flip chiping, planar interconnecting methods of connecting detector array elements to silicon chip circuitry, e.g., multiplexers, to enable easy fabrication of very long arrays. The electrode structure employed, produces an increase in the electrical field gradient between the electrodes for a given volume of detector material, relative to conventional electrode configurations.

Barrett, John R.↗