Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dose Assessment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Impact of phenanthrene co-administration on the toxicokinetics of benzo[a]pyrene in humans. UPLC-accelerator mass spectrometry following oral microdosing

Current risk assessments for environmental carcinogens rely on animal studies utilizing doses orders of magnitude higher than actual human exposures. Epidemiological studies of people with high exposures (e.g., occupational) are of value, but rely on uncertain exposure data. In addition, exposures are typically not to a single chemical but to mixtures, such as polycyclic aromatic hydrocarbons (PAHs). The extremely high sensitivity of accelerator mass spectrometry (AMS) allows for dosing humans with known carcinogens with de minimus risk. In this study UPLC-AMS was used to assess the toxicokinetics of [ 14 C]-benzo[a]pyrene ([ 14 C]-BaP) when dosed alone or in a binary mixture with phenanthrene (Phe). Plasma was collected for 48 h following a dose of [ 14 C]-BaP (50 ng, 5.4 nCi) or the same dose of [ 14 C]-BaP plus Phe (1250 ng). Following the binary mixture, C max of [ 14 C]-BaP significantly decreased (4.4-fold) whereas the volume of distribution (V d ) increased (2-fold). Further, the toxicokinetics of twelve [ 14 C]-BaP metabolites provided evidence of little change in the metabolite profile of [ 14 C]-BaP and the pattern was overall reduction consistent with reduced absorption (decrease in C max ). Although Phe was shown to be a competitive inhibitor of the major hepatic cytochrome P-450 (CYP) responsible for metabolism of [ 14 C]-BaP, CYP1A2, the high inhibition constant (K i ) and lack of any increase in unmetabolized [ 14 C]-BaP in plasma makes this mechanism unlikely to be responsible. Rather, co-administration of Phe reduces the absorption of [ 14 C]-BaP through a mechanism yet to be determined. Furthermore, this is the first study to provide evidence that, at actual environmental levels of exposure, the toxicokinetics of [ 14 C]-BaP in humans is markedly altered by the presence of a second PAH, Phe, a common component of environmental PAH mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Air Pathway Dose Modeling for the E-Area Low-Level Waste Facility

The US Department of Energy (DOE) Order 435.1 performance assessment (PA) process (USDOE 1999) prescribes a performance objective (10 mrem y -1 ) for evaluating atmospheric releases of radionuclides from DOE low-level waste (LLW) disposal facilities. The potential dose to an individual from exposure to radionuclides released into the atmosphere from LLW disposals can be estimated by application of radionuclide -specific dose-release factors (DRFs) (mrem Ci -1 ) to estimated flux rates (Ci y -1 ) at a particular time and location. In Revision 0 of this report, Lee (2006) calculated DRFs for potential atmospheric releases of 15 volatile radionuclides from seven ELLWF disposal units in support of the 2008 ELLWF PA (WSRC 2008). The mainframe version of the US Environmental Protection Agency’s (EPA) dose model CAP88 was used in the Revision 0 assessment. In Revision 1 of this report (Dixon and Minter 2017), the site-specific Savannah River National Laboratory (SRNL) atmospheric dose models MAXDOSE-SR version 2013 (Stone and Jannik 2013a) and MAXINE version 2017 (Bell 2017) were used to calculate DRFs for ten radionuclides. This work (Revision 2) supersedes Revision 0 (Lee 2006) and Revision 1 (Dixon and Minter 2017) of this report. The Revision 2 method for estimating new DRFs for the ELLWF disposal units is described in this report.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Air Pathway Dose Modeling for the E-Area Low-Level Waste Facility

The US Department of Energy (DOE) Order 435.1 performance assessment (PA) process (USDOE 1999) prescribes a performance objective (10 mrem y -1 ) for evaluating atmospheric releases of radionuclides from DOE low-level waste (LLW) disposal facilities. The potential dose to an individual from exposure to radionuclides released into the atmosphere from LLW disposals can be estimated by application of radionuclide-specific dose-release factors (DRFs) (mrem Ci -1 ) to estimated flux rates (Ci y -1 ) at a particular time and location. In Revision 0 of this report, Lee (2006) calculated DRFs for potential atmospheric releases of 15 volatile radionuclides from seven ELLWF disposal units in support of the 2008 ELLWF PA (WSRC 2008). The mainframe version of the US Environmental Protection Agency’s (EPA) dose model CAP88 was used in the Revision 0 assessment. In Revision 1 of this report (Dixon and Minter 2017), the site-specific Savannah River National Laboratory (SRNL) atmospheric dose models MAXDOSE-SR version 2013 (Stone and Jannik 2013a) and MAXINE version 2017 (Bell 2017) were used to calculate DRFs for ten radionuclides. Revision 2 provided updated DRFs using the current version of the US Environmental Protection Agency’s (EPA) dose model CAP88-PC Version 4.1. After Revision 2 was finalized, DRFs were requested for Ar-37, Ar-39, Kr-83m, and Hg-206. Revision 3 provides the additional DRFs calculated using the same methods as used in Revision 2 of this document. The method for estimating new DRFs for the ELLWF disposal units is described in this report.

61 RADIATION PROTECTION AND DOSIMETRY↗

Radiation-Induced Myocardial Fibrosis in Long-Term Esophageal Cancer Survivors

Radiation-induced cardiac toxicity is a potential lethal complication. The aim of this study was to assess whether there is a dose-dependent relationship between radiation dose and myocardial fibrosis in patients who received neoadjuvant chemoradiation (nCRT) for esophageal cancer (EC).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Reassessment of Dose Contributions from the Paducah Cask Special Waste Form Buried in the E-Area Low-Level Waste Facility

During a recent revision to the groundwater and inadvertent human intruder screening analysis report (Aleman and Hamm, 2023), weaknesses within the screening logic were observed resulting in the addition of U-235 being brought back into the list of radionuclides requiring inventory limits within the Paducah Cask special waste form (SWF). In addition, while reviewing the earlier vadose zone transport analysis efforts, an inconsistency was observed in the initial U-235P inventory that was supplied to the Consolidated Waste Tracking System (CWTS) back in 2009.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reassessment of Dose Contributions from the M-Area Glass Special Waste Form Buried in the E-Area Low-Level Waste Facility

During a recent revision to the groundwater (GW) and inadvertent human intruder (IHI) screening analysis report (Aleman and Hamm, 2023), weaknesses within the screening logic were observed resulting in U-235 being brought back into the list of radionuclides requiring inventory limits within the M-Area Glass SWF. In addition, while reviewing the earlier vadose zone (VZ) transport analysis efforts, an input deck error was observed in the U-234G VZ transport simulation.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Reevaluation of Radiation-Protection Standards for Workers and the Public Based on Current Scientific Evidence

President Trump’s recent executive orders to “Usher in a Nuclear Renaissance,” coupled with the global pledge to triple nuclear energy capacity by 2050, underscore nuclear energy’s importance to national security and economic prosperity. This renewed interest has prompted efforts to spur nuclear-energy deployment, including assessing factors impeding it. One issue that has previously been identified as adding to the cost of nuclear energy is excessively conservative requirements, including those related to radiation protection. This technical review, therefore, examines current radiation-protection standards that were established decades ago when more limited data were available and nuclear-energy expansion was not a national priority. The review focuses on scientific evidence regarding the health effects of ionizing radiation at annual doses of 10,000 mrem or less. The review evaluates epidemiological studies, radiobiological research, and positions of relevant professional organizations to assess whether such doses result in discernable or observable increases in negative health outcomes. The review also surveys the literature related to economic and practical implications of current radiation-protection standards and practices. Based on this assessment, we propose maintaining an annual occupational whole-body dose limit of 5,000 mrem/yr and eliminating all “as low as reasonably achievable” requirements and limits below this threshold. This change could potentially reduce radiation-protection costs by millions of dollars annually for each reactor, as well as decrease the overall costs and correct misconceptions about the risks associated with all nuclear technologies. The evidence further supports future consideration of a 10,000 mrem/yr limit that would maintain appropriate safety margins while further reducing protection costs. Similarly, given the data and that the average annual radiation dose per person in the U.S. is 620 mrem, we believe the public dose limits of 100 mrem/yr are unnecessarily restrictive; increasing to 500 mrem/yr would maintain substantial safety margins—a factor of 10 below the occupational limit—while reducing regulatory burdens and associated bureaucracy. While we acknowledge ongoing scientific debate and encourage continued research on the health effects of ionizing radiation, our review indicates current frameworks are overly conservative. These overly stringent limits not only impose unnecessary economic burdens without corresponding health benefits but also divert safety focus and resources from more important considerations. Although this study was motivated by nuclear-power considerations, reforms to radiation-protection requirements have significant positive implications for other areas, such as nuclear medical applications, environmental remediation, nuclear-waste management and disposal, and industrial applications of nuclear technologies.

61 RADIATION PROTECTION AND DOSIMETRY↗

Improving Medication Regimen Recommendation for Parkinson’s Disease Using Sensor Technology

Parkinson’s disease medication treatment planning is generally based on subjective data obtained through clinical, physician-patient interactions. The Personal KinetiGraph™ (PKG) and similar wearable sensors have shown promise in enabling objective, continuous remote health monitoring for Parkinson’s patients. In this proof-of-concept study, we propose to use objective sensor data from the PKG and apply machine learning to cluster patients based on levodopa regimens and response. The resulting clusters are then used to enhance treatment planning by providing improved initial treatment estimates to supplement a physician’s initial assessment. We apply k-means clustering to a dataset of within-subject Parkinson’s medication changes—clinically assessed by the MDS-Unified Parkinson’s Disease Rating Scale-III (MDS-UPDRS-III) and the PKG sensor for movement staging. A random forest classification model was then used to predict patients’ cluster allocation based on their respective demographic information, MDS-UPDRS-III scores, and PKG time-series data. Clinically relevant clusters were partitioned by levodopa dose, medication administration frequency, and total levodopa equivalent daily dose—with the PKG providing similar symptomatic assessments to physician MDS-UPDRS-III scores. A random forest classifier trained on demographic information, MDS-UPDRS-III scores, and PKG time-series data was able to accurately classify subjects of the two most demographically similar clusters with an accuracy of 86.9%, an F1 score of 90.7%, and an AUC of 0.871. A model that relied solely on demographic information and PKG time-series data provided the next best performance with an accuracy of 83.8%, an F1 score of 88.5%, and an AUC of 0.831, hence further enabling fully remote assessments. These computational methods demonstrate the feasibility of using sensor-based data to cluster patients based on their medication responses with further potential to assist with medication recommendations.

59 BASIC BIOLOGICAL SCIENCES↗

Radiological Consequence Evaluation for Dragonfly Mission

The scoping calculations presented in this report were developed to provide a conservative estimate of radiological dose consequences associated with launch accidents involving one multi-mission radioisotope thermoelectric generator (MMRTG) and possibly up to 43 light-weight radioisotope heater units (LWRHUs) for the upcoming National Aeronautics and Space Administration (NASA) Dragonfly mission. This report summarizes dose consequence analysis from SAND2019-11148, “Nuclear Risk Assessment 2019 Update for the Mars 2020 Mission Environmental Impact Statement,” referred to in this document as the Mars 2020 nuclear risk analysis (NRA) and compares those results to a parametric analysis used to analyze potential dose consequences for the Dragonfly mission.

07 ISOTOPE AND RADIATION SOURCES↗

A neutron fluence map of the Los Alamos National Laboratory Godiva IV critical assembly

A neutron fluence map and a total ionizing dose map of the Los Alamos National Laboratory Godiva IV fast burst critical assembly was generated using passive reactor dosimetry, comprised of sulfur pellets and thermoluminescent dosimeters. Godiva IV is an unmoderated, fast burst, critical assembly constructed of approximately 65 kg of highly enriched uranium fuel alloyed with 1.5 % molybdenum for strength. The mapping was performed during a single 75.6 ºC temperature rise burst operation, with the top and sides of the cylindrical Godiva-IV Top Hat covered in passive dosimetry. Dosimetry was placed in a symmetric pattern around the Top Hat, with higher concentrations near the control rods and burst rod. A specific portion of the lower quadrant of the burst rod was mapped to confirm a testing region where the neutron fluence varied by no more than ± 5%. The results will be used to assess the neutron, gamma, and total ionizing dose environment in three-dimensional space around the assembly for higher fidelity experiment placement, active dosimetry positioning, and radiation field characterization.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The Potential for Midtreatment Albumin-Bilirubin (ALBI) Score to Individualize Liver Stereotactic Body Radiation Therapy

Our individualized functional response adaptive approach to liver stereotactic body radiation therapy (SBRT) with assessment of indocyanine green (ICG) retention at baseline and midtreatment to detect subclinical changes in liver function, permitting dose adjustment, has decreased toxicity while preserving efficacy. We hypothesized that assessment of the albumin-bilirubin (ALBI) score at baseline and midtreatment would allow for more practical identification of patients at risk for treatment-related toxicity (TRT).

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dose conversion factors for absorbed dose in a mobile phone to absorbed dose in critical organs in an anthropomorphic phantom for emergency dosimetry applications: OSL and TL experimental results, and Monte Carlo simulations

Here, an anthropomorphic phantom was equipped with three smartphones and irradiated in five separate exposure geometries in air using a 137 Cs source. The phantom was fitted internally with thermoluminescence dosimeters (TLD-700 chips) to measure the absorbed dose to the individual organs, while the absorbed doses in the phones were evaluated using optically stimulated luminescence (OSL) from the phones’ surface mount resistors (SMRs), along with reference dosimeters, namely Luxel OSL films and TLD-700 chips. The results indicate a strong dependence on the phone location with respect to the source due to shielding and scattering from the body. Dose conversion factors were calculated for several plausible exposure scenarios in order to correlate the absorbed doses measured in the phones to the average body dose received by the phantom. The measured conversion factors were compared with calculated factors using MCNP6.2 Monte Carlo simulations and an ADAM voxel phantom. Experiments were conducted to assess how the phone orientation and angle impacts the dose received by the phone components. The overall results indicate that the doses measured can vary significantly depending upon exposure geometry (including phone position and angle). However, in rotational irradiation symmetry, the phone doses lead to an over-estimate of the average whole-body dose by an average of ~10%, independent of the phone locations tested in this study. This result, if confirmed in future studies, may be acceptable for triage.

61 RADIATION PROTECTION AND DOSIMETRY↗

First multi-institutional systematic comparison of the neutron ambient dose equivalent produced by proton therapy systems

Objective. Isochronous cyclotrons, synchrocyclotrons, and synchrotrons are used to accelerate protons for proton therapy. An accurate measurement of neutron doses generated by these accelerators and associated delivery systems and its clinical relevance requires systematic protocols and proper neutron dosimetry for a meaningful assessment. We present the first comprehensive comparison of neutron ambient dose equivalent (H*(10)) produced by clinically operational proton therapy systems. Approach. Treatment plans with 10 cm modulation-depth and ranges of 10 cm (R10M10) and 25 cm (R25M10) were created to cover a 10 × 10 × 10 cm 3 water target. The pencil beam scanning proton therapy machines studied were: two gantry-mounted synchrocyclotrons (Hyperscan, Mevion, half-gantry), two isochronous cyclotrons (ProBeam, Varian, full-gantry), one isochronous cyclotron (Proteus, IBA, full-gantry), and two synchrotrons (PROBEAT, Hitachi, full- and half-gantry). Proton beams were delivered to 30 × 30 × 40 cm 3 plastic water phantoms. WENDI-II and LUPIN-BF3-NP neutron rem-meters were positioned at three angles (0°, 45°, 90°) relative to the beam direction to measure the neutron H*(10) at distances between 50–300 cm from the isocenter. Main results. H*(10) showed dependence on beam energy, machine type, and measurement location. The highest reading was for the gantry-mounted synchrocyclotron, whereas other systems produced approximately comparable neutron doses. In all cases, the H*(10) reduced with distance from the isocenter. The H*(10) drop at 2 m distance compared to that at 0.5 m was a factor of ∼5 for the gantry-mounted synchrocyclotron whereas in other systems the decrease was a factor of 10. The WENDI-II device suffered from dead-time-associated under-estimation of the dose by a factor of ∼2–3 under the synchrocyclotron beam due to its high dose-per-pulse. However, WENDI-II and LUPIN-BF3-NP results were within reasonable agreement in isochronous cyclotron and synchrotron beams, indicating that both devices are suitable for those systems. Significance. Neutron H*(10) is dependent on various parameters including beam energy, measurement location, as well as machine design. Caution must be exercised in choosing the appropriate neutron-dose-measurement device to be used for low-duty-factor, particularly in high-instantaneous-rate proton delivery systems. By delivering the same volumetric proton dose across different machines, this work provides a benchmark for inter-system comparisons and serves as a foundation for future studies.

LUPIN↗

A physiologically based pharmacokinetic (PBPK) model to align dosimetry of the isobutyl metabolic series in rats and humans

Here, we developed a physiologically based pharmacokinetic (PBPK) model in rats and humans for the isobutyl metabolic series including isobutyl acetate, isobutanol, isobutyraldehyde, and isobutyric acid. Chemical manufactures routinely use these compounds as solvents, for chemical synthesis, as potential biofuels, de-icing fluids, and additives for food and/or fragrance in consumer products. Human exposure to isobutyl compounds can occur through inhalation or oral routes. We previously developed a PBPK model for the propyl metabolic series and utilized it as a framework to create the isobutyl PBPK model due to the chemical similarities between the two series. To support model development, we measured in vitro metabolism of isobutyl acetate in rat and human blood and liver S9 fractions. Compared to rats, humans demonstrated faster isobutyl acetate hydrolysis in liver S9 fractions, while the hydrolysis rates in blood were similar between the two species. We used concentrations of isobutyl compounds measured in air and blood from rats exposed to isobutyl acetate and isobutanol as well as other published data to further parameterize the model. Following exposure to either isobutyl acetate or isobutanol, we observed isobutanol concentrations highest among the isobutyl compounds in the blood of rats. Overall, the model accurately predicts measured time course concentrations of isobutyl acetate, isobutanol, and isobutyric acid in available data in rats and humans. Sensitivity analyses identified alveolar ventilation rates, isobutyl metabolism rates, and cardiac output as the most sensitive parameters affecting concentrations of isobutyl compounds in blood. The isobutyl PBPK model enables comparisons of internal dose metrics across various isobutyl compound exposures and species and allows for calculation of equivalent external exposures that result in the same dose metric. Regulators can employ this PBPK model to predict and align internal dose metrics of isobutyl compounds for risk assessment purposes.

2-methyl-1-propanol↗

Hole in one: Pathways to deterministic single-acceptor incorporation in Si(100)-2 x 1

We report that stochastic incorporation kinetics can be a limiting factor in the scalability of semiconductor fabrication technologies using atomic-precision techniques. While these technologies have recently been extended from donors to acceptors, the extent to which kinetics will impact single-acceptor incorporation has yet to be assessed. To identify the precursor molecule and dosing conditions that are promising for deterministic incorporation, we develop and apply an atomistic model for the single-acceptor incorporation rates of several recently demonstrated molecules: diborane (B 2 H 6 ), boron trichloride (BCl 3 ), and aluminum trichloride in both monomer (AlCl 3 ) and dimer forms (Al 2 Cl 6 ). While all three precursors can realize single-acceptor incorporation, we predict that diborane is unlikely to realize deterministic incorporation, boron trichloride can realize deterministic incorporation with modest heating (50 °C), and aluminum trichloride can realize deterministic incorporation at room temperature. We conclude that both boron and aluminum trichloride are promising precursors for atomic-precision single-acceptor applications, with the potential to enable the reliable production of large arrays of single-atom quantum devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Development and Evaluation of Embrittlement Resistant Alloys for Advanced LWR Cladding

The primary challenge preventing the deployment of reactor designs that leverage wrought FeCrAl as an advanced light-water reactor (LWR) cladding is irradiation hardening and embrittlement. Wrought FeCrAl alloys experience a loss of post-irradiation ductility and fracture toughness under low-temperature neutron irradiation (< 350°C) resulting from the combined effects of dislocation loop formation and the irradiation-enhanced precipitation of Cr-rich alpha-prime precipitates throughout the microstructure. Over the past decade, significant improvements in our understanding regarding the effect of Cr and Al content have been enabled through neutron irradiations, but even optimized wrought alloys such as C26M remain vulnerable to brittle failure during storage, transportation, and handling following irradiation. This report summarizes multiple irradiation campaigns initiated over the past 7 years and provides recent insights into the effect of (1) minor alloying composition, (2) alloy processing strategy, (3) crystal structure, and (4) the use of advanced oxide dispersion strengthened (ODS) alloys. The first irradiation campaign irradiated body-centered cubic FeCrAl alloy C26M with and without elements such as Mo and Y. It also included face-centered cubic alumina-forming austenitic (AFA) alloys that have a steeper neutronic penalty but that have far superior high-temperature strength than wrought FeCrAl. Finally, this campaign compared conventional wrought C26M with the same material produced using modern powder metallurgical hotisostatic pressing (PM-HIP). The second irradiation campaign, initiated in 2018, irradiated wrought and FeCrAl-ODS materials up to 50 dpa to assess their irradiation resistance to high-doses. The results of this work indicate that wrought C26M suffers significant degradation following neutron irradiation at LWR-relevant temperatures regardless of Mo and Y content. The PM-HIP variant appears to be more resilient to irradiation-induced ductility loss in comparison with wrought variants but still loses almost all ductility by 8 dpa. Notably, the AFAs retained at least 5% total elongation after irradiation at the same dose and temperature condition, although additional deterioration may be expected at higher fluence levels. FeCrAl-ODS materials show the greatest promise as a transformative longer-term accident-tolerant fuel (LT-ATF) cladding material. The extruded 106ZY10C alloy retained 10% total elongation after 16 dpa irradiation and retained 8% total elongation after 50 dpa. Additional challenges with FeCrAl-ODS alloys also remain, including optimization of end cap joining methodologies, enhancement of fracture toughness, scaling production to prove economic viability, and optimizing post-pilger heat treatments to maximize ductility and irradiation resistance. This series of irradiations demonstrates the efficacy of the LWR testbed available within the United States for the rapid irradiation and down-selection of LT-ATF candidates. As the country rapidly accelerates its timeline for the deployment of advanced reactor concepts, the effective utilization of the High Flux Isotope Reactor for separate-effects style irradiations should continue to be prioritized to answer the final questions pertaining to LT-ATF candidates necessary for the deployment of advanced boiling water reactors and small modular reactors.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison and multi-model inference of excess risks models for radiation-related solid cancer

In assessments of detrimental health risks from exposures to ionising radiation, many forms of risk to dose–response models are available in the literature. The usual practice is to base risk assessment on one specific model and ignore model uncertainty. The analysis illustrated here considers model uncertainty for the outcome all solid cancer incidence, when modelled as a function of colon organ dose, using the most recent publicly available data from the Life Span Study on atomic bomb survivors of Japan. Seven recent publications reporting all solid cancer risk models currently deemed plausible by the scientific community have been included in a model averaging procedure so that the main conclusions do not depend on just one type of model. The models have been estimated with different baselines and presented for males and females at various attained ages and ages at exposure, to obtain specially computed model-averaged Excess Relative Risks (ERR) and Excess Absolute Risks (EAR). Monte Carlo simulated estimation of uncertainty on excess risks was accounted for by applying realisations including correlations in the risk model parameters. Three models were found to weight the model-averaged risks most strongly depending on the baseline and information criteria used for the weighting. Fitting all excess risk models with the same baseline, one model dominates for both information criteria considered in this study. Based on the analysis presented here, it is generally recommended to take model uncertainty into account in future risk analyses.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Comparison of atmospheric radionuclide dispersion models for a risk-informed consequence-driven advanced reactor licensing framework

Current nuclear facility emergency planning zones (EPZs) are based on outdated distance-based criteria, predating comprehensive dose and risk-informed frameworks. Recent advancements in simulation tools have permitted the development of site-specific, dose, and risk-based consequence-driven assessment frameworks. This study investigated the computation of advanced reactor (AR) EPZs using two atmospheric dispersion models: a straight-line Gaussian plume model (GPM) and a semi-Lagrangian Particle in Cell (PIC). Two case studies were conducted: (1) benchmarking the NRC SOARCA study for the Peach Bottom Nuclear Generating Station and (2) analyzing an advanced INL Heat Pipe Design A microreactor's end-of-cycle inventory. The dose criteria for both cases were 10 mSv at mean weather conditions and 50 mSv at 95th percentile weather conditions at 96 h post-release. Results demonstrated that GPM and PIC estimated similar mean peak dose levels for large boiling water reactors in the farfield case, placing EPZ limits beyond current regulations. For ARs with source terms remaining in the nearfield, PIC modeling without specific nearfield considerations could result in excessively high doses and inaccurate EPZ designations. PIC dispersion demonstrated an order of magnitude higher estimate of nearfield inhalation dose contribution when compared to GPM results. Furthermore, both models significantly reduced EPZ sizing within the nearfield. Thus, reductions in the AR source term may eliminate the need for a separate EPZ.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗