Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose rates”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Transient Photocurrent From High-Voltage Vertical GaN Diodes Irradiated With Electrons: Experiments and Simulations

Radiation-hard high-voltage vertical GaN p-n diodes are being developed for use in power electronics subjected to ionizing radiation. Here, we present a comparison of the measured and simulated photocurrent response of diodes exposed to ionizing irradiation with 70 keV and 20 MeV electrons at dose rates in the range of 1.4x10 7 - 5.0x10 8 rad(GaN)/s. The simulations correctly predict the trend in measured steady-state photocurrent and agree with experimental results within a factor of 2. Furthermore, simulations of the transient photocurrent response to dose rates with uniform and non-uniform ionization depth profiles uncover the physical processes involved that cannot be otherwise experimentally observed due to orders of magnitude larger RC time constant of the test circuit. The simulations were performed using an Exploratory Physics Development code developed at Sandia National Laboratories. The code offers the capability to include defect physics under more general conditions, not included in commercially available software packages, extending the applicability of the simulations to different types of radiation environments.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of Irradiation on Corrosion Performance of Hybrid Organic/Inorganic Coatings on Austenitic Stainless Steel

The effects of gamma radiation on the performance of two corrosion-resistant coatings applied to stainless-steel 304L (SS304L) surfaces are presented. Specifically, the ability of the coatings to mitigate corrosion of SS304L surfaces as a function of the dose received (0–1300 Mrad) and dose rate (176 compared to 1054 rad/s) is evaluated using electrochemical methods, spectroscopy, and microscopy. Coating A, an organic/inorganic hybrid coating consisting of a two-part silica ceramic component and a polymer linker was evaluated in comparison to Coating B, which utilized Coating A as a topcoat for a commercial, off-the-shelf, Zn-rich primer. Post irradiation, Coating A demonstrated some corrosion protection following exposure to low levels of gamma radiation, but coating degradation occurred with an increased exposure dose and resulted in isolated regions of corrosion initiation. For Coating B, greater corrosion resistance was observed compared to Coating A due to the sacrificial nature of the Zn at elevated doses of gamma radiation. No effect of the dose rate (for the single dose examined) was observed for either coating. It is proposed for Coating B that as the polymer coating thermally degrades above 250 °C (bond scission of the polymer occurs), the remaining Zinc layer adhered to the SS304L post-irradiation enables enhanced corrosion resistance as compared to Coating A, which displays solely polymer degradation. The results presented herein establish an understanding of coating behavior with radiation exposure, specifically the relationship between corrosion coating performance and radiation dose, and can inform ageing and lifetime management for various applications.

degradation↗

Characterization Strategy of a Limited Number of Radioactive Waste Effluent Tanks in View of Decommissioning a Large Number of Tanks - 20286

In order to organize the D and D of the former effluent treatment facility at the CEA Cadarache Center (France), the key data to gather through the facility characterization are the following:: volumes and masses, liquid/solid distribution and specific activity. By studying the treatment processes and the history of the facility, families of tanks have been defined and a reference tank chosen for investigation in each family. The intrusive investigations (video, residue thickness, dose rate..), the gamma spectrometry measurements carried out on site on the residue samples and radiochemical results collected in laboratories, led us to conclude that there was a relative radiological homogeneity (for specific activity and Am-241/Cs-137 ratio) within each tank. The next step consisted in extrapolating the specific activity evaluated for the reference tanks, to the other tanks of each family by using data such as geometry, dose rate or the function of the tanks within the process. Thus, a cartography of the 130 tanks of the facility is available. Finally, the conclusions drawn from the radiological homogeneity of the tanks and their affiliation to homogeneous, well-identified tank clusters lead to a simple and efficient operational approach for the D and D of the 130 tanks of the facility. Indeed, because of the residue characteristics (homogeneous activity and strong differentiation of Cs/Am ratio), a sample collected when opening the tank, and measured on site by gamma spectrometry will allow us to validate the operational design and the emptying techniques defined during the D and D study phase thanks to the characterization of a limited number of reference tanks. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Dynamic Testing of a Commercial FRAM Device Under Gamma Ray Dose and Neutron Beam

Here, this work presents dose rate and neutron testing on a ferroelectric random-access memory (FRAM) device in dynamic operation during radiation pulses. Radiation failure modes are shown to be unique. Dose rate failure is shown to be based primarily on integrated dose in the radiation pulse and terminates the FRAM operation and can alter up to 8 bytes of data in storage. Neutron failures are attributed to a shifting of data like a clocking error.

Harris, Nathan↗

Cluster dynamics modeling of Mn-Ni-Si precipitates coupled with radiation-induced segregation in low-Cu reactor pressure vessel steels

Formation of precipitates enhanced or induced by irradiation causes hardening and embrittlement of nuclear structural materials. Post-irradiation microstructure characterization of reactor pressure vessel (RPV) steels has shown that precipitation can be strongly associated with radiation-induced segregation (RIS) of solutes on dislocations. However, RIS and precipitation have not been coupled in previous precipitation modeling of RPV steels. Here in this study, a new hybrid and spatially-dependent precipitation model is developed that couples cluster dynamics with RIS, providing an unique way to account for concurrent evolution of heterogeneous cluster densities as well as solute and point defect concentration profiles. The model is applied to study the segregation of Mn, Ni, and Si on dislocations and heterogeneous nucleation of Mn-Ni-Si rich precipitates (MNSPs) in a low-Cu RPV steel. The result shows that the onset of MNSP nucleation on dislocations occurs at the fluence of 2 x 10 23 n.m -2 . The number density and mean radius can reach ~ 10 24 m -3 and 1-2 nm at high fluence, respectively. These observations suggest that the role of RIS and heterogeneous nucleation can be significant for RPV steels under a high fluence of irradiation. Results of simulations adopting various dose rates and dislocation densities show an increased fraction of MNSPs on dislocations at the condition of low dose rate, high dislocation density, and high fluence.

36 MATERIALS SCIENCE↗

Integrating HPC simulations and physical experiments to characterize the effects of gamma radiation on seismic protective devices

Seismic protective systems, composed of seismic isolators and dampers, can substantially reduce the effects of earthquake shaking on nuclear power plants and components therein. To enable the use of these devices to protect equipment inside a plant and close to a source of radiation, the U.S. Department of Energy (DOE) funded a project at the Idaho National Laboratory (INL) and the University at Buffalo to characterize the effects of absorbed gamma dose on their mechanical properties. An early task in the project was to determine the exposure time required in the INL Foss Therapy Services (FTS) 60 Co gamma irradiator to achieve a target absorbed dose in the materials used to construct isolators and dampers, including fluids, polymers, composites, and metals. This task required the novel integration of high-performance computing (HPC), Monte Carlo N-Particle (MCNP) simulations, and irradiation experiments using Fricke dosimetry. An MCNP model of the FTS irradiator at INL was developed and validated using Fricke dosimetry. Simulations of three experiments in the irradiator, two with Fricke vials only and one with Fricke vials and a large-size isolator, predicted the Fricke-measured absorbed dose rate to within 15% in all three cases, providing high confidence in the calculation of the gamma dose absorbed in the materials comprising the seismic protective devices. The simulations demonstrated that the effects of photon scattering on absorbed dose rate in the FTS irradiator are negligible for test articles installed close to the cobalt sources and near the rear of the irradiator. The validated MCNP model of the FTS irradiator is being used to support ongoing DOE-funded experiments on seismic protective devices and could be applied to future, non-seismic-related experiments. In conclusion, the novel validation process successfully deployed for the FTS irradiator at INL could be applied to other irradiators, requiring new MCNP models and simulations, and irradiation experiments using dosimeters.

42 - ENGINEERING↗

Shielding Thickness Recommendations for an Activated Target Segment Vertical Stave

This analysis examines the shielding requirements needed to plan maintenance and handling operations of the target segment assembly vertical stave. It provides the analyses and results that fulfill the requirements of Task Order TO-150. The vertical stave is a stainless-steel welded assembly that carries cooling water to and from the target block. In this report, we characterize the dose rates and shielding requirements for the vertical stave only, i.e., separated from the target block. Shielding and dose rates for the target block only have been calculated in response to TO-008.

61 RADIATION PROTECTION AND DOSIMETRY↗

Deinococcus radiodurans UWO298 Dependence on Background Radiation for Optimal Growth

Ionizing radiation is a major environmental variable for cells on Earth, and so organisms have adapted to either prevent or to repair damages caused by it, primarily from the appearance and accumulation of reactive oxygen species (ROS). In this study, we measured the differential gene expression in Deinococcus radiodurans UWO298 cultures deprived of background ionizing radiation (IR) while growing 605 m underground at the Waste Isolation Pilot Plant (WIPP), reducing the dose rate from 72.1 to 0.9 nGy h –1 from control to treatment, respectively. This reduction in IR dose rate delayed the entry into the exponential phase of the IR-shielded cultures, resulting in a lower biomass accumulation for the duration of the experiment. The RNASeq-based transcriptome analysis showed the differential expression of 0.2 and 2.7% of the D. radiodurans genome after 24 and 34 h of growth in liquid culture, respectively. Gene expression regulation after 34 h was characterized by the downregulation of genes involved in folding newly synthesized and denatured/misfolded proteins, in the assimilation of nitrogen for amino acid synthesis and in the control of copper transport and homeostasis to prevent oxidative stress. We also observed the upregulation of genes coding for proteins with transport and cell wall assembly roles. These results show that D. radiodurans is sensitive to the absence of background levels of ionizing radiation and suggest that its transcriptional response is insufficient to maintain optimal growth.

59 BASIC BIOLOGICAL SCIENCES↗

Strategy to safely enable X-ray computed tomography examination of highly radioactive tristructural isotropic nuclear fuel

Nondestructive post-irradiation examination of nuclear fuels and materials is useful in collecting data to inform commercial licensing of new nuclear concepts. This work details the planning, shielding design, and workflow of an X-ray computed tomography examination of an irradiated AGR-5/6/7 fuel compact with a dose rate of 1318 R/hr on contact from both β and ɤ-ray radiation with 120 R/hr of the dose rate coming exclusively from ɤ-rays. Post-irradiation examination of highly radioactive samples can help reduce the timeframe from conceptualization of novel nuclear concepts to their commercial implementation as not only is less time spent waiting for experiments to decay away to acceptable levels for examinations, but data from these experiments can more quickly inform model efforts and subsequent experiments. While this work represents the hottest radiological sample that has been openly transported and examined at Idaho National Laboratory’s Irradiated Materials Characterization Laboratory to date, it is anticipated that this work and its lessons learned will facilitate future examinations of similar or even more radioactive specimens.

42 - ENGINEERING↗

Heterogeneity effects on nondestructive assay measurements of enrichment in UF 6 cylinders

A set of measurements were performed using multiple mechanically cooled HPGe detectors at six positions around a cylinder uranium hexafluoride to assess if matrix inhomogeneity is detectible and effects the determined apparent uranium enrichment. These measurements were performed on nine 30B cylinders of uranium hexafluoride. Six of the cylinders appeared to be homogeneous and had similar apparent measured uranium enrichment, as calculated by the FRAM software, at all positions. However, three cylinders appeared to have local inhomogeneity based on the observed results. This was manifested as very low apparent enrichments, often <10% of the declared enrichment, on select positions. The side with a low apparent enrichment shows elevated daughter isotope activity (e.g., elevated 1001 keV and 766 keV peak count rate) and slightly reduced 235 U activity (lower 185.7 keV count rate). We hypothesize that these heterogenous cylinders may have experienced asymmetric solar heating, which caused volatile UF 6 to sublime preferentially away from the warmed side. A similar phenomenon was observed at a second facility where dose rate measurements confirm that the “low-enriched side” of cylinders show elevated gamma ray dose rates, likely from the removal of UF 6 attenuation and concentration of daughter-products. Care should be taken during uranium enrichment verification when applying methods that include gamma-rays associated with daughter nuclides to the determination of uranium enrichment on cylinders that are stored in sunlight and have asymmetric dose readings around the cylinder.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

SCALE 6.3.1 Radiation Source Terms and Shielding Analysis for a Postulated Sodium-Cooled Fast Reactor Accident Scenario

In support of the US Nuclear Regulatory Commission non–light-water reactor fuel cycle demonstration project, SCALE 6.3.1 capabilities for radiation source term and shielding calculations are demonstrated for scenarios in the sodium-cooled fast reactor (SFR) fuel cycle. A postulated accident scenario, which consists of a seismic event causing the refueling machine to fall and release a spent fuel assembly inside the containment building (CB), is analyzed in this paper. Radiation source terms were generated for a U/TRU-10Zr metal fuel assembly with a 16.5% initial transuranic waste content and a discharge burnup of approximately 95 GWd/tHM; source terms were also generated for a high-assay low-enriched uranium metal fuel assembly (U-10Zr) with a 16.5% initial enrichment and a discharge burnup of 149.74 GWd/tHM. These radiation source terms were then used to determine the dose rate inside the CB and near the outer surface of the CB for a range of spent fuel assembly cooling times. The dose rate produced by the analyzed SFR assemblies is similar to that produced by a typical pressurized water reactor assembly with a discharge burnup of 50 GWd/MTU. Ultimately, the validation of the source terms predicted for SFRs with SCALE will need to be demonstrated via the use of assay measurements.

Radulescu, Georgeta↗

Temperature and dose effects on dislocation loops in self-ion irradiated high-purity iron

Body-centered cubic (BCC) Fe-based alloys are promising candidate materials for advanced nuclear reactors. However, a detailed understanding of irradiation induced dislocation loop microstructure development remains unresolved. It is a widespread belief that 〈001〉 loops become increasingly favorable over ½〈111〉 loops as irradiation temperature rises above ∼300 C. Unfortunately, the temperature effects on 〈001〉 loop have been primarily examined in in-situ irradiation on TEM thin foils but poorly explored on bulk Fe due to exceedingly limited experimental studies on bulk specimens, raising concerns about the potential influence of TEM thin foil artifacts on observed results. Here, in this study, we conducted experiments on ultra-high purity BCC Fe specimens irradiated with 6.7–8 MeV Fe ions over a wide temperature range on bulk samples. We investigated the effects of temperature (T irr = 250–500 °C), dose rate (10⁻⁵ to 10⁻³ dpa/s), and dose (0.35 to 3.5 dpa) on the formation and evolution of 〈001〉 and ½〈111〉 loops as well as cavity (void) formation. Post-irradiation Burgers vector analysis via g•b method on dislocation segments and loops revealed that 〈001〉 loop fraction does not show a monotonic positive correlation with irradiation temperature. Combined with previous and current theoretical as well as experimental findings, we explore the temperature effects on all existing models of 〈001〉 loop formation. We conclude that the prevailing reports regarding the dominance of 〈001〉 loops in Fe at elevated temperatures are mainly attributable to the loss of glissile ½〈111〉 clusters in TEM thin foil experiments.

36 MATERIALS SCIENCE↗

Determination of energy correction coefficient for neutron albedo dosimeter. Three approaches

To accurately determine dose, albedo TLD dosimeters require application of a neutron energy correction factor (NECF). Here, in this paper, the results from three different methods were used to determine NECFs. In the first method, NECF values were calculated as a ratio of the known “conventional true” dose and the neutron dose reported by albedo dosimeter(s) irradiated on a phantom. The results from this direct method were utilized for verification of two other methods. The second method used a specially designed device called the Neutron Area Monitor (NAM) model 5. The third method of NECF determination was based on the response of a BF 3 tube under different levels of moderation. The results of this work showed that the Navy-developed Neutron Area Monitor (NAM) model 5 measures NECF values correctly when irradiated with 252 Cf (bare and D 2 O-moderated). This was an important result, because it validated the use of the NAM-5 in nuclear power and marine propulsion reactors, as their neutron energy spectrum is approximated by the field of a Cadmium-coated 30 cm diameter steel sphere of D 2 O moderated 252 Cf. In the case of a broad neutron energy spectrum the 6 Li response to the small amount of slow neutrons outweighs its response to the fast neutrons overwhelmingly responsible for the neutron dose rate. Based on the obtained results we can conclude that NAM-5 provides correct NECF determination if the fraction of slow neutrons in the neutron dose rate is more than 20%. A satisfactory correlation between the NECF determined by NAM-5 and the multi-moderated BF3 tube method was observed, but the multi-moderated BF 3 tube values were ~30% lower than those obtained by the NAM-5 at the same locations for broader neutron energy spectrum locations.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Findings during Incorporation of the Federal Guidance Report No. 15 External Dose Coefficients into the RESRAD Family of Codes

Argonne National Laboratory was tasked by the U.S. Department of Energy (DOE) to incorporate the recently published Federal Guidance Report No. 15 (FGR 15) (EPA 2019) external dose rate coefficients into the database of the RESRAD family of codes. FGR 15 is one of two publications that contain age-specific external effective dose rate coefficients that are based on the International Commission on Radiological Protection (ICRP) Publication 103 (ICRP-103) methodology (ICRP 2007) and the ICRP-107 (ICRP 2008) nuclear decay data; ICRP-144 (ICRP 2020) is the other publication.

61 RADIATION PROTECTION AND DOSIMETRY↗

Space radiation measurements during the Artemis I lunar mission

Space radiation is a notable hazard for long-duration human spaceflight. Associated risks include cancer, cataracts, degenerative diseases and tissue reactions from large, acute exposures. Space radiation originates from diverse sources, including galactic cosmic rays, trapped-particle (Van Allen) belts5 and solar-particle events. Previous radiation data are from the International Space Station and the Space Shuttle in low-Earth orbit protected by heavy shielding and Earth’s magnetic field and lightly shielded interplanetary robotic probes such as Mars Science Laboratory and Lunar Reconnaissance Orbiter. Limited data from the Apollo missions and ground measurements with substantial caveats are also available. Here we report radiation measurements from the heavily shielded Orion spacecraft on the uncrewed Artemis I lunar mission. At differing shielding locations inside the vehicle, a fourfold difference in dose rates was observed during proton-belt passes that are similar to large, reference solar-particle events. Interplanetary cosmic-ray dose equivalent rates in Orion were as much as 60% lower than previous observations. Furthermore, a change in orientation of the spacecraft during the proton-belt transit resulted in a reduction of radiation dose rates of around 50%. These measurements validate the Orion for future crewed exploration and inform future human spaceflight mission design.

79 ASTRONOMY AND ASTROPHYSICS↗

Using personal monitoring data to derive organ doses for medical radiation workers in the Million Person Study—considerations regarding NCRP Commentary no. 30

The study of low dose and low-dose rate exposure is of central importance in understanding the possible range of health effects from prolonged exposures to radiation. The One Million Person Study of Radiation Workers and Veterans (MPS) of low-dose health effects was designed to evaluate radiation risks among healthy American workers and veterans. The MPS is evaluating low-dose and dose-rate effects, intakes of radioactive elements, cancer and non-cancer outcomes, as well as differences in risks between women and men. Medical radiation workers make up a large group of individuals occupationally exposed to low doses of radiation from external x-ray/gamma exposures. For the MPS, about 100 000 United States medical radiation workers have been selected for study. The approach to the complex dosimetry circumstances for such workers over three to four decades of occupation were initially and broadly described in National Council on Radiation Protection and Measurements (NCRP) Report No. 178. NCRP Commentary No. 30 provides more detail and describes an optimum approach for using personal monitoring data to estimate lung and other organ doses applicable to the cohort and provides specific precautions/considerations applicable to the dosimetry of medical radiation worker organ doses for use in epidemiologic studies. The use of protective aprons creates dosimetric complexity. It is recommended that dose values from dosimeters worn over a protective apron be reduced by a factor of 20 for estimating mean organ doses to tissues located in the torso and that 15% of the marrow should be assumed to remain unshielded for exposure scenarios when aprons are worn. Conversion coefficients relating personal dose equivalent, H p (10) in mSv, to mean absorbed doses to organs and tissues, D T in mGy, for females and males for six exposure scenarios have been determined and presented for use in the MPS. This Memorandum summarises several key points in NCRP Commentary No. 30.

Environmental Sciences & Ecology↗

FLASH-therapy suitable single-pulse proton generation using TiH 2 under nanosecond laser irradiation

We investigated proton emission from titanium hydride (TiH 2 ) targets irradiated in vacuum by a 6-ns, 1064-nm Nd:YAG laser. Time-of-flight measurements with a Faraday cup and an electrostatic ion analyzer resolved distinct proton peaks at high pulse energies, with yields on the order of 10 9 protons per shot. Systematic scans over pulse energy and up to 1000 repeated shots showed that, while the peak amplitude gradually decreased, the integrated proton number remained nearly constant. This behavior is consistent with surface-induced broadening of the plasma expansion while bulk hydrogen is replenished by diffusion and repeated ablation of fresh TiH 2 layers. Using the measured proton numbers and pulse widths, a simple direct-plasma-injection-style scaling indicates peak currents of ∼100 mA and sub-microsecond pulse durations. The pulse structure and yield satisfy key ultra-high-dose-rate criteria and, together with sustained output over 1000 shots, support TiH 2 -based laser ion sources as practical candidates for FLASH-therapy (ultra-high-dose-rate)-oriented studies and injector development using direct plasma injection.

43 PARTICLE ACCELERATORS↗

Comparison of Ion and Neutron Irradiations to 3 dpa at 500C in Ferritic-Martensitic Alloys

The growing global demand for energy will increasingly call upon advanced nuclear fission reactors to supply safe and reliable electricity. The structural and fuel cladding components of these reactors will be subject to extreme conditions of irradiation damage up to several hundred displacements per atom (dpa) at temperatures as high as 700°C. Ferritic-martensitic (F-M) steels are leading candidates for these challenging conditions due to their strength and dimensional stability under irradiation. In order to accelerate the process for evaluating F-M alloys, charged particles are increasingly being used to emulate neutron irradiations. Charged particle irradiations allow the possibility of conducting irradiation experiments within a shorter time period (i.e. at a rate up to 4 orders of magnitude faster) and with minimal radioactivation of the material, enabling lower cost and faster turnaround of post irradiation examination and analysis. However, the irradiation dose rate, damage cascade morphologies, and irradiation damage depth profiles all differ widely between protons, heavier ions, and neutrons. Currently, there is limited understanding of the significance of these physical differences and how they manifest in the irradiated microstructure and mechanical properties of F-M steels. The objective of this study is to evaluate charged particles as a surrogate for neutron irradiations in F-M alloys by assessing common irradiation conditions using Fe++ ions, protons, and neutrons. Keeping the temperature and dose consistent enables isolation of the effects of each irradiating particle and their respective dose rates and cascade morphologies.

Swenson, M.J.↗