Backgrounds and projected limits from dark matter direct detection experiments
A simple formula is introduced which indicates the amount by which projections of dark matter direct detection experiments are expected to be degraded due to backgrounds.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
A simple formula is introduced which indicates the amount by which projections of dark matter direct detection experiments are expected to be degraded due to backgrounds.
Abstract Silicon Microelectromechanical Systems (MEMS) resonators have broad commercial applications for timing and inertial sensing. However, the performance of MEMS resonators is constrained by dissipation mechanisms, some of which are easily detected and well-understood, but some of which have never been directly observed. In this work, we present measurements of the quality factor, Q , for a family of single crystal silicon Lamé-mode resonators as a function of temperature, from 80–300 K . By comparing these Q measurements on resonators with variations in design, dimensions, and anchors, we have been able to show that gas damping, thermoelastic dissipation, and anchor damping are not significant dissipation mechanisms for these resonators. The measured f · Q product for these devices approaches 2 × 10 13 , which is consistent with the expected range for Akhiezer damping, and the dependence of Q on temperature and geometry is consistent with expectations for Akhiezer damping. These results thus provide the first clear, direct detection of Akhiezer dissipation in a MEMS resonator, which is widely considered to be the ultimate limit to Q in silicon MEMS devices.
Directional elements are relied on to achieve selectivity in fault detection in power systems. Although such elements have been deployed successfully for many years, there is an increased need for novel methods to deal with the unique challenges of directional protection in modern distribution networks. This article analyzes the impact of inverter-based resources (IBRs) on existing directional protection methods in distribution systems. It identifies parts of such elements that pose a risk of misoperation when IBRs are used in distribution networks. The authors have developed a new directional detection method for unbalanced faults in such networks using superimposed symmetrical sequence quantities. The phase angle of the superimposed negative sequence admittance is used to determine fault direction. The paper also presents a real-time co-simulation platform between a simulated distribution system and physical protection relay, using OPAL-RT. An SEL-411L relay is used to program the detection algorithm. This hardware-in-the-loop (HIL) setup is used to verify the performance of the method and the results are compared with existing directional methods
To identify the mode-converted electron Bernstein wave (EBW) in a torus plasma directly, we have developed an interferometry system, in which a diagnostic microwave injected outside of the plasma column was directly detected with the probing antenna inserted into the plasma. In this work, plasma production and heating are achieved with 2.45 GHz, 2.5 kW electron cyclotron heating (ECH), whereas diagnostics are carried out with a lower power (10 W) separate frequency (1-2.1 GHz) microwave. Three components, i.e., two electromagnetic (toroidal and poloidal directions) and an electrostatic (if refractive index is sufficiently higher than unity, it corresponds to radial component), of ECRF electric field are simultaneously measured with three probing antennas, which are inserted into plasma. Selectivities of each component signal were checked experimentally. Excitation antennas have quite high selectivity of direction of linear polarization. As probing antennas for detecting electromagnetic components, we employed a monopole antenna with a length of 35 mm, and the separation of the poloidal (O-wave) and toroidal (X-wave) components of ECRF electric field could be available with this antenna. To detect EBW, which is an electrostatic wave, a small tip (1 mm) antenna was used. As the preliminary results, we detected signals that have three characteristics of EBW, i.e., short wavelength, backward propagation, and electrostatic.
We study a fermionic Dark Matter particle carrying magnetic dipole moment and analyze its impact on direct detection experiments. In particular we show that it can accommodate the DAMA, CoGeNT and CRESST experimental results. Assuming conservative bounds, this candidate is shown not to be ruled out by the CDMS, XENON and PICASSO experiments. We offer an analytic understanding of how the long-range interaction modifies the experimental allowed regions, in the cross section versus Dark Matter mass parameter space, with respect to the typically assumed contact interaction. Finally, in the context of a symmetric Dark Matter sector, we determine the associated thermal relic density, and further provide relevant constraints imposed by indirect searches and colliders.
NASA Goddard Space Flight Center is developing a direct-detection free-space laser communications transceiver test bed. The laser transmitter is a master-oscillator power amplifier (MOPA) configuration using a 1060 nm wavelength laser-diode with a two-stage multi-watt Ytterbium fiber amplifier. Dual Mach-Zehnder electro-optic modulators provide an extinction ratio greater than 40 dB. The MOPA design delivered 10-W average power with low-duty-cycle PPM waveforms and achieved 1.7 kW peak power. We use pulse-position modulation format with a pseudo-noise code header to assist clock recovery and frame boundary identification. We are examining the use of low-density-parity-check (LDPC) codes for forward error correction. Our receiver uses an InGaAsP 1 mm diameter photocathode hybrid photomultiplier tube (HPMT) cooled with a thermo-electric cooler. The HPMT has 25% single-photon detection efficiency at 1064 nm wavelength with a dark count rate of 60,000/s at -22 degrees Celsius and a single-photon impulse response of 0.9 ns. We report on progress toward demonstrating a combined laser communications and ranging field experiment.
Not Available
We present the direct imaging detection of a faint tertiary companion to the single-lined spectroscopic binary HD 8375 AB. Initially noticed as an 53 m s{sup -1} yr{sup -1} Doppler acceleration by Bowler et al., we have obtained high-contrast adaptive optics observations at Keck using NIRC2 that spatially resolve HD 8375 C from its host(s). Astrometric measurements demonstrate that the companion shares a common proper-motion. We detect orbital motion in a clockwise direction. Multiband relative photometry measurements are consistent with an early M-dwarf spectral type ({approx}M1V). Our combined Doppler and imaging observations place a lower-limit of m {>=} 0.297 M{sub Sun} on its dynamical mass. We also provide a refined orbit for the inner pair using recent radial velocity measurements obtained with the High Resolution Echelle Spectrometer. HD 8375 is one of many triple-star systems that are apparently missing in the solar neighborhood.
The Cryogenic Dark Matter Search (CDMS) is carrying out a direct detection search for Weakly Interacting Massive Particles (WIMPs), one of the favored candidates for dark matter. Our latest data has placed some of the most stringent limits on the WIMP-nucleon spin-independent cross section of 6.6x10{sup -44} cm{sup 2} for 60 GeV WIMPs at the 90% confidence level. This paper describes our experiment and our latest results; the status of SuperCDMS Soudan, a new experiment at the Soudan mine in Minnesota that will achieve a sensitivity of 5x10{sup -45} cm{sup 2} our plans for SuperCDMS SNOLAB, a 100 kg experiment with a projected sensitivity of 3x10{sup -46} cm{sup 2}; and GEODM, a ton-scale experiment at DUSEL with a projected sensitivity of 2x10{sup -47} cm{sup 2}.
We propose a new application of single molecule magnet crystals: their use as “magnetic bubble chambers” for the direct detection of sub-GeV dark matter. The spins in these macroscopic crystals effectively act as independent nanoscale magnets. When antialigned with an external magnetic field they form metastable states with a relaxation time that can be very long at sufficiently low temperatures. The Zeeman energy stored in this system can be released through localized heating, caused for example by the scattering or absorption of dark matter, resulting in a spin avalanche (or “magnetic deflagration”) that amplifies the effects of the initial heat deposit, enabling detection. Much like the temperature and pressure in a conventional bubble chamber, the temperature and external magnetic field set the detection threshold for a single molecule magnet crystal. Here, we discuss this detector concept for dark matter detection and propose ways to ameliorate backgrounds. If successfully developed, this detector concept can search for hidden photon dark matter in the meV–eV mass range with sensitivities exceeding current bounds by several orders of magnitude.
The signal-to-noise ratios have been derived for IPDA lidar using a direct detection receiver for both pulsed and sinewave laser modulation techniques, and the results and laboratory measurements are presented
The Earth's velocity relative to the Sun in galactic coordinates is required in the rate calculation for direct detection experiments. We provide a rigorous derivation of this quantity to first order in the eccentricity of the Earth's orbit. We also discuss the effect of the precession of the equinoxes, which has hitherto received little explicit discussion. Comparing with other expressions in the literature, we confirm that the expression of Lee, Lisanti and Safdi is correct, while the expression of Lewin and Smith, the de facto standard expression, contains an error. For calculations of the absolute event rate, the leading order expression is sufficient while for modulation searches, an expression with the eccentricity is required for accurate predictions of the modulation phase.
Mirror dark matter offers a framework to explain the existing dark matter direct detection experiments. Here we confront this theory with the most recent experimental data, paying attention to the various known systematic uncertainties, in quenching factor, detector resolution, galactic rotational velocity, and velocity dispersion. We perform a detailed analysis of the DAMA and CoGeNT experiments assuming a negligible channeling fraction and find that the data can be fully explained within the mirror dark matter framework. We also show that the mirror dark matter candidate can explain recent data from the CDMS/Ge, EdelweissII, and CRESSTII experiments and we point out ways in which the theory can be further tested in the near future.
In this work, we present the first direct-detection search for sub-GeV dark matter using a new ~2-gram high-resistivity Skipper CCD from a dedicated fabrication batch that was optimized for dark matter searches. Using 24 days of data acquired in the MINOS cavern at the Fermi National Accelerator Laboratory, we measure the lowest rates in silicon detectors of events containing one, two, three, or four electrons, and achieve world-leading sensitivity for a large range of sub-GeV dark matter masses. Data taken with different thicknesses of the detector shield suggest a correlation between the rate of high-energy tracks and the rate of single-electron events previously classified as “dark current.” We detail key characteristics of the new Skipper CCDs, which augur well for the planned construction of the ~100-gram SENSEI experiment at SNOLAB.
A technique for word timing recovery in a direct-detection optical PPM communication system is described. It tracks on back-to-back pulse pairs in the received random PPM data sequences with the use of a phase locked loop. The experimental system consisted of an 833-nm AlGaAs laser diode transmitter and a silicon avalanche photodiode photodetector, and it used Q = 4 PPM signaling at source data rate 25 Mb/s. The mathematical model developed to describe system performance is shown to be in good agreement with the experimental measurements. Use of this recovered PPM word clock with a slot clock recovery system caused no measurable penalty in receiver sensitivity. The completely self-synchronized receiver was capable of acquiring and maintaining both slot and word synchronizations for input optical signal levels as low as 20 average detected photons per information bit. The receiver achieved a bit error probability of 10 to the -6th at less than 60 average detected photons per information bit.
In this Letter, we pointed out that additional direct detection sensitivity to dark matter (DM) in the 10 keV–10 MeV mass range is possible through consideration of “reflected DM” initially scattered by more energetic electrons in the Sun (or Earth) prior to scattering in the terrestrial underground detector.
A technique is described for simulating the random modulation imposed by atmospheric scintillation and transmitter pointing jitter on a direct detection optical communication system. The system is capable of providing signal fading statistics which obey log normal, beta, Rayleigh, Ricean or chi-squared density functions. Experimental tests of the performance of the Channel Simulator are presented.
Motivated by the recent XENON 1T results, we explore various new physics models that can be discovered through searches for electron recoils in O(keV)-threshold direct-detection experiments. First, we consider the absorption of axion-like particles, dark photons, and scalars, either as dark matter relics or being produced directly in the Sun. In the latter case, we find that keV mass bosons produced in the Sun provide an adequate fit to the data but are excluded by stellar cooling constraints. We address this tension by introducing a novel Chameleon-like axion model, which can explain the excess while evading the stellar bounds. We find that absorption of bosonic dark matter provides a viable explanation for the excess only if the dark matter is a dark photon or an axion. In the latter case, photophobic axion couplings are necessary to avoid X-ray constraints. Second, we analyze models of dark matter-electron scattering to determine which models might explain the excess. Standard scattering of dark matter with electrons is generically in conflict with data from lower-threshold experiments. Momentum-dependent interactions with a heavy mediator can fit the data with dark matter mass heavier than a GeV but are generically in tension with collider constraints. Next, we consider dark matter consisting of two (or more) states that have a small mass splitting. The exothermic (down)scattering of the heavier state to the lighter state can fit the data for keV mass splittings. Finally, we consider a subcomponent of dark matter that is accelerated by scattering off cosmic rays, finding that dark matter interacting though an O(100 keV)-mass mediator can fit the data. The cross sections required in this scenario are, however, typically challenged by complementary probes of the light mediator. Throughout our study, we implement an unbinned Monte Carlo analysis and use an improved energy reconstruction of the XENON 1T events.