Case study: Lockheed-Georgia Company integrated design process

A case study of the development of an Integrated Design Process is presented. The approach taken in preparing for the development of an integrated design process includes some of the IPAD approaches such as developing a Design Process Model, cataloging Technical Program Elements (TPE's), and examining data characteristics and interfaces between contiguous TPE's. The implementation plan is based on an incremental development of capabilities over a period of time with each step directed toward, and consistent with, the final architecture of a total integrated system. Because of time schedules and different computer hardware, this system will not be the same as the final IPAD release; however, many IPAD concepts will no doubt prove applicable as the best approach. Full advantage will be taken of the IPAD development experience. A scenario that could be typical for many companies, even outside the aerospace industry, in developing an integrated design process for an IPAD-type environment is represented.

Waldrop, C. T.↗

Exploration case studies

NASA's Office of Exploration has undertaken four case studies for prospective expansion of manned space activities beyond earth orbit. The subjects of these studies are (1) an expedition to the Martian moon Phobos; (2) a three-mission expedition to Mars; (3) the construction of a man-tended lunar observatory; and (4) the construction of a lunar outpost to serve as the basis for construction of a Martian outpost. The fourth alternative would follow the recommendation of the National Commission on Space for the creation of a 'bridge between worlds' in which explorers would develop ways in which to 'live off the land' in a space environment.

Underwood, Jimmy M.↗

Case Study: The Tower Companies' Commercial Office Solar PV

This case study describes how the Tower Companies selected and successfully executed onsite solar photovoltaic installations at its commercial office properties and highlights the resulting increase in asset value.

solar, solar PV, photovoltaic, onsite solar, comme↗

Case Study: Hybridizing Nuclear Energy Systems in the U.S.

This case study was presented at the ICTP-IAEA VIRTUAL Course on Nuclear-Renewable Integrated Energy Systems: Phenomenology, Research and Development. It provides preliminary results on an analysis of hybridizing the two nuclear power plants owned by Xcel Energy and located in Minnesota. The analysis extends previous analyses that provided only price-taker results. Those assume adjusting the generation sold to the grid does not impact locational marginal electricity prices nor do they estimate impacts on the total net cost to serve the load. This presentation summarizes the new technique that was developed to both optimize the size and operations of the hybridized system and the resulting impacts on the grid when it is operated optimally.

ENERGY PLANNING, POLICY, AND ECONOMY↗

Case Study: Healthcare Realty's Medical Office Solar PV

This case study describes how Healthcare Realty partnered with a renewable energy advisor to establish its solar program and make progress towards its energy and GHG emissions reduction goals; all of the projects in the pipeline will be financed through third-party ownership, via power purchase agreements or through a feed-in-tariff program.

solar, solar PV, photovoltaic, onsite solar, healt↗

DOE Zero Energy Ready Home Case Study HIA 2021: Insight Homes, The Brenner, Felton, DE

Case study of a DOE 2021 Housing Innovation Award winning custom home in a mixed-humid climate that got a HERS 51 without PV, with 1,940 square feet, MERV 13 filters and low-emission paints, adhesives, and carpeting; plus a sealed, conditioned crawl space, and a high-efficiency gas furnace and heat pump.

Building America, residential construction, home b↗

Model Checking Failed Conjectures in Theorem Proving: A Case Study

Interactive mechanical theorem proving can provide high assurance of correct design, but it can also be a slow iterative process. Much time is spent determining why a proof of a conjecture is not forthcoming. In some cases, the conjecture is false and in others, the attempted proof is insufficient. In this case study, we use the SAL family of model checkers to generate a concrete counterexample to an unproven conjecture specified in the mechanical theorem prover, PVS. The focus of our case study is the ROBUS Interactive Consistency Protocol. We combine the use of a mechanical theorem prover and a model checker to expose a subtle flaw in the protocol that occurs under a particular scenario of faults and processor states. Uncovering the flaw allows us to mend the protocol and complete its general verification in PVS.

Pike, Lee↗

NASA Computational Case Study: Spectral Energy Distribution Fitting

The need for faster, more efficient algorithms is an important aspect of scientific computing. Generally, scientists are only exposed to computational issues that arise in their field. Thus, collaboration between a numerical analyst and a scientist is becoming necessary for scientific computing. The purpose of this case study is to expose computer scientists to processes that an astronomer would use to obtain useful results from raw data. For example, astronomers are interested in determining the properties of galaxies and measuring changes in those properties as a function of time throughout cosmic history. To do so, they use certain models that are designed and refined over time via observations at different wavelengths of the light spectrum. The process of matching these models with observed data from studying celestial bodies is referred to as Spectral Energy Distribution (SED) fitting. In this case study, we learn how to perform the SED fit. This process requires knowledge of both the astronomical and computational issues involved when fitting flux, the total energy from a source as seen from Earth, to a set of physical templates. Once a fit is complete, one can classify the source and estimate a number of physical parameters. The goal is to demonstrate how the computer science skill set can be used in the scientific community and to possibly improve one or more of the computational aspects of this problem. The following provides some background on the astronomy issues, including information on the spectral energy distribution and related physical parameters, and the computational issues, including the fitting procedure..

modeling↗

Characterization factors and other air quality impact metrics: Case study for PM 2.5 -emitting area sources from biofuel feedstock supply

In this paper, we develop a framework and metrics for estimating the impact of emission sources on regulatory compliance and human health for applications in air quality planning and life cycle impact assessment (LCIA). Our framework is based on a pollutant's characterization factor (CF) and three new metrics: Available Regulatory Capacity for Incremental Emissions (ARCIE), Source CF Ratio, and Activity Health Impact (AHI) Ratio. ARCIE can be used to assess whether a receptor location has capacity to accommodate additional source emissions while complying with regulatory limits. We present CF as a midpoint indicator of health impacts per unit mass of emitted pollutant. Source CF Ratio enables comparison of potential new-source locations based on human health impacts. The AHI Ratio estimates the health impacts of a pollutant in relation to the utilization of the source for each unit of product or service. These metrics can be applied to any pollutant, energy source sector (e.g., agriculture, electricity), source type (point, line, area), and spatial modeling domain (nation, state, city, region). We demonstrate these metrics through a case study of fine particulate (PM 2.5 ) emissions from U.S. corn stover harvesting and local processing at various scales, representing steps in the biofuel production process. We model PM 2.5 formation in the atmosphere using a novel reduced-complexity chemical transport model called the Intervention Model for Air Pollution (InMAP). Through this case study, we present the first area-source PM 2.5 CFs that address the recommendations of several LCIA studies to establish spatially explicit CFs specific to an energy source sector or type. Overall, the framework developed in this work provides multiple new ways to consider the potential impacts of air emissions through spatially differentiated metrics.

09 BIOMASS FUELS↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Technical assistance for law-enforcement communications: Case study report two

Two case histories are presented. In one study the feasibility of consolidating dispatch center operations for small agencies is considered. System load measurements were taken and queueing analysis applied to determine numbers of personnel required for each separate agency and for a consolidated dispatch center. Functional requirements were developed and a cost model was designed to compare relative costs of various alternatives including continuation of the present system, consolidation of a manual system, and consolidated computer-aided dispatching. The second case history deals with the consideration of a multi-regional, intrastate radio frequency for improved interregional communications. Sample standards and specifications for radio equipment are provided.

Reilly, N. B.↗

A Case Study Investigating the Low Summertime CAPE Behavior in the Global Forecast System

Convective available potential energy (CAPE) is an important index for storm forecasting. Recent versions (v15.2 and v16) of the Global Forecast System (GFS) predict lower values of CAPE during summertime in the continental United States than analysis and observation. We conducted an evaluation of the GFS in simulating summertime CAPE using an example from the Unified Forecast System Case Study collection to investigate the factors that lead to the low CAPE bias in GFS. Specifically, we investigated the surface energy budget, soil properties, and near-surface and upper-level meteorological fields. Results show that the GFS simulates smaller surface latent heat flux and larger surface sensible heat flux than the observations. This can be attributed to the slightly drier-than-observed soil moisture in the GFS that comes from an offline global land data assimilation system. The lower simulated CAPE in GFS v16 is related to the early drop of surface net radiation with excessive boundary layer cloud after midday when compared with GFS v15.2. A moisture-budget analysis indicates that errors in the large-scale advection of water vapor does not contribute to the dry bias in the GFS at low levels. Common Community Physics Package single-column model (SCM) experiments suggest that with realistic initial vertical profiles, SCM simulations generate a larger CAPE than runs with GFS IC. SCM runs with an active LSM tend to produce smaller CAPE than that with prescribed surface fluxes. Note that the findings are only applicable to this case study. Including more warm-season cases would enhance the generalizability of our findings.

54 ENVIRONMENTAL SCIENCES↗