Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Dehumidification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Photovoltaic-electrodialysis regeneration method for liquid desiccant cooling system

Liquid desiccant cooling system (LDCS) is an (a novel) air-conditioning system with good energy saving potential. Regenerator is the power centre for LDCS. Currently, the regeneration process is always fuelled by thermal energy. Nevertheless, this regeneration pattern has some disadvantages in that its performance will become poor when the surrounding atmosphere is of high humidity, and the heat provided for regeneration will be unfavourable to the following dehumidification process. To ameliorate that, a new regeneration method is proposed in this paper: a membrane regenerator is employed to regenerate the liquid desiccant in an electrodialysis way; while solar photovoltaic generator is adopted to supply electric power for this process. Analysis has been made about this new regeneration method and the result reveals: this new manner achieves good stability with the immunity against the adverse impact from the outside high humidity; its performance is much higher than that of the thermal regeneration manner while putting aside the low efficiency of the photovoltaic system. Besides, purified water can be obtained in company with the regeneration process. (author)

14 SOLAR ENERGY↗

High-Throughput Screening of Metal–Organic Frameworks for CO 2 Capture in the Presence of Water

Competitive co-adsorption of water is a major problem in the deployment of adsorption-based CO 2 capture. Water molecules may compete for adsorption sites, reducing the capacity of the material, and dehumidification prior to separating CO 2 from N 2 increases process complexity and cost. The development of adsorbent materials that can selectively adsorb CO 2 in the presence of water would be a major step forward in the deployment of CO2 capture materials in practice. In this study, large-scale computational screening was carried out to search for metal-organic frameworks (MOFs) with high selectivity toward CO 2 over H 2 O. Calculating framework charges for thousands of MOFs is a significant challenge, so initial screening used a fast, but approximate, charge calculation method. Based on the initial screening, 15 MOFs were selected, and Monte Carlo simulations were carried out to compute the adsorption isotherms for these MOFs using more accurate framework charges calculated by density functional theory. Here, a detailed investigation was performed on the effect of using different methods for calculating partial charges, and it was found that electrostatic interactions contribute the majority of the adsorption energy of H 2 O in the selected MOFs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Elucidating the Microscale Behavior and Phase Separation Kinetics of Thermally Responsive Ionic Liquid–Water Mixtures

Thermally responsive ionic liquids (ILs) exhibit liquid-liquid phase separation into a water-rich (WR) and ionic-liquid-rich (ILR) phase when heated above a lower critical solution temperature (LCST). This phase behavior has been leveraged for applications ranging from forward osmosis (FO) desalination, where the IL acts as a draw solute, to refrigeration and dehumidification cycles, where the IL acts as a liquid desiccant. While significant effort has been devoted to characterizing the thermodynamic and thermophysical properties of LCST ILs, their phase separation kinetics have not been investigated. In this work, we describe the macroscale phase separation kinetics (phase separation time) by gleaning insight into the microscale colloidal behavior of aqueous mixtures of four different materials, P 4444 TFA (tetrabutylphosphonium-2,4-trifluoroacetate), P 4444 DMBS (tetrabutylphosphonium-2,4-dimethyl-benzenesulfonate), N 4444 Sal (tetrabutylammonium salicylate), and P 4444 Sal (tetrabutylphosphonium salicylate) as a function of IL concentration at a separation temperature of 70 °C. We report the discontinuous microscale size distributions for each material and correlate their theoretical settling velocities to experimental phase separation times. The results indicate that a simple Stokes' law model can predict the phase separation time within reasonable accuracy. Overall, this work lays the foundation for understanding the micro- to macroscale phase separation behavior and kinetics of LCST ILs for various water-energy applications.

LCST↗

Water Adsorption in Porous Metal-Organic Frameworks and Related Materials

Water adsorption in porous materials is important for many applications such as dehumidification, thermal batteries, and delivery of drinking water in remote areas. In this study, we have identified three criteria for achieving high performing porous materials for water adsorption. These criteria deal with condensation pressure of water in the pores, uptake capacity, and recyclability and water stability of the material. In search of an excellently performing porous material, we have studied and compared the water adsorption properties of 23 materials, 20 of which are metal organic frameworks (MOFs). Among the MOFs are 10 zirconium(IV) MOFs with a subset of these, MOF-801-SC (single crystal form), -802, -805, -806, -808, -812, and -841 reported for the first time. MOF-801-P (microcrystalline powder form) was reported earlier and studied here for its water adsorption properties. MOF-812 was only made and structurally characterized but not examined for water adsorption because it is a byproduct of MOF-841 synthesis. All the new zirconium MOFs are made from the Zr6O4(OH)(4)(-CO2)(n) secondary building units (n = 6, 8, 10, or 12) and variously shaped carboxyl organic linkers to make extended porous frameworks. The permanent porosity of all 23 materials was confirmed and their water adsorption measured to reveal that MOF-801-P and MOF-841 are the highest performers based on the three criteria stated above; they are water stable, do not lose capacity after five adsorption/desorption cycles, and are easily regenerated at room temperature. An X-ray single-crystal study and a powder neutron diffraction study reveal the position of the water adsorption sites in MOF-801 and highlight the importance of the intermolecular interaction between adsorbed water molecules within the pores.

Furukawa, H↗

Jumping-Droplet-Enhanced Condensation on Scalable Superhydrophobic Nanostructured Surfaces

When droplets coalesce on a superhydrophobic nanostructured surface, the resulting droplet can jump from the surface due to the release of excess surface energy. If designed properly, these superhydrophobic nanostructured surfaces can not only allow for easy droplet removal at micrometric length scales during condensation but also promise to enhance heat transfer performance. However, the rationale for the design of an ideal nanostructured surface as well as heat transfer experiments demonstrating the advantage of this jumping behavior are lacking. Here, we show that silanized copper oxide surfaces created via a simple fabrication method can achieve highly efficient jumping-droplet condensation heat transfer. We experimentally demonstrated a 25% higher overall heat flux and 30% higher condensation heat transfer coefficient compared to state-of-the-art hydrophobic condensing surfaces at low supersaturations (<1.12). This work not only shows significant condensation heat transfer enhancement but also promises a low cost and scalable approach to increase efficiency for applications such as atmospheric water harvesting and dehumidification. Furthermore, the results offer insights and an avenue to achieve high flux superhydrophobic condensation.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Facility Energy Decision System (FEDS) version 7.0

Designed for building energy managers, utilities and firms providing energy services, FEDS provides a comprehensive and user-friendly method for users to quickly and accurately identifying energy conversion and end-use technology improvements that offer maximum savings in energy usage and cost. FEDS enables the user to assess energy efficiency and consumption, identify retrofit opportunities, select minimum life cycle costs, determine payback, and prioritize investments in energy efficiency retrofit projects for multiple or single buildings across a particular site. As part of the life-cycle cost optimization it also considers several options for partial or complete abandonment of central energy plants including: individual technologies dropping off a thermal loop, a loop and all technologies dropping off a central plant, and all technologies and loops dropping off a central plant resulting in its complete abandonment. Improvements in release 7.0 include: FEDS 7.0 is now a full hourly simulation model (runs every hour of the year as opposed to the previous simplified hourly approach which ran 9 24-hour periods to represent each month). Enhanced building operation and occupancy modeling; New HVAC technology options (VAV, Economizers, Demand Controlled Ventilation, Terminal Reheat, Subcool Dehumidification); Additional chiller types; New lighting technologies (LED, Halogen, Induction, additional fluorescent options); Completely updated retrofit cost and performance data; Regional cost data tied to zip code (previously applied state level averages); Updated and enhanced reporting capabilities; and New pier floor model

Dirks, James↗

Energy-saving technologies for building heating, ventilation, and air conditioning systems

Buildings are responsible for about 38-quadrillion BTU of the total energy in the U.S. at present. The energy demands from buildings keep increasing remarkably to meet the improving life level and the needs of occupants' thermal comfort in the future. Therefore, the developments of high-performance building and efficient building energy systems are highly needed to address the challenges of the climate changes and energy depletion. In this paper, we provide a critical review of the studies on energy-saving technologies for building heating, ventilation, and air conditioning (HVAC) systems. We start with the heat recovery technologies applied to HVAC systems. We continue with the reviews on energy-efficient technologies in heating, cooling, and air dehumidification. After a brief background, we focus on the aspects of those systems: advanced materials, component and system design, and system performance. We highlight the recently emergent design, modeling, and experimental research on those technologies and provide the suggestions and outlook for future research and development of energy-efficient building HVAC systems.

Qu, Ming↗

Subtask 5.3 - Water and Energy Sustainability and Technology

The overall goal of this Energy & Environmental Research Center project was to evaluate water capture technologies in a carbon capture and sequestration system and perform a complete systems analysis of the process to determine potential water minimization opportunities within the entire system. To achieve that goal, a pilot-scale liquid desiccant dehumidification system (LDDS) was fabricated and tested in conjunction with a coal-fired combustion test furnace outfitted with CO{sub 2} mitigation technologies, including the options of oxy-fired operation and postcombustion CO{sub 2} capture using an amine scrubber. The process gas stream for these tests was a coal-derived flue gas that had undergone conventional pollutant control (particulates, SO{sub 2}) and CO{sub 2} capture with an amine-based scrubber. The water balance data from the pilot-scale tests show that the packed-bed absorber design was very effective at capturing moisture down to levels that approach equilibrium conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

MICRO-CHP System for Residential Applications

This is the final report of progress under Phase I of a project to develop and commercialize a micro-CHP system for residential applications that provides electrical power, heating, and cooling for the home. This is the first phase of a three-phase effort in which the residential micro-CHP system will be designed (Phase I), developed and tested in the laboratory (Phase II); and further developed and field tested (Phase III). The project team consists of Advanced Mechanical Technology, Inc. (AMTI), responsible for system design and integration; Marathon Engine Systems, Inc. (MES), responsible for design of the engine-generator subsystem; AO Smith, responsible for design of the thermal storage and water heating subsystems; Trane, a business of American Standard Companies, responsible for design of the HVAC subsystem; and AirXchange, Inc., responsible for design of the mechanical ventilation and dehumidification subsystem.

25 ENERGY STORAGE↗

American Recovery and Reinvestment Act (ARRA) FEMP Technical Assistance - United States Pacific Command (PACOM) Guam, Task 3.3: Building Retuning Training

Document describes an onsite workshop and building retuning training conducted in Guam in August 2010. Document reports on issues identified during an audit of several buildings and recommendations to save energy throughout the site. During the workshop, it became apparent that as site personnel maintain the facilities at Guam, the following retuning efforts and strategies should be prioritized: (1) Controlling the mechanical systems operational hours and zone temperature set points appeared to present the best opportunities for savings; (2) Zone temperature set points in some buildings are excessively low, especially at night, when the zone temperatures are so cold that they approached the dewpoint; and (3) Manually-set outside air dampers are providing excessive outside air, especially for spaces that are unoccupied. Two of the larger schools, one on the Naval Base and one on Anderson AFB, are in need of a significant recommissioning effort. These facilities are relatively new, with direct digital controls (DDC) but are significantly out of balance. The pressure in one school is extremely negative, which is pulling humid air through the facility each time a door is opened. The draft can be felt several feet down the halls. The pressure in the other school is extremely positive relative to the outside, and you can stand 20-feet outside and still feel cool drafts of air exiting the building. It is recommended that humidity sensors be installed in all new projects and retrofitted into exist facilities. In this humid climate, control of humidity is very important. There are significant periods of time when the mechanical systems in many buildings can be unloaded and dehumidification is not required. The use of CO{sub 2} sensors should also be considered in representative areas. CO{sub 2} sensors determine whether spaces are occupied so that fresh air is only brought into the space when needed. By reducing the amount of outside air brought into the space, the humidity load is also substantially reduced. CO{sub 2} and humidity sensors, combined with outside air sensors, can be used to predict whether conditions are amenable to mold growth and to automatically adjust systems to help prevent mold without using extra energy. The goal of this training is to give the building operators the knowledge needed to make positive changes in the operation of building systems. As class participants apply this knowledge, building systems will run more efficiently, occupant comfort should improve, while saving energy and reducing greenhouse gas emissions.

54 ENVIRONMENTAL SCIENCES↗

Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes

The topic of this Building America expert meeting was 'Recommended Approaches to Humidity Control in High Performance Homes,' which was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Moisture performance of sealed attics in the mixed-humid climate

Oak Ridge National Laboratory studied 8 homes in the mixed-humid climate, 4 with vented attics and 4 with sealed attics. ORNL wanted to understand the moisture performance of the sealed attic and how it affected the interior environment. We found that the attic and interior of sealed attic homes were more humid than the attic and interior observed in vented attic homes. This is due to the lack of ventilation in the sealed attic. Historically attics have been vented to dehumidify the attic and interior of the home. A sealed attic design greatly reduces the venting potential and thus this drying pathway and can cause elevated interior moisture over a vented attic home. Despite the elevated attic and interior moisture in the sealed attic homes, so far no mold or material degradation has been found. The roof sheathing moisture content has stayed below 20%, indicating low potential for material degradation. Also the relative humidity at the roof sheathing has stayed within the ASHRAE 160 design criteria except for a short time during the 2011/2012 winter. This was due to a combination of the sealed attic design (minimal venting to the outside) and the duct work not being operated in the attic which usually provides a dehumidification pathway. It was also found that when the humidity was controlled using the HVAC system, it resulted in 7% more cooling energy consumption. In the mixed-humid climate this reduces the cost effectiveness of the sealed attic design as a solution for bringing ducts into a semi-conditioned space. Because of this we are recommending the other alternatives be used to bringing ducts into the conditioned space in both new construction and retrofit work in the mixed-humid climate.

54 ENVIRONMENTAL SCIENCES↗

Measured Performance of Residential Dehumidifiers Under Cyclic Operation

Residential construction practices are progressing toward higher levels of energy efficiency. A proven strategy to save energy is to simultaneously increase building insulation levels and reduce outdoor air infiltration. Tight homes require intentional mechanical ventilation to ensure healthy indoor air. Overall, this strategy results in a shift in the mix of latent and sensible space conditioning loads, requiring proportionally more moisture to be removed compared to standard homes. There is currently not sufficient information available at a wide enough range of operating points to design dehumidification systems for high performance homes in hot-humid climates. The only industry information available on dehumidifier moisture removal and energy consumption are performance ratings conducted at a single test condition, which does not provide a full representation of dehumidifier operation under real-world conditions. Winkler et al. (2011) developed steady state performance maps to predict dehumidifier performance at a variety of indoor conditions. However, installed heating, ventilating, and air-conditioning (HVAC) equipment rarely operates at steady state. Part load performance testing of residential dehumidifiers is not mandated by current test standards. Therefore, we tested the part load performance of four residential dehumidifiers in the National Renewable Energy Laboratory's (NREL) Advanced HVAC Systems Laboratory . The part load efficiency of each dehumidifier was measured under 13 cycling scenarios, and combined with NREL field data to develop part load fraction (PLF) performance curves under realistic cycling scenarios.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

RM12-2703 Advanced Rooftop Unit Control Retrofit Kit Field Demonstration: Hawaii and Guam Energy Improvement Technology Demonstration Project

As part of its overall strategy to meet its energy goals, the Naval Facilities Engineering Command (NAVFAC) partnered with U.S. Department of Energy's (DOE) National Renewable Energy Laboratory (NREL) to rapidly demonstrate and deploy cost-effective renewable energy and energy efficiency technologies. This was one of several demonstrations of new and underutilized commercial energy efficiency technologies. The consistent year-round demand for air conditioning and dehumidification in Hawaii provides an advantageous demonstration location for advanced rooftop control (ARC) retrofit kits to packaged rooftop units (RTUs). This report summarizes the field demonstration of ARCs installed on nine RTUs serving a 70,000-ft 2 exchange store (large retail) and two RTUs, each serving small office buildings located on Joint Base Pearl Harbor-Hickam (JBPHH).

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Variable Speed Heat Pump Sizing Guide for Mixed-Humid Climates

The similarities and differences between different capacity units in a model family will vary depending on the manufacturer. These unit specific details are critical to choosing the VSHP capacity that will yield the highest energy savings without compromising comfort. In addition, the house construction, climate, and occupant behavior will influence the balance of the heating and cooling load on the house as well as the sensible and latent cooling demand. All of these factors need to be considered when trying to select the proper unit for the highest energy savings. Based on the simulations performed in this study, it is likely that VSHPs with an enhanced dehumidification mode can be sized up to two times the cooling load of the house without any reduction in comfort when compared to a single speed heat pump assuming a typical home and occupant behavior in the mixed-humid and cold climates.

42 ENGINEERING↗

Expert Meeting: Recommended Approaches to Humidity Control in High Performance Homes

This meeting was held on October 16, 2012, in Westford, MA, and brought together experts in the field of residential humidity control to address modeling issues for dehumidification. The presentations and discussions centered on computer simulation and field experience with these systems, with the goal of developing foundational information to support the development of a Building America Measure Guideline on this topic.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Heat pump concepts for nZEB Technology developments, design tools and testing of heat pump systems for nZEB in the USA: Country report IEA HPT Annex 40 Task 2, Task 3 and Task 4 of the USA

The IEA HPT Annex 40 "Heat pump concepts for Nearly Zero Energy Buildings" deals with the application of heat pumps as a core component of the HVAC system for Nearly or Net Zero energy buildings (nZEB). This report covers Task 2 on the system comparison and optimisation and Task 3 dedicated to the development of adapted technologies for nZEB and field monitoring results of heat pump systems in nZEB. In the US team three institutions are involved and have worked on the following projects: The Oak Ridge National Laboratory (ORNL) will summarize development activities through the field demonstration stage for several integrated heat pump (IHP) systems electric ground-source (GS-IHP) and air-source (AS-IHP) versions and an engine driven AS-IHP version. The first commercial GS-IHP product was just introduced to the market in December 2012. This work is a contribution to Task 3 of the Annex. The University of Maryland will contribute a software development project to Task 2 of the Annex. The software ThermCom evaluates occupied space thermal comfort conditions accounting for all radiative and convective heat transfer effects as well as local air properties. The National Institute of Standards and Technology (NIST) is working on a field study effort on the NIST Net Zero Energy Residential Test Facility (NZERTF). This residential building was constructed on the NIST campus and officially opened in summer 2013. During the first year, between July 2013 and June 2014, baseline performance of the NZERTF was monitored under a simulated occupancy protocol. The house was equipped with an air-to-air heat pump which included a dedicated dehumidification operating mode. Outdoor conditions, internal loads and modes of heat pump operation were monitored. Field study results with respect to heat pump operation will be reported and recommendations on heat pump optimization for a net zero energy building will be provided. This work is a contribution to Task 3 of the Annex.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Human Health Science Building Geothermal Heat Pump Systems

The grant objectives of the DOE grant funded project have been successfully completed. The Human Health Building (HHB) was constructed and opened for occupancy for the Fall 2012 semester of Oakland University. As with any large construction project, some issues arose which all were overcome to deliver the project on budget and on time. The facility design is a geothermal / solar-thermal hybrid building utilizing both desiccant dehumidification and variable refrigerant flow heat pumps. It is a cooling dominant building with a 400 ton cooling design day load, and 150 ton heating load on a design day. A 256 vertical borehole (320 ft depth) ground source heat pump array is located south of the building under the existing parking lot. The temperature swing and performance over 2013 through 2015 shows the ground loop is well sized, and may even have excess capacity for a future building to the north (planned lab facility). The HHB achieve a US Green Building Counsel LEED Platinum rating by collecting 52 of the total 69 available LEED points for the New Construction v.2 scoring checklist. Being Oakland's first geothermal project, we were very pleased with the building outcome and performance with the energy consumption approximately 1/2 of the campus average facility, on a square foot basis.

15 GEOTHERMAL ENERGY↗