Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Threshold”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

MO-G-17A-08: Applications of Quantitative PET/CT Imaging of Yttrium-90: A Tool for Improving Radioembolization

Purpose: Yttrium-90 (Y90) PET/CT post-treatment imaging of radioembolization has fostered significant interest from both the interventional radiology and nuclear medicine communities over the past few years. Recent literature has demonstrated high quantitative accuracy of Y90 PET at the activity concentrations common in radioembolization. However, few have explored methods in which this information can be clinically applied toward improving patient care. Methods: IRB approval and informed consent was obtained for over 35 Y90 post-treatment imaging studies, performed under 2 distinct protocols. In protocol 1, Y90 PET/CT provided quantitative post-treatment imaging, which was then converted into 3D maps of absorbed-dose. Both images and absorbed dose maps were used to manage patient care. In protocol 2, tumor absorbed-dose measurements from Y90 PET/CT were compared to known tumoricidal thresholds. If insufficient absorbed dose was delivered to the tumor, the patient would have an additional Y90 infusion the same day, providing truly patient-specific Y90 PET/CT based treatment-planning. Results: Y90 PET/CT allowed for a superior post-radioembolization evaluation of technical success compared with conventional Y90 bremsstrahlung SPECT. Due to the exceptional resolution of PET, a direct comparison between the distribution of radioembolization and pre-treatment planning intentions can be made. Further, quantification of tumor absorbed-dose directly from PET/CT imaging allows for the prediction of treatment efficacy based on a comparison with known tumoricidal thresholds. This immediate evaluation allowed treating physicians to consider additional or alternate therapies before discovering clinical failure weeks later. One protocol 2 patient was found to have a subtumoricidal absorbed dose following radioembolization. This patient received a same-day infusion of additional Y90 with identical catheter placement to the first infusion. A robust treatment response was seen on follow-up imaging. Conclusion: Y90 PET/CT produces quantifiable image sets, which can be transformed into 3D maps of absorbed dose. This information can be utilized to improve patient care. SIRTeX Medical, Surefire Medical.

60 APPLIED LIFE SCIENCES↗

Radiation Dose-Volume Effects in the Lung

The three-dimensional dose, volume, and outcome data for lung are reviewed in detail. The rate of symptomatic pneumonitis is related to many dosimetric parameters, and there are no evident threshold 'tolerance dose-volume' levels. There are strong volume and fractionation effects.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Calculation of Dose Deposition in 3D Voxels by Heavy Ions

The biological response to high-LET radiation is very different from low-LET radiation, and can be partly attributed to the energy deposition by the radiation. Several experiments, notably detection of gamma-H2AX foci by immunofluorescence, has revealed important differences in the nature and in the spatial distribution of double-strand breaks (DSB) induced by low- and high-LET radiations. Many calculations, most of which are based on amorphous track models with radial dose, have been combined with chromosome models to calculate the number and distribution of DSB within nuclei and chromosome aberrations. In this work, the Monte-Carlo track structure simulation code RITRACKS have been used to calculate directly the energy deposition in voxels (3D pixels). A cubic volume of 5 micrometers of side was irradiated by 1) 450 (1)H+ ions of 300 MeV (LET is approximately 0.3 keV/micrometer) and 2) by 1 (56)Fe26+ ion of 1 GeV/amu (LET is approximately 150 keV/micrometer). In both cases, the dose deposited in the volume is approximately 1 Gy. All energy deposition events are recorded and dose is calculated in voxels of 20 micrometers of side. The voxels are then visualized in 3D by using a color scale to represent the intensity of the dose in a voxel. This simple approach has revealed several important points which may help understand experimental observations. In both simulations, voxels which receive low dose are the most numerous, and those corresponding to electron track ends received a dose which is in the higher range. The dose voxels are distributed randomly and scattered uniformly within the volume irradiated by low-LET radiation. The distribution of the voxels shows major differences for the (56)Fe26+ ion. The track structure can still be seen, and voxels with much higher dose are found in the region corresponding to the track "core". These high-dose voxels are not found in the low-LET irradiation simulation and may be responsible for DSB that are more difficult to repair. By applying a threshold on the dose visualization, voxels corresponding to electron track ends are evidenced and the spatial distribution of voxels is very similar to the distribution of DSB observed in gamma H2AX experiments, even if no chromosomes have been included in the simulation. Furthermore, this work has shown that a significant dose is deposited in voxels corresponding to electron track ends. Since some delta-rays from iron ion can travel several millimeters, they may also be of radiobiological importance.

Plante, Ianik↗

The Mayak Worker Dosimetry System (MWDS-2013): Internal Dosimetry Results

The distribution of calculated internal doses was determined for 8043 Mayak Production Associate (Mayak PA) workers according to the epidemiological cohorts and groups of raw data used as well as the type of industrial compounds of inhaled aerosols. Statistical characteristics of point estimates of accumulated doses to 17 different tissues and organs and the uncertainty ranges were calculated. Under the MWDS-2013 dosimetry system, the mean accumulated lung dose was 185585 mGy, with a median value of 31 mGy and a maximum of 8980 mGy maximum. The ranges of relative standard uncertainty were: from 40 to 2200% for accumulated lung dose, from 25-90% to 2600-3000% for accumulated dose to different regions of respiratory tract, from 13-18% to 2300-2500% for systemic organs and tissues. The Mayak PA workers accumulated internal plutonium lung dose is shown to be close to lognormal. The accumulated internal plutonium dose to systemic organs was close to a log-triangle. The dependency of uncertainty of accumulated absorbed lung and liver doses on the dose estimates itself is also shown. The accumulated absorbed doses to lung, alveolar-interstitial region, liver, bone surface cells and red bone marrow, calculated both with MWDS-2013 and MWDS-2008 have been compared. In general, the accumulated lung doses increased by a factor of 1.8 in median value, while the accumulated doses to systemic organs decreased by factor of 1.3-1.4 in median value. For the cases with identical initial data, accumulated lung doses increased by a factor of 2.1 in median value, while accumulated doses to systemic organs decreased by 8-13% in median value. For the cases with both identical initial data and all of plutonium activity in urine measurements above the decision threshold, accumulated lung doses increased by a factor of 2.8 in median value, while accumulated doses to systemic organs increased by 6-12% in median value.

dose reconstruction↗

Rectal Dose and Source Strength of the High-Dose-Rate Iridium-192 Both Affect Late Rectal Bleeding After Intracavitary Radiation Therapy for Uterine Cervical Carcinoma

Purpose: The purpose of this study was to reconfirm our previous findings that the rectal dose and source strength both affect late rectal bleeding after high-dose-rate intracavitary brachytherapy (HDR-ICBT), by using a rectal dose calculated in accordance with the definitions of the International Commission on Radiation Units and Measurements Report 38 (ICRU{sub RP}) or of dose-volume histogram (DVH) parameters by the Groupe Europeen de Curietherapie of the European Society for Therapeutic Radiology and Oncology. Methods and Materials: Sixty-two patients who underwent HDR-ICBT and were followed up for 1 year or more were studied. The rectal dose for ICBT was calculated by using the ICRP{sub RP} based on orthogonal radiographs or the DVH parameters based on computed tomography (CT). The total dose was calculated as the biologically equivalent dose expressed in 2-Gy fractions (EQD{sub 2}). The relationship between averaged source strength or the EQD{sub 2} and late rectal bleeding was then analyzed. Results: When patients were divided into four groups according to rectal EQD{sub 2} ({>=} or <median dose) and source strength ({>=} or <2.4 cGy.m{sup 2}.h{sup -1}), the group with both a high EQD{sub 2} and a high source strength showed a significantly greater probability of rectal bleeding for ICRU{sub RP}, D{sub 2cc}, and D{sub 1cc}. The patients with a median rectal dose above the threshold level did not show a greater frequency of rectal bleeding unless the source strength exceeded 2.4 cGy.m{sup 2}.h{sup -1}. Conclusions: Our results obtained with data based on ICRU{sub RP} and CT-based DVH parameters indicate that rectal dose and source strength both affect rectal bleeding after HDR-ICBT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

TH-C-18A-08: A Management Tool for CT Dose Monitoring, Analysis, and Protocol Review

Purpose: To develop a customizable tool for enterprise-wide managing of CT protocols and analyzing radiation dose information of CT exams for a variety of quality control applications Methods: All clinical CT protocols implemented on the 11 CT scanners at our institution were extracted in digital format. The original protocols had been preset by our CT management team. A commercial CT dose tracking software (DoseWatch,GE healthcare,WI) was used to collect exam information (exam date, patient age etc.), scanning parameters, and radiation doses for all CT exams. We developed a Matlab-based program (MathWorks,MA) with graphic user interface which allows to analyze the scanning protocols with the actual dose estimates, and compare the data to national (ACR,AAPM) and internal reference values for CT quality control. Results: The CT protocol review portion of our tool allows the user to look up the scanning and image reconstruction parameters of any protocol on any of the installed CT systems among about 120 protocols per scanner. In the dose analysis tool, dose information of all CT exams (from 05/2013 to 02/2014) was stratified on a protocol level, and within a protocol down to series level, i.e. each individual exposure event. This allows numerical and graphical review of dose information of any combination of scanner models, protocols and series. The key functions of the tool include: statistics of CTDI, DLP and SSDE, dose monitoring using user-set CTDI/DLP/SSDE thresholds, look-up of any CT exam dose data, and CT protocol review. Conclusion: our inhouse CT management tool provides radiologists, technologists and administration a first-hand near real-time enterprise-wide knowledge on CT dose levels of different exam types. Medical physicists use this tool to manage CT protocols, compare and optimize dose levels across different scanner models. It provides technologists feedback on CT scanning operation, and knowledge on important dose baselines and thresholds.

60 APPLIED LIFE SCIENCES↗

A Comparison of Dose-Response Models for the Parotid Gland in a Large Group of Head-and-Neck Cancer Patients

Purpose: The dose-response relationship of the parotid gland has been described most frequently using the Lyman-Kutcher-Burman model. However, various other normal tissue complication probability (NTCP) models exist. We evaluated in a large group of patients the value of six NTCP models that describe the parotid gland dose response 1 year after radiotherapy. Methods and Materials: A total of 347 patients with head-and-neck tumors were included in this prospective parotid gland dose-response study. The patients were treated with either conventional radiotherapy or intensity-modulated radiotherapy. Dose-volume histograms for the parotid glands were derived from three-dimensional dose calculations using computed tomography scans. Stimulated salivary flow rates were measured before and 1 year after radiotherapy. A threshold of 25% of the pretreatment flow rate was used to define a complication. The evaluated models included the Lyman-Kutcher-Burman model, the mean dose model, the relative seriality model, the critical volume model, the parallel functional subunit model, and the dose-threshold model. The goodness of fit (GOF) was determined by the deviance and a Monte Carlo hypothesis test. Ranking of the models was based on Akaike's information criterion (AIC). Results: None of the models was rejected based on the evaluation of the GOF. The mean dose model was ranked as the best model based on the AIC. The TD{sub 50} in these models was approximately 39 Gy. Conclusions: The mean dose model was preferred for describing the dose-response relationship of the parotid gland.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-16A-03: A Radiation Pneumonitis Dose-Response Model Incorporating Non- Local Radiation-Induced Bystander Effect

Purpose: Dose-response models that can reliably predict radiation pneumonitis (RP) to guide radiation therapy (RT) for lung cancer presently do not exist. A model is proposed that incorporates non-local radiationinduced bystander effect (RIBE). Methods: A single sigmoid response function, derived from published data for whole lung irradiation, relates RP probability to cumulative lung damage, regardless of fractionation scheme. Lung damage is assumed to be caused by direct local radiation damage, quantified via the linear-quadratic (LQ) model, and RIBE. Based on published data, RIBE is assumed to be activated when per-fraction dose rises above ∼0.6 Gy, but is constant with dose above that threshold. Integral RIBE damage is assumed proportional to lung volume irradiated above ∼0.6 Gy per fraction. Key model parameters include LQ α and β, and two RIBE parameters: the single-fraction probability δ of damage, and a proportionality parameter κ that relates the potential for RIBE damage to irradiated lung volume. All parameters are tentatively fitted from published data, the RIBE parameters from published RP rates for conventionally fractionated RT (CFRT) and stereotactic body RT (SBRT). Results: The model predicts dose-response curves that are consistent with clinical experience. It provides a tentative explanation for why V20 (33 fractions), V13 (20 fractions) and V5 (<10 fractions) are observed to be correlated with RP. It also provides a plausible explanation for the success of SBRT — RIBE damage increases with the number of fractions, so penalizes CFRT relative to SBRT. Conclusion: The proposed model is relatively simple, extrapolates from published data, plausibly explains several clinical observations, and produces dose-response curves that are consistent with clinical experience. While capable of elaboration, its ability to explain doseresponse experience with different fractionation schemes using a small number of assumptions and parameters is an advantage.

60 APPLIED LIFE SCIENCES↗

Optimizing the accuracy of a helical diode array dosimeter: A comprehensive calibration methodology coupled with a novel virtual inclinometer

Purpose: The goal of any dosimeter is to be as accurate as possible when measuring absolute dose to compare with calculated dose. This limits the uncertainties associated with the dosimeter itself and allows the task of dose QA to focus on detecting errors in the treatment planning (TPS) and/or delivery systems. This work introduces enhancements to the measurement accuracy of a 3D dosimeter comprised of a helical plane of diodes in a volumetric phantom. Methods: We describe the methods and derivations of new corrections that account for repetition rate dependence, intrinsic relative sensitivity per diode, field size dependence based on the dynamic field size determination, and positional correction. Required and described is an accurate ''virtual inclinometer'' algorithm. The system allows for calibrating the array directly against an ion chamber signal collected with high angular resolution. These enhancements are quantitatively validated using several strategies including ion chamber measurements taken using a ''blank'' plastic shell mimicking the actual phantom, and comparison to high resolution dose calculations for a variety of fields: static, simple arcs, and VMAT. A number of sophisticated treatment planning algorithms were benchmarked against ion chamber measurements for their ability to handle a large air cavity in the phantom. Results: Each calibration correction is quantified and presented vs its independent variable(s). The virtual inclinometer is validated by direct comparison to the gantry angle vs time data from machine log files. The effects of the calibration are quantified and improvements are seen in the dose agreement with the ion chamber reference measurements and with the TPS calculations. These improved agreements are a result of removing prior limitations and assumptions in the calibration methodology. Average gamma analysis passing rates for VMAT plans based on the AAPM TG-119 report are 98.4 and 93.3% for the 3%/3 mm and 2%/2 mm dose-error/distance to agreement threshold criteria, respectively, with the global dose-error normalization. With the local dose-error normalization, the average passing rates are reduced to 94.6 and 85.7% for the 3%/3 mm and 2%/2 mm criteria, respectively. Some algorithms in the convolution/superposition family are not sufficiently accurate in predicting the exit dose in the presence of a 15 cm diameter air cavity. Conclusions: Introduction of the improved calibration methodology, enabled by a robust virtual inclinometer algorithm, improves the accuracy of the dosimeter's absolute dose measurements. With our treatment planning and delivery chain, gamma analysis passing rates for the VMAT plans based on the AAPM TG-119 report are expected to be above 91% and average at about 95% level for {gamma}(3%/3 mm) with the local dose-error normalization. This stringent comparison methodology is more indicative of the true VMAT system commissioning accuracy compared to the often quoted dose-error normalization to a single high value.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-F-J-157: Effect of Contouring Uncertainty in Post Implant Dosimetry of Low-Dose-Rate Prostate Permanent Seed Brachytherapy

Purpose: There is strong evidence relating post-implant dosimetry for low-dose-rate (LDR) prostate seed brachytherapy to local control rates. The delineation of the prostate on CT images, however, represents a challenge due to the lack of soft tissue contrast in order to identify the prostate borders. This study aims at quantifying the sensitivity of clinically relevant dosimetric parameters to uncertainty in the contouring of prostate. Methods: CT images, post-op plans and contours of a cohort of patients (n=43) (low risk=55.8%, intermediate risk=39.5%, high risk=4.7%), who had received prostate seed brachytherapy, were imported into MIM Symphony treatment planning system. The prostate contours in post-implant CT images were expanded/contracted uniformly for margins of ±1.00 mm, ±2.00 mm, ±3.00 mm, ±4.00 mm and ±5.00 mm. The values for V100 and D90 were extracted from Dose Volume Histograms for each contour and compared. Results: Significant changes were observed in the values of D90 and V100 as well as the number of suboptimal plans for expansion or contraction margins of only few millimeters. Evaluation of coverage based on D90 was found to be less sensitive to expansion errors compared to V100. D90 led to a lower number of implants incorrectly identified with insufficient coverage for expanded contours which increases the accuracy of post-implant QA using CT images compared to V100. Conclusion: In order to establish a successful post implant QA for LDR prostate seed brachytherapy, it is necessary to identify the low and high thresholds of important dose metrics of the target volume such as D90 and V100. Since these parameters are sensitive to target volume definition, accurate identification of prostate borders would help to improve accuracy and predictive value of the post-implant QA process. In this respect, use of imaging modalities such as MRI where prostate is well delineated should prove useful.

60 APPLIED LIFE SCIENCES↗

TCAD-Machine Learning Enabled TID Compact Model Development for Commercial SiC MOSFET

We propose a TCAD (Technology Computer Aided Design)-machine learning coupled approach that combines a TCAD tool (Charon), optimization/uncertainty quantification tool (Dakota), surrogate models, and Bayesian learning capabilities. The coupling approach is used for accurate modeling and calibration of total ionizing dose (TID) induced threshold voltage (V th ) shifts in Commercial-Off-The-Shelf (COTS) semiconductor devices and to develop physics-informed TID compact models. This versatile approach is applied to model the TID effect in an exemplar COTS 3.3 kV SiC power MOSFET (Metal-Oxide-Semiconductor Field-Effect Transistor). With the Charon-Dakota coupling, we can determine key device geometry and doping values based on device physics, which are difficult to obtain or not available for COTS devices but important for TCAD simulation; additionally, we can efficiently generate thousands of simulation results in a large parameter space, which makes it possible to develop data-driven surrogate models and perform Bayesian calibration. Utilizing the full tool-coupling approach, we achieve calibrated TCAD simulation models that accurately capture the average TID-induced V th shifts behavior with total doses and V th shifts saturation at high doses as observed in experimental data. More importantly, the calibrated TCAD simulations are obtained with determined TID model parameters (e.g., hole trap density and capture cross section) values that contain well quantified uncertainties. Furthermore, we can isolate and quantify the noises that are not captured by the TCAD models but exist in the measured data due to measurements and devices variabilities. Lastly, the calibrated surrogate models are used to develop physics-informed TID compact models. The method is generalizable to other devices and/or radiation conditions with few modifications and can provide well-determined uncertainties.

COTS↗

Pure LiF nanophosphors for high exposures of gamma-rays

Nanocrystalline lithium fluoride (LiF) phosphors have been prepared by the chemical co-precipitation method at different pH values (7.0, 8.0, 9.0 and 10.00). The formation of nanocrystalline structure has been confirmed by X-ray diffraction and transmission electron microscope. Thermoluminescence (TL) properties of LiF phosphors irradiated with gamma rays at different doses of 10 Gy - 70 kGy have been further studied. The analysis of TL glow curve revealed the existence of three well resolved glow peaks, first low temperature peak at around 82 deg. C, second at 125 deg. C and third one at higher temperature around 303 deg. C. The LiF nano-crystallites synthesized at 8.00 pH with maximum TL sensitivity at studied gamma doses ranging from threshold to high exposures are potential candidate for dosimetry applications.

36 MATERIALS SCIENCE↗

Annual LDRD Report (FY2019)

The performance of Nuclear Deterrence (ND) systems could be improved by adopting advanced commercial CMOS technologies. However, the radiation hardness of these ND systems must be assured. This project quantified dose rate upset thresholds, allowing us to evaluate whether advanced commercial technologies can be used in rad hard applications. This project also evaluated the susceptibility of advanced commercial technologies to neutron displacement damage and single event effects, and developed hardness assurance methods. As a result of this work, Sandia is now collaborating more closely with DoD agencies and their contractors to understand and improve the radiation hardness of advanced commercial technologies. Sandia Capabilities (SPHINX, lon Beam Lab, FPGA test capabilities) were developed and are being utilized by other programs. Staff were trained to do radiation survivability testing and developed proposals that were funded. Internal and external collaborations and partnerships were developed, including with Georgia Tech. This project received the Best Paper award at the 2019 Hardened Electronics And Radiation Technology (HEART) Conference.

36 MATERIALS SCIENCE↗

Vehicle Radiation Monitoring Systems for Medical Waste Disposal - 12102

Hospitals often declare their waste as being 'non-radioactive'; however this material often has excessive levels of radiation caused either by an accident or lack of control. To ensure the best possible protection against the accidental receipt of radioactive materials and as a safety precaution for their employees, waste-handling companies have installed large-scale radiation portal monitors at their weigh scales or entry gates of the incinerator plant, waste transfer station, and/or landfill. Large-volume plastic scintillator-based systems can be used to monitor radiation levels at entry points to companies handling medical waste. The recent and intensive field tests together with the thousands of accumulated hours of actual real-life vehicle scanning have proven that the plastic scintillation based system is an appropriate radiation control instrument for waste management companies. The Real-Time background compensation algorithm is flexible with automatic adjustable coefficients that will response to rapidly changing environmental and weather conditions maintaining the preset alarm threshold levels. The Dose Rate correction algorithms further enhance the system's ability to meet the stringent requirements of the waste industries need for Dose Rate measurements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Radiation-Induced Skin Injuries to Patients: What the Interventional Radiologist Needs to Know

For a long time, radiation-induced skin injuries were only encountered in patients undergoing radiation therapy. In diagnostic radiology, radiation exposures of patients causing skin injuries were extremely rare. The introduction of fast multislice CT scanners and fluoroscopically guided interventions (FGI) changed the situation. Both methods carry the risk of excessive high doses to the skin of patients resulting in skin injuries. In the early nineties, several reports of epilation and skin injuries following CT brain perfusion studies were published. During the same time, several papers reported skin injuries following FGI, especially after percutaneous coronary interventions and neuroembolisations. Thus, CT and FGI are of major concern regarding radiation safety since both methods can apply doses to patients exceeding 5 Gy (National Council on Radiation Protection and Measurements threshold for substantial radiation dose level). This paper reviews the problem of skin injuries observed after FGI. Also, some practical advices are given how to effectively avoid skin injuries. In addition, guidelines are discussed how to deal with patients who were exposed to a potentially dangerous radiation skin dose during medically justified interventional procedures.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reducing Xerostomia After Chemo-IMRT for Head-and-Neck Cancer: Beyond Sparing the Parotid Glands

Purpose: To assess whether, in addition to sparing the parotid glands (PGs), xerostomia after chemotherapy plus intensity-modulated radiotherapy (chemo-IMRT) for head-and-neck cancer is affected by reducing the dose to the other salivary glands. Patients and Methods: In a prospective study, 78 patients with Stage III-IV oropharynx/nasopharynx cancer underwent chemo-IMRT, with the aim of sparing the parts of the bilateral PGs, oral cavity (OC) containing the minor salivary glands, and contralateral submandibular gland (SMG) outside the target (when contralateral level I was not a target). Before therapy and periodically for 24 months, validated patient-reported xerostomia questionnaire (XQ) scores and observer-graded xerostomia scores were recorded. Also, the stimulated and unstimulated saliva was measured selectively from each of the PGs and SMGs. The mean OC doses served as surrogates of minor salivary gland dysfunction. Regression models assessed the XQ and observer-graded xerostomia predictors. Results: Statistically significant predictors of the XQ score on univariate analysis included the OC, PG, and SMG mean doses and the baseline XQ score, time since RT, and both stimulated and unstimulated PG saliva flow rates. Similar factors were statistically significant predictors of observer-graded xerostomia. The OC, PG, and SMG mean doses were moderately intercorrelated (r = 0.47-0.55). On multivariate analyses, after adjusting for the PG and SMG doses, the OC mean dose (p < .0001), interval from RT (p < .0001), and stimulated PG saliva (p < .0025) were significant predictors of the XQ scores and the OC mean dose and time for observer-graded xerostomia. Although scatter plots showed no thresholds, an OC mean dose of <40 Gy and contralateral SMG mean dose of <50 Gy were each associated with low patient-reported and observer-rated xerostomia at almost all post-therapy points. Conclusion: The PG, SMG, and OC mean doses were significant predictors of both patient-reported and observer-rated xerostomia after chemo-IMRT, with OC doses remaining significant after adjusting for the PG and SMG doses. These results support efforts to spare all the salivary glands by IMRT, beyond the PGs alone.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Risk of Radiation Retinopathy in Patients With Orbital and Ocular Lymphoma

Purpose: Radiation retinopathy is a potential long-term complication of radiation therapy to the orbit. The risk of developing this adverse effect is dose dependent; however, the threshold is unclear. The aim of this study was to identify the risk of developing radiation retinopathy at increasing radiation doses. Methods and Materials: A 40-year retrospective review was performed of patients who received external beam radiation therapy for ocular/orbital non-Hodgkin lymphoma (NHL). Results: Sixty-seven patients who had at least one ophthalmic follow-up examination were included in this study. Most patients (52%) were diagnosed with NHL involving the orbit. Patients received external beam radiation therapy at doses between 1886 and 5400 cGy (mean, 3033 {+-} 782 cGy). Radiation retinopathy developed in 12% of patients, and the median time to diagnosis was 27 months (range, 15-241months). The mean prescribed radiation dose in patients with retinopathy was 3309 {+-} 585 cGy, and the estimated retinal dose (derived by reviewing the dosimetry) was 3087 {+-} 1030 cGy. The incidence of retinopathy increased with dose. The average prescribed daily fractionated dose was higher in patients who developed retinopathy than in patients who did not (mean, 202 cGy vs 180 cGy, respectively; P = .04). More patients with radiation retinopathy had comorbid diabetes mellitus type 2 than patients without retinopathy (P = .015). In our study, the mean visual acuity of the eyes that received radiation was worse than that of the eyes that did not (P = .027). Other postradiotherapy ocular findings included keratitis (6%), dry eyes (39%), and cataract (33%). Conclusions: Radiation retinopathy, a known complication of radiotherapy for orbital tumors, relates to vascular comorbidities and dose. Higher total doses and larger daily fractions (>180 cGy) appear to be related to higher rates of retinopathy. Future larger studies are required to identify a statistically significant threshold for the development of retinopathy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗