Coalescence of GaP on V-Groove Si

With an increase of control over crystalline defects, metallorganic vapor phase epitaxy (MOVPE)-grown III-V-on-Si multijunction solar cells have seen rapid increases in efficiency in recent years, pointing to a promising path to lower cost III-V solar cells. However, the cost of chemo-mechanical polishing the Si wafers to prepare them for epitaxy is high. The use of V-groove nanopatterns enables similar defect reduction to that achieved on planar wafers, but the nanopatterns can be fabricated with a low-cost process. While V-grooves offer advantages over planar Si, they add complexity to the growth process. In particular, coalescence can cause the formation of threading dislocations, and the highly-directional growth conditions required for coalescence are unusual for MOVPE. We have studied the coalescence of GaP films nucleated directly on V-groove Si by MOVPE. We observed that for optimized growth conditions (V/III=5,000 and T=800 C) two growth modes were possible, and the resulting morphology depended on the exact geometry of the SiNx cap used to cover the (0 0 1)-oriented Si at the tops of the grooves. For caps with a width >100 nm, noncoalescing, nano ridge-like growth terminating in f1 1 1g facets was observed. For narrower caps, coalescence with an RMS roughness of 0.2 nm as measured by atomic force microscopy was observed. We will discuss mechanisms responsible for this phenomenon, including the role of Si from the substrate surface. The dislocation dynamics of this system were studied with electron channeling contrast imaging (ECCI) and transmission electron microscopy (TEM). We find that V-grooves do not block dislocation glide; ECCI measurements show misfit dislocations greater than 10 micrometers long observed to continue perpendicularly across neighboring V-grooves. In addition, all threading dislocations appear to lie on f1 1 1g planes, consistent with the GaP relaxing via glided-in glissile dislocations. The dislocation dynamics and morphological evolution of the coalescence of GaP on Si, possible mechanisms behind the observed phenomenons, and further dislocation mitigation strategies for these materials will be presented.

dislocation dynamics↗

Applying compressive sensing to TEM video: A substantial frame rate increase on any camera

One of the main limitations of imaging at high spatial and temporal resolution during in-situ transmission electron microscopy (TEM) experiments is the frame rate of the camera being used to image the dynamic process. While the recent development of direct detectors has provided the hardware to achieve frame rates approaching 0.1 ms, the cameras are expensive and must replace existing detectors. In this paper, we examine the use of coded aperture compressive sensing (CS) methods to increase the frame rate of any camera with simple, low-cost hardware modifications. The coded aperture approach allows multiple sub-frames to be coded and integrated into a single camera frame during the acquisition process, and then extracted upon readout using statistical CS inversion. Here we describe the background of CS and statistical methods in depth and simulate the frame rates and efficiencies for in-situ TEM experiments. Depending on the resolution and signal/noise of the image, it should be possible to increase the speed of any camera by more than an order of magnitude using this approach.

36 MATERIALS SCIENCE↗

Nanoscale Free-Electron Lasing (Final Technical Report)

Optical control of electron dynamics and energy structure can be leveraged for tailoring classical and quantum light sources. Previous work was primarily limited to Transmission Electron Microscopes (TEMs). Our work under this program sought to enable full time and energy control of electrons in SEMs for exploring the physics of attosecond electron dynamics and light generation at the nanoscale. The motivation behind this work was to understand these fundamental processes important to free-electron lasing at the nanoscale using sub-relativistic electrons.

42 ENGINEERING↗

Chemoselective Hydrogenation with Supported Organoplatinum(IV) Catalyst on Zn(II)-Modified Silica

For this research, well-defined organoplatinum(IV) sites were grafted on a Zn(II)-modified SiO 2 support via surface organometallic chemistry in toluene at room temperature. Solid-state spectroscopies including XAS, DRIFTS, DRUV–vis, and solid-state (SS) NMR enhanced by dynamic nuclear polarization (DNP), as well as TPR-H 2 and TEM techniques revealed highly dispersed (methylcyclopentadienyl)methylplatinum(IV) sites on the surface ((MeCp)PtMe/Zn/SiO 2 , 1). In addition, computational modeling suggests that the surface reaction of (MeCp)PtMe 3 with Zn(II)-modified SiO 2 support is thermodynamically favorable (ΔG = -12.4 kcal/mol), likely due to the increased acidity of the hydroxyl group, as indicated by NH 3 -TPD and DNP-enhanced 17 O{ 1 H} SSNMR. In situ DRIFTS and XAS hydrogenation experiments reveal the probable formation of a surface Pt(IV)-H upon hydrogenolysis of Pt-Me groups. The heterogenized organoplatinum(IV)-hydride sites catalyze the selective partial hydrogenation of 1,3-butadiene to butenes (up to 95%) and the reduction of nitrobenzene derivatives to anilines (up to 99%) with excellent tolerance of reduction-sensitive functional groups (olefin, carbonyl, nitrile, halogens) under mild reaction conditions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real time nanoscale structural evaluation of gold structures on Si (100) surface using in-situ transmission electron microscopy

Transport behavior of gold nanostructures on Si(100) substrate during annealing under high vacuum has been investigated using in-situ real time transmission electron microscopy (TEM). A comparative study has been done on the morphological changes due to annealing under different vacuum environments. Au thin films of thickness ∼2.0 nm were deposited on native oxide covered silicon substrate by using thermal evaporation system. In-situ real time TEM measurements at 850 °C showed the isotropic growth of rectangular/square shaped gold-silicon alloy structures. During the growth, it is observed that the alloying occurs in liquid phase followed by transformation into the rectangular shapes. For similar system, ex-situ annealing in low vacuum (10{sup −2} millibars) at 850 °C showed the spherical gold nanostructures with no Au-Si alloy formation. Under low vacuum annealing conditions, the rate of formation of the oxide layer dominates the oxide desorption rate, resulting in the creation of a barrier layer between Au and Si, which restricts the inter diffusion of Au in to Si. This work demonstrates the important role of interfacial oxide layer on the growth of nanoscale Au-Si alloy structures during the initial growth. The time dependent TEM images are presented to offer a direct insight into the fundamental dynamics of the sintering process at the nanoscale.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Rapid misfit dislocation characterization in heteroepitaxial III-V/Si thin films by electron channeling contrast imaging

Electron channeling contrast imaging (ECCI) is used to characterize misfit dislocations in heteroepitaxial layers of GaP grown on Si(100) substrates. Electron channeling patterns serve as a guide to tilt and rotate sample orientation so that imaging can occur under specific diffraction conditions. This leads to the selective contrast of misfit dislocations depending on imaging conditions, confirmed by dynamical simulations, similar to using standard invisibility criteria in transmission electron microscopy (TEM). The onset and evolution of misfit dislocations in GaP films with varying thicknesses (30 to 250 nm) are studied. This application simultaneously reveals interesting information about misfit dislocations in GaP/Si layers and demonstrates a specific measurement for which ECCI is preferable versus traditional plan-view TEM.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Nanomechanical testing of freestanding polymer films: in situ tensile testing and Tg measurement

Abstract A method for small-scale testing and imaging of freestanding, microtomed polymer films using a push-to-pull device is presented. Central to this method was the development of a sample preparation technique which utilized solvents at cryogenic temperatures to transfer and deposit delicate thin films onto the microfabricated push-to-pull devices. The preparation of focused ion beam (FIB)-milled tensile specimens enabled quantitative in situ TEM tensile testing, but artifacts associated with ion and electron beam irradiation motivated the development of a FIB-free specimen preparation method. The FIB-free method was enabled by the design and fabrication of oversized strain-locking push-to-pull devices. An adaptation for push-to-pull devices to be compatible with an instrumented nanoindenter expanded the testing capabilities to include in situ heating. These innovations provided quantitative mechanical testing, postmortem TEM imaging, and the ability to measure the glass transition temperature, via dynamic mechanical analysis, of freestanding polymer films. Results for each of these mentioned characterization methods are presented and discussed in terms of polymer nanomechanics. Graphic Abstract

36 MATERIALS SCIENCE↗

Single-molecule 3D imaging of HIV cellular entry by liquid-phase electron tomography

Enveloped viruses, including human immunodeficiency virus (HIV) and SARS-CoV-2, target cells through membrane fusion process. The detailed understanding of the process is sought after for vaccine development but remains elusive due to current technique limitations for direct three-dimensional (3D) imaging of an individual virus during its viral entry. Recently, we developed a simple specimen preparation method for real-time imaging of metal dynamic liquid-vaper interface at nanometer resolution by transmission electron microscopy (TEM). Here, we extended this method to study biology sample through snapshot 3D structure of a single HIV (pseudo-typed with the envelope glycoprotein of vesicular stomatitis virus, VSV-G) at its intermediate stage of viral entry to HeLa cells in a liquid-phase environment. By individual-particle electron tomography (IPET), we found the viral surface release excess lipids with unbound viral spike proteins forming ~50-nm nanoparticles instead of merging cell membrane. Moreover, the spherical-shape shell formed by matrix proteins underneath the viral envelope does not disassemble into a cone shape right after fusion. Further, the snapshot 3D imaging of a single virus provides us a direct structure-based understanding of the viral entry mechanism, which can be used to examine other viruses to support the development of vaccines combatting the current ongoing pandemic.

Kong, Lingli↗

Radiation Damage in Materials—Helium Effects

Despite its scarcity in terrestrial life, helium effects on microstructure evolution and thermo-mechanical properties can have a significant impact on the operation and lifetime of applications, including: advanced structural steels in fast fission reactors, plasma facing and structural materials in fusion devices, spallation neutron target designs, energetic alpha emissions in actinides, helium precipitation in tritium-containing materials, and nuclear waste materials. The small size of a helium atom combined with its near insolubility in almost every solid makes the helium–solid interaction extremely complex over multiple length and time scales. This Special Issue, “Radiation Damage in Materials—Helium Effects”, contains review articles and full-length papers on new irradiation material research activities and novel material ideas using experimental and/or modeling approaches. These studies elucidate the interactions of helium with various extreme environments and tailored nanostructures, as well as their impact on microstructural evolution and material properties.

36 MATERIALS SCIENCE↗

Direct Observation of Tungsten Oxidation Studied by In Situ Environmental TEM

In this study, in situ environmental transmission electron microscopy (ETEM) was applied, for the first time, to investigate the thermal oxidation of a pristine and a self-ion irradiated polycrystalline tungsten, using a MEMS-based gas cell at 500 oC to 900 oC in a 1 bar 2%O2/N2 gas mixture. By tracking the dynamic evolution of the tungsten oxide scale as it initiates, grows, and sublimates during a consecutive thermal oxidation experiment, we observed two distinctive tungsten oxide microstructure – one nanocrystalline o-WO3 scale grown on W{27-1 } and W{1-1 8} and another o-WO3 scale exhibits a novel highly textured nanostructure. While the two oxide microstructures shared a similar thickness of ~200 nm after 40-minute early-stage oxidation, the nanocrystalline scale on the W{27-1 } grew much more rapidly at 800 oC than the highly textured oxide at a higher temperature of 900 oC. This suggests both the microstructure of these tungsten oxide scales as well as their oxidation kinetics are highly sensitive to the tungsten surface orientation, and such correlations also change dynamically in the course of oxidation. We also discuss the tungsten oxidation mechanism, the effects of the TEM foil thickness, and the focused ion beam (FIB) Ga+ damage on in situ ETEM oxidation.

In situ ETEM, Tungsten, Thermal oxidation, Orienta↗

A self-healing plastic ceramic electrolyte by an aprotic dynamic polymer network for lithium metal batteries

Abstract Oxide ceramic electrolytes (OCEs) have great potential for solid-state lithium metal (Li 0 ) battery applications because, in theory, their high elastic modulus provides better resistance to Li 0 dendrite growth. However, in practice, OCEs can hardly survive critical current densities higher than 1 mA/cm 2 . Key issues that contribute to the breakdown of OCEs include Li 0 penetration promoted by grain boundaries (GBs), uncontrolled side reactions at electrode-OCE interfaces, and, equally importantly, defects evolution (e.g., void growth and crack propagation) that leads to local current concentration and mechanical failure inside and on OCEs. Here, taking advantage of a dynamically crosslinked aprotic polymer with non-covalent –CH 3 ⋯CF 3 bonds, we developed a plastic ceramic electrolyte (PCE) by hybridizing the polymer framework with ionically conductive ceramics. Using in-situ synchrotron X-ray technique and Cryogenic transmission electron microscopy (Cryo-TEM), we uncover that the PCE exhibits self-healing/repairing capability through a two-step dynamic defects removal mechanism. This significantly suppresses the generation of hotspots for Li 0 penetration and chemomechanical degradations, resulting in durability beyond 2000 hours in Li 0 -Li 0 cells at 1 mA/cm 2 . Furthermore, by introducing a polyacrylate buffer layer between PCE and Li 0 -anode, long cycle life >3600 cycles was achieved when paired with a 4.2 V zero-strain cathode, all under near-zero stack pressure.

36 MATERIALS SCIENCE↗

Equilibration of Imine-Linked Polymers to Hexagonal Macrocycles Driven by Self-Assembly

Macrocyclesbased on directional bonding and dynamic covalentbond exchange can be design ed with specificpore shapes, sizes, andfunctionality.These sys- tems retain many of the design criteria and desirableas- pects of two-dimensional (2D) covalent organic frame- works (COFs)but are more easily processed. Here we access discrete hexagonal imine-linked macrocycles by condensing atruncated analogueof1,3,5-tris(4-aminophe- nyl)benzene(TAPB) with terephthaldehyde (PDA). The monomers first condense into polymers buteventually convertinto hexagonal macrocycles in high yield. The high selectivity for hexagonal macrocycles is enforcedby their aggregation and crystallization into layered struc- tures with more sluggish imine exchange. Their formation and exchange processes provide new insight into how imine-linked 2D COF simultaneously polymerize and crys- tallize. Solutions of theseassembled macrocycles were cast into oriented, crystalline films, expanding the poten- tial routes to 2D materials.

covalent organic frameworks↗

Modification of the SAS4A Safety Analysis Code for Integration with the ADAPT Discrete Dynamic Event Tree Framework.

It is difficult to assess the consequences of a transient in a sodium-cooled fast reactor (SFR) using traditional probabilistic risk assessment (PRA) methods, as numerous safety-related sys- tems have passive characteristics. Often there is significant dependence on the value of con- tinuous stochastic parameters rather than binary success/failure determinations. One form of dynamic PRA uses a system simulator to represent the progression of a transient, tracking events through time in a discrete dynamic event tree (DDET). In order to function in a DDET environment, a simulator must have characteristics that make it amenable to changing physical parameters midway through the analysis. The SAS4A SFR system analysis code did not have these characteristics as received. This report describes the code modifications made to allow dynamic operation as well as the linking to a Sandia DDET driver code. A test case is briefly described to demonstrate the utility of the changes.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Compressive Classification for TEM-EELS

Acquiring atomic-resolution images of beam sensitive materials or under dynamic conditions (e.g. operando STEM) is very difficult and requires precise dose fractioning to minimize the dose delivered to the sample and acquire the data more rapidly than dynamics present. Typical methods of low-dose STEM imaging include adjusting the beam current, dwell-time, and probe Scanning transmission electron microscopy (STEM) is used routinely to obtain atomic-resolution images of a small selection of radiation tolerant materials under stable conditions.size. All three of these determine the dose over a spatial area in STEM. Recently, compressive sensing [1] has been applied to electron microscopy. The computational imaging method of inpainting [2] has been proposed as a method to reduce dose and increase acquisition speed for STEM. Inpainting is a technique to recover missing pixels in an image. By skipping pixels (randomly) during acquisition, a fourth dose-control mechanism is realized [3]. A few implementations of randomly-subsampled STEM exist (e.g., [4]). To make the concepts of compressive sensing accessible to the microscopy community we begin with an example using atomic resolution images of a GaAs crystal (see Figure 1). Because the crystal is periodic it has a sparse representation in reciprocal space. In fact, a sparse representation is a key component of compressive sensing. If an image is sub-sampled randomly we find that the Fourier transform remains sparse, but becomes increasing noisy as less and less data is acquired. Yet, by finding the peaks in the reciprocal image and removing the noise it is possible to recover atomic resolution images with only 1% of the pixels. Figure 1 shows the reconstruction process for GaAs sub-sampled at 50%, 10%, 5%, and 1%. Periodic images form a special class for which the optimal sampling approach (according to CS theory) is a random selection of pixels. For non-periodic images, such as those arising in in-situ STEM, methods such as dictionary learning are necessary [2,5]. The data can be compressed in time for TEM [5] or pixels can be skipped randomly for STEM. There are several issues that arise in developing a random scan for STEM [4] and a coded aperture for TEM. The remainder of the talk will address these issues. References: [1] E Candes and M Wakin. Signal Processing Magazine, IEEE. 2(25) (2008), pp. 21. [2] A Stevens, Pu Y, Sun Y, et al. Artificial Intelligence & Statistics (AISTATS), 2017. [3] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [4] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016). [5] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [6] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Hao, Weituo↗

One-Dimensional Nanostructures for Neutron Detection

This report consists of four parts in addition to a publication/presentation list. Part I is on electronic structure simulations on boron nitride (BN) and BC x N nanotubes using density function theory (DFT), Part II is on fabrication and characterization of nanowire sensors, Part III is on irradiation response of BN nanotubes using molecular dynamics (MD) simulations, and Part IV is on the in-situ transmission electron microscopy (TEM) study of irradiation response of BN nanotubes.

36 MATERIALS SCIENCE↗

Reducing Radiation Damage Using Pulsed Electron Beams in the TEM

A rise in the development and the use of ultrashort-pulsed sources (i.e., femtosecond to picosecond) in transmission electron microscopes (TEMs) has led to numerous discoveries and paradigm tests of atomic to nanoscale structural dynamics well beyond the temporal limits of fast detectors. Vital to these advances are precise control over the electron emission process, typically via the photoelectric effect, or via temporal modulation of an initially continuous beam swept across an aperture. In addition to enabling ultrafast pump-probe experiments, fine control over the emission process allows for exploration of the effects of such pulsed beams on damage sustained by the specimen during observation. Unlike proposed diffract-before-destroy methods with electrons, these approaches would ideally be applied in the single-electron-per-packet regime, with sufficient time between the arrival of each electron at the specimen for all reversible energy-deposition events to fully recover. Indeed, some intriguing results using pulsed electron beams in TEMs have been reported here, including effects on the structure of catalyst particles and apparent prolonged exposures for polymer crystals

61 RADIATION PROTECTION AND DOSIMETRY↗

Evolution of dislocation loops in irradiated α-Uranium: An atomistically-informed cluster dynamics investigation

An atomistically-informed mean field cluster dynamics model has been developed to investigate the nucleation and growth of prismatic loops in irradiated a-Uranium. TEM analysis of neutron irradiated a-Uranium shows the evolution of self-interstitial atom and vacancy loops on (010) and (100) crystallographic planes, respectively, resulting in an anisotropic lattice swelling of its face-centered orthorhombic crystal. To provide model parameters, the crystallography of loops and the binding energy of point defects to these loops were studied using an angular dependent EAM potential and classical molecular dynamics (MD) simulations. Furthermore, using the bond-boost hyperdynamics method, the anisotropic diffusion of interstitials and vacancies in a-Uranium was investigated. Here, the mechanisms of point defect diffusion and the associated migration energies were reported and compared with previous DFT studies. The energetics and kinetic quantities mentioned above were used in the cluster dynamics model to predict the cluster density as a function of dose rate, dose and temperature and the results were compared to the reported neutron irradiation experiments. The model predictions reveal an accumulation of small sized vacancy loops along with a population of large and growing self-interstitial loops, which closely corresponds to the TEM observations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗