Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CsY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The HEAO 3 gamma-ray spectrometer

The third High Energy Astronomy Observatory (HEAO 3), successfully launched into low earth orbit on September 20, 1979, carries a large high-resolution gamma-ray spectrometer designed for cosmic nuclear spectroscopy. This gamma-ray spectrometer (the HEAO C-1 experiment) consists of a cluster of four coaxial high-purity germanium detectors, each with a volume of approximately 100 cu cm. Surrounding the germanium detectors is a 6.6-cm thick CsI shield operating in active anticoincidence with the central detectors and defining a field of view of about 30 deg FWHM. An initial energy resolution of 3 keV FWHM at 1.46 MeV was achieved for each detector. All valid events in the germanium detectors are individually analyzed by an 8192-channel pulse area analyzer and transmitted at a maximum rate of 15.6 evens/s for each detector. During a 6-month mission, the experiment will perform a complete sky survey for narrow cosmic gamma-ray line emission to the sensitivity level of about 0.0001 photons/sq cm s over an operating energy range of 0.05-10 MeV.

Mahoney, W. A.↗

HEAO 3 measurements of the atmospheric positron annihilation line

The atmospheric positron annihilation line at 511 keV was the first gamma-ray line observed which originates from processes of astrophysical importance. Measurements of the properties of a positron annihilation line make it possible to determine many of the physical conditions present at the source of emission. An investigation was conducted of the 511-keV line measured with the HEAO C-1 experiment. The HEAO C-1 experiment consisted of a cluster of four, large, high-purity germanium detectors surrounded by an active anticoincidence CsI shield. A strong atmospheric line was measured at 511.07 + or - 0.10 keV. The net atmospheric emission has been accurately determined as a function of geomagnetic latitude and varies from 0.01 photons/sq cm-sec-sr near the magnetic equator to 0.035 photons/sq cm-sec-sr at a latitude of 55 deg.

Mahoney, W. A.↗

A high-resolution measurement of the 2.223 MeV neutron capture line in a solar flare

An intense solar flare lasting 40 s was observed by the HEAO 3 gamma-ray spectrometer on November 9, 1979, at 3:05 UT. The flare was observed in four high-resolution germanium detectors as well as in five CsI shield detectors over an energy range of 100 keV to above 5 MeV. Of particular interest is a line feature at 2.2248 + or - 0.0010 MeV. The precise energy measurement provides unambiguous evidence that this is the (H-1)(n, gamma)(H-2) line resulting from neutron capture on hydrogen. An upper limit of 5 keV is found for the natural line width. The time dependence of the neutron capture line is discussed as well as the overall characteristics of the November 9 flare.

Prince, T. A.↗

16 November 1979 gamma-ray bursts observed with HEAO-3 High-Resolution Gamma-Ray Spectrometer

On 1979 November 16, two gamma-ray bursts were observed by the High-Resolution Gamma-Ray Spectrometer on HEAO-3. The first event occurred at 14:16:41 U.T. and lasted about eight seconds. This event was detected only by the instrument's five CsI anticoincidence shield pieces. The second event occurred 61 sec later, at 14:17:42, and lasted about 18 sec. This event was clearly detected by the high-resolution germanium detectors. Because of the close temporal coincidence of the two events, the possibility is considered that both events originated from one celestial source, and that the scanning motion of HEAO-3 (nominal spin period 20 min) excluded the first from the approximately 30 deg FWHM field of view of the germanium detectors but included the second. Directional information from the relative response of the five shield pieces and the earth occultation constraint are all consistent with this interpretation and suggest a source location near RA equals 10 hr, Dec equals 45 deg. No significant spectral features appear in the high-resolution data from the second burst.

Wheaton, W. A.↗

Gamma-ray and optical observations of the 1979 November 8 solar flare

The solar flare on 1979 November 8 11h 21m 28s UT was observed by the Tel Aviv telescope of the Big Bear Solar Observatory and the High Resolution Gamma-Ray Spectrometer on the High Energy Astronomy Observatory HEAO 3. Photographs in alpha hydrogen show the development of the flare and a subsequent Moreton wave. Although the flare was not detected with the high spectral resolution germanium detectors, the HEAO C-1 CsI shield detected a statistically significant signal above 80 keV, from 420 to 585 keV, and above 3.8 MeV. The temporal structure of microwave, optical, X-ray, and gamma-ray emission is consistent to within about 1 s with a simultaneous flare response at all energies. There is no evidence for either second-stage acceleration of charged particles (Bai and Ramaty, 1979) or a delay between gamma-ray and X-ray continuum emission due to energy-dependent electron energy loss times (Bai and Ramaty).

Riegler, G. R.↗

High resolution X- and gamma-ray spectroscopy of solar flares

A balloon-borne X- and gamma-ray instrument was developed, fabricated, and flown. This instrument has the highest energy resolution of any instrument flown to date for measurements of solar and cosmic X-ray and gamma-ray emission in the 13 to 600 keV energy range. The purpose of the solar measurements was to study electron acceleration and solar flare energy release processes. The cosmic observations were to search for cyclotron line features from neutron stars and for low energy gamma-ray lines from nucleosynthesis. The instrument consists of four 4 cm diameter, 1.3 cm thick, planar intrinsic germanium detectors cooled by liquid nitrogen and surrounded by CsI and NaI anti-coincidence scintillation crystals. A graded z collimator limited the field of view to 3 deg x 6 deg and a gondola pointing system provided 0.3 deg pointing accuracy. A total of four flights were made with this instrument. Additional funding was obtained from NSF for the last three flights, which had primarily solar objectives. A detailed instrument description is given. The main scientific results and the data analysis are discussed. Current work and indications for future work are summarized. A bibliography of publications resulting from this work is given.

Lin, R. P.↗

A Far Ultraviolet Imaging Spectrograph for Shuttle

The development of the Far Ultraviolet Imaging Spectrograph (FUVIS) Shuttle sortie missions, is described. Objectives of the experiment are to obtain spatially-resolved far-ultraviolet spectra of extraterrestrial sources, including emission-line and reflection nebulae, diffuse background radiation, extragalactic objects, and comets. The use of fast focal ratio (f/1) Schmidt optics and an opaque CsI photocathode which affords high quantum efficiency in the far-UV provides the maximum possible diffuse source sensitivity. Measured emission line intensities of 5 Rayleighs (or continua of intensity 1 R/A) in 300 sec exposures are expected. The development includes a dedicated pointing platform and a low light level television camera for payload specialist use in target acquisition and guiding.

Carruthers, G. R.↗

Biocatalyzed processes for production of commodity chemicals: Assessment of future research advances for N-butanol production

This report is a summary of assessments by Chem Systems Inc. and a further evaluation of the impacts of research advances on energy efficiency and the potential for future industrial production of acetone-butanol-ethanol (ABE) solvents and other products by biocatalyzed processes. Brief discussions of each of the assessments made by CSI, followed by estimates of minimum projected energy consumption and costs for production of solvents by ABE biocatalyzed processes are included. These assessments and further advances discussed in this report show that substantial decreases in energy consumption and costs are possible on the basis of specific research advances; therefore, it appears that a biocatalyzed process for ABE can be developed that will be competitive with conventional petrochemical processes for production of n-butanol and acetone. (In this work, the ABE process was selected and utilized only as an example for methodology development; other possible bioprocesses for production of commodity chemicals are not intended to be excluded.) It has been estimated that process energy consumption can be decreased by 50%, with a corresponding cost reduction of 15-30% (in comparison with a conventional petrochemical process) by increasing microorganism tolerance to n-butanol and efficient recovery of product solvents from the vapor phase.

Ingham, J. D.↗

A position sensitive phoswich hard X-ray detector system

A prototype position sensitive phoswich hard X-ray detector, designed for eventual astronomical usage, was tested in the laboratory. The scintillation crystal geometry was designed on the basis of a Monte Carlo simulation of the internal optics and includes a 3mm thick NaI(T1) primary X-ray detector which is actively shielded by a 20 mm thick CsI(T1) scintillation crystal. This phoswich arrangement is viewed by a number two inch photomultipliers. Measured values of the positional and spectral resolution of incident X-ray photons are compared with calculation.

Dean, A. J.↗

Counterstreaming hydrogen and oxygen ions observed in the magnetosphere on ISEE-1

Counterstreaming ions or ions travelling simultaneously both parallel and antiparallel to the magnetic field direction have been briefly noted in the literature but have not been studied previously in depth. Over 60 counterstreaming ion (CSI) events observed on the ISEE-1 satellite have been studied. They were found to occur at altitudes of about 2 to 8 earth radii on L shells of about 5 to 12 in the evening-to-morning sector from about 1700-0900 LT. Often both oxygen and hydrogen ions at a number of energy levels are counterstreaming but some events show only either oxygen or hydrogen ions involved. One particularly interesting event shows only counterstreaming oxygen ions with 417 eV energy; oxygen ions of lower energy (215 eV) and above (630-17,000 eV) and all the hydrogen ions between 215-17,000 eV energy have lower fluxes and/or nearly isotropic pitch angle distributions. This event correlates well with wave activity in the 17-100 Hz band and is also accompanied by 200 eV downgoing and 400 eV upgoing electrons. Details of this event and the other counterstreaming events are presented.

Horita, R. E.↗

The nature of symmetric instability and its similarity to convective and inertial instability

It is shown that there exists a local similarity among SI (Symmetric Instability), BI (Buoyancy or Convective Instability), and II (Inertial Instability) even for fully nonlinear viscous motion. The most unstable slope angles for SI and Moist SI motions are analyzed based on parcel energetics. These considerations also suggest qualitatively that CSI (Conditional SI) circulations will be slantwise and lie between the moist most unstable slope and dry least stable slope of the basic state.

Xu, Q.↗

Severe storm identification with satellite microwave radiometry: An initial investigation with Nimbus-7 SMMR data

The severe weather characteristics of convective storms as observed by the Nimbus 7 Scanning Multichannel Microwave Radiometer (SMMR) are investigated. Low 37 GHz brightness temperatures (due to scattering of upwelling radiation by precipitation size ice) are related to the occurrence of severe weather (large hail, strong winds or wind damage, tornadoes and funnel clouds) within one hour of the satellite observation time. During 1979 and 1980 over the United States there were 263 storms which had very cold 37 GHz signatures. Of these storms 15% were severe. The SMMR detected hail, wind, and tornadic storms equally well. Critical Success Indices (CSI's) of 0.32, 0.48, and 0.38 are achieved for the thresholding of severe vs. nonsevere low brightness temperature events during 1979, 1980, and the two years combined, respectively. Such scores are comparable to skill scores for early radar detection methods. These results suggest that a future geostationary passive microwave imaging capability at 37 GHz, with sufficient spatial and temporal resolution, would allow the detection of severe convective storms. This capability would provide a useful complement to radar, especially in areas not covered by radar.

Spencer, R. W.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Detector systems based on the high gain microchannel plate (MCP) electron multiplier were used extensively for imaging at soft X-ray wavelengths both on the ground and in space. The latest pulse counting electronic readout systems provide zero readout noise, spatial resolutions (FWHM) of 25 microns or better and can determine the arrival times of detected photons to an accuracy of the order of 100 ns. These systems can be developed to produce detectors with active areas of 100 nm in diameter or greater. The use of CsI photocathodes produces very high detective quantum efficiencies at wavelengths between about 100 and 1A (approximately 0.1 to 10 keV) with moderate energy resolution. The operating characteristics of the different types of soft X-ray MCP detector systems are described and the prospects for future developments are discussed.

Timothy, J. G.↗

Calculation of resolution for a windowless charge coupled device (CCD)-Digicon

A new version of an intensified charge-coupled device (ICCD) system, which is based on the incorporation of a CsI mesh photocathode and a thinned backside-illuminated CCD into a Space Telescope design Digicon tube, is being developed for future use in space-based observations in the Extreme Ultraviolet waveband. In this paper, a report is presented of the results of computer simulations involving the effects of the non-uniform electrostatic field near the mesh photocathode on imaging properties (especially, the spread function and modulation transfer function) of the detector system. The results are of importance in the design of the front end of the tube and the selection of optimum tube operating conditions. The overall resolution characteristics of the tube, including the effects of the mesh, the electron optics of the region between the mesh photocathode and the CCD target, and the structure of the CCD itself, are estimated.

Jia, X. Z.↗

An intensified photodiode array detector for space applications

The Hopkins Ultraviolet Telescope (HUT) is a general purpose moderate resolution spectrograph which is now being constructed for launch on the Space Shuttle. The instrument contains a Rowland spectrograph, which is located at the prime focus of a 0.9-m f/2 parabola. A description is given of the progress which has been made in the development of a flight detector for HUT. The detector developed is an intensified photodiode array. The image intensifier part of the detector contains two 25-mm 80:1, 12-micron pore microchannel plates (PCPs). A thin layer of CsI deposited on the front surface of the first microchannel plate has the objective to increase the quantum efficiency of the detector below 1850 A. The detector system utilizes a spectrometer processor (SP) which is based upon a bit-sliced microprocessor. The current status of the HUT detector system is discussed, and aspects of performance are evaluated. It is felt that the developed system will meet or exceed the design requirements.

Long, K. S.↗

Time dependent chemistry in dense molecular clouds. III - Infrared band cross sections of molecules in the solid state at 10 K

Thin film transmission infrared spectra and a list of integrated absorbance values (band strengths) of bands in the 2.5 to 20 micron range of various molecular solids deposited on a CsI window cooled to 10 K are presented. These solids include molecules known or suspected to be present on interstellar grains such as H2O, CO, NH3 and CH4 and mixtures of these molecules as well as various hydrocarbons. The method is described by which the absorbance values derived can be used to estimate column densities of species adsorbed on interstellar grains and other solids associated with celestial IR sources.

Dhendecourt, L. B.↗

The development and test of multi-anode microchannel array detector systems. Part 2: Soft X-ray detectors

Multi-Anode Microchannel Array (MAMA) detector systems with formats of 256 x 1024 pixels and active areas of 6 x 26 square mm are now under evaluation at visible, ultraviolet and soft x-ray wavelengths. Very-large-format versions of the MAMA detectors with formats of 2048 x 2048 pixels and active areas of 52 x 52 square mm are under development for use in the NASA Goddard Space Flight Center's Space Telescope Imaging Spectrograph (STIS). Open-structure versions of these detectors with CsI photocathodes can provide a high-resolution imaging capability at extreme ultraviolet (EUV) and soft x-ray wavelengths and can deliver a maximum count rate from each array in excess of 1 million counts s-1. In addition, these detector systems have the unique capability to determine the arrival time of a detected photon to an accuracy of 100 ns or better. The construction, mode-of-operation and performance characteristics of the MAMA detectors are described and the program for the development of the very-large-format detectors is outlined.

Timothy, J. G.↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗