Studies of magnetocaloric effect on spin-1/2 J{sub 1}-J{sub 2} Heisenberg hexagons

Magnetocaloric effect of four different spin-1/2 J{sub 1}-J{sub 2} Heisenberg hexagons has been studied in terms of adiabatic demagnetization. Four hexagons with different combinations of antiferromagnetic and ferromagnetic Heisenberg exchange interactions are considered. Level of frustration on those models is different. Studies on the magnetization process, nature of isentrops and properties of magnetocaloric effect have been carried out. Comparison of results on those models has been discussed.

36 MATERIALS SCIENCE↗

Perspective: Ultrafast magnetism and THz spintronics

This year the discovery of femtosecond demagnetization by laser pulses is 20 years old. For the first time, this milestone work by Bigot and coworkers gave insight directly into the time scales of microscopic interactions that connect the spin and electron system. While intense discussions in the field were fueled by the complexity of the processes in the past, it now became evident that it is a puzzle of many different parts. Rather than providing an overview that has been presented in previous reviews on ultrafast processes in ferromagnets, this perspective will show that with our current depth of knowledge the first applications are developed: THz spintronics and all-optical spin manipulation are becoming more and more feasible. The aim of this perspective is to point out where we can connect the different puzzle pieces of understanding gathered over 20 years to develop novel applications. Based on many observations in a large number of experiments. Differences in the theoretical models arise from the localized and delocalized nature of ferromagnetism. Transport effects are intrinsically non-local in spintronic devices and at interfaces. We review the need for multiscale modeling to address the processes starting from electronic excitation of the spin system on the picometer length scale and sub-femtosecond time scale, to spin wave generation, and towards the modeling of ultrafast phase transitions that altogether determine the response time of the ferromagnetic system. Today, our current understanding gives rise to the first usage of ultrafast spin physics for ultrafast magnetism control: THz spintronic devices. This makes the field of ultrafast spin-dynamics an emerging topic open for many researchers right now.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Transient enhancement of magnetization damping in CoFeB film via pulsed laser excitation

Laser-induced spin dynamics of in-plane magnetized CoFeB films has been studied by using time-resolved magneto-optical Kerr effect measurements. While the effective demagnetization field shows little dependence on the pump laser fluence, the intrinsic damping constant has been found to be increased from 0.008 to 0.076 with the increase in the pump fluence from 2 mJ/cm{sup 2} to 20 mJ/cm{sup 2}. This sharp enhancement has been shown to be transient and ascribed to the heating effect induced by the pump laser excitation, as the damping constant is almost unchanged when the pump-probe measurements are performed at a fixed pump fluence of 5 mJ/cm{sup 2} after irradiation by high power pump pulses.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magnetic cooling close to a quantum phase transition—The case of Er{sub 2}Ti{sub 2}O{sub 7}

Magnetic cooling, first introduced in the late twenties of last century, has regained considerable interest recently as a cost-efficient and easy-to-handle alternative to {sup 3}He-based refrigeration techniques. Especially, adiabatic demagnetization of paramagnets—the standard materials for magnetic refrigeration—has become indispensable for the present space applications. To match the growing demand for increasing the efficiency in these applications, a new concept for magnetic cooling based on many-body effects around a quantum-critical-point has been introduced and successfully tested [B. Wolf et al., Proc. Natl. Acad. Sci. U.S.A. 108, 6862 (2011)]. By extending this concept to three-dimensional magnetic systems, we present here the magnetothermal response of the cubic pyrochlore material Er{sub 2}Ti{sub 2}O{sub 7} in the vicinity of its B-induced quantum-critical point which is located around 1.5 T. We discuss performance characteristics such as the range of operation, the efficiency, and the hold time. These figures are compared with those of state-of-the-art paramagnetic coolants and with other quantum-critical systems which differ by the dimensionality of the magnetic interactions and the degree of frustration.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

A Novel $In-Situ$ Radiation Damage Diagnostic System for Undulators

Radiation damage has been a known problem at many synchrotron radiations and free-electron lasers facilities, especially those that use hybrid or pure permanent magnet undulators to produce high brightness light. Field strength loss due to demagnetization makes it necessary to remove the insertion device from the tunnel for inspection and repair, which brings several inconveniences. We aimed to develop an in situ radiation damage detection system for undulators capable of diagnosing relative field changes of 10 -4 (100 ppm) or smaller. The system measures the flux change in a flexible printed circuit board coil attached to the undulator magnet array by periodically measuring the integral flux change during the opening and closing of the undulator gap. If the magnet block damage occurs, the signal from the coil will decrease proportionally to the damage. First tests performed on variable gap hybrid undulators for the Linac Coherent Light Source II (LCLS-II) at SLAC National Accelerator Laboratory showed that the system is capable of measuring flux changes with a relative precision of approximately 0.7 × 10 -4 over several days. Relative field changes smaller than 10 -4 were detected in short-term measurements. Here, the novel system that we propose here opens the possibility of detecting radiation damage in undulators during operation.

47 OTHER INSTRUMENTATION↗

Unusual Behavior of the Coercive Field in a (CoFeB){sub x}(LiNbO{sub y}){sub 100 –x} Nanocomposite with a High Content of Magnetic Ions in an Insulating Matrix

The temperature behavior of the coercive field H{sub c}(T) and the magnetic anisotropy in (CoFeB){sub x}(LiNbO{sub y}){sub 100 –x} nanocomposite films with a ferromagnetic alloy content x = 33–48 at % near the metal–insulator transition (x{sub c} ≈ 42 at %) have been studied by the magnetometry and ferromagnetic resonance methods. The films were ensembles of CoFe granules with lateral sizes of 2–4 nm, which are highly elongated (up to 10–15 nm) in the nanocomposite growth direction and embedded in a LiNbO{sub y} matrix with a high content of magnetic Fe{sup 2+} and Co{sup 2+} ions (up to 3 × 10{sup 22} cm{sup –3}). A nonmonotonic behavior of H{sub c}(T), viz., a sharp minimum at a temperature T{sub F} ≈ 50 K close to the blocking temperature (T{sub b}{sup ∗} ≈ 70 K) of the granule magnetic moment, has been detected in samples with x < 42 at %. The effective field of the perpendicular growth anisotropy (0.4–0.8 kOe) turns out to be an order of magnitude lower than the field of the granule shape anisotropy (about 7 kOe) and increases with x. The revealed peculiarities are explained by the fact that, apart from the ferromagnetic intergranular exchange interaction in an infinite cluster, the surface anisotropy effects involving magnetic ions in a thin layer adjacent to the cluster and responsible for the surface interaction fluctuations play a big role in the investigated percolation nanocomposites, enhancing the nanocomposite demagnetization at T ≈ T{sub F} ~ T{sub b}{sup ∗}.

36 MATERIALS SCIENCE↗

Formation of gapless Z{sub 2} spin liquid phase manganites in the (Sm{sub 1–y}Gd{sub y}){sub 0.55}Sr{sub 0.45}MnO{sub 3} system in zero magnetic field: Topological phase transitions to states with low and high density of 2D-vortex pairs induced by the magnetic field

The evolution of the ground state of the manganese spin ensemble in the (Sm{sub 1–y}Gd{sub y}){sub 0.55}Sr{sub 0.45}MnO{sub 3} in the case of isovalent substitution of rare-earth samarium ions with large radii with gadolinium ions with significantly smaller radii is studied. The measured temperature dependences of the ac magnetic susceptibility and the field dependences of the dc magnetizations are analyzed using the Heisenberg–Kitaev model describing the transition from the ordered spin state with classical isotropic AFM exchange to the frustrated spin state with quantum highly anisotropic FM exchange. A continuous transition from the 3D ferromagnetic state of manganese spins in the initial sample with y = 0 to zigzag AFM ordering of CE-type spins in ab planes for y = 0.5, coexisting in samples with y = 0.5, 0.6, and 0.7 at temperatures below T{sub N} ≅ 48.5 K with a disordered phase such as a quantum Griffiths phase is identified. As the gadolinium concentration further increases, the CE-type zigzag AFM structure is molten, which leads to the appearance of an unusual phase in Gd{sub 0.55}Sr{sub 0.45}MnO{sub 3} in the temperature range close to the absolute zero. This phase has characteristic features of a gapless Z{sub 2} quantum spin liquid in zero external magnetic field. The step changes in the magnetization isotherms measured at 4.2 K in the field range of ±75 kOe are explained by quantum phase transitions of the Z{sub 2} spin liquid to a phase with topological order in weak magnetic fields and a polarized phase in strong fields. The significant difference between critical fields and magnetization jumps in isotherms indicates the existence of hysteretic phenomena in quantum spin liquid magnetization–demagnetization processes caused by the difference between localization–delocalization of 2D vortex pairs induced by a magnetic field in a quantum spin liquid with disorder.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Temporal Stability of Magnetization of ε-In{sub 0.24}Fe{sub 1.76}O{sub 3} Nanoparticles

The kinetics of spontaneous demagnetization in nanoparticles of the exotic epsilon-phase of indium-doped iron(III) oxide (ε-In{sub 0.24}Fe{sub 1.76}O{sub 3}) has been studied using the method of accelerated testing of magnets for temporal stability in a magnetization-reversal field. Time dependences of the magnetization of nanoparticles measured in a wide range of magnetic fields exhibited rectification in semilogarithmic coordinates. The dependence of the magnetic viscosity on the magnetic field has been measured and used for determining the fluctuation field and activation volume. A relationship between the magnetic viscosity and magnetic noise caused by random thermoinduced magnetization reversal in separate nanoparticles is established.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Final Report for DOE Grant # DE-FG02-01ER45893

During the period July 1, 2001 to June 30, 2016, the DOE-supported research project covered a significant number of research topics, all of them related to the study of magnetic materials. Part of this work was experimental but the main focus was on theoretical analyses of magnetic materials characterization approaches, such as Lorentz transmission electron microscopy (LTEM) using phase reconstructions; vector field electron tomography (VFET); and in-depth analyses of the demagnetization tensor field for uniformly magnetized particles of arbitrary shape. A total of 39 papers were published in peer-reviewed journals over the 16 years of this research program. In the following sub-sections, we list the abstracts for all 33 journal papers; the interested reader may find more details in the actual publications. Conference papers are also listed in the list of publications at the end of this report, but are not covered in the following sections due to the fact that these papers typically do not have an abstract.

36 MATERIALS SCIENCE↗

Performance Testing of the Astro-H Flight Model 3-Stage ADR

The Soft X-ray Spectrometer (SXS) is one of four instruments that will be flown on the Japanese Astro-H satellite, planned for launch in late 2015early 2016. The SXS will perform imaging spectroscopy in the soft x-ray band using a 6x6 array of silicon micro calorimeters operated at 50 mK, cooled by an adiabatic demagnetization refrigerator (ADR). NASAGSFC is providing the detector array and ADR, and Sumitomo Heavy Industries, Inc. is providing the remainder of the cryogenic system (superfluid helium dewar (1.3 K), Stirling cryocoolers and a 4.5 K Joule-Thomson (JT) cryocooler). The ADR is unique in that it is designed to use both the liquid helium and the JT cryocooler as it heat sink. The flight detector and ADR assembly have successfully undergone vibration and performance testing at GSFC, and have now undergone initial performance testing with the flight dewar at Sumitomo Heavy Industries, Inc. in Japan. This presentation summarizes the performance of the flight ADR in both cryogen-based and cryogen-free operating modes.

adiabatic demagnetization refrigerator↗

Optimization Strategies for Single-Stage, Multi-Stage and Continuous ADRs

Adiabatic Demagnetization Refrigerators (ADR) have many advantages that are prompting a resurgence in their use in spaceflight and laboratory applications. They are solid-state coolers capable of very high efficiency and very wide operating range. However, their low energy storage density translates to larger mass for a given cooling capacity than is possible with other refrigeration techniques. The interplay between refrigerant mass and other parameters such as magnetic field and heat transfer points in multi-stage ADRs gives rise to a wide parameter space for optimization. This paper first presents optimization strategies for single ADR stages, focusing primarily on obtaining the largest cooling capacity per stage mass, then discusses the optimization of multi-stage and continuous ADRs in the context of the coordinated heat transfer that must occur between stages. The goal for the latter is usually to obtain the largest cooling power per mass or volume, but there can also be many secondary objectives, such as limiting instantaneous heat rejection rates and producing intermediate temperatures for cooling of other instrument components.

sub-kelvin cooling↗

Heat Switches for ADRs

Heat switches are key elements in the cyclic operation of Adiabatic Demagnetization Refrigerators (ADRs). Several of the types of heat switches that have been used for ADRs are described in this paper. Key elements in selection and design of these switches include not only ON/OFF switching ratio, but also method of actuation, size, weight, and structural soundness. Some of the trade-off are detailed in this paper.

adiabatic demagnetization refrigerator↗

Operation of an ADR Using Helium Exchange Gas as a Substitute for a Failed Heat Switch

The Soft X-ray Spectrometer (SXS) is one of four instruments on the Japanese Astro-H mission, which is currently planned for launch in late 2015. The SXS will perform imaging spectroscopy in the soft X-ray band (0.3-12 keV) using a 6 6 pixel array of microcalorimeters cooled to 50 mK. The detectors are cooled by a 3-stage adiabatic demagnetization refrigerator (ADR) that rejects heat to either a superfluid helium tank (at 1.2 K) or to a 4.5 K Joule-Thomson (JT) cryocooler. Four gas-gap heat switches are used in the assembly to manage heat flow between the ADR stages and the heat sinks. The engineering model (EM) ADR was assembled and performance tested at NASA/GSFC in November 2011, and subsequently installed in the EM dewar at Sumitomo Heavy Industries, Japan. During the first cooldown in July 2012, a failure of the heat switch that linked the two colder stages of the ADR to the helium tank was observed. Operation of the ADR requires some mechanism for thermally linking the salt pills to the heat sink, and then thermally isolating them. With the failed heat switch unable to perform this function, an alternate plan was devised which used carefully controlled amounts of exchange gas in the dewar's guard vacuum to facilitate heat exchange. The process was successfully demonstrated in November 2012, allowing the ADR to cool the detectors to 50 mK for hold times in excess of 10 h. This paper describes the exchange-gas-assisted recycling process, and the strategies used to avoid helium contamination of the detectors at low temperature.

Adiabatic demagnetization↗

Operating Modes and Cooling Capabilities of the Flight ADR for the SXS Instrument on Astro-H

The microcalorimeter array on the Soft X-ray Spectrometer instrument on Astro-H requires cooling to 50 mK, which will be accomplished by a 3-stage adiabatic demagnetization refrigerator (ADR). The ADR is surrounded by a cryogenic system consisting of a superfluid helium tank, a 4.5 K Joule-Thomson (JT) cryocooler, and additional 2-stage Stirling cryocoolers that pre-cool the JT cooler and radiation shields within the cryostat. The unique ADR design allows the instrument to meet all of its science requirements using either the stored cryogen or the JT cryocooler as its heat sink, giving the instrument an unusual degree of tolerance for component failures or degradation in the cryogenic system. The flight detector assembly, ADR and dewar were integrated in early 2014, and have since been extensively characterized and calibrated. At present, the four instruments are being integrated with the spacecraft in preparation for an early 2016 launch. This presentation summarizes the operation and performance of the ADR in all of its operating modes.

adiabatic demagnetization refrigerator↗

Operating Modes and Cooling Capabilities of the 3-Stage ADR Developed for the Soft-X-Ray Spectrometer Instrument on Astro-H

A 3-stage adiabatic demagnetization refrigerator (ADR) is used on the Soft X-ray Spectrometer instrument on Astro-H to cool a 6x6 array of x-ray microcalorimeters to 50 mK. The ADR is supported by a cryogenic system consisting of a superfluid helium tank, a 4.5 K Joule-Thomson (JT) cryocooler, and additional 2-stage Stirling cryocoolers that pre-cool the JT cooler and cool radiation shields within the cryostat. The ADR is configured so that it can use either the liquid helium or the JT cryocooler as its heat sink, giving the instrument an unusual degree of tolerance for component failures or degradation in the cryogenic system. The flight detector assembly, ADR and dewar were integrated into the flight dewar in early 2014, and have since been extensively characterized and calibrated. This paper summarizes the operation and performance of the ADR in all of its operating modes

x-ray astronomy↗

ADR Design and Operation for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite 38 days after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called XARM. XARM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). For XARM, the spectrometer instrument named Resolve will be rebuilt to the original SXS design. It consists of a 6x6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage adiabatic demagnetization refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5 K Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XARM ADR and how it differs from the SXS version, and will briefly summarize on-orbit ADR performance during Hitomi's operational period.

adiabatic demagnetization refrigeration↗

3-Stage ADR for the X-Ray Imaging and Spectrometer Mission (XRISM)

Following the loss of the Hitomi x-ray astronomy satellite shortly after its launch in early 2016, the US and Japanese space agencies (NASA and JAXA) agreed to fund a replacement mission, presently called the X-Ray Imaging and Spectroscopy Mission (XRISM). XRISM will include only the two soft x-ray instruments from Hitomi, the Soft X-ray Spectrometer (SXS), and the Soft X-ray Imager (SXI). The spectrometer instrument, now named Resolve, will be similar to the original SXS design. It consists of a 6 by 6 array of silicon microcalorimeters cooled to 50 millikelvin by means of a 3-stage Adiabatic Demagnetization Refrigerator (ADR) whose operation is supported by a 40 liter superfluid helium tank, a 4.5-degrees-Kelvin Joule-Thomson cryocooler and a number of 2-stage Stirling cryocoolers. These components were all successfully demonstrated on Hitomi before its failure. This talk will summarize the design of the XRISM ADR and how it differs from the SXS version.

ADR (Adiabatic Demagnetization Refrigerator)↗

Superfluid-Tight Cryogenic Receiver With Continuous Sub-Kelvin Cooling for EXCLAIM

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a balloon-borne telescope designed to survey star formation over cosmological time scales using intensity mapping in the 420 – 540 GHz frequency range. EXCLAIM uses a fully cryogenic telescope coupled to six on-chip spectrometers featuring kinetic inductance detectors (KIDs) to achieve high sensitivity, allowing for fast integration in dark atmospheric windows. The telescope receiver is cooled to ≈ 1.7 K by immersion in a superfluid helium bath and enclosed in a superfluid-tight shell with a meta-material anti-reflection coated silicon window. In addition to the optics and the spectrometer package, the receiver contains the magnetic shielding, the cryogenic segment of the spectrometer readout, and the sub-Kelvin cooling system. A three-stage continuous adiabatic demagnetization refrigerator (CADR) keeps the detectors at 100 mK while a 4He sorption cooler provides a 900 mK thermal intercept for mechanical suspensions and coaxial cables. We present the design of the EXCLAIM receiver and report on the flight-like testing of major receiver components, including the superfluid-tight receiver window and the sub-Kelvin coolers.

continuous adiabatic demagnetization refrigerator↗