Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Data centers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Italy INAF Data Center Report

This report summarizes the activities of the Italian INAF VLBI Data Center. Our Data Center is located in Bologna, Italy and belongs to the Institute of Radioastronomy, which is part of the National Institute of Astrophysics.

Negusini, M.↗

Finalizing Transition to the New Data Center at BNL

Computational science, data management and analysis have been key factors in the success of Brookhaven National Laboratory's scientific programs at the Relativistic Heavy Ion Collider (RHIC), the National Synchrotron Light Source (NSLS-II), the Center for Functional Nanomaterials (CFN), and in biological, atmospheric, and energy systems science, Lattice Quantum Chromodynamics (LQCD) and Materials Science, as well as our participation in international research collaborations, such as the ATLAS Experiment at Europe's Large Hadron Collider (LHC) at CERN (Switzerland) and the Belle II Experiment at KEK (Japan). The construction of a new data center is an acknowledgement of the increasing demand for computing and storage services at BNL in the near term and enable the Lab to address the needs of the future experiments at the High-Luminosity LHC at CERN and the Electron-Ion Collider (EIC) at BNL in the long term. The Computing Facility Revitalization (CFR) project is aimed at repurposing the former National Synchrotron Light Source (NSLS-I) building as the new data center for BNL. The construction of the new data center was finished in 2021Q3, and it was delivered for production in early FY2022 for all collaborations supported by the Scientific Data and Computing Center (SDCC), including STAR, PHENIX and sPHENIX experiments at RHIC collider at BNL, the Belle II Experiment at KEK (Japan), and the Computational Science Initiative at BNL (CSI). This paper highlights the key mechanical, electrical, and networking components of the new data center in its final configuration as used in production since 2021Q4 and gives an overview for the extension of the central network systems into the new data center and the migration of a significant portion of IT load and services from the old data center to the new data center carried out in 20212023, with expected completion of the main phase of the gradual IT equipment replacement and migration from the old data center into the new one set to the end of FY2023 (Sep 30, 2023).

99 GENERAL AND MISCELLANEOUS↗

Modeling of Microgrid for Critical Data Center Applications

As part of continuing efforts to develop support, understanding, and infrastructure of data center integration onto the electric grid, our work aims to model and analyze the behavior of data center loads in a microgrid power system. Our model consists of renewable energy sources, batteries, and a nuclear reactor-steam Rankine cycle to power data center loads. The simulation studies investigate the electrical behavior of the microgrid system to assess its ability in supporting large data center electrical demands.

14 - SOLAR ENERGY↗

Routing-as-a-Service (RaaS): A Framework for Tenant-Directed Route Control in Data Center

In a multi-tenant data center environment, the current paradigm for route control customization involves a labor-intensive ticketing process where tenants submit route control requests to the landlord. This results in tight coupling between tenants and the landlord, extensive human resource deployment, and long ticket resolution time. We propose Routing-as-a-Service (RaaS), a framework for tenant-directed route control in data centers. Here, we show that RaaS-based implementation provides a route control platform where multiple tenants can perform route control independently with little administrative involvement, and the landlord can set the overall network policies. RaaS-based solutions can run on commercial off-the-shelf (COTS) hardware and leverage existing technologies, so it can be implemented in existing networks without major infrastructural overhaul. We present the design of RaaS, introduce its components, and evaluate a prototype based on RaaS.

97 MATHEMATICS AND COMPUTING↗

Synergistic Pathways for Water Security in Emerging Sectors: Data Centers and Modern Nuclear Facilities

Stand-alone data centers, nuclear-powered data centers, and novel nuclear facilities such as fusion plant and small modular reactors (SMRs) are rapidly expanding, water-intensive sectors that present a significant challenge to the water-for-energy nexus. Their large-scale consumption of water for cooling systems not only reduces downstream water quantity but also degrades quality, demanding an integrated approach by stakeholders to understand and address these impacts through infrastructure planning and development.

42 ENGINEERING↗

Measurement Adequacy for Monitoring Data Center Oscillations

Artificial intelligence (AI) training data centers with periodic load profiles can induce sustained grid oscillations across a wide frequency range, making accurate monitoring essential for reliable power system operation. This report evaluates the adequacy of existing measurement systems for monitoring such oscillations, focusing on phasor measurement units (PMUs) and point-on-wave (POW) measurement systems. The analysis shows that while PMUs are highly effective for monitoring low-frequency electromechanical oscillations, they have inherent limitations in accurately representing higher-frequency oscillations due to constraints imposed by reporting rates and the bandwidth of phasor estimation filters. Even when configured with higher reporting rates, the filtering inherent in the phasor estimation process can significantly attenuate oscillation magnitudes, potentially leading to underestimation of oscillatory behavior. This has important implications for compliance and performance monitoring of large loads. To address the limitations associated with PMU-based monitoring, the report examines the use of high-resolution POW measurements, which can capture oscillations across a broader frequency range. However, continuous POW monitoring introduces practical challenges related to large data volumes, communication bandwidth, and real-time data processing. For this reason, the report also discusses emerging approaches that use POW measurements as a complementary capability alongside PMUs to improve observability of oscillations from large data center loads.

47 OTHER INSTRUMENTATION↗

Storing Affordability: Battery Storage as an Asset to Reduce Data Center Cost Shifts

This report examines how battery energy storage systems (BESS) can help utilities accommodate large load growth while protecting affordability for existing ratepayers. Rapid growth in electricity demand from artificial intelligence (AI) data centers is straining the U.S. grid. Furthermore, many new data centers are entering rural markets, which could offer economic benefits but may also pose implementation challenges for smaller utilities. At the same time, retail electricity prices are increasing faster than inflation, elevating customer affordability as a key challenge. While data centers have not been the primary driver of increases in residential prices to date, they have pushed wholesale energy and capacity prices higher in several markets. Fundamental utility cost-allocation principles show that data center growth can be rate-positive for existing customers only if new peak demand grows faster than the costs a utility must incur to serve it. Several factors, including a utility’s degree of wholesale market exposure, forecast uncertainty and stranded-asset risk, and tariff design can determine the outcome of load growth on retail rates. Energy storage can make several affordability contributions in the face of this landscape of uncertainty and market volatility, including deferral of higher-cost grid investments through improved utilization of existing assets and flexibility of new large loads, insulation from volatile wholesale prices through peak shaving, and reliability support to address grid risks stemming from the behavior of AI data center loads. Different potential BESS deployment pathways—utility-scale front-of-the-meter systems, aggregated small-scale storage installations, and data center-sited behind-the-meter storage—are compared against each other and against conventional capacity alternatives. This framework is intended as a conceptual resource to utilities, particularly smaller public utilities with rural service territories, who may be considering the role that energy storage can play in insulating existing ratepayers from data center cost shifts.

25 ENERGY STORAGE↗

Electromagnetic Transient Modeling of Data Centers

This report serves as a user manual for the accompanying EMT model library developed by the National Laboratory of the Rockies (NLR) for various equipment in large data centers. The EMT model library enables detailed modeling of large data center loads for conducting grid stability studies. The EMT model library for data centers include detailed models of a 5.5 kW power supply unit (PSU), a 2.5 uninterruptible power supply (UPS), a 260 MW gas turbine-generator, a 500 kW motor load, and a 33 kW IT rack. These components represent all major equipment in data centers that need to be modeled for performing grid stability studies for data centers.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Particle concentrations in data centers

Cooling buildings with large airflow rates of outside air when temperatures are favorable is an established energy-saving measure. In data centers, this strategy is not widely used, owing to concerns that it would cause increased indoor levels of particles of outdoor origin, which could damage electronic equipment. However, environmental conditions typical of data centers and the associated potential for equipment failure are not well characterized. Here we present the first published measurements of particle concentrations in operating data centers. Indoor and outdoor particle measurements were taken at eight different sites in northern California for particulate matter 0.3–5.0 μm in diameter. One of the data centers has an energy-efficient design that employs outside air for cooling, while the rest use conventional cooling methods. Ratios of measured particle concentrations in the conventional data centers to the corresponding outside concentrations were significantly lower than those typically found in office or residential buildings. Estimates using a material-balance model match well with empirical results, indicating that the dominant particle sources and losses have been identified. Measurements taken at the more energy-efficient site show nearly an order of magnitude increase in particle concentration when ventilation rates were high. The model indicates that this increase may be even higher when including particles smaller than the monitoring-equipment size limitation. Even with the increases, the measured particle concentrations are still below concentration limits recommended in industry standards.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Data Center Loads for a Large-Scale, Net Zero Office Building

In constructing a new research facility for its campus, the National Renewable Energy Laboratory (NREL) project team identified the opportunity to design a world-class, energy-efficient data center to support its operations. NREL’s efforts resulted in a highly efficient data center that demonstrated considerable energy savings in its first 11 months of operations. Using legacy data center performance as a baseline, the new facility cut energy use by nearly 1,450,000 kWh, delivering cost savings of approximately $82,000. The data center’s average total load was 165 kW less than the legacy center’s average total load, resulting in a 60% reduction in overall power. Finally, the limited use of cooling and fan energy enabled the new data center to achieve a 1.16 average power utilization effectiveness (PUE) rating, compared to the legacy data center’s PUE of 2.28.

Reducing, Data, Large-Scale, Net-Zero, Office, Bui↗

Equation-based object-oriented modeling and simulation for data center cooling: A case study

© 2019 Elsevier B.V. Data center cooling accounts for about 1% of electricity usage in the United States. Computer models are pivotal in designing and operating energy-efficient cooling systems. Compared to conventional building performance simulation programs, the equation-based object-oriented modeling language Modelica is an emerging approach that can enable fast prototyping and dynamic simulation of cooling systems. In this case study, we first modeled the cooling and control systems of an actual data center located in Massachusetts using the open-source Modelica Buildings library, and then calibrated a baseline model based on measurement data. The simulation of the baseline model identified several operation-related issues in the cooling and control systems, such as degraded cooling coils, improper dead band in control settings, and simultaneous cooling and heating in air handlers. Afterwards, we used a sequential search technique as well as an optimization scheme to investigate the energy saving potentials for different energy efficiency measures aiming to address the abovementioned issues. Simulation results show potential energy savings up to 24% by resolving identified control-related issues and optimizing the supply air temperature.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Reducing Data Center Peak Cooling Demand and Energy Costs with Underground Thermal Energy Storage (UTES)

By recent estimates, data center energy demands are projected to consume between 6.7% and 12% of U.S. annual electricity generation by the year 2028, driven primarily by expanded demands from cloud services, big data analytics, and Artificial Intelligence (AI) (Shehabi et al., 2024). As much as 40% of data center total energy consumption are loads associated with the site infrastructure cooling systems, and these are often highly water consumptive (Aljbour et al., 2024). For energy system planners, this presents significant challenges to meeting and managing the anticipated loads, and especially the peak loads of projected data center deployments. Geothermal technologies offer two unique solutions to these challenges: 1) by serving loads through the deployment of new conventional and/or next-generation geothermal power technologies such as EGS and 2) through an often-overlooked opportunity to reduce data center peak cooling loads. The latter is the focus of this paper which explores Cold Underground Thermal Energy Storage ("Cold UTES") as an emerging industrial-scale geothermal cooling solution. This cooling solution is energy efficient, non-water-consumptive, and utilizes long duration energy storage (LDES) on both diurnal and seasonal time scales. Cold UTES has the potential to also function as a virtual power plant (VPP). The US Department of Energy's Geothermal Technologies Office is supporting R&D to understand the grid and system-wide value, costs, and impacts of deploying this emergent cooling solution at scale.

AI↗

Mechanistic modeling of copper corrosions in data center environments

Air-side economizers are increasingly used to take advantage of “free-cooling” in data centers with the intent of reducing the carbon footprint of buildings. However, they can introduce outdoor pollutants to indoor environment of data centers and cause corrosion damage to the information technology equipment. Here, to evaluate the reliability of information technology equipment under various thermal and air-pollution conditions, a mechanistic model based on multi-ion transport and chemical reactions was developed. The model was used to predict Cu corrosion caused by Cl2-containing pollutant mixtures. It also accounted for the effects of temperature (25 °C and 28 °C), relative humidity (50%, 75%, and 95%), and synergism. It also identified higher air temperature as a corrosion barrier and higher relative humidity as a corrosion accelerator, which agreed well with the experimental results. The average root mean square error of the prediction was 13.7 Å. The model can be used to evaluate the thermal guideline for data centers design and operation when Cl2 is present based on pre-established acceptable risk of corrosion in data centers’ environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

The Backgrounds Data Center

The Strategic Defense Initiative Organization has created data centers for midcourse, plumes, and backgrounds phenomenologies. The Backgrounds Data Center (BDC) has been designated as the prime archive for data collected by SDIO programs. The BDC maintains a Summary Catalog that contains 'metadata,' that is, information about data, such as when the data were obtained, what the spectral range of the data is, and what region of the Earth or sky was observed. Queries to this catalog result in a listing of all data sets (from all experiments in the Summary Catalog) that satisfy the specified criteria. Thus, the user can identify different experiments that made similar observations and order them from the BDC for analysis. On-site users can use the Science Analysis Facility (SAFE for this purpose. For some programs, the BDC maintains a Program Catalog, which can classify data in as many ways as desired (rather than just by position, time, and spectral range as in the Summary Catalog). For example, data sets could be tagged with such diverse parameters as solar illumination angle, signal level, or the value of a particular spectral ratio, as long as these quantities can be read from the digital record or calculated from it by the ingest program. All unclassified catalogs and unclassified data will be remotely accessible.

Snyder, W. A.↗

Establishing a Secure Data Center with Remote Access: Preprint

Access to existing travel data is critical for many analysis efforts that lack the time or resources to support detailed data collection. High-resolution data sets provide particular value, but also present a challenge for preserving the anonymity of the original survey participants. To address this dilemma of providing data access while preserving privacy, the National Renewable EnergyLaboratory and the U.S. Department of Transportation have launched the Transportation Secure Data Center (TSDC). TSDC data sets include those from regional travel surveys and studies that increasingly use global positioning system devices. Data provided by different collecting agencies varies with respect to formatting, elements included and level of processing conducted in support of theoriginal purpose. The TSDC relies on a number of geospatial and other analysis tools to ensure data quality and to generate useful information outputs. TSDC users can access the processed data in two different ways. The first is by downloading summary results and second-by-second vehicle speed profiles (with latitude/longitude information removed) from a publicly-accessible website. The secondmethod involves applying for a remote connection account to a controlled-access environment where spatial analysis can be conducted, but raw data cannot be removed. The TSDC website is http://www.nrel.gov/vehiclesandfuels/secure_transportation_data.html.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Alternative Fuels Data Center

Fact sheet describes the Alternative Fuels Data Center, which provides information, data, and tools to help fleets and other transportation decision makers find ways to reduce petroleum consumption through the use of alternative and renewable fuels, advanced vehicles, and other fuel-saving measures.

AFDC↗