At least 181 records · Page 10

Exploiting a Shortcoming of Coupled-Cluster Theory: The Extent of Non-Hermiticity as a Diagnostic Indicator of Computational Accuracy

The fundamental non-Hermitian nature of the forms of the coupled-cluster (CC) theory widely used in quantum chemistry has usually been viewed as a negative, but the present paper shows how this can be used to an advantage. Specifically, the non-symmetric nature of the reduced one-particle density matrix (in the molecular orbital basis) is advocated as a diagnostic indicator of computational quality. In the limit of the full coupled-cluster theory [which is equivalent to full configuration interaction (FCI)], the electronic wave function and correlation energy are exact within a given one-particle basis set, and the symmetric character of the exact density matrix is recovered. The extent of the density matrix asymmetry is shown to provide a measure of “how difficult the problem is” (like the well-known T 1 diagnostic), but its variation with the level of theory also gives information about “how well this particular method works”, irrespective of the difficulty of the problem at hand. The proposed diagnostic is described and applied to a select group of small molecules, and an example of its overall utility for the practicing quantum chemist is illustrated through its application to the beryllium dimer (Be 2 ). Future application of this idea to excited states, open-shell systems, and symmetry-breaking problems and an extension of the method to the two-particle density are then proposed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Interface diagnostics platform for thin-film solid-state batteries

Understanding the impedances of battery materials and their interfaces remains a major challenge, usually addressed by electrochemical impedance spectroscopy (EIS) where frequency-dependent complex impedance of full battery cells is measured and then modeled by a network of connected electrical elements. As conventionally applied, this approach produces ambiguity in that (1) multiple different network configurations may fit the data convincingly and (2) the method offers no direct association of the electrical elements with physical features of the battery. Here we present a new methodology that resolves both sources of ambiguity, enabled by expanding the experimental scope to directly inform the configuration of elements and their parameters in the network model. We demonstrate this methodology using thin film fabrication of solid state battery devices patterned by shadow masked sputter deposition, so that diagnostic devices corresponding to individual interface and material components can be fabricated simultaneously with full cell batteries. EIS models for the diagnostic devices can then be connected to form full cell networks whose topology matches the well-known physical configuration of the battery. When connected in this way, the full network model – made from connecting the diagnostic device EIS models – fits the full cell EIS data. For the case of a thin film solid state battery composed of amorphous silicon anode, lithium phosphorus oxynitride (LiPON) solid electrolyte, and lithium vanadium oxide (Li x V 2 O 5 ) cathode, we show that the approach allows us to identify ionic impedance/conductivity of the cathode/electrolyte as a limiting impedance and the anode/electrolyte interface cycling instability as a primary degradation factor.

25 ENERGY STORAGE↗

A magnetic diagnostic suite for the Pegasus-III experiment

Pegasus-III is an ultralow aspect ratio spherical tokamak providing a dedicated US experiment for comparative solenoid-free startup studies. A new magnetic diagnostic suite for equilibrium and low frequency (<200 kHz) magnetohydrodynamic mode analysis has been installed. These new diagnostics address the significant challenges of measuring magnetic field in a high noise environment with the majority constrained to fit in an 8 mm diagnostic gap on the high field side. Electrostatic switching noise generated by the 16 independent current feedback-controlled power supplies produces dV cm /dt ~ 1 kV/μs and volt level common mode noise on the magnetics. Immunity to this switching noise is accomplished through differential signal runs and signal processing, along with end-to-end electromagnetic interference shielding. The magnetic measurements are simultaneously digitized at 1 MHz and conditioned by precision 8 pole Butterworth filters with a corner frequency of 200 kHz to prevent aliasing down to the 16-bit level over the full passband. Ex-vessel calibrations of the B p coils were completed with a typical uncertainty of <0.5%. Stray toroidal field pickup from coil misalignment or positioning errors is corrected using a physics-based model. Comparisons of the corrected measurements to modeling agree to within 1.3% on average. This is within the 1.5% measurement uncertainty that a sensitivity analysis determined is needed for accurate fast boundary and equilibrium reconstruction.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Impact of various DIII-D diagnostics on the accuracy of neural network surrogates for kinetic EFIT reconstructions

Abstract Kinetic equilibrium reconstructions make use of profile information such as particle density and temperature measurements in addition to magnetics data to compute a self-consistent equilibrium. They are used in a multitude of physics-based modeling. This work develops a multi-layer perceptron (MLP) neural network (NN) model as a surrogate for kinetic Equilibrium Fitting (EFITs) and trains on the 2019 DIII-D discharge campaign database of kinetic equilibrium reconstructions. We investigate the impact of including various diagnostic data and machine actuator controls as input into the NN. When giving various categories of data as input into NN models that have been trained using those same categories of data, the predictions on multiple equilibrium reconstruction solutions (poloidal magnetic flux, global scalars, pressure profile, current profile) are highly accurate. When comparing different models with different diagnostics as input, the magnetics-only model outputs accurate kinetic profiles and the inclusion of additional data does not significantly impact the accuracy. When the NN is tasked with inferring only a single target such as the EFIT pressure profile or EFIT current profile, we see a large increase in the accuracy of the prediction of the kinetic profiles as more data is included. These results indicate that certain MLP NN configurations can be reasonably robust to different burning-plasma-relevant diagnostics depending on the accuracy requirements for equilibrium reconstruction tasks.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Proposed framework for applying squeezed light to multi-photon absorption plasma diagnostics

We propose a quantum-enhanced plasma diagnostic based on squeezed states of light. Squeezed light can exhibit super-Poissonian photon statistics, leading to enhanced multiphoton absorption cross-sections compared to classical light. This effect enables improved sensitivity for two-photon excitation of high-energy atomic transitions such as ground-state excitation, and results in increased absorbed power and fluorescence in a plasma. We consider two methods of generating squeezed states and evaluate their advantages and limitations in the context of plasma absorption diagnostics. By comparing with and extending previous theoretical work, we predict an enhancement of the absorption signal by up to seven orders of magnitude at low intensities (10 1 W/m 2 ), with diminishing enhancement persisting up to high intensities (10 10 W/m 2 ). These results suggest that squeezed-light sources offer a viable pathway toward quantum-enhanced plasma diagnostics.

imaging↗

A differentiable simulation package for performing inference of synchrotron-radiation-based diagnostics

The direction of particle accelerator development is ever-increasing beam quality, currents and repetition rates. This poses a challenge to traditional diagnostics that directly intercept the beam due to the mutual destruction of both the beam and the diagnostic. An alternative approach is to infer beam parameters non-invasively from the synchrotron radiation emitted in bending magnets. However, inferring the beam distribution from a measured radiation pattern is a complex and computationally expensive task. To address this challenge we present SYRIPY ( SYnchrotron Radiation In PYthon ), a software package intended as a tool for performing inference of synchrotron-radiation-based diagnostics. SYRIPY has been developed using PyTorch , which makes it both differentiable and able to leverage the high performance of GPUs, two vital characteristics for performing statistical inference. The package consists of three modules: a particle tracker, Lienard–Wiechert solver and Fourier optics propagator, allowing start-to-end simulation of synchrotron radiation detection to be carried out. SYRIPY has been benchmarked against SRW , the prevalent numerical package in the field, showing good agreement and up to a 50× speed improvement. Finally, we have demonstrated how SYRIPY can be used to perform Bayesian inference of beam parameters using stochastic variational inference.

43 PARTICLE ACCELERATORS↗

ENSO-Induced Teleconnection: Process-Oriented Diagnostics to Assess Rossby Wave Sources and Ambient Flow Properties in Climate Models

Climate model fidelity in representing ENSO-induced teleconnection is assessed with process-oriented diagnostics that examine a chain of processes, from equatorial Pacific precipitation to the midlatitude circulation pattern over the Pacific–North American regions. Such processes are rarely addressed during model development. Using an upper-tropospheric divergent level, local vorticity gradient of the ambient zonal flow (∂ 2 U¯/∂y 2 ) and a restoring force for Rossby waves (β * ) are estimated, the equivalent barotropic vorticity equation is solved, and an anomalous Rossby wave source (RWS') quantified. The analysis is applied to AMIP5 and AMIP6 simulations. For a realistic circulation response representation, the hypothesis that models accurately represent the strength and location of RWS', and spatial variations in β * is tested. Compared to AMIP5, in AMIP6 there are clear improvements in representing RWS' and β * . To validate the hypothesis, the analysis identifies two metrics: spatially coherent RWS' in the subtropical North Pacific, and longitudes of negative β * over the western-central North Pacific. By projecting these metrics in two and three-dimensional views, improvements or degradations in model versions are apparent. If a model’s fidelity in representing ∂ 2 U¯/∂y 2 and RWS' are compromised, then radiated Rossby waves are reflected more equatorward, resulting in zonally elongated circulation anomalies over the central North Pacific. Thus, during climate model development, applying this analysis frequently will keep a regular check on the fidelity of the modeled response to anomalous El Niño convection in conjunction with changing model ambient flow dependencies. As a result, this analysis is intended to form a process-oriented diagnostics package, a community contribution to the NOAA Model Diagnostics Task Force.

54 ENVIRONMENTAL SCIENCES↗

Predicting antimicrobial resistance in Pseudomonas aeruginosa with machine learning-enabled molecular diagnostics

Limited therapy options due to antibiotic resistance underscore the need for optimization of current diagnostics. In some bacterial species, antimicrobial resistance can be unambiguously predicted based on their genome sequence. In this study, we sequenced the genomes and transcriptomes of 414 drug-resistant clinical Pseudomonas aeruginosa isolates. By training machine learning classifiers on information about the presence or absence of genes, their sequence variation, and expression profiles, we generated predictive models and identified biomarkers of resistance to four commonly administered antimicrobial drugs. Using these data types alone or in combination resulted in high (0.8–0.9) or very high (> 0.9) sensitivity and predictive values. For all drugs except for ciprofloxacin, gene expression information improved diagnostic performance. Our results pave the way for the development of a molecular resistance profiling tool that reliably predicts antimicrobial susceptibility based on genomic and transcriptomic markers. Finally, the implementation of a molecular susceptibility test system in routine microbiology diagnostics holds promise to provide earlier and more detailed information on antibiotic resistance profiles of bacterial pathogens and thus could change how physicians treat bacterial infections.

59 BASIC BIOLOGICAL SCIENCES↗

A laser inverse Compton scattering diagnostic to study runaway electron dynamics during tokamak disruptions

Both technical and simulation progress has been made toward implementing a laser inverse Compton scattering diagnostic on the DIII-D tokamak. This is a novel diagnostic which uses a short (sub-ns) pulse laser together with a fast (sub-ns) gated x-ray detector to measure relativistic electrons inside a tokamak plasma. The study of these relativistic electrons is important to make sure they can be removed from any tokamak-based power reactor, as they could damage vessel walls and cooling lines. This diagnostic is completely new for magnetic fusion research and has never been implemented before on a tokamak. It is found that good signals and radial profiles could be obtained with an optimized high-energy (7 Joule) laser. Using a standard off-the-shelf Nd:YAG (0.7 Joule) laser would give some signals above the noise but no ability to measure the relativistic electron radial profile.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

LLE Diagnostic Resource Team for Innovative Fusion Concepts (Final Report)

The LLE Diagnostic Resource Team for Innovative Fusion Concepts provided travelling neutron diagnostics, consultancy on neutron diagnostics, and consultancy on tritium handling to fusion companies. An existing neutron detector was recalibrated for low yields and two detectors were built based on designs proven on the Omega Laser Facility. The three detectors allow measurements over a wide range of yields (from 10 to 1E7 incident neutrons). The detectors were calibrated for DD neutrons on a dedicated OMEGA shot day. Neutron detectors from the company MIFTI were also calibrated on OMEGA. MIFTI is currently using their detectors and two of our detectors on staged Z-pinch experiments at UCSD. The Team acted as consultants for the development of a liquid scintillator array to detect neutrons from muon induced fusion by NK Labs. Segments of NK Labs’ detector were tested at the LLE using radioactive sources and a DD neutron generator. The Team also acted as consultants for the design of a tritium handling system for NK Labs. A new type of neutron spectrometer was designed and built, and has completed preliminary testing.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Recommendations for Minimum Required Diagnostics Information for Electric Vehicle Charging Infrastructure

The rapid growth of electrified transportation, including light- and medium-duty electric vehicles (EVs) as a mobility solution requires a reliable EV charging infrastructure. To advance charging reliability, the ChargeX Consortium reports “Recommendations for Minimum Required Error Codes for Electric Vehicle Charging Infrastructure” and “Implementation Guide for Minimum Required Error Codes in Electric Vehicle Charging Infrastructure” have provided recommendations for a set of minimum required error codes (MRECs), their functional and responsibility classifications, and a guide for their implementation using OCPP versions 1.6J and 2.0.1. These reports outline a recommended practice for consistent error reporting and interpretation, which is essential for communicating issues uniformly across the complex and diverse EV charging ecosystem. However, MRECs are just one part of diagnosing issues, another critical part is obtaining enough information about the current state and performance of the various charging components to identify root causes for each of the error codes. This additional diagnostics data can be used by technicians or automated systems to understand the context around an issue, allowing for timely resolution, decreased maintenance costs, and increased charging reliability. During everyday operations, data is regularly collected and analyzed across the ecosystem. Although sharing of all that available data would be great for diagnostics, concerns on data ownership, privacy, and OEM intellectual property pose a challenge. To overcome this obstacle, this report proposes a set of Minimum Required Diagnostic Information (MRDI) and recommends that the industry implement these uniformly across the North American EV charging ecosystem. MRDI provides a means to exchange only data deemed necessary for root cause determination.

32 - ENERGY CONSERVATION, CONSUMPTION, AND UTILIZA↗

Diagnostic Methodologies of Laser-Initiated 11 B(p,α)2α Fusion Reactions

The detection of the ionic products of low-rate fusion reactions, and in particular of the 11 B(p,α)2α, is one of the recognized main problems in experiments where these reactions are initiated by tailored interaction of intense and high-energy lasers with matter. A thorough description of this important issue, with a critical comparison of the diagnostic opportunities, is indeed so far. In this work, we describe the common diagnostic methodologies used for the detection of the alpha particles generated by the 11 B(p,α)2α reaction and, for each, we outline advantages and limitations, with considerations that can also be applied to other low-rate fusion reactions. We show here that, in general, the univocal characterization of the α products coming from this reaction can be achieved by the simultaneous use of several diagnostic tools placed in close proximity.

11B(p,α)2α reactions↗

An Ensemble Investigation of the Causes for Regional Air-Quality Model Critical Load Exceedances Prediction Variability in European and North American Domains Using Diagnostics From Phase 4 of the Air Quality Model Evaluation International Initiative

We summarize tentative findings from multi air quality model ensembles for the years 2009 and 2010 in Europe (EU), and 2010 and 2016 in North America (NA), under AQMEII-4. The model predictions of sulphur and nitrogen deposition were used to estimate exceedances of critical loads for acidification and eutrophication, to show the extent to which the ensemble members agree in the magnitude and the trend of ecologically meaningful impacts. Model exceedance variability was analyzed using AQMEII-4 diagnostics. Evaluation against concentration and wet deposition observations, coupled with these diagnostics, identified specific process representations as the causes for variability between model predictions and for reduced model performance. All models predicted reductions in ecosystem acidification impacts in North America between the years 2010 and 2016, in accord with SO2 emissions reduction legislation which started in 2010 (SO2 SIP) However, all models in EU and NA domains had net negative biases for wet deposition of sulphur and nitrogen relative to observations. The wet S deposition average mean bias for the NA ensemble was -0.17 eq ha-1 d-1, and for the EU ensemble -1.15 eq ha-1 d-1. The NA daily wet deposition average mean bias for NH4+ was -0.37 eq ha-1d-1; EU -1.19 eq ha-1 d-1. The daily NA wet NO3- deposition average mean bias was -0.24 eq ha-1d-1; EU -0.69 eq ha-1 d-1. The members of the ensemble diverged (factor of 10) in their North American predictions for Ndep and consequently their eutrophication exceedances. The models with the highest eutrophication predictions also predicted the highest levels of gas-phase ammonia dry deposition (standard deviation of ammonia dry deposition flux across ensemble members was larger than the ensemble average). These models also had negative biases of predicted ammonia concentrations; average mean biases of -0.63 (satellite NH3) and -0.85 ppbv (surface NH3) compared to ensemble averages of -0.30 and -0.34 ppbv. Diagnostics showed that these differences resulted from the manner in which bidirectional ammonia fluxes were parameterized within these models. The second largest source of NA eutrophication prediction variability were models with positive biases in particulate ammonium and nitrate concentrations, and higher particle nitrogen deposition levels ( particle ammonium concentration bias +0.35 ug m-3; ensemble bias +0.15 ug m-3). We believe two factors may have led to these latter overestimates: higher levels of fine mode particle nitrate formation compared to other models (due to the use of an inorganic heterogeneous chemistry algorithm which did not take base cation chemistry into account), and updates to particle dry deposition velocities carried out in the absence of concurrent updates to wet scavenging algorithms. The relative importance of dry gas, dry particulate, and wet deposition towards total sulphur and nitrogen deposition totals differed between EU and North American domains, though all models had negative biases in wet deposition as noted above. Parallel and subsequent work suggests that multiphase hydrometeor scavenging may improve model wet deposition performance. An increased research focus is recommended for four model processes: multiphase hydrometeor scavenging, ammonia bidirectional fluxes, base cation chemistry and emissions, and particle dry deposition.

regional air-quality model↗

Polarimetry-Interferometry Diagnostic for Magnetic Field and Magnetic Fluctuation Measurements in High-Performance and Long-Pulse Tokamaks (Final Report)

In this grant, we executed a multi-year plan to develop an advanced Faraday-effect polarimeter-interferometer system to address both fluctuation and equilibrium diagnostic needs by providing a measurement of the plasma internal magnetic field fluctuations (including non-axisymmetric 3-D perturbations) and plasma vertical position. This diagnostic included both fast time response and low phase noise so that both the temporal dynamics of equilibrium quantities as well as high-frequency electromagnetic fluctuations could be measured simultaneously, adding new and unique measurement capabilities for the core of high-temperature plasmas. The combined polarimeter-interferometer diagnostic development was applied primarily to the tokamak magnetic configuration, focusing on high-performance regimes including H-mode, reversed shear advanced tokamak scenarios, and non-inductive current drive.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Integration of Condition-Based, Diagnostic, Prognostic, And Anomaly Detection Data into Reliability Models to Support a Predictive Maintenance Context

Reliability data employed in plant reliability models are an approximated integral representation of the past industrywide operational experience, and they neglect the present asset health status (available, for example, from online monitoring data and diagnostic assessments) and forecasted health projection (when available from prognostic models). Ideally, in a predictive maintenance context, system reliability models should support decision making by propagating actual health information from the asset to the system level in order to provide a quantitative snapshot of system health and identify the most critical assets. Asset health should be informed solely by that specific asset’s current and historical performance data and should not be an approximated integral representation of the past industrywide operational experience (as currently performed by system reliability models through Bayesian updating processes). This paper proposes a reliability modeling approach that relies on asset diagnostic and prognostic assessments, along with monitoring data to measure asset health. We show how state-of-the art condition-based, diagnostic, prognostic, and anomaly detection models can be linked to system reliability models not in probability terms, but in terms of margin where margin is defined as the “distance” between the present status and an undesired event (e.g., failure or unacceptable performance). Then, we show how the propagation of margin data from the asset to the system level is performed through classical reliability models such as fault trees or reliability block diagrams. The described method is in fact able to propagate heterogenous health data from the asset to the system level in order to analytically assess system health.

97 MATHEMATICS AND COMPUTING↗

Megahertz Rate Optical Diagnostics of Explosively Generated Soot

Detonation of a solid explosive produces a turbulent and luminous post‐detonation fireball containing condensed carbon soot. Diagnostics of soot dynamics are needed for model validation and to interpret emission signals. Diffuse back‐illumination extinction imaging (DBI‐EI) and laser‐induced incandescence (LII) are two common optical diagnostics for flame soot. This work extends both to measure time‐resolved soot dynamics from a 12 mm HMX hemisphere. DBI‐EI measured line‐of‐sight optical extinction exceeds 99% in some regions. Results are tomographically inverted to obtain a signal proportional to the soot volume fraction. Pulse‐burst LII measures are presented at 1 MHz. For the first time, LII results are combined with DBI‐EI extinction measurements to quantify and correct for signal trapping. Following this, spatially and temporally resolved DBI‐EI and LII measures are shown to be in reasonable agreement. Finally, experimental results are compared against recently developed simulations. Quantitative differences in the soot mixing dynamics are resolved. These findings motivate future model improvements and demonstrate ongoing needs for diagnostic advancements for heavily sooting environments.

diffuse back-illumination extinction imaging↗

Diagnostic imaging of hepatocellular carcinoma at community hospitals and their tertiary referral center in the era of LI-RADS: a quality assessment study

Purpose: To assess guideline compliance and quality of hepatocellular carcinoma, (HCC) diagnostic imaging within community hospitals (CH) and their Tertiary referral center (TRC) in a moderately high incidence region. Methods: Initial diagnostic workup CT/MRI scans of 251 patients (122 CH, 112 TRC, 17 Non-TRC academic) with HCC over a 15-month period were assessed for Liver reporting and Data System (LI-RADS) guideline compliance. 269 scans (182 CT, 87 MRI) were qualitatively evaluated by 2 independent blinded radiologists for arterial timing, overall image quality, noise and sharpness, with quantification of interobserver variability. The contrast enhancement ratio (CER) for the largest HCC on each scan was calculated using pre- and post-contrast images. Results: 103/104 (99%) of TRC and 44/78 (56%) of CH CTs adhered to LI–RADS imaging guidelines (P < 0.0001). Lack of delayed phase accounted for 32/34 (94%) of noncompliant CH CTs. Regarding MRI, 19/19 (100%) of TRC and 60/68 (88%) of CH scans were adherent (P = 0.12). For both modalities, overall image quality, noise and sharpness were rated significantly higher for TRC than CH. There was moderate interobserver agreement with intraclass correlation coefficient of 0.73, 0.70 and 0.63, respectively. Arterial-phase timing was rated adequate for CT in 75/104 TRC (72%) and 10/68 (14%) CH scans (P < 0.0001) and for MRI in 8/19 (42%) TRC and 23/68 (33%) CH scans (P = 0.17). The CER was significantly higher for TRC versus CH (2.9 vs. 1.9, P < 0.001) and MRI (0.9 vs. 0.7, P = 0.03). Conclusions: Community hospital HCC diagnostic scans significantly lag in critical quality parameters of tumor enhancement, arterial phase timing, perceived image quality, and LI-RADS CT technique compliance compared to a TRC.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Two-color pyrometry based flame to fuel surface radiative heat flux diagnostic using flamelets

In this study, a non-intrusive two-color pyrometry based radiative heat flux diagnostic is presented that accounts for the self-absorption effects. This diagnostic relies on looking up the flame temperature and soot volume fraction using the ratio of color intensities obtained from digital cameras and numerical solutions of 1D steady-state diffusion flames. Virtual two color pyrometry of computed flame show a unique one-to-one mapping of strained flames with intensity ratio; thereby allowing flames to be indexed and creation of a two-color flamelet manifold (TCFM). The TCFM is a function of two variables; the ratio of red to green intensities (flame index) and physical distance to the stoichiometric surface defined using a level-set function. The developed diagnostic is used in upward flame spread experiments where an approximate flame hull reconstruction method is applied to provide the 3D level-set function and intensity ratio for use of TCFM to provide radiative absorption properties for 3D ray tracing. Accounting for self- absorption effects provide improved soot volume fraction estimates. In conclusion, the radiative heat flux estimates are found to be in very good agreement with literature and improved results are obtained near the flame base.

42 ENGINEERING↗