Near-infrared mapping spectrometer optical subsystem development and testing

The Near-Infrared Mapping Spectrometer (NIMS) is one of the four remote-sensing science instruments of the Galileo Orbiter scientific payload. The NIMS scientific objectives require operating the detector and optical subsystem at cryogenic temperatures. The necessity of assembling, aligning, and testing the optics at room temperature and meeting design specifications at the cryogenic operating temperature (130 K) presented a set of challenging technical problems. A systematic approach to the development of athermalized mounts and supporting structures for optical components is described. A technique utilizing the visible spectral range and supplementary ray-trace information for alignment of an infrared instrument is presented. The optical subsystem point-spread function and spatial and spectral resolution were determined at room temperature using selected spectral and spatial targets. Based on thermal-distortion analyses of the structure and mounts, compensators were selected, implemented, and verified at cryogenic temperatures. The selection of the compensator and the overall system performance were verified in a thermal vacuum chamber. Various external and internal calibration targets were used.

Macenka, S. A.↗

High dynamic range infrared radiometry and imaging

The use is described of cryogenically cooled, extrinsic silicon infrared detectors in an unconventional mode of operation which offers an unusually large dynamic range. The system performs intensity-to-frequency conversion at the focal plane via simple circuits with very low power consumption. The incident IR intensity controls the repetition rate of short duration output pulses over a pulse rate dynamic range of about 10(6). Theory indicates the possibility of monotonic and approx. linear response over the full dynamic range. A comparison between the theoretical and the experimental results shows that the model provides a reasonably good description of experimental data. Some measurements of survivability with a very intense IR source were made on these devices and found to be very encouraging. Evidence continues to indicate that some variations in interpulse time intervals are deterministic rather than probabilistic.

Coon, Darryl D.↗

Spacelab qualified infrared imager for microgravity science applications

The Lewis Research Center is developing, under contract, a Spacelab (manned module in the Space Shuttle payload bay) qualified infrared imager for noncontact surface temperature measurement in the Surface Tension Driven Convection Experiment, a microgravity fluid physics experiment. A versatile design philosophy was used in order to provide other experiments with essentially an off the shelf Shuttle qualified instrument, eliminating the duplication of the rigorous development and flight qualification processes. An Inframetrics Model 600 Scanning Infrared Radiometer is being modified to satisfy both experimental and flight requirements, while maintaining the basic performance parameters of the commercial instrument. The modifications include an efficient, low power closed cycle cryogenic cooler to cool the detector, a ruggedized scanner mechanism, 8 bit A/D conversion, Mil-STD components (where possible), size and weight optimization, and the addition of a microprocessor to perform automatic gain control. Features such as detector spectral response, the addition of spectral filters, and target temperature ranges could easily be changed to make this instrument useful as both a qualitative and quantitative diagnostic tool for Spacelab microgravity experiments, in combustion and fluid physics.

Pline, Alexander D.↗

Characterization of AlMn TES Impedance, Noise, and Optical Efficiency in the First 150 mm Multichroic Array for Advanced ACTPol

The Advanced ACTPol (AdvACT) upgrade to the Atacama Cosmology Telescope features large arrays of multichroic pixels consisting of two orthogonal-polarization pairs of superconducting bolometers at two observing frequency bands. We present measurements of the detector properties and noise data in a subset of a fielded multichroic array of AlMn transition-edge sensor (TES) detectors. In this array, the distribution of critical temperature T(sub c) across detectors appears uniform at the percent level. The measured noise-equivalent power (NEP) distributions over approximately 1200 detectors are consistent with expectations. We find median NEPs of 4.0×10(exp −17) W/ √ Hz for low-band detectors and 6.2×10(exp −17) W/ √ Hz for high-band detectors under covered-window telescope test conditions with optical loading comparable to observing with precipitable water vapor approximately 0.5 mm. Lastly, we show the estimated detector optical efficiency, and demonstrate the ability to perform optical characterization over hundreds of detectors at once using a cryogenic blackbody source.

Crowley, Kevin T.↗

Use of Diffusion Bonded Cu Strap and Integrated MLI for Thermal Control of 100 K IR Detector on L’Ralph Instrument

Passive cooling of cryogenic instruments is one of the most challenging aspects of spaceflight thermal control systems. They are highly sensitive to parasitic heat leaks from their warmer environment, especially the spacecraft components. The L’Ralph instrument on the Lucy mission is an example of such a system, with its LEISA detector requiring passive cooling to temperatures below 112 K. MLI performance can be measured in terms of estar, and analysts apply bias between a high and low estar value. This approach works well for conventional MLI at room temperature, however, it can be dangerous when a mission goes through a wide range of temperatures during its lifetime, with estar values increasing exponentially as temperatures get colder. Various estar correlations are presented as well as how L’Ralph is approaching the MLI problem with the use of IMLI. IMLI uses discrete spacers to isolate each layer, and doesn’t require intermediate layers such as dacron netting. This results in estar performance that can be more precisely estimated, and yields valuesaround 0.004 at the 112K operating temperature. L’Ralph is using IMLI on the backside of the radiator, which permits a more effective use of increased radiator area, by minimizing the area dependent heat leak impact from the instrument backloading. The detector is thermally coupled to the radiator via a diffusion bonded Cu strap. The diffusion bonding process chemically bonds the Cu foil ends in order to maximize heat transfer effectiveness across the multiple foils used. Employing a pressure compensation design via the use of Ti blocks and a clamp at the strap ends ensures that as temperatures go colder, pre-load is maintained in order to minimize resistance at the strap ends. The use of both of these technologies, and how they work together are crucial to the success of the L’Ralph thermal control system.

Thermal↗

In-Flight Performance of the Soft X-Ray Spectrometer Detector System on ASTRO-H

The SXS instrument was launched aboard the Astro-H observatory on February 17, 2016. The SXS spectrometer is based on a high sensitivity x-ray calorimeter detector system that has been successfully deployed in many ground and sub-orbital spectrometers. The instrument was to provide essential diagnostics for nearly every class of x-ray emitting objects from the atmosphere of Jupiter to the outskirts of galaxy clusters, without degradation for spatially extended objects. The SXS detector system consisted of a 36-pixel cryogenic microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the detector system demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous band-pass from below 0.3 keV to above 12 keV with a timing precision better than 100 microsecond. In addition, a solid-state anti-coincidence detector was placed directly behind the detector array for background suppression. The detector error budget included the measured interference from the SXS cooling system and the spacecraft. Additional margin for on-orbit gain-stability, and on-orbit spacecraft interference were also included predicting an on-orbit performance that meets or exceeds the 7 eV FWHM at 6 keV requirement. The actual on-orbit spectral resolution was better than 5 eV FWHM at 6 keV, easily satisfying the instrument requirement. Here we discuss the actual on-orbit performance of the SXS detector system and compare this to performance in pre-flight testing and the on-orbit predictions. We will also discuss the on-orbit gain stability, additional on-orbit interference, and measurements of the on-orbit background.

X-ray astrophysics↗

Characterization of IRAS doped silicon detectors

Data are presented from a range of operating conditions which include background photo flux, operating temperature, and frequency. Each detector is equipped with a load resistor, a cryogenic field effect transistor preamplifier, and a temperature sensor. Data are also presented of detector signal, noise spectra, noise equivalent power, and spectral response.

Source record↗

Mechanical Design and Development of TES Bolometer Detector Arrays for the Advanced ACTPol Experiment

The next generation Advanced ACTPol (AdvACT) experiment is currently underway and will consist of four Transition Edge Sensor (TES) bolometer arrays, with three operating together, totaling 5800 detectors on the sky. Building on experience gained with the ACTPol detector arrays, AdvACT will utilize various new technologies, including 150 mm detector wafers equipped with multichroic pixels, allowing for a more densely packed focal plane. Each set of detectors includes a feedhorn array of stacked silicon wafers which form a spline pro le leading to each pixel. This is then followed by a waveguide interface plate, detector wafer, back short cavity plate, and backshort cap. Each array is housed in a custom designed structure manufactured from high purity copper and then gold plated. In addition to the detector array assembly, the array package also encloses cryogenic readout electronics. We present the full mechanical design of the AdvACT high frequency (HF) detector array package along with a detailed look at the detector array stack assemblies. This experiment will also make use of extensive hardware and software previously developed for ACT, which will be modi ed to incorporate the new AdvACT instruments. Therefore, we discuss the integration of all AdvACT arrays with pre-existing ACTPol infrastructure.

Advanced ACTPol (AdvACT)↗

Wide-range nuclear magnetic resonance detector

Compact and easy to use solid state nuclear magnetic resonance detector is designed for measuring field strength to 20 teslas in cryogenically cooled magnets. Extremely low noise and high sensitivity make detector applicable to nearly all types of analytical nuclear magnetic resonance measurements and can be used in high temperature and radiation environments.

Sturman, J. C.↗

Molecular and Elemental Dust Analyzer (MEDA) for the comet rendezvous asteroid flyby mission

Comets are some to the most primitive bodies in the solar system and therefore should contain elemental, chemical, and isotopic records of the early history of the solar system. An opportunity to perform in situ analyses of a comet nucleus exists with the Comet Rendezvous Asteroid Flyby (CRAF) mission. An integrated gas chromatograph/X-ray fluorescence instrument (MEDA), being proposed for inclusion onboard the CRAF spacecraft, will measure the molecular and elemental constituents of collected dust grains and ices. The gas chromatograph, employing helium ionization detectors and three columns designed to separate light gases, polar gases, and hydrocarbons will measure the volatile compounds of the biogenic elements thermally released from collected dust grains. The sensitivity of the GC for compounds of interest is at the picogram level. X-ray fluorescence utilized cryogenically cooled Si(Li) solid state detectors of nominal 150 eV resolution at 5.9 keV. Based on laboratory work with carbonaceous meteorites, both the GC and XRF can perform meaningful analyses with a few micrograms of collected comet dust.

Ohara, B. J.↗

Measurement of a high electrical quality factor in a niobium resonator for a gravitational radiation detector

The mechanical and electrical quality factors of a 10-g niobium resonator were measured at 4.4 K and were found to be 8.1 x 10 to the 6th, and 3.8 x 10 to the 6th, respectively. The value for the electrical quality factor is high enough for a system operating at 50 mK at a sensitivity level of one phonon. The resonator's low damping properties make it suitable for use as a transducer for a cryogenic three-mode gravitational radiation detector. A practical design is given for the mounting of the resonator on a 2400-kg aluminum-bar detector. Projections are made for the sensitivity of a 2400-kg bar instrumented as a three-mode system with this resonator inductively coupled to a SQUID.

Folkner, W. M.↗

Development of a long wavelength spectrometer for the 24-channel multispectral scanner: Instructions for installation, start-up, and adjustment

The basic information is presented, which is required for start-up and operation of two long-wavelength focal-plane and cooler assemblies, including the amplifiers and temperature control systems. The focal plane systems, referred to as the long wavelength spectrometer (LWS) were developed for direct replacement of Arrays 3 and 4 into the multispectral scanner presently being operated by the NASA Manned Spacecraft Center Facility, and Laboratory Support Branch. The equipment is comprised of two major sub-assemblies: Array 3 with three indium antimonide detector channels and Array 4 with seven mercury doped Germanium detector channels. Each array is mounted on a cryogenic cooler and includes the vacuum housings, mounting hardware (x, y, z translation and rotation stages) and detector signal conditioning, temperature control and monitoring electronics. The two arrays were designed to operate independently and do not share common equipment (viz power supplies, housings, mounts, etc.).

Source record↗

Microwave Kinetic Inductance Detector with Selective Polarization Coupling

A conventional low-noise detector requires a technique to both absorb incident power and convert it to an electrical signal at cryogenic temperatures. This innovation combines low-noise detector and readout functionality into one device while maintaining high absorption, controlled polarization sensitivity, and broadband detection capability. The resulting far-infrared detectors can be read out with a simple approach, which is compact and minimizes thermal loading. The proposed microwave kinetic inductance detector (MKID) consists of three basic elements. The first is the absorptive section in which the incident power is coupled to a superconducting resonator at far-infrared frequency above its superconducting critical frequency (where superconductor becomes normal conductor). This absorber's shape effectively absorbs signals in the desired polarization state and is resonant at the radio frequency (RF) used for readout of the device. Control over the metal film used in the absorber allows realization of structures with either a 50% broadband or 100% resonance absorptance over a 30% fractional bandwidth. The second element is a microwave resonator - which is realized from the thin metal films used to make the absorber as transmission lines - whose resonance frequency changes due to a variation in its kinetic inductance. The resonator's kinetic inductance is a function of the power absorbed by the device. A low-loss dielectric (mono-crystalline silicon) is used in a parallel-plate transmission line structure to realize the desired superconducting resonators. There is negligible coupling among the adjacent elements used to define the polarization sensitivity of each detector. The final component of the device is a microwave transmission line, which is coupled to the resonator, and allows detection of changes in resonance frequency for each detector in the focal plane array. The spiral shape of the detector's absorber allows incident power with two polarizations to couple to the detector equally. A stepped impedance resonator was used that allows the incident power absorbed in the detecting membrane area to be uniformly distributed in the detector's transmission line at the RF readout frequency. This maximizes the sensitivity of the detector. The signal is read out via a frequency multiplexing technique that requires a minimum number of interface transmission lines for readout. This reduces the packaging complexity and coupling to the device's thermal environment.

Wollack, Edward↗

256x256 switched-FET multiplexer for spaceborne astronomical applications

A novel cryogenic design of a source follower per detector (SFD) direct readout multiplexer is demonstrated. This design has proven to be a good prototype for the development of new low-noise large-area cryogenic multiplexers. In the absence of clocking noise, the readout demonstrates as low as about 30 electrons of rms read noise. There is still an excess noise component feeding through when the array is clocked, which manifests itself only at the lower temperatures. The shape of this component is dependent on a number of the bias voltages, and especially on the temperature of the chip. Analysis of the noise spectral density of the unit cell under various bias conditions shows that there is an excess spectral noise component at the lower temperatures.

Mcmurray, Robert E., Jr.↗

Limb Infrared Monitor of the Stratosphere /LIMS/ experiment

The Limb Infrared Monitor of the Stratosphere (LIMS) radiometer is a satellite-borne six-channel multispectral scanning radiometer using a two-stage methane and ammonia solid-cryogen cooler to cool the (Hg, Cd)Te focal plane to 65 K. The LIMS experiment employs thermal IR limb sounding to provide vertical-profile measurement of temperature and of concentrations of O3, NO3, and H2O in the stratosphere on a global scale. The goals of the experiment and the expected accuracies of the measurements are outlined, and the radiance measured by the radiometer is analyzed. A program of correlative measurements designed for verification and augmentation of the LIMS data is discussed. Detailed descriptions are given of the LIMS components and optics, the detector capsule assembly, the solid-cryogen cooler, the four operational modes of the LIMS system, and the data-processor electronics. It is noted that prelaunch acceptance testing thus far completed indicates that the LIMS specification design requirements have been met, and the experiment's performance goals can be achieved.

Drozewski, R. W.↗

The AstroBiology Explorer (ABE) MIDEX Mission Concept: Identifying Organic Molecules in Space

The Astrobiology Explorer (ABE) is a MIDEX mission concept, currently under Concept Phase A study at NASA's Ames Research Center in collaboration with Ball Aerospace & Technologies, Corp., and managed by NASA's Jet Propulsion Laboratory. ABE will conduct infrared spectroscopic observations to address important problems in astrobiology, astrochemistry, and astrophysics. The core observational program would make fundamental scientific progress in understanding the distribution, identity, and evolution of ices and organic matter in dense molecular clouds, young forming stellar systems, stellar outflows, the general diffuse ISM, HII regions, Solar System bodies, and external galaxies. The ABE instrument concept includes a 0.6 m aperture Ritchey-Chretien telescope and three moderate resolution (R = 2000-3000) spectrometers together covering the 2.5-20 micron spectral region. Large format (1024 x 1024 pixel) IR detector arrays will allow each spectrometer to cover an entire octave of spectral range per exposure without any moving parts. The telescope will be cooled below 50 K by a cryogenic dewar shielded by a sunshade. The detectors will be cooled to approx. 7.5 K by a solid hydrogen cryostat. The optimum orbital configuration for achieving the scientific objectives of the ABE mission is a low background, 1 AU Earth driftaway orbit requiring a Delta II launch vehicle. This configuration provides a low thermal background and allows adequate communications bandwidth and good access to the entire sky over the approx. 1.5 year mission lifetime.

Ennico, Kimberly↗

The Experiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM)

The EXperiment for Cryogenic Large-Aperture Intensity Mapping (EXCLAIM) is a high-altitude balloon telescope designed to deepen our understanding of star formation in a cosmological context, shedding light on why the star formation rate declines and breaks away from the cosmological evolution of dark matter for redshifts z>2 [1]. EXCLAIM will operate at 420–540 GHz with a spectral resolution of R=512 to measure the integrated line emission from galaxies and the intergalactic medium (IGM), in particular CO and [CII] line emissions from the nearby universe out to redshifts of z~3.5. This approach is known as Intensity Mapping (IM), which provides efficient access to large cosmological volumes and redshifts with sensitivity limited by detector noise or photon background, while requiring modest apertures. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (µ-Spec) with superconducting microwave kinetic inductance detectors (KIDs) in an all-cryogenic telescope (1.7 K) to achieve near background-limited sensitivity. Here, we present an overview of the EXCLAIM instrument and status, with emphasis on the Attitude Determination & Control System (ADCS) and the thermal system.

Giuseppe Cataldo↗