Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Clock”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Nondestructive Probing of Rabi Oscillations on the Cesium Clock Transition near the Standard Quantum Limit

We report on the nondestructive observation of Rabi oscillations on the Cs clock transition. The internal atomic state evolution of a dipole-trapped ensemble of cold atoms is inferred from the phase shift of a probe laser beam as measured using a Mach-Zehnder interferometer. We describe a single color as well as a two-color probing scheme. Using the latter, measurements of the collective pseudospin projection of atoms in a superposition of the clock states are performed and the observed spin fluctuations are shown to be close to the standard quantum limit.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Absolute Frequency Measurement of the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} Clock Transition

We report on the first absolute transition frequency measurement at the 10{sup -15} level with a single, laser-cooled {sup 40}Ca{sup +} ion in a linear Paul trap. For this measurement, a frequency comb is referenced to the transportable Cs atomic fountain clock of LNE-SYRTE and is used to measure the {sup 40}Ca{sup +} 4s {sup 2}S{sub 1/2}-3d {sup 2}D{sub 5/2} electric-quadrupole transition frequency. After the correction of systematic shifts, the clock transition frequency {nu}{sub Ca{sup +}}=411 042 129 776 393.2(1.0) Hz is obtained, which corresponds to a fractional uncertainty within a factor of 3 of the Cs standard. In addition, we determine the Landeg factor of the 3d{sup 2}D{sub 5/2} level to be g{sub 5/2}=1.200 334 0(3)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Magic Wavelength to Make Optical Lattice Clocks Insensitive to Atomic Motion

In a standing wave of light, a difference in spatial distributions of multipolar atom-field interactions may introduce atomic-motion dependent clock uncertainties in optical lattice clocks. We show that the magic wavelength can be defined so as to eliminate the spatial mismatch in electric dipole, magnetic dipole, and electric quadrupole interactions for specific combinations of standing waves by allowing a spatially constant light shift arising from the latter two interactions. Experimental prospects of such lattices used with a blue magic wavelength are discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

p-Wave Cold Collisions in an Optical Lattice Clock

We study ultracold collisions in fermionic ytterbium by precisely measuring the energy shifts they impart on the atoms' internal clock states. Exploiting Fermi statistics, we uncover p-wave collisions, in both weakly and strongly interacting regimes. With the higher density afforded by two-dimensional lattice confinement, we demonstrate that strong interactions can lead to a novel suppression of this collision shift. In addition to reducing the systematic errors of lattice clocks, this work has application to quantum information and quantum simulation with alkaline-earth atoms.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Large Momentum Transfer Clock Atom Interferometry on the 689 nm Intercombination Line of Strontium

We report the first realization of large momentum transfer (LMT) clock atom interferometry. Using single-photon interactions on the strontium $^1S_{0^–}^3P_1$ transition, we demonstrate Mach-Zehnder interferometers with state-of-the-art momentum separation of up to 141 $\textit{ℏk}$ and gradiometers of up to 81 $\textit{ℏk}$. Furthermore, we circumvent excited state decay limitations and extend the gradiometer duration to 50 times the excited state lifetime. Because of the broad velocity acceptance of the interferometry pulses, all experiments are performed with laser-cooled atoms at a temperature of 3 μK. This work has applications in high-precision inertial sensing and paves the way for LMT-enhanced clock atom interferometry on even narrower transitions, a key ingredient in proposals for gravitational wave detection and dark matter searches.

74 ATOMIC AND MOLECULAR PHYSICS↗

Hamiltonian engineering of spin-orbit–coupled fermions in a Wannier-Stark optical lattice clock

Engineering a Hamiltonian system with tunable interactions provides opportunities to optimize performance for quantum sensing and explore emerging phenomena of many-body systems. An optical lattice clock based on partially delocalized Wannier-Stark states in a gravity-tilted shallow lattice supports superior quantum coherence and adjustable interactions via spin-orbit coupling, thus presenting a powerful spin model realization. The relative strength of the on-site and off-site interactions can be tuned to achieve a zero density shift at a “magic” lattice depth. This mechanism, together with a large number of atoms, enables the demonstration of the most stable atomic clock while minimizing a key systematic uncertainty related to atomic density. Interactions can also be maximized by driving off-site Wannier-Stark transitions, realizing a ferromagnetic to paramagnetic dynamical phase transition.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Observation of millihertz-level cooperative Lamb shifts in an optical atomic clock

Collective couplings of atomic dipoles to a shared electromagnetic environment produce a wide range of many-body phenomena. We report on the direct observation of resonant electric dipole-dipole interactions in a cubic array of atoms in the many-excitation limit. The interactions produce spatially dependent cooperative Lamb shifts when spectroscopically interrogating the millihertz-wide optical clock transition in strontium-87. We show that the ensemble-averaged shifts can be suppressed below the level of evaluated systematic uncertainties for optical atomic clocks. Additionally, we demonstrate that excitation of the atomic dipoles near a Bragg angle can enhance these effects by nearly an order of magnitude compared with nonresonant geometries. Our work demonstrates a platform for precise studies of the quantum many-body physics of spins with long-range interactions mediated by propagating photons.

Science & Technology - Other Topics↗

Quantum nonlocal modulation cancelation with distributed clocks

We demonstrate nonlocal modulation of entangled photons with truly distributed radio frequency (RF) clocks. Leveraging a custom radio-over-fiber (RFoF) system characterized via classical spectral interference, we validate its effectiveness for quantum networking by multiplexing the RFoF clock with one photon from a frequency-bin-entangled pair and distributing the coexisting quantum-classical signals over fiber. Phase modulation of the two photons reveals nonlocal correlations in excellent agreement with theory: in-phase modulation produces additional sidebands in the joint spectral intensity, while out-of-phase modulation is nonlocally canceled. Our simple, feedback-free design attains subpicosecond synchronization—namely, drift less than ~0.5 ps in a 5.5 km fiber over 30 min (fractionally only ~2×10 -8 of the total fiber delay)—and should facilitate frequency-encoded quantum networking protocols such as high-dimensional quantum key distribution and entanglement swapping, unlocking frequency-bin qubits for practical quantum communications in deployed metropolitan-scale networks.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Shift Register Clock Rate Effects on Coincidence Collection 50MHz versus 4MHz Comparison Tests

The following report identifies and quantifies the timing differences between the older slower Shift Register Coincidence/Multiplicity modules and today’s modern higher speed devices. Modern high speed Shift Register Coincidence/Multiplicity instruments employ high speed internal clocks that run at frequencies more than ten times the older units, typically 50MHz. These higher speed clocks allow for a finer time resolution when recording input pulses.

Nuclear Disarmament, Safeguards, & Physical Protec↗

Proton Improvement Plan II (PIP-II) Clock and Timing

The PIP-II timing system is planned to be a two-part system consisting of a global timing system (referred to as ACLK) that provides high level, event-based timing for the whole Fermilab accelerator complex while the second part is a RF synchronized clock system unique to the PIP-II Linac itself (referred to as LCLK). The ACLK System will make use of an external 10 MHz GPS based signal source as a reference for its 650 MHz phase lock as it is the reference frequency for the TCLK output of the system (needed to support legacy hardware around complex). The LCLK System will use a PIP-II Linac RF reference (162.5 MHz) from the Linac LLRF system to allow beam synchronized event placement. Both the ACLK and LCLK systems will have a clock output with a data frame of 16 event bits + 32 data bits with frames broadcast at 650 MHz, phase locked to the 10MHz reference in the case of ACLK and the PIP-II LLRF sourced 162.5 MHz reference in the case of LCLK.

43 PARTICLE ACCELERATORS↗

Characterization of Soft Error Rate Against Memory Elements Spacing and Clock Skew in a Logic with Triple Modular Redundancy in a 65nm Process

Single Event Effects introduce soft errors in ASICs. Design methodologies like Triple ModularRedundancy (TMR) with clock skew insertion, a system level redundancy technique is a commonpractice by designers to mitigate soft errors. However, the optimal spacing between memoryelements in a TMR in 65nm process hasn't been addressed so far. RD53SEU is a mini ASICdevelopment under the framework of the CERN RD53 collaboration to characterize the soft errorrates against the separation spacing and clock skew between memory elements in a TMR. Thisarticle describes the architecture and design aspects of the various test structures on the RD53SEUtest chip.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

An Artificial Intelligence-Assisted Method for Dementia Detection Using Images from the Clock Drawing Test

Background: Widespread dementia detection could increase clinical trial candidates and enable appropriate interventions. Since the Clock Drawing Test (CDT) can be potentially used for diagnosing dementia-related disorders, it can be leveraged to develop a computer-aided screening tool. Objective: To evaluate if a machine learning model that uses images from the CDT can predict mild cognitive impairment or dementia. Methods: Images of an analog clock drawn by 3,263 cognitively intact and 160 impaired subjects were collected during in-person dementia evaluations by the Framingham Heart Study. We processed the CDT images, participant’s age, and education level using a deep learning algorithm to predict dementia status. Results: When only the CDT images were used, the deep learning model predicted dementia status with an area under the receiver operating characteristic curve (AUC) of 81.3% ± 4.3%. A composite logistic regression model using age, level of education, and the predictions from the CDT-only model, yielded an average AUC and average F1 score of 91.9% ±1.1% and 94.6% ±0.4%, respectively. Conclusion: Our modeling framework establishes a proof-of-principle that deep learning can be applied on images derived from the CDT to predict dementia status. When fully validated, this approach can offer a cost-effective and easily deployable mechanism for detecting cognitive impairment.

Neurosciences & Neurology↗

Comparison of various clocks at LANL LAPP facility

Several 40+ hour data records obtained in Oct 2010 from the Los Alamos Portable Pulser Facility (LAPP) Operational clocks show variations of {approx} 27 nsec. Several 16+ hour data records obtained in Aug 2010 from non-operational clocks like those used operationally from 2005 to the present show variations of {approx} 35 nsec. SLRE variability is xxx +/- yyy sec (std dev). SLRE occasionally show unusual events such as those discussed by Pongratz. We will continue to study and monitor.

47 OTHER INSTRUMENTATION↗

Clocked combustor can array

The present application provides a clocked combustor can array for coherence reduction in a gas turbine engine. The clocked combustor can array may include a number of combustor cans positioned in a circumferential array. A first set of the combustor cans may have a first orientation and a second set of the combustor cans may have a second orientation.

33 ADVANCED PROPULSION SYSTEMS↗

Conflux – An Asynchronous 2-to-1 Multiplexor for Time-Division Multiplexing and Clock-less, Token-less Readout

This paper describes an independent, self-arbitrating asynchronous two-to-one multiplexor called Conflux. Conflux can be used to implement clock-less and token-less Time-Division Multiplexing between two sources. This capability can then be used to create a clock-less and token-less aggregate data bus which can be used as a complete asynchronous readout architecture for a chip, a part of a chip or an entire multi-chip system. Conflux utilizes a classic, four-phased asynchronous handshake on both of its input ports as well as on its output port. Asynchronous Request is bundled with Data to ensure consistent propagation delay. The Request is also differential to account for propagation delay differences between Logical Ones and Zeros. Arbitration between the two Conflux input streams is accomplished by three Set-Reset latches. Finally, Conflux cells were used successfully to implement the readout architecture of the FCP130 prototype chip. Tests indicate single Conflux stage delays of 1.8ns and a bandwidth of approximately 20 Gbps in 130nm CMOS.

43 PARTICLE ACCELERATORS↗

Manipulating the circadian clock to increase gene expression

A method of increasing gene expression by manipulating the circadian clock is described that includes transforming a photosynthetic organism to include an expression control sequence that modulates the expression of a clock gene to increase expression of a target gene. Photosynthetic organism having a modified circadian cycle reflecting this method are also described.

Johnson, Charles Hirschie↗

Synchronized electric meter having an atomic clock

Smart electric meters configured to perform fast, time-synchronized electrical energy measurements at the consumer-level are disclosed herein. In some embodiments, a smart electric meter includes circuitry configured to measure an electrical value at a location of an end user in a power system. The smart electric meter can further include an atomic clock configured to output a timing signal, and a controller configured to receive (a) the measured electrical value from the circuitry and (b) the timing signal from the atomic clock. The controller can further (a) process the electrical value to generate meter data and (b) generate a time tag based on the timing signal. Then, the controller can associate the time tag with the meter data to generate time-tagged meter data.

Min, Liang↗

Microstructure for ferroelastic transitions from strain pseudo-spin clock models in two and three dimensions: a mean field analysis

We obtain the microstructure of ferroelastic transitions in two and three dimensions from the solution of their corresponding discrete pseudo-spin models. In two dimensions we consider two transitions each from the high symmetry square and triangle symmetries: square-to-rectangle (SR), square-to-oblique (SO), triangle-to-centered rectangle (TR) and triangle-to-oblique (TO). In three dimensions we study the corresponding spin model for the cubic to tetragonal transition. The Landau free energies for these transitions result in N+ I states clock models (Z{sub N}) with long range interactions and we derive mean-field self-consistency equations for the clock model Hamiltonians. The microstructures from the mean-field solutions of the models are very similar to those obtained from the original continuum models or Monte Carlo simulations on the spin models (in the SR case), illustrating that these discrete models capture the salient physics. The models, in the presence of disorder, provide the basis for the study of the strain glass phase observed in martensitic alloys.

36 MATERIALS SCIENCE↗