Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “EXPERIMENTAL PHYSICS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Optical Comb Generation for Streak Camera Calibration for Inertial Confinement Fusion Experiments

The National Ignition Facility (NIF) at Lawrence Livermore National Laboratory (LLNL) is coming on-line to support physics experimentation for the U.S. Department of Energy (DOE) programs in Inertial Confinement Fusion (ICF) and Stockpile Stewardship (SS). Optical streak cameras are an integral part of the experimental diagnostics instrumentation at NIF. To accurately reduce streak camera data a highly accurate temporal calibration is required. This article describes a technique for simultaneously generating a precise +/- 2 ps optical marker pulse (fiducial reference) and trains of precisely timed, short-duration optical pulses (so-called “comb” pulse trains) that are suitable for the timing calibrations. These optical pulse generators are used with the LLNL optical streak cameras. They are small, portable light sources that, in the comb mode, produce a series of temporally short, uniformly spaced optical pulses, using a laser diode source. Comb generators have been produced with pulse-train repetition rates up to 10 GHz at 780 nm, and somewhat lower frequencies at 664 nm. Individual pulses can be as short as 25-ps FWHM. Signal output is via a fiber-optic connector on the front panel of the generator box. The optical signal is transported from comb generator to streak camera through multi-mode, graded-index optical fiber.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Murray J. Martin (1935–2022)

The field of nuclear data lost a pioneer with the passing of Murray Martin on March 9, 2022. Born in Regina, Canada in 1935, Murray Martin received his B.A. and M.A. in experimental physics from the University of Saskatchewan and his PhD in theoretical nuclear physics in 1962 from McMaster Univ. His thesis was entitled “A Study of the Low-Lying Excited Levels in the Even Lead Isotopes”. Additionally, he joined the NSF Data Project in 1962 in Washington, DC, and then followed that project as it moved to ORNL in 1964 as the Nuclear Data Project (NDP). Murray stayed with the NDP until his retirement in 1997 but resumed his work on a part-time basis in 2004 as a subcontractor to ORNL, which he continued until his last days.

99 GENERAL AND MISCELLANEOUS↗

An overview of how parity-violating electron scattering experiments are performed at CEBAF

Parity-violating electron-scattering experiments represent an important focus of the nuclear physics experimental program at the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab. These experiments pose significant challenges because the scattering asymmetries can be very small, of the order parts-per-million and smaller. To succeed, the properties of the electron beam such as current, position, size and energy, must be very nearly identical in the two electron-polarization spin states (parallel and anti-parallel relative to the direction of beam motion at the scattering target). This paper describes the origins of unwanted helicity-correlated beam asymmetries present on the electron beam and methods to minimize them to acceptable levels.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Status of the data acquisition, trigger, and slow control systems of the Mu2e experiment at Fermilab

The Mu2e experiment at the Fermilab will search for a coherent neutrinoless conversion of a muon into an electron in the field of an aluminum nucleus with a sensitivity improvement by a factor of 10,000 over existing limits. In this work, the Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq framework as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates several framework components — an artdaq-based DAQ, an art-based event processing, and an EPICS-based detector control system (DCS), and provides a uniform multi-user interface to its components through a web browser. Data streams from the Mu2e tracker and calorimeter are handled by the artdaq-based DAQ and processed by a one-level software trigger implemented within the art framework. Events accepted by the trigger have their data combined, post-trigger, with the separately read out data from the Mu2e Cosmic Ray Veto system. Foundation of the Mu2e DCS, EPICS – an Experimental Physics and Industrial Control System – is an open-source platform for monitoring, controlling, alarming, and archiving. A prototype of the TDAQ and the DCS systems has been built and tested over the last three years at Fermilab’s Feynman Computing Center, and now the production system installation is underway. This work presents their status and focus on the installation plans and procedures for racks, workstations, network switches, gateway computers, DAQ hardware, slow controls implementation, and testing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Room-temperature superconductivity in a carbonaceous sulfur hydride

One of the long-standing challenges in experimental physics is the observation of room-temperature superconductivity (RTSC). Recently, high temperature conventional superconductivity in hydrogen-rich materials has been reported in several systems under high pressure. The most significant discovery in reaching RTSC is the pressure-driven disproportionation of hydrogen sulfide (H 2 S) to H 3 S with a confirmed Tc of 203 kelvin at 155 gigapascals. As H 2 S readily mixes with hydrogen to form guest-host structures at lower pressures, the comparable size of methane to H 2 S should allow molecular exchange within a large assemblage of van der Waals solids that are (highly) hydrogen-rich with H 2 inclusions that are then the building blocks for novel superconducting compounds at extreme conditions. Here, we report superconductivity in a photochemically transformed carbonaceous sulfur hydride system with a maximum superconducting transition temperature of 287.7 ± 1.2 kelvin (~15° celsius) achieved at 267 ± 10 gigapascals. The superconducting state is observed over a broad pressure range from 140 to 275 gigapascals, with a dramatic upturn in Tc above 220 gigapascals. Superconductivity is established by the observation of zero resistance, magnetic susceptibility up to 190 gigapascals, and reduction of Tc under an external magnetic field up to 9 tesla, with an upper critical magnetic field of ~62 tesla based on Ginzburg–Landau (GL) model at zero temperature. The light, quantum nature of hydrogen limits structural and stoichiometric determination using x-ray scattering techniques. Raman spectroscopy is used to probe the chemical and structural transformations pre-metallization. In conclusion, the introduction of chemical tuning within our reported ternary system could be the path forward to lowering the pressure while preserving the RTSC properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Mu2e DAQ and slow control systems

The Mu2e experiment at the Fermilab Muon Campus will search for the coherent neutrinoless conversion of a muon into an electron in the feld of an aluminum nucleus with a sensitivity improvement by a factor of 10,000 over existing limits. The Mu2e Trigger and Data Acquisition System (TDAQ) uses otsdaq as the online Data Acquisition System (DAQ) solution. Developed at Fermilab, otsdaq integrates both the artdaq DAQ and the art analysis frameworks for event transfer, fltering, and processing. otsdaq is an online DAQ software suite with a focus on fexibility and scalability and provides a multiuser, web-based, interface accessible through a web browser. The data stream from the detector subsystems is read by a software flter algorithm that selects events which are combined with the data fux coming from a Cosmic Ray Veto System. The Detector Control System (DCS) has been developed using the Experimental Physics and Industrial Control System (EPICS) open source platform for monitoring, controlling, alarming, and archiving. The DCS System has been integrated into otsdaq. A prototype of the TDAQ and the DCS systems has been built at Fermilab’s Feynman Computing Center. In this paper, we report on the progress of the integration of this prototype in the online otsdaq software.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Caborane beam from ITEP Bernas ion source for semiconductor implanters

A joint research and development of steady state intense boron ion sources for hundreds of electron-volt ion implanters has been in progress for the past 5 years. The difficulties of extraction and transportation of low energy boron beams can be solved by implanting clusters of boron atoms. In Institute for Theoretical and Experimental Physics (ITEP) the Bernas ion source successfully generated the beam of decaborane ions. The carborane (C{sub 2}B{sub 10}H{sub 12}) ion beam is more attractive material due to its better thermal stability. The results of carborane ion beam generation are presented. The result of the beam implantation into the silicon wafer is presented as well.

43 PARTICLE ACCELERATORS↗

ITEP MEVVA ion beam for rhenium silicide production

The rhenium silicides are very attractive materials for semiconductor industry. In the Institute for Theoretical and Experimental Physics (ITEP) at the ion source test bench the research program of rhenium silicide production by ion beam implantation are going on. The investigation of silicon wafer after implantation of rhenium ion beam with different energy and with different total dose were carried out by secondary ions mass spectrometry, energy-dispersive x-ray microanalysis, and x-ray diffraction analysis. The first promising results of rhenium silicide film production by high intensity ion beam implantation are presented.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Portable emittance measurement device

In Institute for Theoretical and Experimental Physics (ITEP) the portable emittance measurements device is developed. It provides emittance measurements both with ''pepper-pot'' and ''two slits'' methods. Depending on the method of measurements, either slits or pepper-pot mask with scintillator are mounted on the two activators and are installed in two standard Balzer's cross chamber with CF-100 flanges. To match the angle resolution for measured beam, the length of the stainless steel pipe between two crosses changes is adjusted. The description of the device and results of emittance measurements at the ITEP ion source test bench are presented.

43 PARTICLE ACCELERATORS↗

PROTON MICROSCOPY AT FAIR

Proton radiography was invented in the 1990's at Los Alamos National Laboratory (LANL) as a diagnostic to study dynamic material properties under extreme pressures, strain and strain rate. Since this time hundreds of dynamic proton radiography experiments have been performed at LANL and a facility has been commissioned at the Institute for Theoretical and Experimental Physics (ITEP) in Russia for similar applications in dynamic material studies. Recently an international effort has investigated a new proton radiography capability for the study of dynamic material properties at the Facility for Anti-proton and Ion Research (FAIR) located in Darmstadt, Germany. This new Proton microscope for FAIR(PRIOR) will provide radiographic imaging of dynamic systems with unprecedented spatial, temporal and density resolution, resulting in a window for understanding dynamic material properties at new length scales. It is also proposed to install the PRIOR system at the GSI Helmholtzzentrum fuer Schwerionenforschung before installation at FAIR for dynamic experiments with different drivers including high explosives, pulsed power and lasers. The design of the proton microscope and expected radiographic performance is presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

The rotating wall machine: A device to study ideal and resistive magnetohydrodynamic stability under variable boundary conditions

The rotating wall machine, a basic plasma physics experimental facility, has been constructed to study the role of electromagnetic boundary conditions on current-driven ideal and resistive magnetohydrodynamic instabilities, including differentially rotating conducting walls. The device, a screw pinch magnetic geometry with line-tied ends, is described. The plasma is generated by an array of 19 plasma guns that not only produce high density plasmas but can also be independently biased to allow spatial and temporal control of the current profile. The design and mechanical performance of the rotating wall as well as diagnostic capabilities and internal probes are discussed. Measurements from typical quiescent discharges show the plasma to be high {beta} ({<=}p>2{mu}{sub 0}/B{sub z}{sup 2}), flowing, and well collimated. Internal probe measurements show that the plasma current profile can be controlled by the plasma gun array.

42 ENGINEERING↗

Ultra-broadband infrared pump-probe spectroscopy using synchrotron radiation and a tuneable pump

Synchrotron infrared sources have become popular mainly because of their excellent broadband brilliance, which enables spectroscopically resolved spatial-mapping of stationary objects at the diffraction limit. In this article we focus on an often-neglected further advantage of such sources - their unique time-structure - to bring such broadband spectroscopy to the time domain, for studying dynamic phenomenon down to the 100 ps limit. We describe the ultra-broadband (12.5 to 1.1 {mu}m) Fourier transform pump-probe setup, for condensed matter transmission- and reflection-spectroscopy, installed at the X01DC infrared beam-line of the Swiss Light Source (SLS). The optical pump consists of a widely tuneable 100 ps 1 kHz laser system, covering 94% of the 16 to 1.1 {mu}m range. A thorough description of the system is given, including (i) the vector-modulator providing purely electronic tuning of the pump-probe overlap up to 1 ms with sub-ps time resolution, (ii) the 500 MHz data acquisition system interfaced with the experimental physics and industrial control system (EPICS) based SLS control system for consecutive pulse sampling, and (iii) the step-scan time-slice Fourier transform scheme for simultaneous recording of the dual-channel pumped, un-pumped, and difference spectra. The typical signal/noise ratio of a single interferogram in a 100 ps time slice is 300 (measured during one single 140 s TopUp period). This signal/noise ratio is comparable to that of existing gated Globar pump-probe Fourier transform spectroscopy, but brings up to four orders of magnitude better time resolution. To showcase the utility of broadband pump-probe spectroscopy, we investigate a Ge-on-Si material system similar to that in which optically pumped direct-gap lasing was recently reported. We show that the mid-infrared reflection-spectra can be used to determine the optically injected carrier density, while the mid- and near-infrared transmission-spectra can be used to separate the strong pump-induced absorption and inversion processes present at the direct-gap energy.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Rhenium ion beam for implantation into semiconductors

At the ion source test bench in Institute for Theoretical and Experimental Physics the program of ion source development for semiconductor industry is in progress. In framework of the program the Metal Vapor Vacuum Arc ion source for germanium and rhenium ion beam generation was developed and investigated. It was shown that at special conditions of ion beam implantation it is possible to fabricate not only homogenous layers of rhenium silicides solid solutions but also clusters of this compound with properties of quantum dots. At the present moment the compound is very interesting for semiconductor industry, especially for nanoelectronics and nanophotonics, but there is no very developed technology for production of nanostructures (for example quantum sized structures) with required parameters. The results of materials synthesis and exploration are presented.

36 MATERIALS SCIENCE↗

Concept, implementation and commissioning of the automation system for the accelerator module test facility AMTF

The European XFEL project launched on June 5, 2007 will require about 103 accelerator modules as a main part of the XFEL linear accelerator. All superconducting components constituting the accelerator module like cavities and magnets have to be tested before the assembly. For the tests of the individual cavities and the complete modules an XFEL Accelerator Module Test Facility (AMTF) has been erected at DESY. The process control system EPICS (Experimental Physics and Industrial Control System) is used to control and operate the cryogenic plant and all its subcomponents. A complementary component of EPICS is the Open Source software suit CSS (Control System Studio). CSS is an integrated engineering, maintenance and operating tool for EPICS. CSS enables local and remote operating and monitoring of the complete system and thus represents the human machine interface. More than 250 PROFIBUS nodes work at the accelerator module test facility. DESY installed an extensive diagnostic and condition monitoring system. With these diagnostic tools it is possible to examine the correct installation and configuration of all PROFIBUS nodes in real time. The condition monitoring system based on FDT/DTM technology shows the state of the PROFIBUS devices at a glance. This information can be used for preventive maintenance which is mandatory for continuous operation of the AMTF facility. The poster will describe all steps form engineering to implementation and commissioning.

43 PARTICLE ACCELERATORS↗

Characterization of micro-contact resistance between a gold nanocrystalline line and a tungsten electrode probe in interconnect fatigue testing

An electromechanically-coupled micro-contact resistance measurement system is built to mimic the contact process during fatigue testing of nanoscale-thickness interconnects using multiple probe methods. The design combines an optical microscope, high-resolution electronic balance, and micromanipulator-controlled electric probe, and is coupled with electrical measurements to investigate microscale contact physics. Experimental measurements are performed to characterize the contact resistance response of the gold nanocrystalline pad of a 35-nm-thick interconnect under mechanical force applied by a tungsten electrode probe. Location of a stable region for the contact resistance and the critical contact force provides better understanding of micro-contact behavior relative to the effects of the contact force and the nature of the contact surface. Increasing contact temperature leads to reduced contact resistance, softens the pad material, and modifies the contact surface. The stability of both contact resistance and interconnect resistance is studied under increasing contact force. Major fluctuations emerge when the contact force is less than the critical contact force, which shows that temporal contact resistance will affect interconnect resistance measurement accuracy, even when using the four-wire method. This performance is demonstrated experimentally by heating the Au line locally with a laser beam. Finally, the contact resistances are calculated using the LET (Li–Etsion–Talke) model together with combined Holm and Sharvin theory under various contact forces. Good agreement between the results is obtained. This research provides a way to measure change in interconnect line resistance directly under a stable contact resistance regime with a two-wire method that will greatly reduce the experimental costs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Mathematical, theoretical and experimental confirmations of IRS and IBS by R.M. Santilli

The objective of present work is to put forward the Santilli’s experimental, physical and mathematical conception of IsoRedShift (IRS), IsoBlueShift (IBS) and NoIsoShift (NIS). Santilli has carried out a step-by step isotopic lifting of the physical laws of special relativity resulting in a new theory today specifically known Santilli isorelativity. In his 1991 hypothesis Santilli established the requirement to realize the light as electromagnetic waves propagating within a universal substratum. Furthermore Santilli has carried out a step-by step isotopic lifting of the physical laws of special relativity resulting in a new theory today specifically known Santilli isorelativity.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Implementation of EPICS based vacuum control system for variable energy cyclotron centre, Kolkata

The vacuum system of the Room Temperature (K = 130) Cyclotron of Variable Energy Cyclotron Centre is comprised of vacuum systems of main machine and Beam Transport System. The vacuum control system is upgraded to a PLC based Automated system from the initial relay based Manual system. The supervisory control of the vacuum system is implemented in Experimental Physics and Industrial Control System (EPICS). An EPICS embedded ARM based vacuum gauge controller is developed to mitigate the requirement of vendor specific gauge controller for gauges and also for seamless integration of the gauge controllers with the control system. A set of MS-Windows ActiveX components with embedded EPICS Channel Access interface are developed to build operator interfaces with less complex programming and to incorporate typical Windows feature, e.g., user authentication, file handling, better fonts, colors, mouse actions etc. into the operator interfaces. The control parameters, monitoring parameters, and system interlocks of the system are archived in MySQL based EPICS MySQL Archiver developed indigenously. In this paper, we describe the architecture, the implementation details, and the performance of the system.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface modification of ferritic steels using MEVVA and duoplasmatron ion sources

Metal Vapor Vacuum Arc (MEVVA) ion source (IS) is a unique tool for production of high intensity metal ion beam that can be used for material surface modification. From the other hand, the duoplasmatron ion source provides the high intensity gas ion beams. The MEVVA and duoplasmatron IS developed in Institute for Theoretical and Experimental Physics were used for the reactor steel surface modification experiments. Response of ferritic-martensitic steel specimens on titanium and nitrogen ions implantation and consequent vacuum annealing was investigated. Increase in microhardness of near surface region of irradiated specimens was observed. Local chemical analysis shows atom mixing and redistribution in the implanted layer followed with formation of ultrafine precipitates after annealing.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗