Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “DAC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Direct Air Capture Case Studies: Solvent System

This case study provides cost and performance estimates for a solvent-based direct air capture (DAC) system at varying scales. The performance of the DAC system is largely based upon vendor performance while the costs of the system were developed as independently as possible. This study is representative of an example DAC system configuration and is not an optimized design.

42 ENGINEERING↗

Nanosecond Gated CMOS Camera (NSGCC) ICD (Rev. 2.1)

The Ultra-Fast X-ray Imager (UXI) program is an ongoing effort at Sandia National Laboratories to create high speed, multi-frame, time-gated Read Out Integrated Circuits (ROICs), and a corresponding suite of photodetectors to image a wide variety of High Energy Density (HED) physics experiments on both Sandia’s Z-Machine and LLNL’s National Ignition Facility (NIF). Several cameras have been designed over the length of the program; one of the most recent is the Icarus, which is an improvement on past imagers (Furi and Hippogriff). A second sensor that can be connected is the Daedalus sensor. The Icarus is a 1024 × 512-pixel array with either 25 μm or 8 µm spatial resolution containing four frames of storage per pixel and has improved timing generation and distribution components while achieved 2 ns time gating. The Daedalus sensor is also a 1024 x 512-pixel array with 25 µm special resolution containing three frames of storage per pixel and has an increased set of features for a wider variety of applications from interlacing of rows in each frame to configurability of all shutters. See Section 14 for details regarding the Icarus implementation of the firmware and Section 15 for details regarding the Daedalus implementation. Due to the unique test environments UXI sensors are targeted for, full custom hardware was required to physically mount an Icarus or Daedalus sensor, manage its various functions, and read out pixel data for transfer to a host computer. Beyond experimental functionality, the hardware also needed to accommodate sensor characterization requirements. Lawrence Livermore National Laboratory’s ‘Version 4.0 Board’ was the result of these efforts. It mounts all the components required to fully utilize the Icarus and Daedalus sensors including analog to digital converters to convert pixel data and various system voltages to digital form for readout and analysis, DAC channels for remote configuration of critical bias voltages, static random-access memories to buffer pixel data, RS422 and Gigabit Ethernet communications for remote access, and an FPGA to tie these components together. This document describes the FPGA electrical interfaces in detail to allow the reader a greater understanding of the device, and to facilitate implementation of custom software to control and manage it. The Version 4.0 Board is a continuation of the Nano-second Gated CMOS hardware design that retains much of the functionality of the Version 1.0 Board while adding features including a DAC instead of digital potentiometers, as well as sensors for pressure and radiation. The Version 4.0 board is intended for applications requiring tight form-factor enclosures. It is composed of two stacking boards; one holds the FPGA and regulators to power the various components of the board while the other contains the mating connector to the sensor, image-readoff ADCs, the DAC, and other components.

42 ENGINEERING↗

Direct Air Capture-Based Carbon Dioxide Removal with United States Low-Carbon Energy and Sinks

The overall objective of this project was to complete an initial design of a commercial-scale, Carbon Capture and Storage system for Direct Air Capture (CCS-DAC) that separates and stores a minimum of 100,000 tonnes/year (t/yr.) net CO 2 from air. Three geographically diverse host sites will be used to determine the impact of different climates on the design and cost of the CCS-DAC systems; California (dry-hot), Louisiana (humid-hot), and Wyoming (mid-continental). In addition, the impact of using different low-carbon energy sources was also examined. The focus of this project was to geologically store the CO 2 , rather than the utilization of CO 2 . This Final Scientific/Technical Report is a collection of the deliverables for the project. The project team was able to successfully complete all the necessary tasks needed to determine the feasibility of the designs and operational needs of the DAC systems for each location. The data created by this allowed the project team to conduct the required evaluations to meet the requirements of the deliverables. The following deliverables were drafted and submitted to DOE prior to the conclusion of the project: (1) Initial Engineering Design; (2) Costing Estimate; (3) Techno-Economic Analysis (TEA); (4) Life Cycle Analysis (LCA); (5) Business Case Assessment; and (6) Technology EH&S Risk Assessment.

42 ENGINEERING↗

Abstract for CRADA between National Energy Technology Laboratory and Elysia LLC

The National Energy Technology Laboratory (NETL) and Elysia Labs LLC are embarking on a collaborative project to develop and evaluate a low-cost, high-performance carbon dioxide capture process for the burgeoning Direct Air Capture (DAC) industry. The partnership will focus on developing an electrospun fiber based air contactor that promises higher efficiency and lower costs to set a new standard in the DAC field. The expected outcomes of this collaboration include the creation of a DAC contactor that significantly outperforms existing technologies in cost, capacity, cycle time, regeneration energy, and durability. This project is a result of an awarded project from the Department of Energy’s Direct Air Capture Pre-Commercialization Technology Prize.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

CFD Model Development of a Small-Scale Fixed-Bed Reactor for Direct Air Capture of CO2

Direct air capture (DAC) is a promising approach to significantly reduce the CO2 concentration in the ambient air. This approach requires the extraction of CO2 from air with ultra dilute CO2 concentration which makes this approach more expensive than point source CO2 capture. Several efforts are being made in academics and industry to develop cost-efficient sorbents and solvents suitable for DAC. One of them is polymer with intrinsic microporosity (PIM) which is often used for CO2 capture because of its higher porosity and rigidity. A novel, cost-efficient aminated PIM sorbent, PF-15-TAEA, was developed at the National Energy Technology Laboratory for DAC applications. The current work is focused on the computational investigation of the CO2 capture by this novel sorbent from a gas mixture with ultra dilute concentration of CO2 in dry and humid conditions in a laboratory-scale fixed-bed reactor.

Aziz, Hossain↗

Design, Fabrication, and testing of Direct Air Capture Sorbent modules to increase understanding of trade-offs in pressure drop and capture efficiency

Conference presentation for the work entitled “Design, Fabrication, and testing of Direct Air Capture Sorbent modules to increase understanding of trade-offs in pressure drop and capture efficiency”. In recent years, there has been a growing interest in Direct Air Capture (DAC) of CO2. This technology is gaining attention as a method to enhance the reduction of atmospheric greenhouse gases (GHGs), particularly when used alongside other decarbonization strategies. The route for efficient and net carbon negative DAC is challenging because CO2 in the atmosphere is highly diluted (~400ppm). This work, utilizing 3D printing capabilities for rapid prototyping, presents application-based findings on the design, fabrication, and testing of DAC module form factors that house solid sorbents. The work leverages an experimental rig that can achieve air throughput and velocities approaching that which are anticipated for commercial scales. The tradeoffs of pressure drop, footprint and capture efficiency are discussed for different orientations of a NETL patented sorbent material.

Riley, Jarrett↗

Demonstration of a Continuous Motion Direct Air Capture System

Global Thermostat (GT) has developed a process that addresses the primary technical challenges associated with direct air capture (DAC): the ability to process enormous volumetric flowrates of air and provide the energy for regeneration at acceptable cost. However, at current, there is opportunity for improvement in overall capture costs and especially in capital costs. While GT has advanced its base technology to TRL levels supporting commercial deployments, its research strategy includes alternative technology embodiments that enable substantial reductions in the cost per tonne of CO 2 removed. The objective of this project is to advance the most promising of these embodiments, where a DAC plant is operated in a continuous fashion rather than a discrete stepwise fashion (GT’s commercial scale technology approach). The Continuous Motion Direct Air Capture (cDAC) System’s advantages over the GT baseline stepwise DAC platform have been proposed primarily as a reduction in the complexity required for starting and stopping a movement system, relaxing requirements for other components designed for a rapid switching application, and a flattening of the sharp instantaneous fluid flowrates into steady-state mass & energy flows to enable smoother operation and easier heat integration. These advantages can lead to shorter cycle times, greater plant reliability, and lower capital expense. The primary objective of this project is the design, construction, commissioning, and operation of a field-test unit (FTU) at a scale in the range of ~200 tons CO 2 per year. Data generated from the operation campaign would then be used in a prescreening techno-economic analysis (TEA) and life cycle analysis (LCA), allowing this process to be compared to other carbon capture technologies.

42 ENGINEERING↗

Fluor Solvent Evaluation and Testing New Scope: Techno-economic Assessment of EEMPA Solvent for CO 2 Separations from Natural Gas Combined Cycle Power Plant

In this project, a techno-economic analysis (TEA) and sensitivity studies were conducted to assess the PNNL’s leading water-lean CO 2 capture solvent, EEMPA, for capture CO 2 from a natural gas combined cycle (NGCC) power plant at different levels of capture rate. Process models for the NGCC power plant, integrated with EEMPA carbon capture processes, were developed in Aspen Plus V14 using the most up-to-date property package for EEMPA-H 2 O-CO 2 system. The TEA evaluated EEMPA carbon capture process at normal capture rates (90%, 95% and 97%) against Case B32B (Cansolv) described in NETL Rev4a baseline report, and at higher capture rates aimed at achieving zero or negative emissions from the power plant (400 ppmv, 200 ppmv, and 100 ppmv CO 2 in exhaust gas), compared to typical Direct Air Capture (DAC) technologies. A manuscript was drafted for peer-reviewed publication. The results suggested that the carbon capture cost reaches a minimum of $\$$53.7/tonne CO 2 at 90% capture rate. Compared to Cansolv, one of the industrial benchmarks, EEMPA demonstrates 2-4% cost savings at capture rates up to 95%, but minimal savings at higher capture rate. The water lean-solvent system proves economically attractive for achieving moderate negative emissions (about 200 ppmv CO 2 in exhaust gas, and equivalent to 50% CO 2 removal from air) for NGCC flue gas, with marginal capture costs comparable to direct air capture (DAC) technologies. A sensitivity analysis results reveal that its economic advantage, unaffected by EEMPA price due to low solvent loss and degradation rate. However, the marginal carbon capture cost exceeds $\$$1,000/tonne CO 2 when transitioning from moderate to extreme negative emissions (100 ppmv CO 2 in exhaust gas), suggesting that water-lean solvents may not be economically competitive with other DAC technologies for removing more than 75% CO 2 from air. In addition, initial connection was established with Technology Center Mongstad (TCM) for a potential pilot testing proposal. However, detailed modeling and proposal preparation was not conducted due to the delay of non-disclosure agreement.

20 FOSSIL-FUELED POWER PLANTS↗

The right conditions for high-precision dynamic temperature and heat capacity measurement via pyrometry and conductivity

The pursuit of accurate bulk temperature T under extreme conditions has been a long-standing goal of the high pressure science community, complicated by a lack of data to inform models. To reach these extremely high-pressure, high-temperature (high P − T) conditions, a combination of dynamic and heated static experiments (e.g., diamond or gem anvil cel experiments) are used. For example, in a diamond anvil cell (DAC) experiment, a sample placed in the DAC is first pressurized. Following pressurization, the sample T is increased either by heating the entire DAC (usually using resistive heating, and limited to ∼1000K) or by applying intense laser power to the sample surfaces. In a dynamic experiment, the process of pressurizing the sample also heats it. In the case of shock physics experiments, such heating is substantial, easily reaching thousands of Kelvin; in our work we have seen T ∼17000K. Most methods of measuring temperature at ambient are not compatible with experiments under these high-pressure, high-temperature conditions: thermocouples break, melt, or have conductivity properties that differ from ambient where they are calibrated; thermometers would melt; both are too slow. As a result most methods are based on non-contact techniques such as x-ray diffraction broadening, neutron scattering, or optical methods. Of these, optical methods using the visible and near-infrared region of the spectrum are the most commonly used as the sources and detectors are readily available. In the case of optical methods the optical depth, and therefore the measurement location, is limited to the surface. When a window or anvil material is used, heat flows from the sample into the window/anvil. Likewise, if the sample undergoes a change in thermodynamic state, such as expansion upon release, different T may be expected. As a result, the surface or apparent temperature T app measurement will differ from the bulk or interior temperature that is desired. This surface measurement must be related to the bulk measurement using thermal transport models and material models. While it is tempting to conclude that one should just use x-ray methods that directly probe the interior, even these methods have been shown to depend on thermal transport and material models. Regardless of the method used to create the high P − T condition, therefore, we must understand the role of thermal transport and material models upon our interpretation of the T measurement, as well as the errors and uncertainties associated with the choice of models used in the analysis. This is a substantial area of research and this paper is by no means a complete survey of the relevant sources of uncertainty. For example, we have yet to begin to address alternate transport models in a detailed manner (e.g., Tan-Ahrens), or the many models that use additional layers to approximate melting, turbulence, or epitaxial phenomena). Likewise, we have not explored the impact upon uncertainty of thermal models that use temperature-dependent thermal transport coefficients, or the wide range of material models that can be applied. Instead, this paper focuses on using one simple model, the Urtiew-Grover model, to understand the sources of error in T measurement so that we may identify how best to focus future research efforts to return the best improvements and avoid working on over-optimizing a single type of measurement. To this end, we work through some of the best and worst case scenarios for T measurement.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Biomolecular Films for Direct Air Capture of CO 2

Efficient utilization of CO 2 is amongst the most critical cost drivers in algal biomass production in open pond systems. CO 2 delivery costs represent approximately 20% of the final biomass selling price in algal mass cultivation systems. Technologies that enable direct air capture (DAC) of atmospheric CO 2 to decouple algae cultivation from CO 2 point sources thus present an opportunity to improve the economics and resource potential of algal biomass. Current DAC technologies typically employ amine- or caustic-based absorption, demanding significant water and/or energy inputs and incurring substantial capital expenditures. Conversely, bio-based approaches to DAC offer a means to bypass conventional technoeconomic and sustainability hurdles. We integrate recent advances in computational metabolic modeling, algal genetic engineering, algal cultivation, and algal biomass upgrading to enable directed localization and self-assembly of carbonic anhydrase molecular films to gas-liquid interfaces for enhanced CO 2 capture and conversion.

09 BIOMASS FUELS↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗

The performance of solvent-based direct air capture across geospatial and temporal climate regimes

Liquid-solvent direct air capture (DAC) is a prominent approach for carbon dioxide removal but knowing where to site these systems is challenging because it requires considering a multitude of interrelated geospatial factors. Two of the most pressing factors are: (1) how should DAC be powered to provide the greatest net removal of CO 2 and (2) how does weather impact its performance?. To investigate these questions, this study develops a process-level model of a liquid-solvent DAC system and couples it to a 20-year dataset of temperature and humidity conditions at a ~9km resolution across the contiguous US.

54 ENVIRONMENTAL SCIENCES↗

Direct air capture of CO2: from insights into the current and emerging approaches to future opportunities

The rapid development of direct air capture (DAC) technologies has become critical in order to remove CO 2 from the atmosphere and limit global warming to a maximum of 1.5°C. In this perspective, we provide a mini review of the current research on the emerging liquid- and solid-based sorbent materials to capture CO 2 , summarize the existing challenges of DAC technologies, and suggest future research directions to accelerate the development of DAC systems. In particular, the desired properties for a breakthrough sorbent that efficiently captures CO 2 from the air and releases it for sequestration are described.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Compact, low power, high resolution ADC per pixel for large area pixel detectors

A compact ADC circuit can include one or more comparators, and a serial DAC (Digital-to-Analog) circuit that provides a signal to the comparator (or comparators). In addition, the ADC circuit can include a serial DAC redistribution sequencer that can provide a plurality of signals as input to the serial DAC circuit and is subject to a redistribution cycle and which receives as input a signal from a data multiplexer whose input connects electronically to an output of the comparator. The circuit can further include an ADC code register that provides an ADC output that connects electronically to the output of the comparator and the input to the data multiplexer. Shared logic circuitry for sharing common logic between pixels can be included, wherein the shared logic circuitry connects electronically to the data multiplexer and the ADC code register, wherein the shared logic circuitry promotes area and power savings for the pixel detector circuit.

Zimmerman, Tom↗

Compact, low power, high resolution ADC per pixel for large area pixel detectors

A compact ADC circuit can include one or more comparators, and a serial DAC (Digital-to-Analog) circuit that provides a signal to the comparator (or comparators). In addition, the ADC circuit can include a serial DAC redistribution sequencer that can provide a plurality of signals as input to the serial DAC circuit and is subject to a redistribution cycle and which receives as input a signal from a data multiplexer whose input connects electronically to an output of the comparator. The circuit can further include an ADC code register that provides an ADC output that connects electronically to the output of the comparator and the input to the data multiplexer. Shared logic circuitry for sharing common logic between pixels can be included, wherein the shared logic circuitry connects electronically to the data multiplexer and the ADC code register, wherein the shared logic circuitry promotes area and power savings for the pixel detector circuit.

Fahim, Farah↗

Demonstration of a diamond anvil cell platform at the Linac Coherent Light Source: Capabilities and Outlook

A novel x-ray free electron laser (XFEL) diffraction setup for use with diamond anvil cells (DACs) at the Linac Coherent Light Source (LCLS) is described. Using the new diamond window at the Matter at Extreme Conditions (MEC) instrument, it allows hard x-ray experiments on DACs to be performed in air. The platform is described along with alignment and calibration procedures and details of the x-ray beam and diagnostics. Example data are presented, including a reversible XFEL induced phase transition in CsPbI3. The DAC setup was commissioned at MEC, but is applicable to most LCLS instruments where the unique pulse structures available at LCLS offer access to new ultrafast experimental techniques at high pressure.

Diamond Anvil Cells, LCLS, XFEL, High-Pressure↗

Design and Commissioning of a Deuterium-Tritium Gas Delivery System for Muon Catalyzed Fusion in a Diamond Anvil Cell

We report the design, commissioning, and operation of deuterium-deuterium (DD) and deuterium-tritium (DT) gas delivery systems developed to load a diamond anvil cell (DAC) beam target for muon-catalyzed fusion (muCF). The DAC approach enables DT fuel to be compressed to GPa pressures at more than twice the liquid density and heated from cryogenic temperatures through 500 K, opening access to a substantially expanded parameter range for muCF kinetics and yield measurements. In this approach, DT is cryo-condensed to a liquid in a minichamber and then compressed in the DAC using a helium-driven pneumatic membrane, achieving high pressures in a millimeter-scale DT sample volume. A DD gas delivery system was designed and used to validate the experimental apparatus, measure the gas quantities needed for filling, develop operational experience, and collect kinetics and yield data with DD targets. The DT gas delivery system adds tritium-specific capabilities for inventory minimization, secondary containment, and activity monitoring. The DT system integrates depleted uranium storage beds and a liquid helium cryogenic condenser used for pressure building and cryopumping. High-purity delivery is provided by a rapid-response palladium permeator. The system is housed in a helium-atmosphere glovebox held at negative pressure with continuous cleanup. We present the process and instrumentation design, a failure modes and effects analysis (FMEA), and data from the experiment's in situ Raman spectrometer, which provides direct confirmation of target loading and composition through the optically clear diamond anvils. The 2024 and 2025 DT campaigns achieved repeatable target fills and operation with no measurable tritium releases to the stack, demonstrating safe, high-purity DT loading at novel density-temperature conditions for muCF studies.

Koukina, Elena [Acceleron Fusion]↗

Graphical User Interface for a Biasing Board for the PSEC6

The PSEC6 is an application-specific integrated circuit (ASIC) designed for a readout system for a large area picosecond photodetector (LAPPD). The PSEC6 is currently in fabrication and pending testing. The testing system for the PSEC5, the previous iteration of the ASIC, required expensive and non-portable equipment, because the ASIC needs twelve adjustable reference voltages. The new testing system consists of an low-cost, open-source, cross-platform graphical user interface (GUI), a digital system, and a biasing board. The digital system is the interface between the GUI and biasing board, and can be implemented on a microcontroller or field-programmable gate array (FPGA). The biasing board contains twelve digital-to-analog converters (DACs) that are configurable via the GUI, which gives users the ability to write voltage values to all or specific DACs. The GUI was developed in C on Linux using the widget library GTK4 and cross-compiled for Windows compatibility. I2C and SPI protocols were implemented on an Adafruit Feather ESP32-S3 microcontroller to write commands to the DACs and PSEC6. A hardware implementation of the I2C protocol is in development on an FPGA. Since LAPPDs will be used by the Accelerator Neutrino Neutron Interaction Experiment (ANNIE) at Fermilab, the PSEC6 testing system in this internship project can potentially benefit future neutrino research. The project is relevant to the Department of Energy’s microelectronics mission, because the PSEC6 is an ASIC that will handle fast time signals arriving from the detector for readout. It also provided experience with building a cross-platform user interface, practicing digital design and implementation in hardware description language (HDL), and using simulations to inform new design iterations.

Guerrero, Sasha Camila [North Central Coll.]↗