SU-F-BRB-01: How Effective Is Abdominal Compression at Reducing Lung Motion? An Analysis Using Deformable Image Registration Within Different Sub-Regions of the Lung

Purpose: To investigate the effectiveness of employing abdominal compression (AC) in reducing motion for the target region and sub-regions of the lung as part of the planning process for radiation therapy. Methods: Fourteen patients with early lung cancer were scanned with 4DCT and it was determined that target motion exceeded our institutional limit of > 8 mm motion and received a repeat 4DCT with AC. For each 4DCT, deformable image registration (DIR) was used to map the max inhale to the max exhale phase to determine the deformation vector fields (DVF). DIR was performed with Morphons and Demons algorithms. The mean DVF was used to represent that sub-region for each patient. The magnitudes of the mean DVF were quantified for the target and 12 sub-regions in the AP, LR SI directions. The sub-regions were contoured on each lung as (add prefix R or L for lung): Upper-Anterior (UA), Upper-Posterior (UP), Mid-Anterior (MA), Mid-Posterior (MP), Lower-Anterior (LA) and Lower-Posterior (LP). Results: The min/max SI motion for the target on the uncompressed 4DCT was 8mm/24.5 mm. The magnitude of decrease in SI was greatest in the RLP region (3.7±4.0mm) followed by target region (3.3±2.2mm) and finally the LLP region (3.0±3.5mm). The magnitude of decrease in 3D vector followed the same trend; RLP (3.5±2.2mm) then GTV (3.5±2.6mm) then LLP (2.7±3.8mm). 79% of the cases had a SI decrease of >12.5%, 43% had a SI decrease of >25% and 21% had a SI decrease of >50% as compared to the motion on the uncompressed 4DCT. Conclusion: AC is useful in reducing motion with the largest decreases observed in the lower posterior regions of the lungs. However, it should be noted that AC will not greatly decrease motion for all cases as 21% of cases did not reduce SI motion more than 12.5% of initial motion.

60 APPLIED LIFE SCIENCES↗

SU-F-303-10: Impact of Visual Biofeedback On Respiratory Reproducibility in 4DMRI

Purpose: Precise radiation therapy (RT) for abdominal lesions is complicated by respiratory motion and suboptimal soft tissue contrast in 4DCT. 4DMRI offers improved contrast. However, long scan times and irregular breathing patterns can be limiting. To address this, we introduced visual biofeedback (VBF) into 4DMRI. Methods: Eight healthy volunteers were consented to an IRB-approved protocol. Prospective respiratory-triggered, T2-weighted coronal 4DMRIs were acquired on an open 1.0T MR- SIM. VBF was integrated using an MR-compatible interactive breath-hold control system. Subjects visually monitored their breathing patterns to stay within pre-determined tolerances. 4DMRIs were acquired with and without VBF for 2–8 phase acquisitions. Normalized respiratory waveforms were evaluated for scan time, duty cycle (programmed/acquisition time), breathing period, end-inhale (EI) amplitude, and breathing variability (coefficient of variation, EI-COV). B-spline-based deformable image registration propagated contours from end-exhale (EE) to EI phases. Respiration-induced liver motion was calculated via centroid analysis and compared. Results: Incorporating VBF reduced 2-phase acquisition time (4.7±0.6 and 5.6±1.4 minutes with and without VBF, respectively) while reducing the amplitude EI-COV by 53.0±8.1%. On average, incorporating VBF reduced 8-phase 4DMRI acquisition times by 1.7±1.2 minutes and EI-COVs by 46.0±15.8%. Using VBF yielded higher duty cycles than free breathing (34.7% versus 28.3%, respectively). 4DMRI acquisition time was reduced for the cohort with VBF despite breathing rate remaining similar (10.5±4.0 with vs. 10.6±3.3 BPM without). Respiratory waveforms showed higher EI amplitude with VBF (0.84±0.05 a.u.) as compared to 0.72±0.06 a.u. without. This translated to differences in liver excursions, where superior-inferior, anterior-posterior, and left-right EE-EI displacements were 14.3±3.6, 4.8±2.1, and 1.6±1.0 mm, respectively, with VBF compared to 13.0±6.2, 3.8±2.4, and 1.2±1.4 mm without. Conclusion: Incorporating VBF system into 4DMRI substantially reduced acquisition time and breathing variability. While VBF reduced liver motion variability, differences in excursion were observed, suggesting that implementation will be required throughout the RT workflow. Research supported in part by a grant from Philips HealthCare (Best, Netherlands) and an equipment evaluation agreement with MedSpira.

60 APPLIED LIFE SCIENCES↗

MO-FG-204-05: Evaluation of a Novel Algorithm for Improved 4DCT Resolution

Purpose: Accurate tumor motion characterization is critical for increasing the therapeutic ratio of radiation therapy. To accommodate the divergent fan-beam geometry of the scanner, the current 4D-CT algorithm utilizes a larger temporal window to ensure that pixel values are valid throughout the entire FOV. To minimize the impact on temporal resolution, a cos{sup 2} weighting is employed. We propose a novel exponential weighting (“exponential”) 4DCT reconstruction algorithm that has a sharper slope and provides a more optimal temporal resolution. Methods: A respiratory motion platform translated a lung-mimicking Styrofoam slab with several high and low-contrast inserts 2 cm in the superior-inferior direction. Breathing rates (10–15 bpm) and couch pitch (0.06–0.1 A.U.) were varied to assess interplay between parameters. Multi-slice helical 4DCTs were acquired with 0.5 sec gantry rotation and data were reconstructed with cos{sup 2} and exponential weighting. Mean and standard deviation were calculated via region of interest analysis. Intensity profiles evaluated object boundaries. Retrospective raw data reconstructions were performed for both 4DCT algorithms for 3 liver and lung cancer patients. Image quality (temporal blurring/sharpness) and subtraction images were compared between reconstructions. Results: In the phantom, profile analysis revealed that sharper boundaries were obtained with exponential reconstructions at transitioning breathing phases (i.e. mid-inhale or mid-exhale). Reductions in full-width half maximum were ∼1 mm in the superior-inferior direction and appreciable sharpness could be observed in difference maps. This reduction also yielded a slight reduction in target volume between reconstruction algorithms. For patient cases, coronal views showed less blurring at object boundaries and local intensity differences near the tumor and diaphragm with exponential weighted reconstruction. Conclusion: Exponential weighted 4DCT offers potential for improving image sharpness in 4DCT. Comparisons with true object extent using static CTs of varied phantom positions are necessary to confirm these findings. Future work with additional patient cases is warranted. Research partially sponsored by Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-02: 4D Optimized Treatment Planning for Actively Scanned Proton Therapy Delivered to Moving Target Volume

Purpose: To develop a 4D treatment optimization approach for Pencil Beam Scanned (PBS) proton therapy that includes breathing variability. Method: PBS proton therapy delivers a pattern of proton pencil beams (PBs), distributed to cover the target volume and optimized such as to achieve a homogenous dose distribution across the target. In this work, this optimization step has been enhanced to include advanced 4D dose calculations of liver tumors based on motion extracted from either 4D-CT (representing a single and averaged respiratory cycle) or 4D-CT(MRI) (including breathing variability). The 4D dose calculation is performed per PB on deforming dose grid, and according to the timestamp of each PB, a displacement due to patient’s motion and a change in radiological depth.Three different treatment fields have been optimized in 3D on the end-exhale phase of a 4D-CT liver data set (3D-opt) and then in 4D using the motion extracted from either 4D-CT or 4D-CT(MRI) using deformable image registration. All plans were calculated directly on the PTV without the use of an ITV. The delivery characteristics of the PSI Gantry 2 have been assumed for all calculations. Results: Dose inhomogeneities (D5-D95) in the CTV for the 3D optimized plans recalculated under conditions of variable motion were increased by on average 19.8% compared to the static case. These differences could be reduced by 4D-CT based 4D optimization to 10.5% and by 4D-CT(MRI) based optimization to only 2.3% of the static value. Liver V25 increased by less than 1% using 4D optimization. Conclusion: 4D optimized PBS treatment plans taking into account breathing variability provide for significantly improved robustness against motion and motion variability than those based on 4D-CT alone, and may negate the need of motion specific target expansions. Swiss National Fund Grant (320030-1493942-1)

60 APPLIED LIFE SCIENCES↗

TU-G-BRA-02: Can We Extract Lung Function Directly From 4D-CT Without Deformable Image Registration?

Purpose: Dynamic CT ventilation imaging (CT-VI) visualizes air volume changes in the lung by evaluating breathing-induced lung motion using deformable image registration (DIR). Dynamic CT-VI could enable functionally adaptive lung cancer radiation therapy, but its sensitivity to DIR parameters poses challenges for validation. We hypothesize that a direct metric using CT parameters derived from Hounsfield units (HU) alone can provide similar ventilation images without DIR. We compare the accuracy of Direct and Dynamic CT-VIs versus positron emission tomography (PET) images of inhaled {sup 68}Ga-labelled nanoparticles (‘Galligas’). Methods: 25 patients with lung cancer underwent Galligas 4D-PET/CT scans prior to radiation therapy. For each patient we produced three CT- VIs. (i) Our novel method, Direct CT-VI, models blood-gas exchange as the product of air and tissue density at each lung voxel based on time-averaged 4D-CT HU values. Dynamic CT-VIs were produced by evaluating: (ii) regional HU changes, and (iii) regional volume changes between the exhale and inhale 4D-CT phase images using a validated B-spline DIR method. We assessed the accuracy of each CT-VI by computing the voxel-wise Spearman correlation with free-breathing Galligas PET, and also performed a visual analysis. Results: Surprisingly, Direct CT-VIs exhibited better global correlation with Galligas PET than either of the dynamic CT-VIs. The (mean ± SD) correlations were (0.55 ± 0.16), (0.41 ± 0.22) and (0.29 ± 0.27) for Direct, Dynamic HU-based and Dynamic volume-based CT-VIs respectively. Visual comparison of Direct CT-VI to PET demonstrated similarity for emphysema defects and ventral-to-dorsal gradients, but inability to identify decreased ventilation distal to tumor-obstruction. Conclusion: Our data supports the hypothesis that Direct CT-VIs are as accurate as Dynamic CT-VIs in terms of global correlation with Galligas PET. Visual analysis, however, demonstrated that different CT-VI algorithms might have varying accuracy depending on the underlying cause of ventilation abnormality. This research was supported by a National Health and Medical Research Council (NHMRC) Australia Fellowship, an Cancer Institute New South Wales Early Career Fellowship 13-ECF-1/15 and NHMRC scholarship APP1038399. No commercial funding was received for this work.

60 APPLIED LIFE SCIENCES↗

TU-F-CAMPUS-J-03: Elasticity Functions Based On 4DCT Images to Predict Tumor and Normal Tissue Response to Radiation for Patients with Lung Cancers

Purpose: To investigate radiotherapy outcomes by incorporating 4DCT-based physiological and tumor elasticity functions for lung cancer patients. Methods: 4DCT images were acquired from 28 lung SBRT patients before radiation treatment. Deformable image registration (DIR) was performed from the end-inhale to the end-exhale using a B-Spline-based algorithm (Elastix, an open source software package). The resultant displacement vector fields (DVFs) were used to calculate a relative Jacobian function (RV) for each patient. The computed functions in the lung and tumor regions represent lung ventilation and tumor elasticity properties, respectively. The 28 patients were divided into two groups: 16 with two-year tumor local control (LC) and 12 with local failure (LF). The ventilation and elasticity related RV functions were calculated for each of these patients. Results: The LF patients have larger RV values than the LC patients. The mean RV value in the lung region was 1.15 (±0.67) for the LF patients, higher than 1.06 (±0.59) for the LC patients. In the tumor region, the elasticity-related RV values are 1.2 (±0.97) and 0.86 (±0.64) for the LF and LC patients, respectively. Among the 16 LC patients, 3 have the mean RV values greater than 1.0 in the tumors. These tumors were located near the diaphragm, where the displacements are relatively large.. RV functions calculated in the tumor were better correlated with treatment outcomes than those calculated in the lung. Conclusion: The ventilation and elasticity-related RV functions in the lung and tumor regions were calculated from 4DCT image and the resultant values showed differences between the LC and LF patients. Further investigation of the impact of the displacements on the computed RV is warranted. Results suggest that the RV images might be useful for evaluation of treatment outcome for lung cancer patients.

60 APPLIED LIFE SCIENCES↗

WE-AB-BRA-11: Development of Physiological-Based Virtual Thorax Phantoms for Evaluation of Deformable Image Registration

Purpose: To develop a methodology of constructing physiological-based virtual thorax phantom based on hyperpolarized (HP) gas tagging MRI for evaluating deformable image registration (DIR). Methods: Three healthy subjects were imaged at both the end-of-inhalation (EOI) and the end-of-exhalation (EOE) phases using a high-resolution (2.5mm isovoxel) 3D proton MRI, as well as a hybrid MRI which combines HP gas tagging MRI and a low-resolution (4.5mm isovoxel) proton MRI. A sparse tagging displacement vector field (tDVF) was derived from the HP gas tagging MRI by tracking the displacement of tagging grids between EOI and EOE. Using the tDVF and the high-resolution MR images, we determined the motion model of the entire thorax in the following two steps: 1) the DVF inside of lungs was estimated based on the sparse tDVF using a novel multi-step natural neighbor interpolation method; 2) the DVF outside of lungs was estimated from the DIR between the EOI and EOE images (Velocity AI). The derived motion model was then applied to the high-resolution EOI image to create a deformed EOE image, forming the virtual phantom where the motion model provides the ground truth of deformation. Five DIR methods were evaluated using the developed virtual phantom. Errors in DVF magnitude (Em) and angle (Ea) were determined and compared for each DIR method. Results: Among the five DIR methods, free form deformation produced DVF results that are most closely resembling the ground truth (Em=1.04mm, Ea=6.63°). The two DIR methods based on B-spline produced comparable results (Em=2.04mm, Ea=13.66°; and Em =2.62mm, Ea=17.67°), and the two optical-flow methods produced least accurate results (Em=7.8mm; Ea=53.04°; Em=4.45mm, Ea=31.02°). Conclusion: A methodology for constructing physiological-based virtual thorax phantom based on HP gas tagging MRI has been developed. Initial evaluation demonstrated its potential as an effective tool for robust evaluation of DIR in the lung.

60 APPLIED LIFE SCIENCES↗

Realistic respiratory motion margins for external beam partial breast irradiation

Purpose: Respiratory margins for partial breast irradiation (PBI) have been largely based on geometric observations, which may overestimate the margin required for dosimetric coverage. In this study, dosimetric population-based respiratory margins and margin formulas for external beam partial breast irradiation are determined. Methods: Volunteer respiratory data and anterior–posterior (AP) dose profiles from clinical treatment plans of 28 3D conformal radiotherapy (3DCRT) PBI patient plans were used to determine population-based respiratory margins. The peak-to-peak amplitudes (A) of realistic respiratory motion data from healthy volunteers were scaled from A = 1 to 10 mm to create respiratory motion probability density functions. Dose profiles were convolved with the respiratory probability density functions to produce blurred dose profiles accounting for respiratory motion. The required margins were found by measuring the distance between the simulated treatment and original dose profiles at the 95% isodose level. Results: The symmetric dosimetric respiratory margins to cover 90%, 95%, and 100% of the simulated treatment population were 1.5, 2, and 4 mm, respectively. With patient set up at end exhale, the required margins were larger in the anterior direction than the posterior. For respiratory amplitudes less than 5 mm, the population-based margins can be expressed as a fraction of the extent of respiratory motion. The derived formulas in the anterior/posterior directions for 90%, 95%, and 100% simulated population coverage were 0.45A/0.25A, 0.50A/0.30A, and 0.70A/0.40A. The differences in formulas for different population coverage criteria demonstrate that respiratory trace shape and baseline drift characteristics affect individual respiratory margins even for the same average peak-to-peak amplitude. Conclusions: A methodology for determining population-based respiratory margins using real respiratory motion patterns and dose profiles in the AP direction was described. It was found that the currently used respiratory margin of 5 mm in partial breast irradiation may be overly conservative for many 3DCRT PBI patients. Amplitude alone was found to be insufficient to determine patient-specific margins: individual respiratory trace shape and baseline drift both contributed to the dosimetric target coverage. With respiratory coaching, individualized respiratory margins smaller than the full extent of motion could reduce planning target volumes while ensuring adequate coverage under respiratory motion.

60 APPLIED LIFE SCIENCES↗

SU-F-I-11: Software Development for 4D-CBCT Research of Real-Time-Image Gated Spot Scanning Proton Therapy

Purpose: To acquire correct information for inside the body in patient positioning of Real-time-image Gated spot scanning Proton Therapy (RGPT), utilization of tomographic image at exhale phase of patient respiration obtained from 4-dimensional Cone beam CT (4D-CBCT) has been desired. We developed software named “Image Analysis Platform” for 4D-CBCT researches which has technique to segment projection-images based on 3D marker position in the body. The 3D marker position can be obtained by using two axes CBCT system at Hokkaido University Hospital Proton Therapy Center. Performance verification of the software was implemented. Methods: The software calculates 3D marker position retrospectively by using matching positions on pair projection-images obtained by two axes fluoroscopy mode of CBCT system. Log data of 3D marker tracking are outputted after the tracking. By linking the Log data and gantry-angle file of projection-image, all projection-images are equally segmented to spatial five-phases according to marker 3D position of SI direction and saved to specified phase folder. Segmented projection-images are used for CBCT reconstruction of each phase. As performance verification of the software, test of segmented projection-images was implemented for sample CT phantom (Catphan) image acquired by two axes fluoroscopy mode of CBCT. Dummy marker was added on the images. Motion of the marker was modeled to move in 3D space. Motion type of marker is sin4 wave function has amplitude 10.0 mm/5.0 mm/0 mm, cycle 4 s/4 s/0 s for SI/AP/RL direction. Results: The marker was tracked within 0.58 mm accuracy in 3D for all images, and it was confirmed that all projection-images were segmented and saved to each phase folder correctly. Conclusion: We developed software for 4D-CBCT research which can segment projection-image based on 3D marker position. It will be helpful to create high quality of 4D-CBCT reconstruction image for RGPT.

60 APPLIED LIFE SCIENCES↗

SU-F-J-116: Clinical Experience-Based Verification and Improvement of a 4DCT Program

Purpose: To demonstrate the role of continuous improvement fulfilled by the Medical Physicist in clinical 4DCT and CBCT scanning. Methods: Lung (SABR and Standard) patients’ 4D respiratory motion and image data were reviewed over a 3, 6 and 12 month period following commissioning testing. By identifying trends of clinically relevant parameters and respiratory motions, variables were tested with a programmable motion phantom and assessed. Patient traces were imported to a motion phantom and 4DCT and CBCT imaging were performed. Cos6 surrogate and sup-inf motion was also programmed into the phantom to simulate the long exhale of patients for image contrast tests. Results: Patient surrogate motion amplitudes were 9.9+5.2mm (3–35) at 18+6bpm (6–30). Expiration/Inspiration time ratios of 1.4+0.5second (0.6–2.9) showed image contrast effects evident in the AveCT and 3DCBCT images. Small differences were found for patients with multiple 4DCT data sets. Patient motion assessments were simulated and verified with the phantom within 2mm. Initial image reviews to check for reconstructed artefacts and data loss identified a small number of patients with irregularities in the automatic placement of inspiration and expiration points. Conclusion: The Physicist’s involvement in the continuous improvements of a clinically commissioned technique, processes and workflows continues beyond the commissioning stage of a project. Our experience with our clinical 4DCT program shows that Physics presence is required at the clinical 4DCT scan to assist with technical aspects of the scan and also for clinical image quality assessment prior to voluming. The results of this work enabled the sharing of information from the Medical Physics group with the Radiation Oncologists and Radiation Therapists. This results in an improved awareness of clinical patient respiration variables and how they may affect 4D simulation images and also may also affect the treatment verification images.

60 APPLIED LIFE SCIENCES↗

SU-F-J-132: Evaluation of CTV-To-PTV Expansion for Whole Breast Radiotherapy

Purpose: The current standard CTV-to-PTV expansion for whole breast radiotherapy (WBRT) is 7mm, as recommended by RTOG-1005.This expansion is derived from the uncertainty due to patient positioning (±5mm) and respiratory motion (±5mm). We evaluated the expansion needed for respiratory motion uncertainty using 4DCT. After determining the appropriate expansion margins, RT plans were generated to evaluate the reduction in heart and lung dose. Methods: 4DCT images were acquired during treatment simulation and retrospectively analyzed for 34 WBRT patients. Breast CTVs were contoured on the maximum inhale and exhale phase. Breast CTV displacement was measured in the L-R, A-P, and SUP-INF directions using rigid registration between phase images. Averaging over the 34 patients, we determined the margin due to respiratory motion. Plans were generated for 10 left-sided cases comparing the new expansion with the 7mm PTV expansion. Results: The results for respiratory motion uncertainty are shown in Table 1. Drawing on previous work by White et al at Princess Margaret Hospital (1) (see supporting document for reference) which studied the uncertainty due to patient positioning, we concluded that, in total, a 5mm expansion was sufficient. The results for our suggested PTV margin are shown in Table 2, combining the patient positioning results from White et al with our respiratory motion results. The planning results demonstrating the heart and lung dose differences in the 5mm CTV-to-PTV expanded plan compared to the 7mm plan are shown in Table 3. Conclusion: Our work evaluating the expansion needed for respiratory motion along with previous work evaluating the expansion needed for setup uncertainty shows that a CTV-to-PTV expansion of 5mm is acceptable and conservative. By reducing the PTV expansion, significant dose reduction to the heart and lung are achievable.

60 APPLIED LIFE SCIENCES↗

SU-F-J-137: Intrafractional Change of the Relationship Between Internal Fiducials and External Breathing Signal in Pancreatic Cancer Stereotactic Body Radiation Therapy

Purpose: The use of respiratory gating for management of breathing motion during stereotactic body radiation therapy (SBRT) relies on a consistent relationship between the breathing signal and the actual position of the internal target. This relationship was investigated in patients treated for pancreatic cancer. Methods: Four patients with pancreatic cancer undergoing SBRT that had implanted fiducials in the tumor were included in this study. Treatment plans were generated based on the exhale phases (30–70%) from the pre-treatment 4DCT. The margin between the internal target volume (ITV) and the planning target volume was three mm. After patient setup using cone-beam CT, simultaneous fluoroscopic imaging and breathing motion monitoring were used during at least three breathing cycles to verify the fiducial position and to optimize the gating window. After treatment, fluoroscopic images were acquired for verification purposes and exported for retrospective analyses. Fiducial positions were determined using a template-matching algorithm. For each dataset, we established a linear relationship between the fiducial position and the anterior-posterior (AP) breathing signal. The relationships before and after treatment were compared and the dose distribution impact evaluated. Results: Seven pre- and post-treatment fluoroscopic pairs were available for fiducial position analyses in the superior-inferior (SI) and left-right (LR) directions, and five in the AP direction. Time between image acquisitions was typically six to eight minutes. An average absolute change of 1.2±0.7 mm (range: 0.1–1.7) of the SI fiducial position relative to the external signal was found. Corresponding numbers for the LR and AP fiducial positions were 0.9±1.0 mm (range: 0.2–3.0) and 0.5±0.4 mm (range: 0.2–1.2), respectively. The dose distribution impact was small in both the ITV and organs-at-risk. Conclusion: The relationship change between fiducial position and external breathing signal has been observed to be about 1 mm in four pancreas SBRT patients, leading to small dose distribution impact. Pettersson and Cervino are funded by a Varian Medical Systems grant.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-05: Clinical Impact of MLC Tracking for Lung SABR

Purpose: The objective of this study was to investigate the dosimetric benefits of multi-leaf collimator (MLC) tracking for lung SABR treatments in end-to-end clinically realistic planning and delivery scenarios. Methods: The clinical benefits of MLC tracking were assessed using previously delivered treatment plans and physical experiments. The 10 most recent single lesion lung SABR patients were re-planned following a 4D-GTV-based real-time adaptive protocol (PTV defined as the end-of-exhalation GTV plus 5.0 mm margins). The plans were delivered on a Trilogy Varian linac. Electromagnetic transponders (Calypso, Varian Medical Systems, USA) were embedded into a programmable moving phantom (HexaMotion platform) tracked with the Varian Calypso system. For each physical experiment, the MLC positions were collected and used as input for dose reconstruction. For both planned and physical experiments, the OAR dose metrics from the conventional and real-time adaptive SABR plans (Mean Lung Dose (MLD), V20 for lung, and near-maximum dose (D2%) for spine and heart) were statistically compared. The Wilcoxon test was used to compare plan and physical experiment dose metrics. Results: While maintaining target coverage, percentage reductions in dose metrics to the OARs were observed for both planned and physical experiments. Comparing the two plans showed MLD percentage reduction (MLDr) of 25.4% (absolute differences of 1.41 Gy) and 28.9% (1.29%) for the V20r. D2% percentage reduction for spine and heart were respectively 27.9% (0.3 Gy) and 20.2% (0.3 Gy). For the physical experiments, MLDr was 23.9% (1.3 Gy), and V20r 37.4% (1.6%). D2% reduction for spine and heart were respectively 27.3% (0.3 Gy) and 19.6% (0.3 Gy). For both plans and physical experiments, significant OAR dose differences (p<0.05) were found between the conventional SABR and real-time adaptive plans. Conclusion: Application of MLC tracking for lung SABR patients has the potential to reduce the dose to OARs during radiation therapy.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP1-14: Respiratory Motion Tracking Using Kinect V2

Purpose: Investigate capability and accuracy of Kinect v2 camera for tracking respiratory motion to use as a tool during 4DCT or in combination with motion management during radiotherapy treatments. Methods: Utilizing the depth sensor on the Kinect as well as code written in C#, the respiratory motion of a patient was tracked by recording the depth (distance) values obtained at several points on the patient. Respiratory traces were also obtained using Varian’s RPM system, which traces the movement of a propriety marker placed on the patient’s abdomen, as well as an Anzai belt, which utilizes a pressure sensor to track respiratory motion. With the Kinect mounted 60 cm above the patient and pointing straight down, 11 breathing cycles were recorded with each system simultaneously. Relative displacement values during this time period were saved to file. While RPM and the Kinect give displacement values in distance units, the Anzai system has arbitrary units. As such, displacement for all three are displayed relative to the maximum value for the time interval from that system. Additional analysis was performed between RPM and Kinect for absolute displacement values. Results: Analysis of the data from all three systems indicates the relative motion obtained from the Kinect is both accurate and in sync with the data from RPM and Anzai. The absolute displacement data from RPM and Kinect show similar displacement values throughout the acquisition except for the depth obtained from the Kinect during maximum exhalation (largest distance from Kinect). Conclusion: By simply utilizing the depth data of specific points on a patient obtained from the Kinect, respiratory motion can be tracked and visualized with accuracy comparable to that of the Varian RPM and Anzai belt.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP2-10: On the Need for a Dynamic Model for Patient-Specific Distortion Corrections for MR-Only Pelvis Treatment Planning

Purpose: Patient-specific distortions, particularly near tissue/air interfaces, require assessment and possible corrections for MRI-only radiation treatment planning (RTP). However, patients are dynamic due to changes in physiological status and motion during imaging sessions. This work investigated the need for dynamic patient-specific distortion corrections to support pelvis MR-only RTP. Methods: The pelvises of healthy volunteers were imaged at 1.0T, 1.5T, and 3.0T. Patient-specific distortion field maps were generated using a dual-echo gradient-recalled echo (GRE) sequence with B0 field maps obtained from the phase difference between the two echoes acquired at two timepoints: empty and full bladders. To quantify changes arising from respiratory state, end-inhalation and end-expiration data were acquired. Distortion map differences were computed between the empty/full bladder and inhalation/expiration to characterize local changes. The normalized frequency distortion distributions in T2-weighted TSE images were characterized, particularly for simulated prostate planning target volumes (PTVs). Results: Changes in rectal and bowel air location were observed, likely due to changes in bladder filling. Within the PTVs, displacement differences (mean ± stdev, range) were −0.02 ± 0.02 mm (−0.13 to 0.07 mm) for 1.0T, −0.1 ± 0.2 mm (−0.92 to 0.74 mm) for 1.5T, and −0.20 ± 0.03 mm (−0.61 to 0.38 mm) for 3.0T. Local changes of ∼1 mm at the prostate-rectal interface were observed for an extreme case at 1.5T. For end-inhale and end-exhale scans at 3.0T, 99% of the voxels had Δx differences within ±0.25mm, thus the displacement differences due to respiratory state appear negligible in the pelvis. Conclusion: Our work suggests that transient bowel/rectal gas due to bladder filling may yield non-negligible patient-specific distortion differences near the prostate/rectal interface, whereas respiration had minimal effect. A temporal patient model for patient-specific distortion corrections may be advantageous for MR-only RTP, although further investigations in larger cohorts are needed to fully characterize distortion magnitude. The submitting institution has research agreements with Philips Healthcare. Research sponsored by a Henry Ford Health System Internal Mentored Grant.

60 APPLIED LIFE SCIENCES↗

MO-DE-207A-12: Toward Patient-Specific 4DCT Reconstruction Using Adaptive Velocity Binning

Purpose: While 4DCT provides organ/tumor motion information, it often samples data over 10–20 breathing cycles. For patients presenting with compromised pulmonary function, breathing patterns can change over the acquisition time, potentially leading to tumor delineation discrepancies. This work introduces a novel adaptive velocity-modulated binning (AVB) 4DCT algorithm that modulates the reconstruction based on the respiratory waveform, yielding a patient-specific 4DCT solution. Methods: AVB was implemented in a research reconstruction configuration. After filtering the respiratory waveform, the algorithm examines neighboring data to a phase reconstruction point and the temporal gate is widened until the difference between the reconstruction point and waveform exceeds a threshold value—defined as percent difference between maximum/minimum waveform amplitude. The algorithm only impacts reconstruction if the gate width exceeds a set minimum temporal width required for accurate reconstruction. A sensitivity experiment of threshold values (0.5, 1, 5, 10, and 12%) was conducted to examine the interplay between threshold, signal to noise ratio (SNR), and image sharpness for phantom and several patient 4DCT cases using ten-phase reconstructions. Individual phase reconstructions were examined. Subtraction images and regions of interest were compared to quantify changes in SNR. Results: AVB increased signal in reconstructed 4DCT slices for respiratory waveforms that met the prescribed criteria. For the end-exhale phases, where the respiratory velocity is low, patient data revealed a threshold of 0.5% demonstrated increased SNR in the AVB reconstructions. For intermediate breathing phases, threshold values were required to be >10% to notice appreciable changes in CT intensity with AVB. AVB reconstructions exhibited appreciably higher SNR and reduced noise in regions of interest that were photon deprived such as the liver. Conclusion: We demonstrated that patient-specific velocity-based 4DCT reconstruction is feasible. Image noise was reduced with AVB, suggesting potential applications for low-dose acquisitions and to improve 4DCT reconstruction for irregular breathing patients. The submitting institution holds research agreements with Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

MO-FG-BRA-06: Electromagnetic Beacon Insertion in Lung Cancer Patients and Resultant Surrogacy Errors for Dynamic MLC Tumour Tracking

Purpose: To assess endo-bronchial electromagnetic beacon insertion and to quantify the geometric accuracy of using beacons as a surrogate for tumour motion in real-time multileaf collimator (MLC) tracking of lung tumours. Methods: The LIGHT SABR trial is a world-first clinical trial in which the MLC leaves move with lung tumours in real time on a standard linear accelerator. Tracking is performed based on implanted electromagnetic beacons (CalypsoTM, Varian Medical Systems, USA) as a surrogate for tumour motion. Five patients have been treated and have each had three beacons implanted endo-bronchially under fluoroscopic guidance. The centre of mass (C.O.M) has been used to adapt the MLC in real-time. The geometric error in using the beacon C.O.M as a surrogate for tumour motion was measured by measuring the tumour and beacon C.O.M in all phases of the respiratory cycle of a 4DCT. The surrogacy error was defined as the difference in beacon and tumour C.O.M relative to the reference phase (maximum exhale). Results: All five patients have had three beacons successfully implanted with no migration between simulation and end of treatment. Beacon placement relative to tumour C.O.M varied from 14 to 74 mm and in one patient spanned two lobes. Surrogacy error was measured in each patient on the simulation 4DCT and ranged from 0 to 3 mm. Surrogacy error as measured on 4DCT was subject to artefacts in mid-ventilation phases. Surrogacy error was a function of breathing phase and was typically larger at maximum inhale. Conclusion: Beacon placement and thus surrogacy error is a major component of geometric uncertainty in MLC tracking of lung tumours. Surrogacy error must be measured on each patient and incorporated into margin calculation. Reduction of surrogacy error is limited by airway anatomy, however should be taken into consideration when performing beacon insertion and planning. This research is funded by Varian Medical Systems via a collaborative research agreement.

60 APPLIED LIFE SCIENCES↗

WE-AB-202-05: Validation of Lung Stress Maps for CT-Ventilation Imaging

Purpose: To date, lung CT-ventilation imaging has been based on quantification of local breathing-induced changes in Hounsfield Units (HU) or volume. This work investigates the use of a stress map resulting from a biomechanical deformable image registration (DIR) algorithm as a metric of the ventilation function. Method: Eight lung cancer patients presenting different kinds of ventilation defects were retrospectively analyzed. Additionally, to the 4DCT acquired for radiotherapy planning, five of them had PET and three had SPECT imaging following inhalation of Ga-68 and Tc-99m, respectively. For each patient, the inhale phase of the 4DCT was registered to the exhale phase using Morfeus, a biomechanical DIR algorithm based on the determination of boundary conditions on the lung surfaces and vessel tree. To take into account the heterogeneity of the tissue stiffness in the stress map estimation, each tetrahedral element of the finite-element model was assigned a Young’s modulus ranging from 60kPa to 12MPa, as a function of the HU in the inhale CT. The node displacements and element stresses resulting from the numerical simulation were used to generate three CT-ventilation maps based on: (i) volume changes (Jacobian determinant), (ii) changes in HU, (iii) the maximum principal stress. The voxel-wise correlation between each CT-ventilation map and the PET or SPECT V image was computed in a lung mask. Results: For patients with PET, the mean (min-max) Spearman correlation coefficients r were: 0.33 (0.19–0.45), 0.36 (0.16–0.51) and 0.42 (0.21–0.59) considering the Jacobian, changes in HU and maximum principal stress, respectively. For patients with SPECT V, the mean r were: 0.12 (−0.12–0.43), 0.29 (0.22–0.45) and 0.33 (0.25–0.39). Conclusion: The maximum principal stress maps showed a stronger correlation with the ventilation images than the previously proposed Jacobian or change in HU maps. This metric thus appears promising for CT-ventilation imaging. This work was funded in part by NIH P01CA059827.

60 APPLIED LIFE SCIENCES↗