Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Configuration Management”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

The dependence of divertor power sharing on magnetic flux balance in near double-null configurations on Alcator C-Mod

Management of power exhaust will be a crucial task for tokamak fusion reactors. Reactor concepts are often proposed with double-null divertors, i.e. having two magnetic separatrices in an up-down symmetric configuration. This arrangement is potentially advantageous since the majority of the tokamak exhaust power tends to flow to the outer pair of divertor legs at large major radius, where the geometry is favorable for spreading the heat over a large surface area and there is more room for advanced divertor configurations. Despite the importance, there have been relatively few studies of divertor power sharing in near double null configurations and no studies at the poloidal magnetic fields and scrape-off layer power widths anticipated for a reactor. Motivated by this need we have undertaken a systematic study on Alcator C-Mod, examining the effect of magnetic flux balance on the power sharing among the four divertor legs in near double-null plasmas. Ohmic L-modes at three values of plasma current and ICRF-heated enhanced D-alpha (EDA) H-modes and I-modes at a single value of plasma current are explored, producing poloidal magnetic fields of 0.42, 0.62 and 0.85 Tesla. For Ohmic L-modes and ICRF-heated EDA H-modes, we find that the point of equal power sharing between upper and lower divertors occurs remarkably close to a balanced double null. Power sharing amongst the outer (upper versus lower) and inner (upper versus lower) pairs of divertors can be described in terms of a logistic function of magnetic flux balance, consistent with heat flux mapping along magnetic field lines to the outer midplane. Power sharing between inner and outer legs is found to follow a Gaussian-like function of magnetic flux balance with non-zero power to the inner divertors at double null. The overall behavior of H-modes operated near double null and for I-modes operating to within one heat flux e-folding of double null are found similar to Ohmic L-modes, with a significant reduction of power on the inner divertor legs. The results are encapsulated in terms of empirically-informed analytic functions of magnetic flux balance. When combined with magnetic equilibrium control system specifications, these relationships can be used to specify the power flux handling requirements for each of the four divertor target plates.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

L-Basin Microbial Monitoring Program - Evaluation of 20 Years of Monitoring

The SRNL L-Basin corrosion surveillance and microbial monitoring programs provide early detection and characterization of corrosion attack to the fuel and storage system materials resulting from prolonged exposure to the L-Basin water environment and of changes to and impact of the diverse microbial population, respectively. The early detection of corrosion allows for adjustment of the water quality, engineering management, and fuel storage configurations to mitigate excessive corrosion attack. While microbial influenced corrosion in L-Basin has not been detected, tracking and understanding the effect of microbial populations on the stored fuel and basin water will aid in identifying remedial measures to mitigate any detrimental impact. This report reviews the microbial monitoring activities since initial characterizations in the mid-1990s.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Automated Data Review of Analytical Laboratory Results at Los Alamos National Laboratory - 20299

Newport News Nuclear BWXT-Los Alamos, LLC (N3B) collects samples in support of the U.S. Department of Energy's (DOE) Office of Environmental Management (EM) Los Alamos Legacy Cleanup Contract (LLCC). N3B receives and reviews over 1.6 million sample data points annually in support of various ongoing environmental monitoring and remediation projects of the LLCC. N3B must demonstrate and document that reported external analytical laboratory data produced for the LLCC are of sufficient quality to fulfill their intended purpose and to support defensible decision making as described in EPA QA/G4 Guidance for the Data Quality Objectives Process 1994. In 2018, N3B assumed management of the LLCC along with the Environmental Information Management (EIM) database that contains all historical and current environmental data associated with the LLCC. The entire EIM database is shared between N3B, Triad National Security, LLC (Triad), and New Mexico Environment Department (NMED). These three parties jointly manage the database, its configuration, and changes / updates. All environmental data that are entered into EIM are updated and available, on a daily basis, in the linked public database Intellus New Mexico (Intellus). The quality and defensibility of the environmental data generated from sampling activities is a key component of an effective remediation process. Providing quality data is accomplished through a data assessment process that includes examination, verification, and validation. Examination is the assessment of completeness of the deliverables, identification of any reporting errors, and determining the usability of the data based on the laboratory's evaluation of its data as described in the case narrative received with the data. Verification consists of an evaluation of the Electronic Data Deliverables (EDD) data report to determine the extent to which the external analytical laboratories met method and contract-specific quality control and reporting requirements. Validation consists of determining the data quality and the extent to which the external analytical laboratories accurately and completely reported all sample and quality control results and satisfied all contract requirements. EIM contains an automatic Data Validation Module which performs automated data review (DVM ADR). DVM ADR is a tool to assist in the validation process. When DVM ADR is used in conjunction with manual examination of sample data packages, the combination of the two will meet and exceed the requirements of verification. N3B recognized an opportunity for process improvement, focusing on DVM ADR configuration and enhancements in EIM. Testing EIM's configuration provided proof of the DVM ADR's capabilities and flexibility to accurately perform routine data checks based on analytical methods and regulatory requirements. In addition, the DVM ADR module was improved through enhancements for all analytes, particularly upgrades for radiochemistry data. Extensive testing of the DVM ADR module occurred using EDDs from actual laboratory analyses on the EIM testing site. During this process, N3B manipulated EDD information to verify that the actual outcomes matched the expected outcomes. The results of this testing were shared with the database architects, and configuration improvements were identified to address these results. During this process, N3B identified that the radiochemical DVM ADR capabilities were underutilized, and so enhanced the DVM ADR functionality with respect to radioanalytical assessment. N3B environmental data uploads to Intellus on a daily basis from EIM, once the analytical data undergoes examination and verification. As such, it is important to have a high level of confidence in the quality and defensibility of the data. The process of manual examination, along with the DVM ADR, in conjunction with full validation of a percentage the data specified through the Data Quality Objectives greatly increases efficiency of data review and confidence level of the quality of the data, and gives the project managers, governmental offices, and the public expedited access to high-quality data. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Power system restoration incorporating diverse distributed energy resources

An example system includes an aggregator configured to receive a service collaboration request and iteratively determine, based on minimum and maximum power values for DERs under its management, an optimized operation schedule. The aggregator may also be configured to iteratively determine, based on the optimized operation schedule, an estimated flexibility range for devices under its management and output an indication thereof. The system may also include a power management unit (PMU) configured to iteratively receive the indication and determine, based on a network model that includes the estimated flexibility range, a reconfiguration plan and an overall optimized operation schedule for the network. The PMU may also be configured to iteratively cause reconfiguration of the network based on the plan. The PMU and aggregator may also be configured to iteratively, at a fast timescale, cause energy resources under their management to modify operation based on the overall optimized operation schedule.

Ding, Fei↗

Web Proxy Auto Discovery for the WLCG

All four of the LHC experiments depend on web proxies (that is, squids) at each grid site to support software distribution by the CernVM FileSystem (CVMFS). CMS and ATLAS also use web proxies for conditions data distributed through the Frontier Distributed Database caching system. ATLAS & CMS each have their own methods for their grid jobs to find out which web proxies to use for Frontier at each site, and CVMFS has a third method. Those diverse methods limit usability and flexibility, particularly for opportunistic use cases, where an experiment’s jobs are run at sites that do not primarily support that experiment. This paper describes a new Worldwide LHC Computing Grid (WLCG) system for discovering the addresses of web proxies. The system is based on an internet standard called Web Proxy Auto Discovery (WPAD). WPAD is in turn based on another standard called Proxy Auto Configuration (PAC). Both the Frontier and CVMFS clients support this standard. The input into the WLCG system comes from squids registered in the ATLAS Grid Information System (AGIS) and CMS SITECONF files, cross-checked with squids registered by sites in the Grid Configuration Database (GOCDB) and the OSG Information Management (OIM) system, and combined with some exceptions manually configured by people from ATLAS and CMS who operate WLCG Squid monitoring. WPAD servers at CERN respond to http requests from grid nodes all over the world with a PAC file that lists available web proxies, based on IP addresses matched from a database that contains the IP address ranges registered to organizations. Large grid sites are encouraged to supply their own WPAD web servers for more flexibility, to avoid being affected by short term long distance network outages, and to offload the WLCG WPAD servers at CERN. The CERN WPAD servers additionally support requests from jobs running at non-grid sites (particularly for LHC@Home) which it directs to the nearest publicly accessible web proxy servers. Furthermore, the responses to those requests are geographically ordered based on a separate database that maps IP addresses to longitude and latitude.

97 MATHEMATICS AND COMPUTING↗

Experimental investigation of a closed vapour box module for a divertor-like configuration in Magnum-PSI

Efficient management of extreme heat fluxes in the divertor region to extend the lifetime of the components remains a critical challenge for the realization of nuclear fusion-based power plants. Among the alternative concepts explored for the divertor region, the use of liquid metals, particularly lithium, is of interest due its ability to dissipate the incoming plasma heat flux through the vapour shielding effect (VS). In this work, we experimentally investigated a ‘closed’ configuration of a dedicated Vapour Box Module (VBM) in the linear plasma device Magnum-PSI. The goal of the experiments is to simulate the vapour box divertor environment conditions and assess its performance in terms of power mitigation and redistribution and lithium confinement. Initial testing without Li demonstrated the efficacy of a closed VBM structure in inducing detachment via neutral gas accumulation. Apertures which enabled non-condensing gas to be effectively pumped while ensuring lithium condensed on the inner surfaces were therefore added. With a lithium capillary porous structure target used, lithium is directly vaporized by the plasma, forming a dense lithium vapour cloud that interacts with the incoming plasma. This resulted in a significant reduction of the target temperature of at least 48%, together with a temperature locking effect, a phenomenon typically observed in the VS regime. Lithium vapour confinement within the VBM was strongly correlated with the wall temperature. Relatively cold walls promoted Li re-condensation and therefore improved Li confinement, although with the expected trade-off of increased hydrogenic retention on lithium-wetted surfaces. As the wall temperature increased, the confinement efficiency decreased, consistent with reduced Li re-condensation and thermally activated Li–H chemistry and remobilization at the walls. Diagnostic measurements through embedded thermocouples and calorimetry revealed that lithium vaporization and re-condensation processes also playedsignificant roles in plasma power dissipation. The results advance the case for a closed divertor chamber with direct lithium evaporation from the strike-points as a viable method to manage divertor heat fluxes in future fusion reactors.

Romano, Fabio [Dutch Institute for Fundamental Ene↗

A step towards the final frontier: Lessons learned from acceptance testing of the first HPE/Cray EX 3000 system at ORNL

Summary In this article, we summarize the deployment of the Air Force Weather (AFW) HPC11 system at Oak Ridge National Laboratory (ORNL) including the process followed to successfully complete acceptance testing of the system. HPC11 is the first HPE/Cray EX 3000 system that has been successfully released to its user community in a federal facility. HPC11 consists of two identical 800‐node supercomputers, Fawbush and Miller, with access to two independent and identical lustre parallel file systems. HPC11 is equipped with Slingshot 10 interconnect technology and relies on the HPE Performance Cluster Manager software for system configuration. ORNL has a clearly defined acceptance testing process used to ensure that every new system deployed can provide the necessary capabilities to support user workloads. We worked closely with HPE and AFW to develop a set of tests that used the United Kingdom's Meteorological Office's Unified Model and 4‐dimensional variational data assimilation. We also included benchmarks and applications from the Oak Ridge Leadership Computing Facility portfolio to fully exercise the HPE/Cray programming environment and evaluate the functionality and performance of the system. Acceptance testing of HPC11 required parallel execution of each element on Fawbush and Miller. In addition, careful coordination was needed to ensure successful acceptance of the newly deployed lustre file systems alongside the compute resources. In this work, we present test results from specific system components and provide an overview of the issues identified, challenges encountered, and the lessons learned along the way.

Melesse Vergara, Verónica G.↗

Constellation: The autonomous control and data acquisition system for dynamic experimental setups

The operation of instruments and detectors in laboratory or beamline environments presents a complex challenge, requiring stable operation of multiple concurrent devices, often controlled by separate hardware and software solutions. These environments frequently undergo modifications, such as the inclusion of different auxiliary devices depending on the experiment or facility, adding further complexity. The successful management of such dynamic configurations demands a flexible and robust system capable of controlling data acquisition, monitoring experimental setups, enabling seamless reconfiguration, and integrating new devices with limited effort. This paper presents Constellation, a flexible and network-distributed control and data acquisition software framework tailored to laboratory and beamline environments, that addresses the limitations of existing solutions. The framework is designed with a focus on extensibility, providing a streamlined interface for instrument integration. It supports efficient system setup via network discovery mechanisms, promotes stability through autonomous operational features, and provides comprehensive documentation and supporting tools for operators and application developers such as controllers and logging interfaces. At the core of the architectural design is the autonomy of the individual components, called satellites, which can make independent decisions about their operation and communicate these decisions to other components. This paper introduces the design principles and framework architecture of Constellation, presents the available graphical user interfaces, shares insights from initial successful deployments, and provides an outlook on future developments and applications.

Autonomy↗

A Survey of Recent Advances in Transmission Network Switching

Optimal Transmission Switching for electric power networks is a research topic of great interest for both researchers and electric power engineers. Transmission switching is commonly considered a corrective mechanism tool for overloaded networks; however in recent years it has been sought as a means to reduce power loss in the network. Ultimately the objective of this analysis is to provide smart tools for power and economic dispatch planning, allowing utilities and engineers to utilize existing infrastructure as a means of automatic control. The optimization problem is a complex multi-objective search including criteria such as system power loss, equality/non-equality constraints, islanding management, and radial topology configuration in the case of distribution networks. Many optimization methods have been adopted for the transmission switching problem in past years using various heuristic search algorithms. The scope of methodology extends from tried and true methods such as simulated annealing to more modern methods like neural network optimization. Solution benchmarks under consideration commonly include solution state accuracy, computational burden and solution time. The objective of this presentation is to provide a comprehensive account of development in transmission switching methodologies. Benchmarking and testing strategies will be discussed as well as application of the Transmission Expansion Planning Tool in finding transmission switching solutions. Limited Discrepancy Search (LOS) and Probe Discrepancy Search (PDS) Algorithms are compared with more classic optimization strategies, as seen in defining literature and publications in this research field.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Ready, Flexible Large Power Transformer

GE Research and its partner Prolec GE have proposed a novel and breakthrough concept to improve the flexibility and interchangeability of large power transformers (LPTs). LPTs refer in this report to transformers with a power rating equal or greater than 100 MVA. The concept consists of a 3-phase autotransformer bank having one specified high voltage side (HV) voltage and three configurable low voltage side (LV) voltage taps. Moreover, the leakage impedance is adjustable offline using taps which allows to accommodate short-circuit requirements for a wide range of LPTs applications. The research performed aimed to develop and validate a cost-effective design of a flexible LPT and to demonstrate its competitiveness with the LPT fleet currently in operation in the U.S. The concept is intended for the long-term replacement of existing LPTs. In this project, the U.S based population of LPTs was analyzed to determine their commonality in power, voltage classes, and impedance range. Up to 9,700 units, currently deployed in the NERC’s Eastern and Western interconnection regions, were evaluated. This analysis yielded the specifications of two flexible LPTs to be designed to demonstrate the manufacturability and competitiveness of the concept: a 345 kV, 230 MVA and a 230 kV, 100 MVA LPTs. The two LPTs are both configurable to 161 kV, 138 kV, and 115 kV on the LV side and allow leakage impedance variation between 4% and 14%. The design output showed that the flexible LPT is manufacturable and competitive with conventional LPT. The proposed design has a power efficiency of 99.5% and a total active part weight increase ranging only between 15% and 28% relative to conventional LPTs it can be substituted with. Indeed, for the flexible LPT, the higher the LV side voltage is, the higher is its power rating. Hence, flexible LPTs are more competitive when compared with the largest conventional LPT they can replace. Power systems analyses were carried out to evaluate the performance of the flexible LPT when replacing an existing conventional LPT. These analyses showed that short-circuit and inrush currents will remain respectively within 15% and 9.4% of their original levels suggesting that no substations equipment is likely to be replaced due the installation of the flexible LPT. In addition, the analyses showed that the transient overvoltage anticipated at the impedance configuration switch will be manageable and will not pose any particular risk during lightning or switching events. This research proved that the deployment of flexible LPTs in the U.S power grid can greatly improve the grid reliability and its resiliency especially in the event of the loss of multiple LPTs. Moreover, the concept can significantly help reduce LPTs’ spare inventory by providing a high spare coverage level. The performed analysis showed that the designed 345 kV flexible LPT can serve as a spare for up to 34 units currently in operation in the U.S while the designed 230 kV flexible LPT can replace up to 101 units. Flexible LPTs offer new opportunities to U.S utilities to improve interchangeability of LPTs in the transmission system and to better strategize the upcoming renewal of about 70% of the population of LPTs anticipated to retire within the next two decades.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Lighting system with thermal management system having point contact synthetic jets

Lighting system having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.

42 ENGINEERING↗

Lighting system with thermal management system having point contact synthetic jets

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.

36 MATERIALS SCIENCE↗

Lighting system with thermal management system having point contact synthetic jets

Lighting systems having unique configurations are provided. For instance, the lighting system may include a light source, a thermal management system and driver electronics, each contained within a housing structure. The light source is configured to provide illumination visible through an opening in the housing structure. The thermal management system includes a plurality of synthetic jets. The synthetic jets are arranged within the lighting system such that they are secured at contact points.

36 MATERIALS SCIENCE↗

FRMAC Laboratory Analysis RadResponder Gap Analysis and Web Portal Enhancements

The Federal Radiological Monitoring and Assessment Center (FRMAC) relies on accurate and defensible analytical laboratory data to support its mission. FRMAC Laboratory Analysis personnel are responsible for (1) receiving samples, (2) managing samples, and (3) providing data quality assurance. Currently, the RadResponder software application does not meet all these needs. With some modifications, RadResponder could meet the needs for sample receiving functions, but it does not meet the needs of sample management and data quality assurance functions. The FRMAC Laboratory Analysis team has discussed and reviewed the following options moving forward: Option 1: Make minor revisions to RadResponder to improve sample receiving capability, purchase and configure a commercial laboratory information management system (LIMS) to perform sample management and data quality assurance, and build an interface between RadResponder and the commercial-off-the-shelf LIMS. Option 2: Make major revisions to RadResponder for all FRMAC Laboratory Analysis functions to support required sample management and data quality assurance activities. Option 3: Create a custom-built LIMS system to interface with RadResponder. Note: All three options will require the development of a Laboratory Analysis web portal and will require funding for ongoing maintenance and training. The FRMAC Laboratory Analysis team highly recommends Option 1 as the best and most efficient path forward. Commercial-off-the-shelf LIMS products have been proven successful in the laboratory community for decades. Option 1 leverages these proven technologies and takes advantage of RadResponder's current strengths.

61 RADIATION PROTECTION AND DOSIMETRY↗

Grid Cyber-Security Strategy in an Attacker-Defender Model

The progression of cyber-attacks on the cyber-physical system is analyzed by the Probabilistic, Learning Attacker, and Dynamic Defender (PLADD) model. Although our research does apply to all cyber-physical systems, we focus on power grid infrastructure. The PLADD model evaluates the effectiveness of moving target defense (MTD) techniques. We consider the power grid attack scenarios in the AND configurations and OR configurations. In addition, we consider, for the first time ever, power grid attack scenarios involving both AND configurations and OR configurations simultaneously. Cyber-security managers can use the strategy introduced in this manuscript to optimize their defense strategies. Specifically, our research provides insight into when to reset access controls (such as passwords, internet protocol addresses, and session keys), to minimize the probability of a successful attack. Our mathematical proof for the OR configuration of multiple PLADD games shows that it is best if all access controls are reset simultaneously. For the AND configuration, our mathematical proof shows that it is best (in terms of minimizing the attacker's average probability of success) that the resets are equally spaced apart. We introduce a novel concept called hierarchical parallel PLADD system to cover additional attack scenarios that require combinations of AND and OR configurations.

97 MATHEMATICS AND COMPUTING↗

Ecological forecasts for marine resource management during climate extremes

Forecasting weather has become commonplace, but as society faces novel and uncertain environmental conditions there is a critical need to forecast ecology. Forewarning of ecosystem conditions during climate extremes can support proactive decision-making, yet applications of ecological forecasts are still limited. We showcase the capacity for existing marine management tools to transition to a forecasting configuration and provide skilful ecological forecasts up to 12 months in advance. The management tools use ocean temperature anomalies to help mitigate whale entanglements and sea turtle bycatch, and we show that forecasts can forewarn of human-wildlife interactions caused by unprecedented climate extremes. We further show that regionally downscaled forecasts are not a necessity for ecological forecasting and can be less skilful than global forecasts if they have fewer ensemble members. Our results highlight capacity for ecological forecasts to be explored for regions without the infrastructure or capacity to regionally downscale, ultimately helping to improve marine resource management and climate adaptation globally.

54 ENVIRONMENTAL SCIENCES↗

Thermal Management of Power Semiconductor Packages - Matching Cooling Technologies with Packaging Technologies (Presentation)

Heat removal for power semiconductor devices is critical for robust operation. Because there are different packaging options, different thermal management technologies, and a range of applications, there is a need for a methodology to match cooling technologies and package configurations to target applications. To meet this need, a methodology was developed to compare the sensitivity of coolingtechnologies on the overall package thermal performance over a range of power semiconductor packaging configurations. The results provide insight into the trade-offs associated with cooling technologies and package configurations. The approach provides a method for comparing new developments in power semiconductor packages and identifying potential thermal control technologies for the package.The results can help users select the appropriate combination of packaging configuration and cooling technology for the desired application.

30 DIRECT ENERGY CONVERSION↗