Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Condensation Particle Counter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Condensation-nuclei (Aitken Particle) measurement system used in NASA global atmospheric sampling program

The condensation-nuclei (Aitken particle) measuring system used in the NASA Global Atmospheric Sampling Program is described. Included in the paper is a description of the condensation-nuclei monitor sensor, the pressurization system, and the Pollack-counter calibration system used to support the CN measurement. The monitor has a measurement range to 1000 CN/cm cubed and a noise level equivalent to 5 CN/cm cubed at flight altitudes between 6 and 13 km.

Nyland, T. W.↗

EPCAPE-PT-LANL Measurements: Cloud Condensation Nuclei Counter

Coastal cities offer a unique environment for studying aerosol-cloud interactions and the effects of urban emissions on cloud properties. As part of the Eastern Pacific Cloud Aerosol Precipitation Experiment (EPCAPE), the Partitioning Thrust by Los Alamos National Laboratory (EPCAPE-PT-LANL) was conducted. Our campaign focused on measuring the optical and chemical properties of aerosols and their interactions within marine stratocumulus clouds in La Jolla, California. EPCAPE-PT-LANL enhances the primary goals of EPCAPE through innovative observations of vapor-phase transitions between aerosols and cloud droplets, the impact of black carbon on aerosol-cloud dynamics, and the effects of cloud processing on aerosol optical properties. Instrument: Cloud Condensation Nuclei Counter, single column (Droplet Measurements Technology) Files: data_10sec_CCNc.csv, data_10min_CCNc.csv Header: - SuperSaturation[unitless]: The level of supersaturation, expressed as a unitless percentage, at which cloud condensation nuclei (CCN) activity is measured. - NumberConcentration[/cm3]: Number concentration of particles acting as CCN at the baseline supersaturation level, measured in particles per cubic centimeter. - NumberConcentration_SS2[/cm3]: Number concentration of particles acting as CCN at a supersaturation level of 0.2%, measured in particles per cubic centimeter. - NumberConcentration_SS4[/cm3]: Number concentration of particles acting as CCN at a supersaturation level of 0.4%, measured in particles per cubic centimeter. - QualityControl_Flag[bool]: A boolean flag indicating whether the data point passed quality control checks. - CVI_Flag[bool]: A boolean flag indicating whether the Counterflow Virtual Impactor (CVI) was active (true) or inactive (false) during the measurement.

54 ENVIRONMENTAL SCIENCES↗

In situ measurements of particulate number density and size distribution from an aircraft

Two different commercial particulate measuring instruments were flown aboard the NASA Convair 990. A condensation nuclei monitor was utilized to measure particles larger than approximately 0.003 micron in diameter. A specially designed pressurization system was used with this monitor at cabin altitude pressure. A near-forward light scattering counter was used to measure the number and size distribution particles in the size range from 0.5 to 5 microns and greater in diameter. Considerable variation in number density was encountered for both classes of particles at the test altitudes ranging from 5 to 12 km. Presence of clouds could be detected by the light scattering instrument because large numbers of particles would then be registered by the instrument, especially in the size range above 5.0 microns in diameter.

Briehl, D.↗

CCN Measurements at Urban Site during CoURAGE

Cloud condensation nuclei (CCN) measurements were collected during CoURAGE from March - June 2025 at the BSEC urban atmospheric chemistry supersite (39.32057 N, 76.6246 W). CCN number concentrations (# cm-3) were obtained at a frequency of 1 second using a cloud condensation nuclei counter (CCN-100, Droplet Measurement Technologies). The CCN counter was operated in stepping mode, measuring CCN over a range of supersaturations from 0.2 to 1.0%. The settings of the instrument were set such that the supersaturation increased in increments of 0.2% up to the maximum supersaturation, and then decreased in increments of 0.2% down to the minimum supersaturation in a repeating cycle. The supersaturation of the instrument was calibrated weekly using ammonium sulfate. The weekly calibrated supersaturation values have been applied to the data. Data during transitions between supersaturation values were removed and replaced with a value of -999. Transitions are defined as the first 210 seconds after a new supersaturation value to ensure the instrument has stabilized following a change in supersaturation. Data were also flagged with a value of -999 if there were concerns with the function of the instrument, specifically the presence of alarm codes, fogging of the optical particle counter (1st stage monitor > 0.4 V), or a sheath to sample flow ratio outside the expected range (< 9 or > 11).

CCN number density↗

A case of type I polar stratospheric cloud formation by heterogeneous nucleation

The NASA ER-2 aircraft flew on January 24, 1989, from Stavanger to Spitsbergen, Norway, at the 430-440 K potential temperature surface (19.2-19.8 km pressure altitude). Aerosols were sampled continuously by an optical particle counter (PMS-FSSP300) for concentration and size analyses, and during five 10-min intervals by four wire and one replicator impactor for concentration, size, composition, and phase analysis. During sampling, the air saturation of H2O with respect to ice changed from 20 to 100 percent, and of HNO3 with respect to nitric acid trihydrate (NAT) from subsaturation to supersaturation. Data from both instruments indicate a condensation of hydrochloric acid and, later, nitric acid on the background aerosol particles as the ambient temperature decreases along the flight track. This heterogeneous nucleation mechanism generates type I polar stratospheric cloud particles of 10-fold enhanced optical depth, which could play a role in stratospheric ozone depletion.

Pueschel, R. F.↗

Measurements in polar stratospheric clouds over Antarctica in September 1989

The results of six balloon flights at McMurdo Station, Antarctica, under varying temperature conditions, are used in a study of polar stratospheric clouds during Sept. 1989. A particle counter, with size resolution in the 0.5 micron radius region, indicates that cloud size distributions are always bimodal. Mode radii ranging from 0.05 to 0.10 microns were observed for the small particle mode, representing the sulfate layer or condensational growth enhancements of it. The data are not inconsistent with the expected increase in size with decreasing temperature of the small particle mode in the sulfate layer owing to deliquescence although this phenomenon is often masked by nitric acid trihydrate (NAT) condensation when temperatures are sufficiently low. Mode radii generally ranged from 1.5 to 3.5 micron for the large particle mode at concentrations 3 to 4 orders of magnitude lower than the small particle mode. The large particle mode, which normally comprises most of the mass, is presumably caused by NAT condensation on larger particles of the sulfate layer and indicates HNO3 mixing ratios of 1 to 5 ppbv for most of the cloud layers observed, suggesting substantial denitrification. On several occasions, distributions were observed with mode radii as high as 7 microns, and correspondingly large inferred mass, indicating water ice clouds in the 12 to 15 km region. On other occasions, absence of such clouds at very low temperatures indicated water vapor mixing ratios of less than 3 ppmv suggesting dehydration. Generally, the inferred HNO3 mixing ratios were higher in the lower stratosphere, suggesting redistribution through particle sedimentation.

Deshler, Terry↗

The role of ions in new particle formation in the CLOUD chamber

The formation of secondary particles in the atmosphere accounts for more than half of global cloud condensation nuclei. Experiments at the CERN CLOUD (Cosmics Leaving OUtdoor Droplets) chamber have underlined the importance of ions for new particle formation, but quantifying their effect in the atmosphere remains challenging. By using a novel instrument setup consisting of two nanoparticle counters, one of them equipped with an ion filter, we were able to further investigate the ion-related mechanisms of new particle formation. In autumn 2015, we carried out experiments at CLOUD on four systems of different chemical compositions involving monoterpenes, sulfuric acid, nitrogen oxides, and ammonia. We measured the influence of ions on the nucleation rates under precisely controlled and atmospherically relevant conditions. Our results indicate that ions enhance the nucleation process when the charge is necessary to stabilize newly formed clusters, i.e., in conditions in which neutral clusters are unstable. For charged clusters that were formed by ion-induced nucleation, we were able to measure, for the first time, their progressive neutralization due to recombination with oppositely charged ions. A large fraction of the clusters carried a charge at 1.5 nm diameter. However, depending on particle growth rates and ion concentrations, charged clusters were largely neutralized by ion–ion recombination before they grew to 2.5 nm. At this size, more than 90 % of particles were neutral. In other words, particles may originate from ion-induced nucleation, although they are neutral upon detection at diameters larger than 2.5 nm. Observations at Hyytiälä, Finland, showed lower ion concentrations and a lower contribution of ion-induced nucleation than measured at CLOUD under similar conditions. Although this can be partly explained by the observation that ion-induced fractions decrease towards lower ion concentrations, further investigations are needed to resolve the origin of the discrepancy.

54 ENVIRONMENTAL SCIENCES↗

Mixing-height measurement by lidar, particle counter, and rawinsonde in the Williamette Valley, Oregon

The feasibility of using laser radar (lidar) to measure the spatial distribution of aerosols and water vapor in the earth's mixing or boundary layer is shown. From these data the important parameter of actual mixing height was determined, that is, the maximum height to which particulate pollutants actually mix. Data are shown for simultaneous lidar, rawinsonde, and aircraft-mounted condensation nuclei counter and temperature measurements. The synoptic meteorology is also presented. The Williamette Valley, Oregon, was chosen for the measurements because of its unique combination of meteorology, terrain, and pollutant source, along with an ongoing Oregon State University study of the natural ventilation of this valley.

Mccormick, M. P.↗

Unusual behavior in the condensation nuclei concentration at 30 km

The result obtained with an improved balloon-borne condensation nuclei (CN) counter that is capable of operating to altitudes of at least 30 km are presented. Of major interest is the appearance of a quasiannual variation near 30 km which could be described by a sudden concentration increase of unusually small particles occurring in the winter or spring followed by a 1- to 3-month decay period to background levels. The magnitude of the variation has increased dramatically following the recent generally high levels of volcanic activity affecting the lower stratosphere. Several potential explanations for the event are considered, but none appear entirely satisfactory or complete at the present time. The explanation with the fewest drawbacks would attribute the production of growth of the new cn to a highly supersaturated H2SO4 vapor layer generated by any one of several proposed processes in the upper high latitude stratosphere.

Rosen, J. M.↗

Preliminary investigation of a water-based method for fast integrating mobility spectrometry

A water-based condensational growth channel was developed for imaging mobility-separated particles within a parallel plate separation channel of the Fast Integrated Mobility Spectrometer (FIMS). Reported are initial tests of that system, in which the alcohol condenser of the FIMS was replaced by a water-based condensational growth channel. Tests with monodispersed sodium chloride aerosol verify that the water-condensational growth maintained the laminar flow, while providing sufficient growth for particle imaging. Particle positions mapped onto particle mobility, in accordance with theoretical expectations. Particles ranging in size from 12 nm to 100 nm were counted with the same efficiency as with a butanol-based ultrafine particle counter, once inlet and line losses were taken into account.

54 ENVIRONMENTAL SCIENCES↗

62°S Witnesses the Transition of Boundary Layer Marine Aerosol Pattern Over the Southern Ocean (50°S–68°S, 63°E– 150°E) During the Spring and Summer: Results From MARCUS (I)

The Atmospheric Radiation Measurement Mobile Facility-2 was installed onboard the research vessel Aurora Australis to measure aerosol properties during the 2017-2018 Measurement of Aerosols, Radiation, and CloUds over the pristine Southern ocean (MARCUS) Experiment, providing unique data on aerosols latitudinal and seasonal variation, including south of 60 degrees S where previous observations are scarce. Data from a Cloud Condensation Nuclei (CCN) counter and Ultra-High-Sensitivity Aerosol Spectrometer show that both the number concentration (N-CCN) and size distribution of CCN-active aerosols, with diameters (D) between 60 nm < D < 1,000 nm are different over the North Southern Ocean (NSO) (50 degrees S-60 degrees S) and the South Southern Ocean (SSO) (62 degrees S-68 degrees S). The average NSO N-CCN at 0.2% and 0.5% supersaturation were 28% and 49% less than that over the SSO. This increase of CCN over the SSO is caused by the increase of aerosols with 60 nm < D < 200 nm, consistent with calculations of Aerosol Scattering Angstrom Exponents derived from a nephelometer. Aerosol hygroscopicity growth factor measured by the Hygroscopic Tandem Differential Mobility Analyzer stayed close to 1.41 for aerosols with 50 nm < D < 250 nm over the SSO, but increased from 1.30 to 1.67 over the NSO, indicating different chemical compositions. Both CCN and Ice Nucleating Particles (INPs) showed a stronger variation with season than with latitude. The variation of heat-labile and presumably proteinacous INPs suggests an increase of ice nucleating-active microbes in summer.

Niu, Qing↗

A new technique to retrieve aerosol vertical profiles using micropulse lidar and ground-based aerosol measurements

Accurately characterizing the vertical distribution of aerosols and their cloud-forming properties is crucial for understanding aerosol-cloud interactions and their impact on climate. This study presents a novel technique for retrieving vertical profiles of aerosols, cloud condensation nuclei (CCN), and ice nucleating particles (INP) by combining micropulse lidar, radiosonde, and ground-based aerosol measurements. Herein, the technique is applied to data collected by our team at Texas A&M University during the Tracking Aerosol Convection Interactions ExpeRiment (TRACER) campaign. Ground-based aerosol size distribution and CCN counter data are used to estimate the value of the aerosol hygroscopicity parameter, κ. The derived κ, together with Mie scattering theory and the relative humidity profile from the radiosonde, is used to estimate aerosol size growth and the associated increase in backscatter at each altitude. We then correct the lidar backscatter to dry conditions to produce the dry aerosol backscatter coefficient profile. The dry aerosol backscatter coefficient profile is linearly scaled to collocated surface measurements of aerosols, CCN, and INP to produce corresponding vertical profiles. Combining lidar backscatter profiles with aerosol and cloud nucleation measurements leads to a more realistic representation of vertical distributions of aerosol properties. The method could be readily applied to lidar measurements in future field campaigns.

Chen, Bo [Texas A & M Univ., College Station, TX (↗

Temperature Dependence in Homogeneous and Heterogeneous Nucleation

Heterogeneous nucleation on stable (sub-2 nm) nuclei aids the formation of atmospheric cloud condensation nuclei (CCN) by circumventing or reducing vapor pressure barriers that would otherwise limit condensation and new particle growth. Aerosol and cloud formation depend largely on the interaction between a condensing liquid and the nucleating site. A new paper published this year reports the first direct experimental determination of contact angles as well as contact line curvature and other geometric properties of a spherical cap nucleus at nanometer scale using measurements from the Vienna Size Analyzing Nucleus Counter (SANC) (Winkler et al., 2016). For water nucleating heterogeneously on silver oxide nanoparticles we find contact angles around 15 degrees compared to around 90 degrees for the macroscopically measured equilibrium angle for water on bulk silver. The small microscopic contact angles can be attributed via the generalized Young equation to a negative line tension that becomes increasingly dominant with increasing curvature of the contact line. These results enable a consistent theoretical description of heterogeneous nucleation and provide firm insight to the wetting of nanosized objects.

54 ENVIRONMENTAL SCIENCES↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic capability of the filter reduced the efficiency of challenging particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test.

61 RADIATION PROTECTION AND DOSIMETRY↗

Development of a fast scintillator based beam phase measurement system for compact superconducting cyclotrons

In an isochronous cyclotron, measurements of central phase of the ion beam with respect to rf and the phase width provide a way to tune the cyclotron for maximum energy gain per turn and efficient extraction. We report here the development of a phase measurement system and the measurements carried out at the Variable Energy Cyclotron Centre's (VECC's) K= 500 superconducting cyclotron. The technique comprises detecting prompt {gamma}-rays resulting from the interaction of cyclotron ion beam with an aluminium target mounted on a radial probe in coincidence with cyclotron rf. An assembly comprising a fast scintillator and a liquid light-guide inserted inside the cyclotron was used to detect the {gamma}-rays and to transfer the light signal outside the cyclotron where a matching photo-multiplier tube was used for light to electrical signal conversion. The typical beam intensity for this measurement was a few times 10{sup 11} pps.

43 PARTICLE ACCELERATORS↗

Sterilization of N95 Respirators via Gamma Radiation: Comparison of Post-sterilization Efficacy

This study evaluated gamma irradiation for sterilization and reuse of two models of N95 respirators after gamma radiation sterilization as a method to increase availability of N95 respirators during a shortage. The Sandia National Laboratories Gamma Irradiation Facility was used to irradiate two different models of N95 filtering facepiece respirators at doses ranging from 0 kGy(tissue) to 50 kGy(tissue). The following tests were used to determine the efficacy of the respirator after irradiation sterilization: Ambient Aerosol Condensation Nuclei Counter Quantitative Fit Test, tensile test, strain cycling, oscillatory dynamic mechanical analysis, microscopic image analysis of fiber layers, and electrostatic field measurements. Both of the respirator models exhibited statistically significant changes after gamma irradiation as shown by the Quantitative Fit Test, electrostatic testing and the aerosol testing. The change in electrostatic charge of the filter was correlated with a reduction in capturing particles near the 200 nm size by approximately 40-50%. Both tested respirators showed statistically significant changes associated with gamma sterilization. However, our results indicate that choices in materials and manufacturing methods to achieve N95 filtration lead to different magnitudes of damage when exposed to gamma radiation at sterilization relevant doses. This damage results in lower filtration performance. While our sample size (2 different types of respirators) was small, we did observe a change in electrostatic properties on a filter layer that coincided with the failure on the Quantitative Fit Test and reduction in aerosol filtering efficiency. Key Words: N95 respirators, respirators, airborne transmission, pandemic prevention, COVID-19, gamma sterilization

COVID-19↗

Velocity and void distribution in a counter-current two-phase flow

Different flow regimes were investigated in a horizontal channel. Simulating a hot leg injection in case of a loss of coolant accident or flow conditions in reflux condenser mode, the hydraulic jump and partially reversed flow were identified as major constraints for a high amount of entrained water. Trying to simulate the reflux condenser mode, the test section now includes an inclined section connected to a horizontal channel. The channel is 90 mm high and 110 mm wide. Tests were carried out for water and air at ambient pressure and temperature. High speed video-metry was applied to obtain velocities from flow pattern maps of the rising and falling fluid. In the horizontal part of the channel with partially reversed flow the fluid velocities were measured by planar particle image velocimetry. To obtain reliable results for the gaseous phase, this analysis was extended by endoscope measurements. Additionally, a new method based on the optical refraction at the interface between air and water in a back-light was used to obtain time-averaged void fraction. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗