Radiation Detection Equipment Demonstration Overview for International Workshop - March 2022 [Slides]
Abstract not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Abstract not provided.
This report presents the sampling and analytical results for chemical constituents for soils potentially impacted by the reconstruction of the intersection at New Mexico (NM) State Road 4 (NM 4) and East Jemez Road (NM State Road 502 [NM 502]).
Abstract not provided.
Presentation to be submitted to the Institute of Nuclear Materials Management (INMM) for presentation during the INMM 63rd Annual Meeting, July 24–28, 2022, https://inmm.org/mpage/INMM22.
Improvements in computing system security updates and purchasing policies could save the Army as much as 85 million kWh and $5 million per year when applied to the Army’s more than one million computers. This represents the largest and highest-priority plug load energy-and cost-saving measure identified by a recent study focused on Army buildings.
Vending machines consume the most energy of individual plug load devices common to Army buildings. As a group, they rank fourth in total electricity consumption, behind only clothes dryers, laptop computers, and telecom loads. Upgrading 80% of the estimated 22,000 refrigerated vending machines on Army installations to the latest ENERGY STAR ® performance and optimizing their efficiency settings could save 31 million kWh and $2 million per year.
The content and script for the STEP Leaders Program on the differences between managing and leading.
The content and script for the STEP Leaders Program on hiring practices in the ALDWP.
The DOE Technologist in Residence (TIR) program pairs a senior technical staff member from a National Laboratory (Lab Technologist), and a senior technical staff member(s) from a clean energy manufacturing company or consortium of companies (Industry Technologist). Each technologist may represent single or multiple national laboratories, or single or multiple companies. These pairs of Lab and industry technologists work together for a period of 18 to 24 months to accomplish several goals: 1) Identify the participating company’s (or companies’) technical priorities and challenges, and the resources and capabilities in DOE’s National Laboratories that may be highly suitable to address them; 2) Propose collaborative R&D efforts to develop science-based solutions to the company’s (or companies’) most strategic scientific, technological, and business issues; and 3) Develop a general framework agreement and begin developing specific scopes of work for the proposed collaborative R&D efforts. The proposed R&D will then take place outside of the program and will not use TIR program funds. Oak Ridge National Laboratory (ORNL) and Pioneer Natural Resources were awarded a TIR project by DOE in late 2016 and the CRADA component of the project was initiated in 2017. This report describes work performed under the CRADA agreement between 2017 and 2020.
This study investigated the energy and cost savings potential by modeling a dual fuel heat pump system with its control for a residential building in (5A) cold climate in U.S. The simulation analysis showed that the application of the DFHP system and its control to the target building can save the heating energy by 42% over a gas furnace system (baseline system). Although the HP-only system can save more heating energy (i.e.,53%) over the baseline system than DFHP system does, the DFHP with its control demonstrated the higher cost savings when a time of use electricity rate was considered.
Abstract not provided.
In this exercise, you will use the Insta360 X3 action cameras to capture mock inspection footage and review the footage to identify objects that were hidden in the facility.
The National Reactor Innovation Center (NRIC) is a national program that was established as part of the Nuclear Energy Innovation Capabilities Act (NEICA). NRIC’s mission is to accelerate the demonstration and deployment of advanced nuclear energy through its mission to inspire stakeholders and the public, empower innovators, and deliver successful outcomes through efficient coordination of partners and resources. NRIC is designed to bridge the gap between research, development, and the marketplace to help convert some of the nation’s most promising advanced nuclear reactors into commercial applications.
The US Department of Energy (DOE) Building Technology Office (BTO) and the Air-conditioning, Heating & Refrigeration Technology Institute (AHRTI) collaborated to sponsor an experimental study of refrigerant leak characteristics at Oak Ridge National Laboratory (ORNL); AHRTI project 9012. The project has been conducted in two phases with objectives to conduct refrigerant leak tests on several heating, ventilating, air-conditioning and refrigeration (HVAC&R) systems under operating conditions representative of actual applications to document the pressure decay rate and the mass flow rate of leaked refrigerant as a function of time. Phase 1 of the project ran from late 2017 to late 2018 with refrigerant leaks imposed on five systems and the collection of data to meet the project objectives. Systems chosen covered three air-conditioning (AC) applications (packaged terminal AC or PTAC, 3-ton residential split system AC, and 5-ton packaged rooftop AC) and two refrigeration applications (split system unit cooler, and standalone display case). AHRTI members donated the test systems used for the project. The systems were tested at two different leak rates (catastrophic high rate simulating full line break and a lower flow rate), two leak locations (high-pressure side and low-pressure side), and two operating conditions (compressor ON or OFF). Phase 1 results were summarized in a project report by Baxter, et al. (2019)1. The leak rates imposed in Phase 1 led to much more rapid charge releases than the more typical much slower rates seen in practice that would take days, weeks, or months to empty a system of its entire charge. For Phase 2, the project sponsors asked that the “higher” leak rate target a total charge release time of about 4 min. This was intended to represent a “reasonable” worst case release scenario to match the refrigerant leak rate assumption used in the International Electrotechnical Commission (IEC) standard IEC 60335-2-40 (2016 version [IEC 2016]. A charge release time of about 20–40 min (leak release rate 5 to 10 times lower than higher rate) was targeted for the “lower” leak rate. This report provides a summary of the Phase 2 effort. Two additional HVAC systems were selected for testing in this phase. First was a multi-split air-conditioning (MS-AC) system with one outdoor section and two indoor units and a nameplate refrigerant charge of 1.75 kg (3.86 lb.) of R-410A. The MS-AC was tested in cooling only or AC operation. Second was a split system heat pump coupled to two different representative supply duct systems (HP-duct) and a nameplate charge of 3.83 kg (8.44 lb.) of R-410A. This system was tested in both space heating and AC modes. As in Phase 1 of the project, all tests were conducted using R-410A.
This project developed a highly promising, minimally invasive pathway for transformers with up to double the thermal life that is achieved today. Thermal life is important because it is occasionally necessary to overload transformers in service and this overload raises the internal temperature, accelerating aging2. A seminal initial finding in the research was that a likely achievable increase in the thermal conductivity of the transformer paper could double the thermal life. Oil-impregnated paper is used to wrap the electrical conductors in a transformer to provide a good balance of electrical insulation and thermal conductivity. The novel approach to increase the thermal conductivity was to add micrometer boron nitride particles to the paper during manufacturing. This is encouraging because it provides benefits with minimal impact on the manufacturing processes of the paper or of a transformer.
Abstract not provided.