Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DEFAULT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Corrective Action Investigation Plan for Corrective Action Unit 567: Miscellaneous Soil Sites, Nevada National Security Site, Nevada, with ROTC 1 Revision 0

Corrective Action Unit (CAU) 567 is located in Areas 1, 3, 5, 20, and 25 of the Nevada National Security Site, which is approximately 65 miles northwest of Las Vegas, Nevada. CAU 567 is a grouping of sites where there has been a suspected release of contamination associated with nuclear testing. This document describes the planned investigation of CAU 567, which comprises the following corrective action sites (CASs): • 01-23-03, Atmospheric Test Site T-1 • 03-23-25, Seaweed E Contamination Area • 05-23-07, A5b RMA • 20-23-08, Colby Mud Spill • 25-23-23, J-11 Soil RMA These sites are being investigated because existing information on the nature and extent of potential contamination is insufficient to evaluate and recommend corrective action alternatives (CAAs). Additional information will be obtained by conducting a corrective action investigation before evaluating CAAs and selecting the appropriate corrective action for each CAS. The results of the field investigation will support a defensible evaluation of viable CAAs that will be presented in the investigation report. The sites will be investigated based on the data quality objectives (DQOs) developed on May 6, 2013, by representatives of the Nevada Division of Environmental Protection and the U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Field Office. The DQO process was used to identify and define the type, amount, and quality of data needed to develop and evaluate appropriate corrective actions for CAU 567. The site investigation process will also be conducted in accordance with the Soils Activity Quality Assurance Plan, which establishes requirements, technical planning, and general quality practices to be applied to this activity. The potential contamination sources associated with CAU 567 releases are nuclear test operations and other NNSS operations. The DQO process resulted in an assumption that total effective dose (TED) within a default contamination boundary at Atmospheric Test Site T-1 exceeds the final action level (FAL) and requires corrective action. The presence and nature of contamination outside the default contamination boundary at Atmospheric Test Site T-1 and all other CAU 567 CASs will be evaluated based on information collected from a field investigation. Radiological contamination will be evaluated based on a comparison of the TED at sample locations to the dose-based FAL. The TED will be calculated as the total of separate estimates of internal and external dose. Results from the analysis of soil samples will be used to calculate internal radiological dose. Thermoluminescent dosimeters placed at the center of each sample location will be used to measure external radiological dose. Appendix A provides a detailed discussion of the DQO methodology and the DQOs specific to each CAS.

54 ENVIRONMENTAL SCIENCES↗

BPLU Completion and Verification Report

The Border Profile LU (BPLU) linear equation solver is the default solver for newer versions of RELAP5-3D. It can significantly reduce execution time compared to the previous default solver, MA18. Particularly for 3D cases, it can reduce run time by one to two orders of magnitude over MA18. However, because of some user reported failures, the MA18 solver currently must be used for coupled analyses. Over one dozen User Problems (UP) have been reported between 1999 and 2011 that involve the BPLU solver in RELAP5-3D. These issues can be combined into two categories of problems with the solver: • It fails when running multidimensional components with the nearly-implicit hydrodynamics advancement scheme. • It fails with some input models where the MA18 sparse solver does not fail. The sources of these UP have been found and corrected. The modified coding has been thoroughly tested with over 3000 test cases and on two different compute platforms. The updates are incorporated in RELAP5-3D, version 3.0.2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Validating nuclear models: electron data to interpret neutrino physics

Nuclear models in Monte Carlo event generators are crucial for interpreting neutrino scattering experiments, but are dicult to verify using only neutrino data due to incomplete data for some energy ranges. In particular, we seek to constrain the GENIE neutrino event generator's models. To overcome the uncertainties inherent to neutrino experiments, it is useful to take advantage of more controllable electron scattering experiments to evaluate current models and place constraints on future models. In this preliminary study on the feasibility of this strategy, we evaluate variables sensitive to the choice of nuclear model for the GENIE default model and data from the Jeerson Labs CLAS experiment. We nd some disagreement between them, likely explained by the the use of a dated default and background known to be remaining in the CLAS data that is not accounted for.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Data-Driven Understanding of Low-to-Moderate Income Customers’ Adoption and Financial Qualification in Community Solar

Through this project, we sought to gather a body of customer data that either proved or disproved our assumption that metrics other than FICO can and should be used to qualify customers for community solar. Using customer data on income, FICO scores, and utility/rent/cell phone repayment history, we developed an alternative metric in order to test in the market at a small scale whether new qualifying metrics could open the shared solar market up to millions of additional households. We demonstrate that the EnergyScore is both more accurate in qualifying customers that will not default, and more inclusive in qualifying low to moderate income households. We are now in the process of utilizing the EnergyScore in a number of pilot projects, building a robust dataset of customer churn and default, and subsequently disseminating this data to more traditional and larger scale financiers and solar developer partners to change the way potential customers are qualified.

14 SOLAR ENERGY↗

Parameter Sensitivity Analysis of the SparTen High Performance Sparse Tensor Decomposition Software (Extended Analysis)

Tensor decomposition models play an increasingly important role in modern data science applications. One problem of particular interest is fitting a low-rank Canonical Polyadic (CP) tensor decomposition model when the tensor has sparse structure and the tensor elements are nonnegative count data. SparTen is a high-performance C++ library which computes a low-rank decomposition using different solvers: a first-order quasi-Newton or a second-order damped Newton method, along with the appropriate choice of runtime parameters. Since default parameters in SparTen are tuned to experimental results in prior published work on a single real-world dataset conducted using MATLAB implementations of these methods, it remains unclear if the parameter defaults in SparTen are appropriate for general tensor data. Furthermore, it is unknown how sensitive algorithm convergence is to changes in the input parameter values. This report addresses these unresolved issues with large-scale experimentation on three benchmark tensor data sets. Experiments were conducted on several different CPU architectures and replicated with many initial states to establish generalized profiles of algorithm convergence behavior.

97 MATHEMATICS AND COMPUTING↗

Cost Impacts of Risk-Based Methods for Defining AoR and PISC Duration of a CO 2 Storage Project Using NRAP Tools and FE/NETL CO 2 Saline Storage Cost Model

The purpose of this analysis is to assess the fiscal impact of using risk-based methods to define the area of review (AoR) and post-injection site care (PISC) duration for a geologic carbon dioxide (CO 2 ) storage project. The Office of Fossil Energy (FE)/National Energy Technology Laboratory (NETL) CO 2 Saline Storage Cost Model (“cost model”) was utilized to evaluate CO 2 storage economics in this study. The cost model is a widely used tool for evaluating CO 2 storage costs in geologic settings. It estimates costs for storage operations conducted under compliance to the United States Environmental Protection Agency (EPA) Underground Injection Control (UIC) Class VI regulations. This analysis evaluates and compares the costs of storage (on a first-year break-even dollar per tonne [2018$] basis) at the proposed FutureGen 2.0 site as a case study storage location by implementing different approaches to determine AoR and PISC given the prevailing geologic conditions and injection volume and duration considerations. The approaches include the use of 1) risk-based methods to define AoR and PISC duration, 2) an EPA-approved AoR and PISC documented in the FutureGen 2.0 UIC Class VI permit applications, and 3) cost model default settings that utilize uncertainty multipliers to estimate CO 2 plume and pressure front extent as part of AoR determination, as well as a 50-year PISC default. From all three sources, the AoR and PISC specified in the Class VI permit applications for FutureGen 2.0 were the largest and longest relative to the other two sources.

54 ENVIRONMENTAL SCIENCES↗

Building Model Calibration: Validation of GridLAB-D Thermal Dynamics Modeling

This report investigates how well GridLAB-D’s house model characterizes the thermal dynamics of buildings given the overpredicted diurnal electric load swing observed in the Distribution System Operation with Transactive (DSO+T) study. This study seeks to validate GridLAB-D’s house model by calibrating it to data from the well-instrumented Pacific Northwest National Laboratory Lab Homes in Richland, WA. The datasets chosen included multiple pre-cooling and pre-heating testing periods where the indoor air temperature was allowed to float over a multi-hour length of time to mimic diurnal behavior. The multi-season calibrations were evaluated by comparing the heating/cooling electric power, indoor air temperature, and the rise/decay time during temperature float periods with Lab Homes data. The default GridLAB-D assumptions for latent load fraction, air heat capacity, mass heat capacity, window-to-wall-ratio, overall envelope conductance (assumed as NORMAL thermal integrity level), and solar heat gain coefficient were compared with the calibrated model to confirm when the default assumptions were adequate and the impact of calibration on the accuracy of modeling the thermal dynamics of homes.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Validation of New MCNP6.3 Features for Critical and Subcritical Benchmark Simulations [Slides]

A separate MCNP6.3 V&V document reports on all the default calculations for all test suites was introduced. Here, we look at new optional features of the MCNP6.3 code. Then, Fission-matrix-based options with Convergence and population testing and Automated acceleration of the fission source and Doppler Broadening Resonance Correction and HDF5 Particle Track Output (PTRAC) and Validation benchmarks: criticality, Rossi-α, and subcritical multiplication. All the new MCNP6.3 options give statistically equivalent results and should be considered for default usage in criticality and subcritical multiplication calculation work. Discussed are two separate papers at the upcoming 2023 International Conference on Nuclear Criticality Safety (ICNC 2023) that give more details on the results presented here.

97 MATHEMATICS AND COMPUTING↗

MultiPEM Toolbox: User Manual [Rev. 2]

This document explains use of the Multi-Phenomenology Explosion Monitoring (Multi PEM) Toolbox, a collection of R scripts for estimating the unknown device parameters of a new event with uncertainty quantification. The methodology and application used for illustration in this user manual are fully documented in a Los Alamos National Laboratory technical report hereafter designated “WPA” for reference. Additional details on the application are found in a recent journal article. Two assessment types are available: rapid and complete. Rapid assessments are conducted in two stages, as described in Section 2. In the first stage, calibration data are used to estimate forward and error model parameters (WPA, §5.1) and (if relevant) errors-in-variables yield values for calibration sources (WPA, §3, Equation (3)). In the second stage, new event data are used to estimate the unknown new event device parameters (WPA, §5.2) with uncertainty quantification. Two options for treating the inferred first stage parameters in second stage Bayesian analysis are available: fixing them at their maximum likelihood estimate (default), or multiple imputation. Multiple imputation involves utilizing several posterior samples (imputations) of the first stage parameters as fixed values in the second stage posterior sampling of the new event device parameters. Second stage sampling is conducted across imputations in parallel to improve computational efficiency. This method produces improved uncertainty quantification of the new event device parameters compared with the default treatment of the first stage parameters, at the expense of additional computation. Complete assessments are conducted in a single stage, as described in Section 3. Calibration and (if relevant) new event data are used simultaneously to estimate all forward model, error model, and (if relevant) new event device parameters with uncertainty quantification on the latter. As the name suggests, rapid assessments generally run substantially faster than complete assessments (even with multiple imputation), because the results of first stage analysis can be stored and incorporated into estimating a relatively low-dimensional space of new event device parameters whenever relevant new event data becomes available. On the other hand, complete assessments must be run on the full set of model and device parameters with calibration and new event data every time the latter becomes available.

97 MATHEMATICS AND COMPUTING↗

End-Use Savings Shapes Measure Documentation: Thermostat Control for Load Shifting in Large Offices

This documentation focuses on a single end-use savings shape measure - thermostat control for load shifting. The thermostat control for load shifting measure applies heating and cooling temperature setpoint adjustment for pre-conditioning before the peak window. The measure takes daily peak load schedule inputs generated by the method "Dispatch Schedule Generation" described in the "Supplemental Documentation: Dispatch Schedule Generation for Demand Flexibility Measures" to determine the start time of the peak window, and then adjusts the thermostat cooling or heating setpoints by a specified offset value from original schedules to precool or preheat the space , for a specified length of time before the start of peak window, and thus shifts load in the peak window to the pre-conditioning period. The measure is flexible and allows users to adjust the heating and cooling offset values and length of pre-conditioning period, but for this study, the load shifting strategy is applied as pre-cooling only (adjusting only cooling setpoints). The default adjustment for cooling setpoints is set to -1 degrees Celsius , and the default duration of pre-cooling is 1 hour. This measure is applicable to large offices equipped with electric HVAC system, which account for approximately 8.72% of the ComStock floor area. The thermostat control for load shifting measure demonstrates -1% daily peak demand reduction and 0% total site energy savings (0 trillion British thermal units [TBtu]) for the U.S. commercial building stock modeled in ComStock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hydrogen Plus Other Alternative Fuels Risk Assessment Models (HyRAM+) Version 5.1 Technical Reference Manual

The HyRAM+ software toolkit provides a basis for conducting quantitative risk assessment and consequence modeling for hydrogen, natural gas, and autogas systems. HyRAM+ is designed to facilitate the use of state-of-the-art models to conduct robust, repeatable assessments of safety, hazards, and risk. HyRAM+ integrates deterministic and probabilistic models for quantifying leak sizes and rates, predicting physical effects, characterizing hazards (thermal effects from jet fires, overpressure effects from delayed ignition), and assessing impacts on people. HyRAM+ is developed at Sandia National Laboratories to support the development and revision of national and international codes and standards, and to provide developed models in a publicly-accessible toolkit usable by all stakeholders. This document provides a description of the methodology and models contained in HyRAM+ version 5.1. The most significant changes for HyRAM+ version 5.1 from HyRAM+ version 5.0 are updated default leak frequency values for propane, new default component counts for different fuel types, and an improved fuel specification view in the graphical user interface.

02 PETROLEUM↗

The Design and Evaluation of Zero Trust Architecture for Electric Vehicle Charging Infrastructure: EVs @ Scale Series on EV Charging Station Cybersecurity

Implementing a zero trust architecture can significantly bolster the security of electric vehicle (EV) charging infrastructure. EV charging infrastructure includes numerous networked interfaces, each of which can present potential vulnerabilities. When these vulnerabilities are exploited, they can compromise the entire system, leading to severe operational and security risks. Zero trust is a security model that operates on the principle of "never trust, always verify," which helps manage the attack surface and limit the scope of any potential compromises. Fundamentally, this model ensures that no entity, whether inside or outside the network, is trusted by default. The design principles of zero trust include continuous verification, strict deny-by-default access controls, and micro-segmentation. Continuous verification ensures that every request is thoroughly checked, regardless of its origin. Strict access controls enforce the principle of least privilege, allowing users and devices only the minimum necessary access to perform their functions. Micro-segmentation involves dividing the network into smaller, isolated segments to prevent lateral movement in case of a breach. In the context of EV charging infrastructure, zero trust can be implemented through various strategies. For example, multi-factor authentication (MFA) can be required for engineers to access the management interfaces and control systems of charging stations. Real-time monitoring and analysis of network traffic can help detect and respond to anomalies. Systems that do not need to communicate with each other can be micro-segmented to enhance security. All communications should adhere to predefined policies to be permitted. Additionally, encrypting communications can protect sensitive information exchanged between chargers and management systems. This paper presents a zero trust architecture specifically designed for EV charging infrastructure. Implementing zero trust not only mitigates risks but also builds a resilient infrastructure capable of withstanding and quickly recovering from cyber threats. The architecture addresses six defined security objectives. A comprehensive test plan is developed to assess the architecture against these objectives, and the results of the evaluation are reported. This approach is essential for maintaining the reliability and integrity of EV charging services in an increasingly interconnected and vulnerable digital landscape. This is the first in a planned series of papers exploring the implementation of zero trust in EV charging infrastructure. Each paper will delve into different aspects and applications of zero trust, highlighting how various work processes and requirements can lead to distinct architectural designs. These architectures will be tailored to address specific security challenges and operational needs within the EV charging ecosystem, ensuring a robust and adaptable security framework.

33 ADVANCED PROPULSION SYSTEMS↗

TeMPI Shim

This is the manual for the TeMPI Shim library, whose goal is to facilitate scientific apps being loosely coupled through MPI. TeMPI Shim can be used to create and manage Message Passing Interface (MPI, see [MPI]) Communicators for Single Program, Multiple Data (SPMD, see [SPMD]) and Multiple Programs, Multiple Data (MPMD, see [MPMD]) workflows. MPI provides the MPI_APPNUM command number to each of the processes within its context. This number, starting at 0, is the application number being executed. In a case where 3 applications are being run in MPMD mode, there would be MPI_APPNUM values of 0, 1, and 2. TeMPI Shim creates intra- and inter-communicators between each pair of MPI_APPNUM values. In the aforementioned case, application 0 would have intra- and inter-communicators to speak to itself, application 1, and application 2. This is replicated for each of the applications. Additionally, TeMPI Shim creates intra- and inter-communicators for the first MPI rank of each application to directly communicate only with each other. Finally, TeMPI Shim creates its own copy of the default world communicator, i.e., MPI_COMM_WORLD. In the case where there is only a single application, it will have the communicators to only speak with itself. TeMPI Shim is useful in this case since it is considered good practice for MPI applications to copy the default world communicator and reference this copy (see [Duplicate World]_) anyways. Ultimately, it provides value independent of the number of applications present.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Summary of Expansions and Updates in R&D GREET® 2025

The research and development (R&D) version of Greenhouse gases, Regulated Emissions, and Energy use in Technologies (GREET®) model, or R&D GREET, is developed by Argonne National Laboratory (Argonne) with the support of the U.S. Department of Energy (DOE) and other federal agencies. R&D GREET is a life cycle analysis (LCA) model, structured to systematically examine the energy and environmental effects of a wide variety of transportation fuels and vehicle technologies in all transportation sub-sectors (i.e., road, air, marine, and rail) and other end-use sectors, and energy technology systems. Argonne has expanded and updated the model in many areas in R&D GREET 2025. This report provides a summary of the expansions and updates. R&D GREET is designed as an attributional LCA model, but specific consequential effects for certain pathways are included by default when they are scientifically important and/or highly policy relevant. For example, two major consequential elements – induced land use change (ILUC) for biofuels and avoided emissions for certain RNG-based pathways – are implemented by default in R&D GREET because they are highly relevant to our user base and crucial for a comprehensive evaluation of the environmental effects of these technologies. In a future version of R&D GREET, these consequential elements for biofuels and RNG could be more clearly distinguished from core attributional results. We will consider adding a highly visible toggle that would allow users to turn off or adjust these consequential impacts.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Second ARM Aerosol Chemical Speciation Monitor Users’ Meeting Report

The aerosol chemical speciation monitor (ACSM) was developed to adapt the technology of the aerosol mass spectrometer (AMS) to routine, long-term, standalone monitoring. The calculation of particulate mass concentration from ACSM data requires the measurement of the response of the instrument to aerosol of specific size and composition as well as assumptions about the instrument response based on laboratory measurements and field experience acquired over more than two decades of operation of AMS and a decade of operation of the ACSM. Three parameters in the concentration calculations that are particularly important are the NO3 response factor (RFNO3), relative ionization efficiency (RIE), and the collection efficiency (CE). The values of RFNO3 and RIEs are determined from calibration, however the jump calibration method previously used in calibration can result in errors in the RIE for sulfate. This has been corrected by implementing a continuous calibration method. The default collection efficiency is 0.5. This has been shown to result in mass loadings that do not agree with mass determinations from other instruments because of effects of composition on the vaporization of the particles. The previous work of investigators addressing this issue is discussed. After preliminary work on ACSM and scanning mobility particle sizer (SMPS) data from the U.S. Department of Energy (DOE) Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) observatory collected in late 2016 and 2017 produced a parameterization of composition dependent collection efficiency very different from the results of previous studies, SMPS data were examined and we determined that there was significant mass that the instrument did not capture because the particles with diameters larger than 465 nm are not counted by this instrument. Data for the ultra-high-sensitivity aerosol spectrometer (UHSAS), SMPS, and ACSM are available for nearly all of 2019. The data from UHSAS and SMPS collected in 2019 were compared. We found that the UHSAS data has particle counts and total volumes significantly less than measured by the condensation particle counter (CPC) and SMPS. The SMPS data were extended by fitting the average volume distribution with a log normal curve and using this relationship to estimate a mass value for the SMPS over extended diameter range. The extended SMPS mass values result in a CDCE parameterization that is in better agreement with the results of other investigators, but is still different from other formulations. The working group recommends that the ACSM data be processed with a collective efficiency (CE)=1, that this be documented clearly in the metadata, and the use of the default CE of 0.5 or a formulation of composition-dependent collection efficiencies (CDCE) chosen by the user should be implemented based on the ammonium nitrate mass fraction. This is clearly necessary for the wintertime SGP ACSM data because of the high nitrate concentrations.

47 OTHER INSTRUMENTATION↗

User’s Manual for RESRAD-RDD&IND Code Version 2: Vol. 2—User’s Guide for RESRAD-RDD&IND Code

Version 2.0 of the RESRAD-RDD&IND computer code is designed to support the implementation of protective action guides (PAGs) after a nuclear emergency incident including a radiological dispersal device (RDD) and/or an improvised nuclear device (IND) incident (EPA 2017). Eight different group types, addressing various decisions, are available for selection. The RESRAD-RDD&IND code calculates radiological doses, stay times, etc., for the selected group that the user wishes to focus on. (That is, the results for all the groups are not calculated simultaneously, and the input for those other groups do not matter, although some parameter values are shared between groups.) Version 2.0 has a user-friendly interface so that the RESRAD-RDD&IND code can be used with minimal training. For example, the user can select the major characteristics of the problem-event type, source term, and decision type from the left side of the interface and then calculate the results with the default assumptions for the exposure scenarios. More in-depth analysis would include specifying site-specific exposure scenario characteristics in the right side of the interface. The procedures for data entry and results viewing are self-explanatory. This is because common window maneuvering features and text instructions were incorporated in the interface design. General and context-specific help are available to aid users entering parameter values, as well. The RESRAD-RDD&IND computer code gives the user the option to select either an RDD or IND incident for analysis. For an RDD event analysis, 11 radionuclides (Am-241, Cf-252, Cm-244, Co-60, Cs-137, Ir-192, Po-210, Pu-238, Pu-239, Ra-226, and Sr-90) are included. These 11 radionuclides are the radionuclides most likely used for an RDD. More than 90 radionuclides can be selected for an IND event analysis. Initial default concentrations are provided for 44 radionuclides for a uranium-fueled IND event. These 44 radionuclides are those that would contribute significantly to the radiation dose associated with a uranium-fueled bomb detonation. The radionuclides generated from ingrowth of these 44 initial radionuclides are also automatically included in the analysis. Pu-239, Cs-134m, Ru-105, and Rb-89 and their progeny can be selected for analysis if they are detected and their concentrations are determined. This user’s guide, which is Volume 2 of the User’s Manual for RESRAD-RDD&IND Code Version 2, provides instructions to users on how to install the RESRAD-RDD&IND code, navigate the interface, and use the various features, including those discussed above, to set up an analysis and view/print the results in text outputs. Volume 1 of the User’s Manual for RESRAD-RDD&IND Code Version 2 (Yu et al. 2026), which contains descriptions of the methodology and theoretical basis for dose modeling and the mathematical equations implemented in the code, can be accessed and viewed through the Help menu in the code or can be downloaded from the RESRAD website (https://resrad.evs.anl.gov).

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Detecting and Blocking Network Attacks at Ultra High Speeds

Stateful, in-depth, in-line traffic analysis for intrusion detection and prevention has grown increasingly more difficult as the data rates of modern networks rise. One point in the design space for high-performance network analysis - pursued by a number of commercial products - is the use of sophisticated custom hardware. For very high-speed processing, such systems often cast the entire analysis process in ASICs. This project pursued a different architectural approach, which we term Shunting. Shunting marries a conceptually quite simple hardware device with an Intrusion Prevention System (IPS) running on commodity PC hardware. The overall design goal is was to keep the hardware both cheap and readily scalable to future higher speeds, yet also retain the unparalleled flexibility that running the main IPS analysis in a full general-computing environment provides. The Shunting architecture we developed uses a simple in-line hardware element that maintains several large state tables indexed by packet header fields, including IP/TCP flags, source and destination IP addresses, and connection tuples. The tables yield decision values the element makes on a packet-by-packet basis: forward the packet, drop it, or divert ('shunt') it through the IPS (the default). By manipulating table entries, the IPS can, on a fine-grained basis: (i) specify the traffic it wishes to examine, (ii) directly block malicious traffic, and (iii) 'cut through' traffic streams once it has had an opportunity to 'vet' them, or (iv) skip over large items within a stream before proceeding to further analyze it. For the Shunting architecture to yield benefits, it needs to operate in an environment for which the monitored network traffic has the property that - after proper vetting - much of it can be safely skipped. This property does not universally hold. For example, if a bank needs to examine all Web traffic involving its servers for regulatory compliance, then a monitor in front of one of the bank's server farms cannot safely omit a subset of the traffic from analysis. In this environment, Shunting cannot realize its main performance benefits, and the monitoring task likely calls for using custom hardware instead. However, in many other environments we find Shunting holds promise for delivering major performance gains. This arises due to the the widely documented 'heavy tail' nature of most forms of network traffic, which we might express as 'a few of the connections carry just about all the bytes.' The key additional insight is '... and very often for these few large connections, the very beginning of the connection contains nearly all the information of interest from a security analysis perspective.' We argue that this second claim holds because it is at the beginning of connections that authentication exchanges occur, data or file names and types are specified, request and reply status codes conveyed, and encryption is negotiated. Once these occur, we have seen most of the interesting facets of the dialog. Certainly the remainder of the connection might also yield some grist for analysis, but this is generally less likely, and thus if we want to lower analysis load at as small a loss as possible of information relevant to security analysis, we might best do so by skipping the bulk of large connections. In a different context, the 'Time Machine' work by Kornexl and colleagues likewise shows that in some environments we can realize major reductions in the volume of network traffic processed, by limiting the processing to the first 10-20 KB of each connection. As a concrete example, consider an IPS that monitors SSH traffic. When a new SSH connection arrives and the Shunt fails to find an entry for it in any of its tables (per-address, per-port, per-connection), it executes the default action of diverting the connection through the IPS. The IPS analyzes the beginning of the connection in this fashion. As long as it is satisified with the dialog, it reinjects the packets forwarded to it so that the connection can continue. If the connection successfully negotiates encryption, the IPS can no longer profitably analyze it, so it downloads a per-connection table entry to the Shunt specifying that the action for the connection in the future is 'forward.' For heavy-tailed connections, this means a very large majority of the connection's packets will now pass through the Shunt device without burdening the IPS with any further analysis load. On the other hand, if the IPS is dissatisfied with some element of the initial dialog, it downloads a 'drop' entry to terminate the connection. Note that by providing for reinjection, we can promote an intrusion detection system into an intrusion prevention system, one that does not merely detect attacks but can block them before they complete. Reinjection also allows the IPS to normalize traffic to remove ambiguities that attackers can leverage to evade the IPS.

99 GENERAL AND MISCELLANEOUS↗

Machine Learning for Solar Accessibility: Implications for Low-Income Solar Expansion and Profitability

The solar industry in the US typically uses a credit score such as the FICO score as an indicator of consumer utility payment performance and credit worthiness to approve customers for new solar installations. Using data on over 800,000 utility payment performance and over 5,000 demographic variables, we compare machine learning and econometric models to predict the probability of default to credit-score cutoffs. Here, we compare these models across a variety of measures, including how they affect consumers of different socio-economic backgrounds and profitability. We find that a traditional regression analysis using a small number of variables specific to utility repayment performance greatly increases accuracy and LMI inclusivity relative to FICO score, and that using machine learning techniques further enhances model performance. Relative to FICO, the machine learning model increases the number of low-to-moderate income consumers approved for community solar by 1.1% to 4.2% depending on the stringency used for evaluating potential customers, while decreasing the default rate by 1.4 to 1.9 percentage points. Using electricity utility repayment as a proxy for solar installation repayment, shifting from a FICO score cutoff to the machine learning model increases profits by 34% to 1882% depending on the stringency used for evaluating potential customers.

Davuluri, Sruthi↗