Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Source Diagnostic Fan II (22-Inch) Duct Mode Characteristics as Measured by the Rotating Rake Mode Measurement System while Operated in the NASA Glenn 9x15 Low Speed Wind Tunnel

A 22-inch scale model of the Honeywell Quiet High Speed Fan II was tested in the NASA Glenn 9- by 15-foot Low Speed Wind Tunnel at a tunnel Mach number of 0.10. This was an entry to investigate the effect of “stator clocking” on noise. The fan consisted of a moderately aft swept rotor, and an aft swept set of stator vanes. The fan stage consisted of 22 rotor blades, 50 stator vanes, and 10 downstream support struts. A set of stator vanes designed for lower noise was tested as well as a baseline stator vane set. The stator assembly could be rotated several degrees to adjust the clocking angle between the stator vane pack and the strut assembly. All configurations were with a hard wall duct (no acoustic treatment). The NASA Glenn Research Center’s Rotating Rake Mode Measurement System was utilized to obtain a complete map of the acoustic duct modes present in the ducted fan. The system is a radial rake emersed into the duct that continuously rotates about the duct centerline. For the two stator configurations, data were acquired at several different fan speeds which included nominal, approach, cutback, and takeoff conditions. Analysis of the mode power level results at the fan fundamentals showed the improved designed set resulted in lower rotor-stator and rotor-strut interaction acoustic levels for the interaction modes. Varying the angle between the stators and struts was shown to be a viable method to achieve a minimum in rotor-strut interaction mode power level. Multiple-pure-tones generated by the Quiet High Speed Fan II in the inlet were also measured.

Fan Noise↗

Technology Solutions Case Study: Duct in Conditioned Space in a Dropped Ceiling or Fur-down, Gainesville, Florida

Forced-air distribution systems (duct systems) typically are installed out of sight for aesthetic reasons, most often in unconditioned areas such as attics or crawlspaces. Any leakage of air to or from the duct system in unconditioned space not only loses energy, but impacts home and equipment durability and indoor air quality. An obvious solution is to bring the duct system into the interior of the house, either by sealing the area where the ducts are installed (attic or crawlspace) or by building an interior cavity or chase above the ceiling plane (raised ceiling or fur-up chase) or below the ceiling plane (dropped ceiling or fur-down) for the duct system. In this project, Building America Partnership for Improved Residential Construction team partnered with Tommy Williams Homes to implement an inexpensive, quick, and effective method of building a fur-down chase.

BA-PIRC↗

Are Ducted Mini-Splits Worth It?

Ducted mini-split heat pumps are gaining popularity in some regions of the country due to their energy-efficient specifications and their ability to be hidden from sight. Although product and install costs are typically higher than the ductless mini-split heat pumps, this technology is well worth the premium for some homeowners who do not like to see an indoor unit in their living area. Due to the interest in this technology by local utilities and homeowners, the Bonneville Power Administration (BPA) has funded the Pacific Northwest National Laboratory (PNNL) and the National Renewable Energy Laboratory (NREL) to develop capabilities within the Building Energy Optimization (BEopt) tool to model ducted mini-split heat pumps. After the fundamental capabilities were added, energy-use results could be compared to other technologies that were already in BEopt, such as zonal electric resistance heat, central air source heat pumps, and ductless mini-split heat pumps. Each of these technologies was then compared using five prototype configurations in three different BPA heating zones to determine how the ducted mini-split technology would perform under different scenarios. The result of this project was a set of EnergyPlus models representing the various prototype configurations in each climate zone. Overall, the ducted mini-split heat pumps saved about 33-60% compared to zonal electric resistance heat (with window AC systems modeled in the summer). The results also showed that the ducted mini-split systems used about 4% more energy than the ductless mini-split systems, which saved about 37-64% compared to electric zonal heat (depending on the prototype and climate).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Duct Insulation and Sealing Requirements in Commercial Buildings - Code Notes

Duct insulation and sealing, especially insulated supply ducts delivering conditioned air within a building, save energy. The intent of energy-efficiency codes, as related to duct insulation and sealing, is to keep mechanically warmed or cooled air as close to a constant, desired temperature as possible and prevent the conditioned air from escaping the duct system while it is being moved to spaces where it is needed. If reduced heat transfer through insulated ducts is accounted for in the heating, ventilating, and air conditioning (HVAC) load calculations, it may even be possible to reduce the size of HVAC equipment.

Duct systems, thermal envelope, conditioned air, H↗

Technology Solutions Case Study: Ducts Sealing Using Injected Spray Sealant

In multifamily and attached buildings, traditional duct sealing methods are often impractical or costly and disruptive because of the difficulty in accessing leakage sites. In this project, the Raleigh Housing Authority worked with Building America team, the Advanced Residential Integrated Solutions Collaborative to determine the most cost-effective ways to reduce duct leakage in its low-rise housing units.Two retrofit duct sealing techniques—manually-applied sealants and injecting a spray sealant—were implemented in several low-rise multiunit buildings. An analysis on the cost and performance of the two methods are presented. Each method was used in twenty housing units: approximately half of each group of units are single story and the remainder two-story. Results show that duct leakage to the outside was reduced by an average of 59% through the use of manual methods, and by 90% in the units where the injected spray sealant was used. Ihe cost of manually-applying sealant ranged from $275 to $511 per unit and for the injected spray sealant the cost was $700 per unit. Modeling suggests a simple payback of 2.2 years for manual sealing and 4.7 years for the injected spray sealant system. Utility bills were collected for one year before and after the retrofits. Utility bill analysis shows 14% and 16% energy savings using injected spray sealant system and hand sealing procedure respectively in heating season whereas in cooling season, energy savings using injected spray sealant system and hand sealing were both 16%.

Aeroseal↗

Ducted Fuel Injection vs. Free-Spray Injection: A Study of Mixing and Entrainment Effects Using Numerical Modeling

Diesel engines are an important technology for transportation of both people and goods. However, historically they have suffered a significant downside of high soot and nitrogen oxides (NO x ) emissions. Recently, ducted fuel injection (DFI) has been demonstrated to attenuate soot formation in compression-ignition engines and combustion vessels by 50% to 100%. This allows for diesel engines to be run at low-NO x emissions that would have otherwise produced significantly more soot due to the soot/NO x tradeoff. Currently the root causes of this soot attenuation are not well understood. To be able to better optimize DFI for use across a variety of engines and conditions, it is important to understand clearly how it works. This study expands on the current understanding of DFI by using numerical modeling under nonreacting conditions to provide insights about the roles of entrainment and mixing that would have been much more challenging to obtain experimentally. We report this study found that DFI enhances charge gas entrainment upstream of the duct and blocks entrainment inside of the duct. Mixing is enhanced by the duct, which results in lower peak equivalence ratios at the exit of the duct.

42 ENGINEERING↗

Sound measurements within and in the radiated field of an annular duct with flow.

Recent theory on sound propagation for flow ducts initiated a research program (sponsored by NASA-Langley, Contract NAS1-10472) which has the objective of comparing detailed acoustical measurements with the analytical predictions for sound propagation in a duct with sheared flow. The effects considered experimentally mean flow, shear, wall impedance, and source distribution on sound propagation within and radiation from finite lenght annular ducts. Results reported here are confined to acoustic distribution in hard annular ducts with and without mean flow and radiated field patterns for the same conditions. The acoustic distributions are shown for single and multi-mode excitation. The flow duct facility is also described.

Plumblee, H. E.↗

A 727 airplane center duct inlet low speed performance confirmation model test for refanned JT8D engines, phase 2

The results from testing of a 0.3 scale model center duct inlet (S duct) for the Pratt and Whitney Aircraft JT8D-100 engines are presented. The objective of this test was to demonstrate that the required airflow of the JT8D-100 engine (480 lb/sec as compared to 334 lb/sec for JT8D-15) can be achieved with minimum modifications to the existing 727 airplane structure at acceptable levels of total pressure recovery and distortion. Steady-state pressure recovery, steady-state pressure distortion, and dynamic pressure measurements were taken at the engine face station. Surface static pressure measurements were taken along the duct. Test results indicated that the required airflow was achieved with acceptable pressure recovery (comparable to the current 727-200 S duct). Inlet inflow angle variation within the 727 airplane operating regime (minus 5 to 5 degrees) had no effect on the inlet performance. Pressure distortion at static and forward speed at takeoff airflow conditions are within P and WA limits for the Phase II duct when equipped with vortex generators. Static crosswind operation between 10 knots and 25 knots appears feasible at full takeoff power.

Kaldschmidt, G.↗

Generalized wave envelope analysis of sound propagation in ducts with stepped noise source profiles and variable axial impedance

A finite difference formulation is presented for sound propagation in a rectangular two-dimensional duct without steady flow. Before the difference equations are formulated, the governing Helmholtz equation is first transformed to a form whose solution tends not to oscillate along the length of the duct. This transformation reduces the required number of grid points by an order of magnitude. Example solutions indicate that stepped noise source profiles have much higher attenuation than plane waves in a uniform impedance liner. Also, multiple stepped impedance liners are shown to have higher attenuation than uniform ducts if the impedances are chosen properly. For optimum noise reduction with axial variations in impedance, the numerical analysis indicates that for a plane wave input the resistance should be near zero at the entrance of a suppressor duct, while the reactance should be near the optimum value associated with the least-attenuated mode in a uniform duct.

Baumeister, K. J.↗

The transmission of sound in nonuniform ducts

The method of weighted residuals in the form of a modified Galerkin method with boundary residuals was developed for the study of the transmission of sound in nonuniform ducts carrying a steady, compressible flow. In this development, the steady flow was modeled as essentially one dimensional but with a kinematic modification to force tangency of the flow at the duct walls. Three forms of the computational scheme were developed using for basis functions (1) the no-flow uniform duct modes, (2) positive running uniform duct modes, with flow, and (3) positive and negative running uniform duct modes, with flow. The formulation using the no-flow modes was the most highly developed, and has advantages primarily due to relative computational simplicity. Results using the three methods are shown to converge to known solutions for several special cases, and the most significant check case is against low frequency, one dimensional results over the complete subsonic Mach number range. Development of the method is continuing, with emphasis on assessing the relative accuracy and efficiency of the three implementations.

Eversman, W.↗

Acoustic radiation from lined, unflanged ducts: Acoustic source distribution program

An acoustic radiation analysis was developed to predict the far-field characteristics of fan noise radiated from an acoustically lined unflanged duct. This analysis is comprised of three modular digital computer programs which together provide a capability of accounting for the impedance mismatch at the duct exit plane. Admissible duct configurations include circular or annular, with or without an extended centerbody. This variation in duct configurations provides a capability of modeling inlet and fan duct noise radiation. The computer programs are described in detail.

Beckemeyer, R. J.↗

Design and testing of new center inlet and S-duct for B-727 airplane with refanned JT8D engines

The work described in this paper was part of the NASA refan program. The airflow requirement of the refanned JT8D (-100 series) engine increased about 50% above that of the basic JT8D. This required a redesign of the center inlet and S-duct of the Boeing 727 airplane. The paper describes the design constraints for the S-duct and the analytic method used to define the lines of the new duct. Model tests that were conducted at static, angle-of-attack, and crosswind conditions are described with a variety of flow control devices. Test results showed that the new inlet and S-duct have a pressure recovery comparable to that of the existing inlet. By employing corotating vortex generators, less flow distortion was obtained for the core region than the existing duct has with its counter rotating vortex generators.

Ting, C. T.↗

Wind tunnel blockage tests at Mach 5 of vacuum duct models for two sound radiation shields

Two sound shield models with dummy vacuum exhaust ducts were tested in a Mach 5 pilot quiet tunnel. The first model simulates a new sound shield of 3 in. (7.62 cm) inside diameter and the second model is a shield of 4 in. (10.16 cm) inside diameter. The dummy vacuum exhaust ducts were attached to the external housing of the models. The flow in the first model, which had a by pass mass flow ratio of about 0.6, could not be started except at the two highest test Reynolds numbers where only the central core flow region was started. The flow in the second model with a mass ratio of approximately 0.3 was fully started except at the lowest unit Reynolds number where some unsteadiness and partial flow separation at the wall was observed. Since the external housing and dummy vacuum ducts were the same for both models, these results indicate that the ratio of by pass mass flow to total mass flow for a wind tunnel sound shield of this particular design must be less than about 0.3. Hence, a lower limit is imposed on the inlet diameter of the sound shield in relation to the exit diameter of the wind tunnel nozzle. This lower limit on the inlet diameter may possibly be reduced by improvements in streamlining of the external housing and ducts, by reductions in blockage area, or by the use of external ducting shrouds.

Beckwith, I. E.↗

A multi-modal solution for the transmission of sound in nonuniform ducts

The method of weighted residuals in the form of a modified Galerkin method with boundary residuals is developed for the study of the transmission of sound in nonuniform ducts carrying a steady compressible flow. In this formulation the steady flow is modeled as essentially one-dimensional but with a kinematic modification to force tangency of the flow at the duct walls. Good agreement has been obtained with known results for transmission and reflection coefficients in hard walled ducts up to near sonic velocities. In ducts with acoustically compliant boundaries good comparisons have been more difficult to achieve except at low Mach numbers. The problem of transmission in a straight, acoustically treated duct with a uniform flow has been formulated and the Galerkin method used with basis functions derived from the case when flow is absent. Results indicate that favorable comparisons with exact computations can be obtained if care is taken in choosing the basis functions.

Eversman, W.↗

Transmission of sound through nonuniform circular ducts with compressible mean flows

An acoustic theory is developed to determine the sound transmission and attenuation through an infinite, hard-walled or lined, circular duct carrying compressible, sheared, mean flows and having a variable cross section. The theory is applicable to large as well as small axial variations, as long as the mean flow does not separate. Although the theory is described for circular ducts, it is applicable to other duct configurations - annular, two dimensional, and rectangular. The theory is described for the linear problem, but the technique is general and has the advantage of being applicable to the nonlinear case as well as the linear case. The technique is based on solving for the envelopes of the quasi-parallel acoustic modes that exist in the duct instead of solving for the actual wave. A computer program was developed. The mean flow model consists of a one dimensional flow in the core and a quarter-sine profile in the boundary layer. Results are presented for the reflection and transmission coefficients in ducts with varying slopes and carrying different mean flows.

Nayfeh, A. H.↗

Effect of flow on quasi-one-dimensional acoustic wave propagation in a variable area duct of finite length

The general equation for the velocity potential of quasi-one-dimensional acoustic wave motion in a variable area, finite duct with one-dimensional flow is derived by using a perturbation technique. The nonlinear second-order partial differential equation is linearized and then solved, by either a power series expansion method or the Runge-Kutta fourth-order method, for harmonic time dependence. The boundary condition taken at the duct mouth is that of matching the impedance of the duct sound field to that of the radiation field at the duct opening. Three axial Mach number variations along the duct axis are considered and the results obtained are compared with those for the case of constant Mach number, to determine the influence of the axial velocity gradient on sound propagation. The effect of flow on the radiation impedance is also considered.

Lumsdaine, E.↗

Sound propagation through a subsonic jet due to a source near the duct exit

Matched asymptotic solutions are constructed for the acoustic potentials of a periodic point source located in a two-dimensional subsonic jet near the exit of the duct with the ratio of the duct thickness to the acoustic wave length as the small parameter. The leading term of the far field solution has the same directionality effect as that for an infinite jet without the duct and that when the plane at the duct exit is considered to be a plane of symmetry. However, the intensity is different because of the wave propagation into the duct and is dependent on the location of the source.

Ting, L.↗

Modal propagation angles in a cylindrical duct with flow and their relation to sound radiation

The main emphasis is upon the propagation angle with respect to the duct axis and its relation to the far-field acoustic radiation pattern. When the steady flow Mach number is accounted for in the duct, the propagation angle in the duct is shown to be coincident with the angle of the principal lobe of far-field radiation obtained using the Wiener-Hopf technique. Different Mach numbers are allowed within the duct and in the external field. For static tests with a steady flow in an inlet but with no external Mach number the far-field radiation pattern is shifted considerably toward the inlet axis when compared to zero Mach number radiation theory. As the external Mach number is increased the noise radiation pattern is shifted away from the inlet axis. The theory is developed using approximations for sound propagation in circular ducts. An exact analysis using Hankel function solutions for the zero Mach number case is given to provide a check of the simpler approximate theory.

Rice, E. J.↗