Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ERROR CORRECTING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

179 records · Page 10

Discrimination of correlated and entangling quantum channels with selective process tomography

The accurate and reliable characterization of quantum dynamical processes underlies efforts to validate quantum technologies, where discrimination between competing models of observed behaviors inform efforts to fabricate and operate qubit devices. We present a protocol for quantum channel discrimination that leverages advances in direct characterization of quantum dynamics (DCQD) codes. We demonstrate that DCQD codes enable selective process tomography to improve discrimination between entangling and correlated quantum dynamics. Numerical simulations show selective process tomography requires only a few measurement configurations to achieve a low false alarm rate and that the DCQD encoding improves the resilience of the protocol to hidden sources of noise. Lastly, our results show that selective process tomography with DCQD codes is useful for efficiently distinguishing sources of correlated crosstalk from uncorrelated noise in current and future experimental platforms.

97 MATHEMATICS AND COMPUTING↗

SU-E-J-258: Inter- and Intra-Fraction Setup Stability and Couch Change Tolerance for Image Guided Radiation Therapy

Purpose: Immobilization devices combine rigid patient fixation as well as comfort and play a key role providing the stability required for accurate radiation delivery. In the setup step, couch re-positioning needed to align the patient is derived via registration of acquired versus reference image. For subsequent fractions, replicating the initial setup should yield identical alignment errors when compared to the reference. This is not always the case and further couch re-positioning can be needed. An important quality assurance measure is to set couch tolerances beyond which additional investigations are needed. The purpose of this work was to study the inter-fraction couch changes needed to re-align the patient and the intra-fraction stability of the alignment as a guide to establish the couch tolerances. Methods: Data from twelve patients treated on the Accuray CyberKnife (CK) system for fractionated intracranial radiotherapy and immobilized with Aquaplast RT, U-frame, F-Head-Support (Qfix, PA, USA) was used. Each fraction involved image acquisitions and registration with the reference to re-align the patient. The absolute couch position corresponding to the approved setup alignment was recorded per fraction. Intra-fraction set-up corrections were recorded throughout the treatment. Results: The average approved setup alignment was 0.03±0.28mm, 0.15±0.22mm, 0.06±0.31mm in the L/R, A/P, S/I directions respectively and 0.00±0.35degrees, 0.03±0.32degrees, 0.08±0.45degrees for roll, pitch and yaw respectively. The inter-fraction reproducibility of the couch position was 6.65mm, 10.55mm, and 4.77mm in the L/R, A/P and S/I directions respectively and 0.82degrees, 0.71degrees for roll and pitch respectively. Intra-fraction monitoring showed small average errors of 0.21±0.21mm, 0.00±0.08mm, 0.23±0.22mm in the L/R, A/P, S/I directions respectively and 0.03±0.12degrees, 0.04±0.25degrees, and 0.13±0.15degrees in the roll, pitch and yaw respectively. Conclusion: The inter-fraction reproducibility should serve as a guide to couch tolerances, specific to a site and immobilization. More patients need to be included to make general conclusions.

60 APPLIED LIFE SCIENCES↗

An Extreme-precision Radial-velocity Pipeline: First Radial Velocities from EXPRES

The EXtreme-PREcision Spectrograph (EXPRES) is an environmentally stabilized, fiber-fed, R = 137,500, optical spectrograph. It was recently commissioned at the 4.3 m Lowell Discovery Telescope near Flagstaff, Arizona. The spectrograph was designed with a target radial-velocity (RV) precision of 30 cm s{sup −1}. In addition to instrumental innovations, the EXPRES pipeline, presented here, is the first on-sky, optical, fiber-fed spectrograph to employ many novel techniques—including an “extended flat” fiber used for wavelength-dependent quantum efficiency characterization of the CCD, a flat-relative optimal extraction algorithm, chromatic barycentric corrections, chromatic calibration offsets, and an ultra-precise laser frequency comb for wavelength calibration. We describe the reduction, calibration, and RV analysis pipeline used for EXPRES and present an example of our current sub-meter-per-second RV measurement precision, which reaches a formal, single-measurement error of 0.3 m s{sup −1} for an observation with a per-pixel signal-to-noise ratio of 250. These velocities yield an orbital solution on the known exoplanet host 51 Peg that matches literature values with a residual rms of 0.895 m s{sup −1}.

79 ASTRONOMY AND ASTROPHYSICS↗

Perturbative model of noisy quantum signal processing

Recent progress in quantum signal processing (QSP) and its generalization, quantum singular value transformation, has led to a grand unification of quantum algorithms. However, inherent experimental noise in quantum devices severely limits the length of realizable QSP sequences. Here, we consider a model of QSP with generic perturbative noise in the signal processing basis and present a diagrammatic notation useful for analyzing such errors. To demonstrate our technique, we study a specific coherent error, that of under- or overrotation of the signal processing operator parametrized by ε<<1. For this coherent error model, it is shown that while Pauli Z errors are not recoverable without additional resources, Pauli X and Y errors can be arbitrarily suppressed by coherently appending a noisy recovery QSP without the use of additional resources or ancillas. Furthermore, through a careful accounting of errors using our diagrammatic tools, we provide an upper and lower bound on the length of this recovery QSP operator. We anticipate that the perturbative technique and the diagrammatic notation proposed here will facilitate future study of generic noise in QSP and quantum algorithms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Exchange-correlation functional challenges in modeling quaternary chalcogenides

The development of next-generation quaternary chalcogenides, such as Cu2ZnSnS4 (CZTS) and Cu2ZnGeS4 (CZGS), for solar energy and thermoelectric applications hinges upon both careful experimentation and accurate quantum mechanical modeling. To address the latter, many have turned to density functional theory (DFT), which offers several choices for the approximate treatment of electron exchange and correlation (XC). Popular XC functionals include the Perdew-Burke-Ernzerhof (PBE) generalized gradient approximation (GGA) and the recently developed strongly constrained and appropriately normed (SCAN) meta-GGA. Extensions of DFT functionals, such as adding a Hubbard U correction and introducing a fraction of the Fock exchange (hybrid functionals), have been used widely to model systems containing 3d metal ions. However, no studies yet have compared comprehensively PBE(+U) and SCAN(+U) in the quality of their predictions of the bulk and defect thermodynamics of quaternary chalcogenides, which play a critical role in device fabrication and performance. Hence, here we calculate the (i) 0 K formation energies of bulk Ge compounds and (ii) neutral defect formation energies including charge-balanced (e.g., CuZn + ZnCu) and charge-imbalanced (e.g., CuSn) combinations of antisites and vacancies in CZTS and CZGS using the PBE, PBE +U, SCAN, SCAN +U, and the hybrid Heyd-Scuseria-Ernzerhof XC frameworks. We find that the formation energies of charge-imbalanced defects are more sensitive to the choice of the XC functional than those of charge-balanced defects, which can be explained by the differences in the extent of penalization of defect-generated delocalized electrons/holes by PBE, PBE +U, SCAN, and SCAN +U. Additionally, our results show that SCAN systematically underbinds Ge-containing compounds, thus highlighting the need for even further improvement of XC functionals. Based on our findings, we recommend the use of SCAN for modeling quaternary chalcogenides because its errors are systematic, and it has the firmest theoretical underpinning. Our work provides guidance for future modeling of quaternary chalcogenides.

14 SOLAR ENERGY↗

A proposed high-intensity radiometer calibration method using concentrated solar radiation

Accurate calibration of irradiance measurement devices, or radiometers, is essential for ensuring the reliability of measurements in high heat applications such as concentrating solar power (CSP), aerospace, defense, and pulsed power systems. Despite the critical need, existing calibration standards and service providers are limited to irradiance levels below 100 kW/m 2 and specific radiation sources, which is insufficient for many applications. For instance, CSP technologies, particularly those under the Department of Energy’s Solar Energy Technologies Office (SETO) Gen 3 program, require accurate measurements of broadband irradiance at levels exceeding 2000 kW/m 2 . In even more extreme scenarios, such as re-entry vehicles, heat levels can surpass 10000 kW/m 2 . Current ISO standards, specifically ISO 14934–2 and ISO 14934–3, are constrained to lower irradiance levels and dependent on black body heat sources, limiting their applicability for high-intensity broadband irradiance measurements, particularly in concentrated solar applications. Here, to address this shortfall, the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories (SNL) proposes a calibration method and facility capable of characterizing radiometers up to 2750 kW/m 2 using concentrated solar irradiance. Calibrating with concentrated sunlight is important for solar applications as it aligns the calibration process with the solar spectrum. This alignment is crucial for minimizing systematic errors and avoiding the need for additional corrections that may arise when radiometers designed for solar applications are calibrated using black-body or electrical sources. This paper presents the present day NSTTF characterization facility and procedure, detailing the proposed calibration method and uncertainty quantification. The presented method builds upon 1980′s NSTTF methodology and involves both theoretical and empirical methods to establish a robust relationship between gauge voltage output and irradiance intensity, quantifying both measurement and fitting errors. By addressing the limitations of existing standards and extending the characterization range, this work provides an advancement in the field of high-intensity irradiance measurement and instrumentation characterization.

Gardon gauge↗

Metal artifact correction for x-ray computed tomography using kV and selective MV imaging

Purpose: The overall goal of this work is to improve the computed tomography (CT) image quality for patients with metal implants or fillings by completing the missing kilovoltage (kV) projection data with selectively acquired megavoltage (MV) data that do not suffer from photon starvation. When both of these imaging systems, which are available on current radiotherapy devices, are used, metal streak artifacts are avoided, and the soft-tissue contrast is restored, even for regions in which the kV data cannot contribute any information. Methods: Three image-reconstruction methods, including two filtered back-projection (FBP)-based analytic methods and one iterative method, for combining kV and MV projection data from the two on-board imaging systems of a radiotherapy device are presented in this work. The analytic reconstruction methods modify the MV data based on the information in the projection or image domains and then patch the data onto the kV projections for a FBP reconstruction. In the iterative reconstruction, the authors used dual-energy (DE) penalized weighted least-squares (PWLS) methods to simultaneously combine the kV/MV data and perform the reconstruction. Results: The authors compared kV/MV reconstructions to kV-only reconstructions using a dental phantom with fillings and a hip-implant numerical phantom. Simulation results indicated that dual-energy sinogram patch FBP and the modified dual-energy PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in the kV projections. The root-mean-square errors of soft-tissue patterns obtained using combined kV/MV data are 10–15 Hounsfield units smaller than those of the kV-only images, and the structural similarity index measure also indicates a 5%–10% improvement in the image quality. The added dose from the MV scan is much less than the dose from the kV scan if a high efficiency MV detector is assumed. Conclusions: The authors have shown that it is possible to improve the image quality of kV CTs for patients with metal implants or fillings by completing the missing kV projection data with selectively acquired MV data that do not suffer from photon starvation. Numerical simulations demonstrated that dual-energy sinogram patch FBP and a modified kV/MV PWLS method can successfully suppress metal streak artifacts and restore information lost due to photon starvation in kV projections. Combined kV/MV images may permit the improved delineation of structures of interest in CT images for patients with metal implants or fillings.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Simple correction for the sample shape and radial offset effects on SQUID magnetometers: Magnetic measurements on Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er) standards

An increased focus on magnetic measurements of oriented single crystals, thin films, and magnetically dilute systems has led to a demand for the measurement of weak magnetic moments. This level of sensitivity and precision can be achieved on SQUID magnetometers by decreasing the size of the detection coils. However, the smaller detection coils can amplify two errors in the magnitude of the measured moment, the sample shape and radial offset effects, which were small and typically unaccounted for on previous magnetometers. We report a simple method to determine the radial offset of a sample by taking advantage of the two basic scan modes, DC and lock-in, typically used on magnetometers. This technique allows for the correction of the sample shape and radial offset effects in order to obtain the true moment of a sample. To show the efficacy of this technique, we report the magnetic properties of Ln{sub 2}O{sub 3} (Ln=Gd, Dy, Er). - Graphical abstract: Correction for the sample shape and radial offset effects on SQUID magnetometers using a combination of DC and VSM scan data. - Highlights: • Sample shape and radial offset effects alter the moment measured by magnetometers. • We present a simple method to correct for these sample effects on magnetometers. • We measure magnetic susceptibilities of Ln{sub 2}O{sub 3} to show the efficacy of this method.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calculated and Measured Dose Distributions in an Anthropomorphic RANDO Phantom - Paper 105

Patient-specific quality assurance (QA) is a major component of the Intensity Modulated Radiation Therapy (IMRT) clinical process. The objective of this often time-intensive measurement process is to verify that the prescribed dose is accurately delivered to the target volume while sparing surrounding healthy tissue. The IMRT dose distributions can be measured using a wide variety of techniques and measurement devices including film (radiographic and radiochromic), ion chamber arrays, diode arrays, and Electronic Portal Imaging Devices (EPIDs). Of all the available modalities, film is one of the most versatile and most frequently utilized measurement systems. In rotation delivery techniques (such as volume modulated arc therapy and helical tomotherapy), composite dose distributions are obtained by irradiating a test phantom containing dosimeter(s). When film is utilized as the dosimeter, it can be placed in coronal, sagittal, or transverse planes inside the phantom. Because the film is irradiated using the rotational delivery sequence used to treat the patient, the dose given to specific anatomical structures (such as the parotids, spinal cord, bladder, rectum etc...) can be evaluated. Thomas et al (Med Phys 32: 3793-3800) recently reported the results of IMRT verifications for ten patients planned and treated with helical tomotherapy. This study reported that nearly 92% of the film pixels within the analyzed region of interest were within a gamma criterion of 2 mm and 2%. Like most tomotherapy users, Thomas et al used a test phantom made of homogeneous water equivalent material. Heterogeneous phantoms that simulate the different tissue densities in the human body do exist, but are infrequently used for patient-specific IMRT QA. The potential advantage of using heterogeneous phantoms is that the measured dose distributions will more adequately reflect the clinical dose distributions in the patients. The use of homogenous phantoms during IMRT quality assurance can potentially mask errors that arise from limitations in the treatment planning system's modeling of density corrections. The purpose of this study was to evaluate the dosimetric accuracy of a helical tomotherapy system using an anthropomorphic RANDO phantom (The Phantom Laboratory, Salem, NY) for patient-specific QA. The results of this study will allow a benchmark to be established for dosimetric accuracy in heterogeneous materials. Performing patient-specific QA is an integral part of the IMRT patient treatment process. Test phantoms are typically homogeneous, and do test the treatment planning systems ability to account for heterogeneity corrections. In this study, an anthropomorphic RANDO phantom was used to evaluate the doses calculated by a helical tomotherapy system. The dosimetric agreement between calculated and measured was worse than published results in homogenous phantoms, especially for target volumes located in the lung. Further investigation will be needed to determine if these errors are due to film response at heterogeneous tissue interfaces or from actual dose calculation errors. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Fringing Analysis and Simulation for the Vera C. Rubin Observatory’s Legacy Survey of Space and Time

Abstract The presence of fringing in astronomical Charge-Coupled Device (CCD) images will have an impact on photometric quality and measurements. Yet its impact on the Vera C. Rubin Observatory’s Legacy Survey of Space and Time (LSST) has not been fully studied. We present a detailed study on fringing for CCDs already implemented on the Rubin Observatory LSST Camera’s focal plane. After making physical measurements and knowing the compositions, we developed a model for the e2v CCDs. We present a method to fit for the internal height variation of the epoxy layer within the sensors based on fringing measurements in a laboratory setting. This method is generic enough that it can be easily modified to work for other CCDs. Using the derived fringing model, we successfully reproduce comparable fringing amplitudes that match the observed levels in images taken by existing telescopes with different optical designs. This model is then used to forecast the expected level of fringing in a single LSST y -band sky background exposure with Rubin telescope optics in the presence of a realistic time-varying sky spectrum. The predicted fringing amplitude in LSST images ranges from 0.04% to 0.2% depending on the location of a CCD on the focal plane. We find that the predicted variation in surface brightness caused by fringing in LSST y -band sky background images is about 0.6 μ Jy arcsec − 2 , which is 40 times larger than the current measurement error. We conclude that it is necessary to include fringing correction in the Rubin’s LSST image processing pipeline.

Astronomy & Astrophysics↗

Using a Large Language Model as a Building Block to Generate Usable Validation and Verification Suite for OpenMP

In the HPC area, both hardware and software move quickly. Often new hardware is developed and deployed, the corresponding software stack, including compilers and other tools, are under active development while leading edge software developers are working to port and tune their applications, all at the same time. While the software ecosystem is in flux, one of the key challenges for users is obtaining insight into the state of implementation of key features in the programming languages and models their applications are using – whether they have been implemented, and whether the implementation conforms to the specification, especially for newly implemented features (less tested by widespread use). OpenMP is one of the most prominent shared memory programming models used for on-node programming in HPC. With the shift towards accelerators (such as GPUs and FPGAs) and heterogeneous programming OpenMP features are getting more complex. It is natural to ask whether generative AI approaches, and large language models (LLMs) in particular, can help in producing validation and verification test suites to allow users better and faster insights into the availability and correctness of OpenMP features of interest. In this work, we explore the use of ChatGPT-4 to generate a suite of tests for OpenMP features. We have chosen a set of directives and clauses, a total of 78 combinations, which first appeared in OpenMP 3.0 (released in May 2008) but are also relevant for accelerators. We prompted ChatGPT to generate tests in the C and Fortran languages, for both host (CPU) and device (accelerator). On the Summit super-computer using the GNU implementation, we found that, of the 78 generated tests 67 C tests and 43 Fortran tests compiled successfully and fewer than those executed to completion. On further analysis we show that not all generated tests are valid. We document the process, results, and provide detailed analysis regarding the quality of tests generated. With the aim of providing input to a production quality validation and verification suite, we manually implement the corrections required to make the tests valid according to the current OpenMP specification. We quantify this effort as small, medium, or large, and record the lines of code changed to correct the invalid tests. With the corrected tests we validate recent implementations from HPE, AMD, and GNU on the Frontier supercomputer. Our experiment and subsequent analysis show that although LLMs are capable of producing HPC specific codes, they are limited by their understanding of the deeper semantics and restrictions of programming models such as OpenMP. Unsurprisingly more commonly used features have better support, while some OpenMP 3.0 directives such as sections and tasking are not universally supported on accelerators. We demonstrate that successful compilation and execution to completion are inadequate metrics for evaluating generated code and that, at this time, commodity LLMs require expert intervention for code verification. This points to gaps in the training data that is currently available for HPC. We demonstrate that with "small" effort 37% of generated invalid C tests and 63% of generated invalid Fortran tests could be corrected. This improves productivity of test generation as we circumvent writing from scratch and the common programming errors associated with it.

Pophale, Swaroop [ORNL] (ORCID:0000000185446367)↗

Silver clusters tune up electronic properties of graphene nanoflakes: A comprehensive theoretical study

Graphene-silver composites reflect a synergic effect of both components with enhanced electronic, adsorption and catalytic properties. We introduce here the detailed theoretical study on geometric, thermodynamic and electronic properties of silver clusters Ag n (n=2–10) adsorbed on graphene nanoflakes as a model for silver-graphene composites. First, a benchmark study is performed on Ag n …coronene complexes (n=2, 4) by evaluating various functional against reported high level ab-initio method for the selection of best functional for further calculations. Then, density functional theory study at the best chosen level is performed to inquire how clustering of adsorbate attached with carbon surface can impact geometric, electronic and thermodynamic properties of silver-graphene composites. Furthermore, the interaction energies are corrected for dispersion and basis set superposition error in order to get more realistic estimate of interaction energies. In progression, we investigated the dependence of interaction energy upon cluster size and dimensionality. For Ag n …coronene, the binding energies increase monotonically as the number of atoms in the cluster increases. However, for Ag n …dodecabenzocoronene, the interaction energies show a sudden drop at Ag 7 …dodecabenzocoronene. The difference in behavior between Ag n …dodecabenzocoronene and Ag n …coronene for interaction energy is attributed to edge effect present in coronene. Furthermore, coplanar orientations of the silver clusters on polyaromatic hydrocarbons have higher interaction energies. The 2D-3D transition of the silver cluster is observed for Ag 7 …coronene. CDA analysis reveals that backdonation from dodecabenzocoronene to silver clusters is more dominant in Ag 4 –Ag 7 whereas other clusters have dominant charge transfer to dodecabenzocoronene. Charge transfer analysis via constrained density functional theory (CDFT) reveals significant energy lowering from charge donor-acceptor interactions. Further energy decomposition analysis (EDA) using absolutely-localized molecular orbitals (ALMO) suggests that, while charge-transfer is important in these systems, the sum of electrostatics, Pauli repulsion, and London dispersion are far more significant as silver cluster size increases. NCI results also support the presence of van der Waals and electrostatic interactions. The hollow top is most favorite interaction sites compared to bridge top and head top binding sites over coronene lattice. The ionization potential, electron affinity, frontier molecular orbital analysis, chemical hardness, softness, chemical potential, and Fermi levels are deliberated to verify the stability and reactivity of most stable silver-graphene composites. The remarkable outcome of the current findings makes our silver-graphene composite as a potential applicant for high performance electronic and catalytic devices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Spectroscopic Measurements and Models of Energy Deposition in the Substrate of Quantum Circuits by Natural Ionizing Radiation

Naturally occurring background radiation is a potential source of correlated decoherence events in superconducting qubits that will challenge error-correction schemes. In order to characterize the radiation environment in an unshielded laboratory representative of superconducting qubits’ environments, we performed broadband, spectroscopic measurements of background radiation events inside a millikelvin refrigerator. The spectrometer was designed to mimic the size and composition of a quantum circuit. Specifically, we measured the background radiation spectra in silicon substrates of two thicknesses, 500 and 1500 µm, and one area, 25 mm 2 . The observed spectra span energies from a few kilo-electron-volts up to nearly 10 MeV, are nearly featureless, and decrease in intensity by a factor of 40 000 between 100 keV and 3 MeV for the 500-µm substrate. We integrate the spectra to obtain the average event rates and deposited power levels. These quantities correspond to a rate of 0.023 events per second and a power of 4.9 keV s -1 , when counting events that deposit at least 40 keV for the 500-µm-thick substrate. We find that the cryogenic measurements are in good agreement with predictions based on simple measurements of the terrestrial gamma-ray flux outside the refrigerator, published models of cosmic-ray fluxes, a crude model of the cryostat, and radiation-transport simulations. This model requires no free parameters to predict the background radiation spectra in the silicon substrates. The agreement between measurements and predictions demonstrates that the model we present can be used to assess the relative contributions of terrestrial and cosmic-ray sources to background radiation interactions in silicon substrates of varying thickness. These spectroscopic measurements are performed with a novel combination of superconducting microresonators located on micromachined silicon islands that define the interaction volume with background radiation. The resonators transduce deposited energy to a readily detectable electrical signal. Microresonator readout closely resembles dispersive superconducting qubit readout, so similar devices—with or without micromachined islands—are suitable for integration with superconducting quantum circuits as detectors for background radiation events. For our specific laboratory conditions, we find that gamma-ray emissions from radioisotopes are responsible for the majority of events that deposit E < 1 ⁢Me⁢V. We present results demonstrating that the background radiation spectrum contains relevant contributions from cosmic-ray particles other than muons, particularly a tail of multi-mega-electron-volt events due to protons and neutrons. These observations suggest several paths to reducing the impact of background radiation on quantum circuits, supported by an empirically validated model for generating reliable predictions of radiation interactions with silicon substrates.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

REFINED SYSTEM PARAMETERS AND TTV STUDY OF TRANSITING EXOPLANETARY SYSTEM HAT-P-20

We report new photometric observations of the transiting exoplanetary system HAT-P-20, obtained using CCD cameras at Yunnan Observatories and Ho Koon Nature Education cum Astronomical Centre, China, from 2010 to 2013, and Observatori Ca l’Ou, Sant Marti Sesgueioles, Spain, from 2013 to 2015. The observed data are corrected for systematic errors according to the coarse de-correlation and SYSREM algorithms, so as to enhance the signal of the transit events. In order to consistently model the star spots and transits of this exoplanetary system, we develop a highly efficient tool STMT based on the analytic models of Mandel and Agol and Montalto et al. The physical parameters of HAT-P-20 are refined by homogeneously analyzing our new data, the radial velocity data, and the earlier photometric data in the literature with the Markov chain Monte Carlo technique. New radii and masses of both host star and planet are larger than those in the discovery paper due to the discrepancy of the radius among K-dwarfs between predicted values by standard stellar models and empirical calibration from observations. Through the analysis of all available mid-transit times calculated with the normal model and spotted model, we conclude that the periodic transit timing variations in these transit events revealed by employing the normal model are probably induced by spot crossing events. From the analysis of the distribution of occulted spots by HAT-P-20b, we constrain the misaligned architecture between the planetary orbit and the spin of the host star.

79 ASTRONOMY AND ASTROPHYSICS↗

Quasi-Fermi level splitting and sub-bandgap absorptivity from semiconductor photoluminescence

A unified model for the direct gap absorption coefficient (band-edge and sub-bandgap) is developed that encompasses the functional forms of the Urbach, Thomas-Fermi, screened Thomas-Fermi, and Franz-Keldysh models of sub-bandgap absorption as specific cases. We combine this model of absorption with an occupation-corrected non-equilibrium Planck law for the spontaneous emission of photons to yield a model of photoluminescence (PL) with broad applicability to band-band photoluminescence from intrinsic, heavily doped, and strongly compensated semiconductors. The utility of the model is that it is amenable to full-spectrum fitting of absolute intensity PL data and yields: (1) the quasi-Fermi level splitting, (2) the local lattice temperature, (3) the direct bandgap, (4) the functional form of the sub-bandgap absorption, and (5) the energy broadening parameter (Urbach energy, magnitude of potential fluctuations, etc.). The accuracy of the model is demonstrated by fitting the room temperature PL spectrum of GaAs. It is then applied to Cu(In,Ga)(S,Se){sub 2} (CIGSSe) and Cu{sub 2}ZnSn(S,Se){sub 4} (CZTSSe) to reveal the nature of their tail states. For GaAs, the model fit is excellent, and fitted parameters match literature values for the bandgap (1.42 eV), functional form of the sub-bandgap states (purely Urbach in nature), and energy broadening parameter (Urbach energy of 9.4 meV). For CIGSSe and CZTSSe, the model fits yield quasi-Fermi leveling splittings that match well with the open circuit voltages measured on devices made from the same materials and bandgaps that match well with those extracted from EQE measurements on the devices. The power of the exponential decay of the absorption coefficient into the bandgap is found to be in the range of 1.2 to 1.6, suggesting that tunneling in the presence of local electrostatic potential fluctuations is a dominant factor contributing to the sub-bandgap absorption by either purely electrostatic (screened Thomas-Fermi) or a photon-assisted tunneling mechanism (Franz-Keldysh). A Gaussian distribution of bandgaps (local E{sub g} fluctuation) is found to be inconsistent with the data. The sub-bandgap absorption of the CZTSSe absorber is found to be larger than that for CIGSSe for materials that yield roughly equivalent photovoltaic devices (8% efficient). Further, it is shown that fitting only portions of the PL spectrum (e.g., low energy for energy broadening parameter and high energy for quasi-Fermi level splitting) may lead to significant errors for materials with substantial sub-bandgap absorption and emission.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development of Quantum Interconnects (QuICs) for Next-Generation Information Technologies

Just as “classical” information technology rests on a foundation built of interconnected information-processing systems, quantum information technology (QIT) must do the same. A critical component of such systems is the “interconnect,” a device or process that allows transfer of information between disparate physical media, for example, semiconductor electronics, individual atoms, light pulses in optical fiber, or microwave fields. While interconnects have been well engineered for decades in the realm of classical information technology, quantum interconnects (QuICs) present special challenges, as they must allow the transfer of fragile quantum states between different physical parts or degrees of freedom of the system. The diversity of QIT platforms (superconducting, atomic, solid-state color center, optical, etc.) that will form a “quantum internet” poses additional challenges. As quantum systems scale to larger size, the quantum interconnect bottleneck is imminent, and is emerging as a grand challenge for QIT. For these reasons, it is the position of the community represented by participants of the NSF workshop on “Quantum Interconnects” that accelerating QuIC research is crucial for sustained development of a national quantum science and technology program. Given the diversity of QIT platforms, materials used, applications, and infrastructure required, a convergent research program including partnership between academia, industry, and national laboratories is required.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters Christopher A. Zarzana1, Makayla R. Baxter , Introduction: Molecular hydrogen is a potential energy carrier that could be used to help implement a clean energy economy if it is generated from splitting of water. Improvements in the efficiencies of water-splitting electrolyzers relies on development of novel materials with enhanced performance. However, research in this area is slowed due to underdeveloped understanding of the mechanisms of device performance due to challenges interrogating the fundamental chemical reactions at play in bulk materials. Studies of the intrinsic reactivity of clusters that are representative of the reactive sites of these materials can increase understanding of the fundamental reaction mechanisms involved in hydrogen production, allowing for more efficient development of new water-splitting materials. Methods: Holmium tetranitrato ([Ho(NO3)4]-) clusters were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Spray solutions consisted of aqueous holmium (Ho) nitrate solutions (at nominally 3 mM) diluted to 30 µM in acetonitrile. The holmium (Ho) tetranitrato clusters were isolated using the quadrupole and were subsequently activated and allowed to react with background water in the collision cell. High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data: Collisional activation of the holmium tetranitrato complexes ([Ln(NO3)4]-) resulted in an expected series of ions resulting from the loss of ·NO and ·NO2. This included an ion at m/z = 382.885 assigned as [HoO2(NO3)3]- (theoretical m/z=382.884, error=-1.2 ppm), resulting from loss of ·NO, and an ion at m/z=366.890 assigned as [HoO(NO3)3]- (theorical m/z=366.889, error=-1.8 ppm), resulting from loss of ·NO2. Additional ions were detected that would result from more complicated losses from [Ho(NO3)4]-, including ions at m/z=320.898 assigned as [HoO2(NO3)2]- (theoretical m/z=320.896, error=-4.9 ppm), at m/z=304.904 assigned as [HoO(NO3)2]- (theoretical m/z=304.901, error=-8.1 ppm, very low signal), and at m/z=288.908 assigned as [Ho(NO3)2]- (theoretical m/z=288.907, error=-3.4 ppm). This ion series would arise from loss of some combination of ·NO, ·NO2, and ·NO3, although it is not known whether these losses occur sequentially (e.g. loss of ·NO and ·NO3 to yield [HoO2(NO3)2]-) or as a single species (e.g. direct loss of N2O4). These ions were accompanied by a complementary series representing addition of a single water molecule. This included an ion at m/z=338.908 assigned as [HoO2(NO3)2H2O]- (theoretical m/z=338.907, error=-4.1 ppm), an ion at m/z=322.912 assigned as [HoO(NO3)2H2O]- (theoretical m/z=322.912, error=1.2 ppm), and an ion at m/z=306.918 assigned as [Ho(NO3)2H2O]-, (theoretical m/z=306.918, error=-3.7 ppm). An additional hydrated ion was observed at m/z=276.921 assigned as [HoO2(NO3) H2O]- (theoretical m/z=276.919, error=-7.3 ppm), although corresponding dehydrated ion was not observed. An additional ion was observed at m/z=367.898 that has been assigned as [Ho(NO3)3OH]- (theoretical m/z=367.897, error=-2.5 ppm). It is hypothesized that this ion arises from addition of water to [Ho(NO3)3]- followed by elimination of a hydrogen radical. Neither [Ho(NO3)3]- nor [Ho(NO3)3H2O]- were detected, suggesting that, if the hypothesis is correct, addition of water to [Ho(NO3)3]- and its subsequent splitting is rapid. Elimination of HNO3 from [Ho(NO3)4H2O]- could also yield [Ho(NO3)3OH]-; however, no [Ho(NO3)4H2O]- ions were observed. Novelty: Potential evidence of water splitting on gas-phase lanthanide clusters offers a way to study the intrinsic reactivity of hydrogen-generation materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗