At least 181 records · Page 10

Feasibility studies of time-like proton electromagnetic form factors at $\overline{\rm P}$ANDA at FAIR

Simulation results for future measurements of electromagnetic proton form factors at $\overline{\rm P}$ANDA (FAIR) within the PandaRoot software framework are reported. The statistical precision with which the proton form factors can be determined is estimated. The signal channel p¯p → e + e – is studied on the basis of two different but consistent procedures. The suppression of the main background channel, i.e. p¯p → π + π – , is studied. Furthermore, the background versus signal efficiency, statistical and systematical uncertainties on the extracted proton form factors are evaluated using two different procedures. The results are consistent with those of a previous simulation study using an older, simplified framework. Furthermore, a slightly better precision is achieved in the PandaRoot study in a large range of momentum transfer, assuming the nominal beam conditions and detector performance.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

EPOP Diagnostics and Data Acquisition

This paper describes the diagnostics that have been selected for the first flight of the Electric Propulsion Orbital Platform (EPOP-1), in which a 1.8 kW hydrazine arcjet will be flown and tested on the Wake Shield Facility. These diagnostics are: Langmuir probe measurements and video of the arcjet plume; three types of electromagnetic noise measurements; measurement of the voltage-current characteristic of the arc at different feed pressures; and measurement of other performance parameters such as pressures and temperatures of arcjet system components, thrust, and specific impulse. Also, the approach to data acquisition and control of the experiment is described.

Ruyten, W. M.↗

Benchmark radar targets for the validation of computational electromagnetics programs

Results are presented of a set of computational electromagnetics validation measurements referring to three-dimensional perfectly conducting smooth targets, performed for the Electromagnetic Code Consortium. Plots are presented for both the low- and high-frequency measurements of the NASA almond, an ogive, a double ogive, a cone-sphere, and a cone-sphere with a gap.

Woo, Alex C.↗

A laboratory study of the electromagnetic bias of rough surface scattering by water waves

The design, development, and use of a focused-beam radar to measure the electromagnetic bias introduced by the scattering of radar waves by a roughened water surface are discussed. The bias measurements were made over wide ranges of environmental conditions in a wavetank laboratory. Wave-elevation data were provided by standard laboratory capacitance probes. Backscattered radar power measurements coincident in time and space with the elevation data were produced by the radar. The two data sets are histogrammed to produce probability density functions for elevation and radar reflectivity, from which the electromagnetic bias is computed. The experimental results demonstrate that the electromagnetic bias is quite variable over the wide range of environmental conditions that can be produced in the laboratory. The data suggest that the bias is dependent upon the local wind field and on the amplitude and frequency of any background wave field that is present.

Parsons, Chester L.↗

W-Band Transmission MeasurementS and X-Band Dielectric Properties Measurements for a Radome Material Sample

This paper describes measurements which were performed on a sample of radome material in the Electromagnetic Properties Measurements Laboratory (EPML). The purpose of the measurements described in this paper was to determine the one-way transmission loss through the flat panel of radome material for a frequency range of 84 to 94 GHz, for varying incidence angles. The panel, which was manufactured by Norton Performance Plastics Corporation, was provided to the EPML by TRW. The size of the panel is 40 in x 36 in x 0.422 in and consists of a foam material with one side coated with a smooth white coating (this side will be referred to as the front side). The dielectric properties of the foam material from the inside of the panel were also determined at X-band (8.2-12.4 GHz). The W-band free space measurements are presented first, followed by the X-band dielectric properties measurements.

Cravey, Robin L.↗

Description of an aircraft lightning and simulated nuclear electromagnetic pulse (NEMP) threat based on experimental data

Lightning data obtained by measuring the surface electromagnetic fields on a CV-580 research aircraft during 48 lightning strikes between 1500 and 18,000 feet in central Florida during the summers of 1984 and 1985, and nuclear electromagnetic pulse (NEMP) data obtained by surface electromagnetic field measurements using a 1:74 CV-580 scale model, are presented. From one lightning event, maximum values of 3750 T/s for the time rate of change of the surface magnetic flux density, and 4.7 kA for the peak current, were obtained. From the simulated NEMP test, maximum values of 40,000 T/s for the time rate of change of the surface magnetic flux density, and 90 A/sq m for the total normal current density, were found. The data have application to the development of a military aircraft lightning/NEMP standard.

Rustan, Pedro L., Jr.↗

Multi-frequency signatures of space-leader evolution in negative cloud-to-ground lightning stepped leaders

In this study, we examined 364 space leaders in 18 negative natural cloud-to-ground lightning strokes whose stepped leaders created new channels to ground. All strokes were captured on ultra-high-speed video cameras operating at frame rates ranging from 400k to 783k frames per second. Additionally, broadband electromagnetic field measurements were available for a subset of these strokes. The median space leader inception-to-attachment-point length and retrograde propagation speed towards the pre-existing leader channel (PELC) were 8.2 m and 4.0 x 10 6 m/s, respectively. Space leader lengths were longer and retrograde propagation speeds faster for return strokes with higher peak currents. This is likely due to the relative proximity of space leader inception points to the PELC, which makes the electric field produced by the PELC line charge density one of the primary factors in determining space leader characteristics. Space leader characteristics were weakly related to their inception altitude. We observed bursts of very high frequency (VHF) emissions preceding, by around 0.5 – 1 μs, electric field leader-step pulses; visible-frequency-range luminosity pulses started during the step pulses. The median downward leader propagation speed for all 18 strokes was 4.3 x 10 5 m/s; leader propagation speeds were generally faster for return strokes with higher peak currents. Also, leaders appeared to accelerate (on their way to ground) at altitudes lower than about 200 and 1000 m above ground level for strokes in the 10 – 60 and 84 – 228 kA peak current ranges, respectively.

54 ENVIRONMENTAL SCIENCES↗

Efficiency measurements of reflection gratings in the 100-300-A band

Zero-order and first-order efficiencies of plane diffraction grazings over the 100-300-A band have been measured using the NRL beamline facility at the National Synchrotron Light Source. Measurements were taken at grating angles of 5, 10, and 15 deg, and the incident radiation was polarized primarily in the transverse magnetic mode. Four (three laminar, one blazed) of the gratings were ion etched in high quality quartz blanks, overcoated with 200 A of gold. A fifth (blazed) grating was ruled in gold. The line densities are 1000, 2000, and 3600 grooves/mm for those with laminar profiles. Both blazed gratings have a blaze angle of 8 deg and line densities of 3600 grooves/mm. Measured first-order efficiencies up to 15 percent were obtained for the laminar gratings and up to 8 percent was obtained for the ion-etched blazed grating. Much lower efficiencies (not greater than 2 percent) were measured for the ruled grating. A computer program was written to calculate grating efficiencies using a full electromagnetic model. Measured efficiencies of the ion-etched gratings agree well with predicted values, but the measured first-order efficiency of the ruled grating is much lower than predicted.

Meekins, John F.↗

Radiation Pressure Measurements on Micron Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2 micron to 6.82 micron range and irradiating them from above with laser radiation focused to beam-widths of approx. 175-400 micron, at ambient pressures approx. 10(exp -3) to 10(exp -4) torr. The downward displacement of the particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of silica and the corresponding extinction and scattering efficiencies.

Abbas, M. M.↗

Radiation Pressure Measurements on Micron-Size Individual Dust Grains

Measurements of electromagnetic radiation pressure have been made on individual silica (SiO2) particles levitated in an electrodynamic balance. These measurements were made by inserting single charged particles of known diameter in the 0.2- to 6.82-micron range and irradiating them from above with laser radiation focused to beam widths of approximately 175- 400 microns at ambient pressures particle due to the radiation force is balanced by the electrostatic force indicated by the compensating dc potential applied to the balance electrodes, providing a direct measure of the radiation force on the levitated particle. Theoretical calculations of the radiation pressure with a least-squares fit to the measured data yield the radiation pressure efficiencies of the particles, and comparisons with Mie scattering theory calculations provide the imaginary part of the refractive index of SiO2 and the corresponding extinction and scattering efficiencies.

Abbas, M. M.↗

EMR Measurements on NDA Equipment

Electromagnetic radiation (EMR) emission strength measurements were performed on a suite of passive non-destructive assay (NDA) radiation detection equipment. Data were collected from 9 kHz up to 6 GHz on each of the assembled systems.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Frequency Dependence of an Electromagnetic Absorption Coefficient in Magnetic Fluid

The samples of water-based magnetic fluid, which contain Fe{sub 3}O{sub 4}–SiO{sub 2} particles with a spherical shape and sizes less than 100 nm, have been obtained. The method based on using a transmission line has been applied to measure the electromagnetic absorption coefficient in the frequency range from 0.1 to 18.0 GHz using a measuring setup based on horn antennas and the cell based on a coplanar transmission line. It has been found that magnetic fluids can be used to produce electromagnetic shields and electromagnetic wave absorbers as well as means to carry out local hyperthermia at electromagnetic radiation frequencies higher than 7 GHz.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Precision ephemerides for gravitational-wave searches. I. Sco X-1

Rapidly rotating neutron stars are the only candidates for persistent high-frequency gravitational wave emission, for which a targeted search can be performed based on the spin period measured from electromagnetic (e.g., radio and X-ray) observations. The principal factor determining the sensitivity of such searches is the measurement precision of the physical parameters of the system. Neutron stars in X-ray binaries present additional computational demands for searches due to the uncertainty in the binary parameters. We present the results of a pilot study with the goal of improving the measurement precision of binary orbital parameters for candidate gravitational wave sources. We observed the optical counterpart of Sco X-1 in 2011 June with the William Herschel Telescope and also made use of Very Large Telescope observations in 2011 to provide an additional epoch of radial-velocity measurements to earlier measurements in 1999. From a circular orbit fit to the combined data set, we obtained an improvement of a factor of 2 in the orbital period precision and a factor of 2.5 in the epoch of inferior conjunction T {sub 0}. While the new orbital period is consistent with the previous value of Gottlieb et al., the new T {sub 0} (and the amplitude of variation of the Bowen line velocities) exhibited a significant shift, which we attribute to variations in the emission geometry with epoch. We propagate the uncertainties on these parameters through to the expected Advanced LIGO-Virgo detector network observation epochs and quantify the improvement obtained with additional optical observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Coulomb Excitation and One-Neutron Transfer Studies of Stable and Radioactive Nuclei at HRIBF-ORNL

Several stable and radioactive nuclei ranging from $A=58$ to 208 were recently studied in inverse kinematics by Coulomb excitation and heavy-ion induced one-neutron transfer at the Holifield Radioactive Ion Beam Facility of Oak Ridge National Laboratory. These studies used a CsI-HPGe detector array to detect scattered charged particles and emitted $\gamma$ rays from the in-beam reactions. A Bragg-curve detector was used to measure the energy loss of the various beams through the targets and to measure the radioactive beam compositions. Stable nickel, strontium, zirconium, molybdenum, tin, tellurium, and lead isotopes and neutron-rich radioactive tin and tellurium isotopes were among the nuclei recently studied. Coulomb excitation was used to measure the electromagnetic moments of the first excited states and heavy-ion induced one-neutron transfer was used to measure the absolute cross sections and lifetimes of the excited single-particle states. A sample of these results are presented here with an emphasis on the tin isotopes. In particular, a survey of the Bragg-curve measurements, Doppler corrections, and inconclusive $i_{13/2}$ candidate in $^{133}$\textrm{Sn} are presented.

Allmond, James M↗

Sensing performance of sub-100-nm vanadium oxide films for room temperature thermal detection applications

Vanadium oxide films are widely employed as thermal detectors in uncooled infrared detection systems due to their high temperature coefficient of resistance near room temperature. One strategy toward maximizing detectivity and reducing the thermal time constant in these systems is to minimize the system platform dimensions. This approach necessitates thinner film thicknesses ([Formula: see text]100 nm), for which there is little information regarding thermal sensing performance. Herein, we report on the sensitivity of reactively sputtered vanadium oxide thin film resistive thermometers nominally ranging from 100 to 25 nm and assess the influence of thermal annealing. Here we demonstrate that films in this minimum limit of thickness maintain a high temperature coefficient while additionally providing an enhancement in characteristics of the noise equivalent power.

36 MATERIALS SCIENCE↗

A measurement technique to determine the calibration accuracy of an electromagnetic tracking system to radiation isocenter

Purpose: To present and characterize a measurement technique to quantify the calibration accuracy of an electromagnetic tracking system to radiation isocenter.Methods: This technique was developed as a quality assurance method for electromagnetic tracking systems used in a multi-institutional clinical hypofractionated prostate study. In this technique, the electromagnetic tracking system is calibrated to isocenter with the manufacturers recommended technique, using laser-based alignment. A test patient is created with a transponder at isocenter whose position is measured electromagnetically. Four portal images of the transponder are taken with collimator rotations of 45° 135°, 225°, and 315°, at each of four gantry angles (0°, 90°, 180°, 270°) using a 3 × 6 cm{sup 2} radiation field. In each image, the center of the copper-wrapped iron core of the transponder is determined. All measurements are made relative to this transponder position to remove gantry and imager sag effects. For each of the 16 images, the 50% collimation edges are identified and used to find a ray representing the rotational axis of each collimation edge. The 16 collimator rotation rays from four gantry angles pass through and bound the radiation isocenter volume. The center of the bounded region, relative to the transponder, is calculated and then transformed to tracking system coordinates using the transponder position, allowing the tracking system's calibration offset from radiation isocenter to be found. All image analysis and calculations are automated with inhouse software for user-independent accuracy. Three different tracking systems at two different sites were evaluated for this study.Results: The magnitude of the calibration offset was always less than the manufacturer's stated accuracy of 0.2 cm using their standard clinical calibration procedure, and ranged from 0.014 to 0.175 cm. On three systems in clinical use, the magnitude of the offset was found to be 0.053 ± 0.036, 0.121 ± 0.023, and 0.093 ± 0.013 cm.Conclusions: The method presented here provides an independent technique to verify the calibration of an electromagnetic tracking system to radiation isocenter. The calibration accuracy of the system was better than the 0.2 cm accuracy stated by the manufacturer. However, it should not be assumed to be zero, especially for stereotactic radiation therapy treatments where planning target volume margins are very small.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

High precision measurements of the proton elastic electromagnetic form factors and their ratio at 𝑄 2 = 0.50, 2.64, 3.20, and 4.10 GeV 2

The advent of high-intensity, high-polarization electron beams led to significantly improved measurements of the ratio of the proton’s charge to electric form factors, 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 . However, high-𝑄 2 measurements of this ratio yielded significant disagreement with extractions based on unpolarized scattering measurements, raising questions about the reliability of the measurements and consistency of the techniques. Jefferson Lab experiment E01-001 was designed to provide a high precision extraction of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 from unpolarized cross-section measurements using a modified version of the Rosenbluth separation technique to allow for a more precise comparison with polarization data. Rosenbluth separations involve precise measurements of the angular dependence of the elastic 𝑒−𝑝 cross section at fixed momentum transfer, 𝑄 2 . Conventional Rosenbluth separations detect the scattered electron, requiring the comparisons of measurements with very different detected electron energy and rate for electrons at different angles. Our ‘‘super-Rosenbluth’’ measurement detected the struck proton, rather than the scattered electron to extract the elastic 𝑒−𝑝 cross section. This yielded a fixed momentum for the detected particle and dramatically reduced variation of the cross section with angle, significantly reducing rate- and momentum-dependent corrections and uncertainties. We measure the cross section vs angle with high relative precision, allowing for extremely high precision extractions of 𝐺 𝐸⁢ 𝑝 ⁡/𝐺 𝑀⁢ 𝑝 at 𝑄 2 = 2.64, 3.20, and 4.10 GeV 2 . Our results are consistent with traditional Rosenbluth extractions, but with much smaller corrections and systematic uncertainties, comparable to the uncertainties from polarization measurements. Our data confirm the discrepancy between Rosenbluth and polarization extractions of the proton form factor ratio using an improved Rosenbluth extraction that yields smaller and less-correlated uncertainties than those typical of previous Rosenbluth extractions. Here, we compare our results to calculations of two-photon exchange effects and find that the observed discrepancy can be relatively well explained by such effects.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Microwave radiometric systems.

Microwave radiometers measure thermal electromagnetic radiation at frequencies ranging over the entire radio spectrum, from audio to infrared. The temperatures of black-body radiators can be measured with sensitivities better than 0.01 K, and with absolute accuracies better than 0.5 K. Radiometric systems have been built with as many as 400 independent spectral channels. Frequency resolutions range from hertz to gigahertz; and integration times range from microseconds to hours. Radiometric systems have operated reliably on the ground, and in balloons, aircraft, and spacecraft, including the 1962 Mariner 2 planetary probe to Venus.