Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CT Scanning”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Oil in Alaska North Slope Gas Hydrate Reservoir: Micro-CT and Flow Simulation Insights into Permeability

Gas hydrate-bearing sands on the Alaska North Slope (ANS) host minor volumes of crude oil whose impact on formation permeability has never been quantified relative to a gas hydrate reservoir system. Here, we combine in situ pressure-core microcomputed-tomography (μ-CT), thermogravimetric analysis (TGA), gas-chromatography–mass-spectrometry (GC–MS), scanning-electron microscopy coupled with energy-dispersive spectroscopy (SEM-EDS), and Stokes-flow simulation to (i) quantify oil saturation, (ii) infer its source, and (iii) evaluate its influence on permeability after gas-hydrate dissociation. μ-CT and SEM-EDS imaging identify the host sediment as silty, with some grain-coating clay present. Eight representative 3003-voxel subvolumes extracted from a preserved pressure core (Core 15P-3c, from the B1 sand (unit B), HYDRATE 02 Geo Data Well (GDW), 886.96–887.29 m measured depth, MD) exhibit porosities of 0.34–0.37 and an average oil saturation of 0.09 ± 0.03, in comparison to an independent TGA-based estimate of 0.16. GC-MS fingerprints obtained from an adjacent depressurized core (Core 17P-1, 891.37–891.44 m MD), together with oil pore habit revealed by μ-CT, suggest that the oil is partly native but also includes contributions from mineral oil-based drilling fluid contamination. Further analysis of oil–porewater interactions and flushing tests confirms that native oil saturation in the analyzed samples ranges from 0.04 to 0.08 with an average of approximately 0.06, and the oil is highly immobile. Flow simulations demonstrate that the native oil saturation of ≈0.06 reduces permeability by approximately 50% due to both pore blockage and increased flow-path tortuosity. These findings reveal the potential presence of native oil within the ANS gas hydrate reservoir and suggest that future simulation models may need to account for its impact on permeability to improve long-term performance predictions of gas and water production.

02 PETROLEUM↗

Computed Tomography Scanning and Geophysical Measurements of the Patterson #5-25 Well in Western Kansas

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize core from the Patterson Field site. This core came from a vertical well (Patterson #5-25 well) that was obtained as part of the U.S. Department of Energy (DOE) sponsored Integrated Midcontinental Stacked Carbon Storage Hub. The primary impetus of this work is a collaboration between NETL and the Kansas Geological Survey to characterize core from the Patterson Field site. The 625 ft of whole core from the Atoka Formation to Precambrian Basement was characterized at NETL. As part of this effort, bulk scans of core were obtained. This report, and the associated scans, provide detailed datasets not typically made publicly available for carbon capture utilization and storage analysis. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/patterson-5-25-well. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the shale pore space, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with x-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL are useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provided a multi-scale analysis of this core and provided both a macro and micro description of the core that is relevant for many subsurface energy related examinations that have traditionally been performed at NETL.

58 GEOSCIENCES↗

Modeling inter‐reader variability in clinical target volume delineation for soft tissue sarcomas using diffusion model

Abstract Background Accurate delineation of the clinical target volume (CTV) is essential in the radiotherapy treatment of soft tissue sarcomas. However, this process is subject to inter‐reader variability due to the need for clinical assessment of risk and extent of potential microscopic spread. This can lead to inconsistencies in treatment planning, potentially impacting treatment outcomes. Most existing automatic CTV delineation methods do not account for this variability and can only generate a single CTV for each case. Purpose This study aims to develop a deep learning‐based technique to generate multiple CTV contours for each case, simulating the inter‐reader variability in the clinical practice. Methods We employed a publicly available dataset consisting of fluorodeoxyglucose positron emission tomography (FDG‐PET), x‐ray computed tomography (CT), and pre‐contrast T1‐weighted magnetic resonance imaging (MRI) scans from 51 patients with soft tissue sarcoma, along with an independent validation set containing five additional patients. An experienced reader drew a contour of the gross tumor volume (GTV) for each patient based on multi‐modality images. Subsequently, two additional readers, together with the first one, were responsible for contouring three CTVs in total based on the GTV. We developed a diffusion model‐based deep learning method that is capable of generating arbitrary number of different and plausible CTVs to mimic the inter‐reader variability in CTV delineation. The proposed model incorporates a separate encoder to extract features from the GTV masks, leveraging the critical role of GTV information in accurate CTV delineation. Results The proposed diffusion model demonstrated superior performance with the highest Dice Index (0.902 compared to values below 0.881 for state‐of‐the‐art models) and the best generalized energy distance (GED) (0.209 compared to values exceeding 0.221 for state‐of‐the‐art models). It also achieved the second‐highest recall and precision metrics among the compared ambiguous image segmentation models. Results from both datasets exhibited consistent trends, reinforcing the reliability of our findings. Additionally, ablation studies exploring different model structures and input configurations highlighted the significance of incorporating prior GTV information for accurate CTV delineation. Conclusions The proposed diffusion model successfully generates multiple plausible CTV contours for soft tissue sarcomas, effectively capturing inter‐reader variability in CTV delineation.

Dong, Yafei [Yale Biomedical Imaging Institute Yal↗

Computed Tomography Scanning and Geophysical Measurements of the One Earth Energy Well #1 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize the Lower Mt. Simon Sandstone and Eau Claire Formation core from the One Earth Energy Well #1 (OEE Well #1) in the Illinois Basin. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE), the Illinois State Geological Survey (ISGS), the University of Illinois, and One Earth Energy to characterize and make publicly available core information of interest to carbon sequestration efforts in the Illinois Basin. This stratigraphic well and the core data produced in this report will aid in understanding the carbon sequestration potential of the Lower Mt. Simon Sandstone and the sealing capacity of the overlying units. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/illinois-storage-corridor-one-earth-energy-1-core.

47 OTHER INSTRUMENTATION↗

Comparison of three measurement modalities for 3D characterization of manufactured features and process-induced porosity in titanium alloy additively manufactured parts

Nondestructive characterization of internal features and defects within complex components is vital for many industrial applications, particularly with the advent of additive manufacturing (AM) technologies. However, community understanding of the limitations of nondestructive methods such as X-ray Computed Tomography (CT) can be limited in certain industrial sectors as these may be emergent applications. In this paper, we investigate the limits of X-ray CT measurements and compare extracted data with mechanical polishing serial sectioning (MPSS) and confocal laser scanning microscopy (CLSM). The test object is an additively manufactured titanium alloy disk that contains both process-induced porosity and machined features, including focused ion beam milled features designed to probe the resolution limits of X-ray CT. Results show that each of these characterization techniques has advantages and disadvantages. We compare data acquisition times, spatial resolution, geometric measurement accuracy and defect visualization fidelity across these modalities to establish a practical framework.

Additive manufacturing↗

Computed Tomography Scanning and Geophysical Measurements of the Smackover Formation from the Roberson 18-19 Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) site in Morgantown, West Virginia, were used to characterize the Upper Jurassic (Oxfordian) Smackover limestone in the Roberson 18-19 1-15H core retrieved from the Atlanta Field, Columbia County, Arkansas. The 365.68-ft long Roberson core came from a vertical well at depths 8,802 ft to 9,169.60 ft, drilled by Southwestern Energy targeting the Smackover Formation as a potential unconventional oil reservoir. The primary impetus of this work was to non-destructively characterize core from the Smackover Formation that was acquired through a core exchange with Southwestern Energy. The Smackover Formation is an unconventional limestone play in southern Arkansas. This report and the associated scans provide detailed datasets not typically made publicly available from unconventional limestone for analysis. The resultant datasets are presented in this report and can be accessed from NETL’s Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/roberson-smackover.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Enhanced Geothermal Systems (EGS) Collab SURF Core

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from 8 wells from the Enhanced Geothermal Systems (EGS) Collab project located in the Sanford Underground Research Facility’s (SURF) 4850 level. The work in this report falls in Experiment 1 in a three-phase experiment, with the primary purpose to increase understanding of hydraulic fracturing. The primary impetus of this work is a collaboration between U.S. Department of Energy (DOE) and the EGS Collab. The resultant datasets are presented in this report and can be accessed from NETL's Energy Data eXchange (EDX) online system using the following link: https://edx.netl.doe.gov/dataset/surf-collab-core. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. None of the equipment used was suitable for direct visualization of the pore space in the core, although fractures and discontinuities were detectable with the methods tested. Low resolution CT imagery with the NETL medical CT scanner was performed on the entire core. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), P-wave, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for more detailed analysis as well as fractured zones. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core; the resulting macro and micro descriptions are relevant to many subsurface energy related examinations traditionally performed at NETL.

47 OTHER INSTRUMENTATION↗

Computed Tomography Scanning and Geophysical Measurements of State 16-2 Well in the Paradox Basin

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize Paradox Basin core from Grand County, Utah. The primary impetus of this work is a collaboration between the U.S. Department of Energy (DOE), the Utah Geological Survey, the University of Utah, and Zephyr Energy to characterize and make publicly available core information from the Cane Creek interval of the Paradox Basin. This stratigraphic well and the core data produced in this report will aid in understanding the structural complexities of the Cane Creek interval and its production potential.

58 GEOSCIENCES↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

Characterization of build parameters and microstructure in low heat input WAAM of Ni-based superalloy Haynes 282

Conference paper for 2024 10th International Conference on Advances in Materials, Manufacturing & Repair for Power Plants. Ni-based superalloy Haynes 282 is a prime candidate for advanced power generation systems due to its superior fabricability, weldability, and high-temperature performance. Additive manufacturing offers potential cost and time savings for gas turbine components. Wire-arc direct energy deposition can create large components but often requires post-processing treatments, such as hot isostatic pressing (HIP), to address porosity. This study explores a low heat-input, high deposition rate GMAW process to achieve fully dense Haynes 282 without HIP. Twenty-one blocks were deposited, varying travel and wire feed speeds. Initial analysis (visual inspection, microstructural examination, and CT) revealed the impact of build parameters on internal porosity and defects. Scanning electron microscopy provided insights into structural heterogeneity and microstructural properties. Related journal article can be found at https://doi.org/10.31399/asm.cp.am-epri-2024p0001.

Adam, Benjamin↗

Computed Tomography Scanning and Geophysical Measurements of the Fayetteville Shale Formation from the Nixon B #1-7 Well

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia were used to characterize core from the Fayetteville and Pitkin formations. This core came from a vertical well drilled by Southwestern Energy (Nixon B #1-7 well) and characterized as part of the U.S. Department of Energy’s (DOE) Fossil Energy and Carbon Management Onshore portfolio’s focus on unconventional shale plays. The primary impetus of this work is to characterize Fayetteville Shale core, from an unconventional shale play in Northwestern Arkansas, that is relatively under-reported on when compared to larger unconventional resources in the continental U.S.

58 GEOSCIENCES↗

Computed Tomography Scanning and Geophysical Measurements of the Integrated Mid-Continent Stacked Carbon Storage Hub Sleepy Hollow Reagan Unit 86A Well

The Computed Tomography (CT) facilities, the Multi-Sensor Core Logger (MSCL), and the Geologic Storage Core Flow laboratory at the National Energy Technology Laboratory (NETL) in Morgantown, West Virginia and Pittsburgh, Pennsylvania were used to characterize a core through Upper Pennsylvanian strata (limestones, mudstones, and sandstones) from the Sleepy Hollow Reagan Unit (SHRU) 86A well in southwest-central Nebraska. The Integrated Mid-Continent Stack Carbon Storage Hub (IMSCS-HUB) core from the vertical well was obtained as part of the Department of Energy’s (DOE) effort to assess the feasibility of stacked storage complexes in Nebraska and Kansas to support a commercial-scale CO2 storage hub. The Sleepy Hollow Field (SHF) is one of three sites within the IMSCS-HUB corridor. Bulk scans of core were obtained from the IMSCS-HUB SHRU 86A well. This report, and the associated scans, include detailed datasets not typically made available to the public. The data sets presented in this report can be accessed from NETL's Energy Data eXchange (EDX) online system.

58 GEOSCIENCES↗

Cross-Modal Guidance for Fast Diffusion-Based Computed Tomography

Diffusion models have emerged as powerful priors for solving inverse problems in computed tomography (CT). In certain applications, such as neutron CT, it can be expensive to collect large amounts of measurements even for a single scan leading to sparse data sets from which it is challenging to obtain high quality reconstructions even with diffusion models. One strategy to mitigate this challenge is to leverage a complementary, easily available imaging modality; however, such approaches typically require retraining the diffusion model with large datasets. In this work, we propose incorporating an additional modality without retraining the diffusion prior, enabling accelerated imaging of costly modalities. We further examine the impact of imperfect side modalities on cross-modal guidance. Our method is evaluated on sparse-view neutron computed tomography, where reconstruction quality is substantially improved by incorporating X-ray computed tomography of the same samples.

Efimov, Timofey [ORNL] (ORCID:000900090098471X)↗

Sparse measurement medical CT reconstruction using multi-fused block matching denoising priors

A major challenge for medical X-ray CT imaging is reducing the number of X-ray projections to lower radiation dosage and reduce scan times without compromising image quality. However these under-determined inverse imaging problems rely on the formulation of an expressive prior model to constrain the solution space while remaining computationally tractable. Traditional analytical reconstruction methods like Filtered Back Projection (FBP) often fail with sparse measurements, producing artifacts due to their reliance on the Shannon-Nyquist Sampling Theorem. Consensus Equilibrium, which is a generalization of Plug and Play, is a recent advancement in Model-Based Iterative Reconstruction (MBIR), has facilitated the use of multiple denoisers are prior models in an optimization free framework to capture complex, non-linear prior information. However, 3D prior modelling in a Plug and Play approach for volumetric image reconstruction requires long processing time due to high computing requirement. Instead of directly using a 3D prior, this work proposes a BM3D Multi Slice Fusion (BM3D-MSF) prior that uses multiple 2D image denoisers fused to act as a fully 3D prior model in Plug and Play reconstruction approach. Our approach does not require training and are thus able to circumvent ethical issues related with patient training data and are readily deployable in varying noise and measurement sparsity levels. In addition, reconstruction with the BM3D-MSF prior achieves similar reconstruction image quality as fully 3D image priors, but with significantly reduced computational complexity. We test our method on clinical CT data and demonstrate that our approach improves reconstructed image quality.

Hossain, Maliha [ORNL]↗

Physics‐based iterative reconstruction for dual‐source and flying focal spot computed tomography

Purpose For single‐source helical Computed Tomography (CT), both Filtered‐Back Projection (FBP) and statistical iterative reconstruction have been investigated. However, for dual‐source CT with flying focal spot (DS‐FFS CT), a statistical iterative reconstruction that accurately models the scanner geometry and acquisition physics remains unknown to researchers. Therefore, our purpose is to present a novel physics‐based iterative reconstruction method for DS‐FFS CT and assess its image quality. Methods Our algorithm uses precise physics models to reconstruct from the native cone‐beam geometry and interleaved dual‐source helical trajectory of a DS‐FFS CT. To do so, we construct a noise physics model to represent data acquisition noise and a prior image model to represent image noise and texture. In addition, we design forward system models to compute the locations of deflected focal spots, the dimension, and sensitivity of voxels and detector units, as well as the length of intersection between x‐rays and voxels. The forward system models further represent the coordinated movement between the dual sources by computing their x‐ray coverage gaps and overlaps at an arbitrary helical pitch. With the above models, we reconstruct images by an advanced Consensus Equilibrium (CE) numerical method to compute the maximum a posteriori estimate to a joint optimization problem that simultaneously fits all models. Results We compared our reconstruction with Siemens ADMIRE, which is the clinical standard hybrid iterative reconstruction (IR) method for DS‐FFS CT, in terms of spatial resolution, noise profile, and image artifacts through both phantoms and clinical scan datasets. Experiments show that our reconstruction has a higher spatial resolution, with a Task‐Based Modulation Transfer Function (MTF task ) consistently higher than the clinical standard hybrid IR. In addition, our reconstruction shows a reduced magnitude of image undersampling artifacts than the clinical standard. Conclusions By modeling a precise geometry and avoiding data rebinning or interpolation, our physics‐based reconstruction achieves a higher spatial resolution and fewer image artifacts with smaller magnitude than the clinical standard hybrid IR.

Wang, Xiao↗

Distributed Optimization for Nonrigid Nano-Tomography

Resolution level and reconstruction quality in nano-computed tomography (nano-CT) are in part limited by the stability of microscopes, because the magnitude of mechanical vibrations during scanning becomes comparable to the imaging resolution, and the ability of the samples to resist radiation induced deformations during data acquisition. In such cases, there is no incentive in recovering the sample state at different time steps like in time-resolved reconstruction methods, but instead the goal is to retrieve a single reconstruction at the highest possible spatial resolution and without any imaging artifacts. Here we propose a distributed optimization solver for tomographic imaging of samples at the nanoscale. Our approach solves the tomography problem jointly with projection data alignment, nonrigid sample deformation correction, and regularization. Projection data consistency is regulated by dense optical flow estimated by Farneback's algorithm, leading to sharp sample reconstructions with less artifacts. Synthetic data tests show robustness of the method to Poisson and low-frequency background noise. We accelerated the solver on multi-GPU systems and validated the method on three nano-imaging experimental data sets.

97 MATHEMATICS AND COMPUTING↗

Novel PBX formulations containing thermally-expandable microspheres for on-demand control of explosive behavior

In this work, we present the formulation and analysis of inert Plastic-Bonded eXplosive (PBX)-surrogates loaded with thermally expandable microspheres (TEMs). TEMs consist of a thermoplastic acrylonitrile shell (10-50 µm diameter) encapsulating an inert low boiling hydrocarbon. Upon heating, the TEMs expand as the shell softens while the hydrocarbon gasifies, increasing the internal pressure and expanding the particle by as much as 120 vol%. We hypothesize that TEM expansion within a PBX will introduce tunable changes in local density and porosity, and ultimately the shock sensitivity. This paper focuses on microstructural analysis of surrogate PBX-TEM formulations, both before and after thermally- induced TEM expansion. The formulations were analyzed by scanning electron microscopy (SEM), ultra-small angle neutron scattering (USANS), and X-ray Computed Tomography (x-ray CT) under various thermal conditions. Evidence suggests that TEM expansion within a PBX is a viable method to impart microstructural changes that are predicted to have a measurable, on-demand effect on the initiation sensitivity. Future work includes development of PBX-TEM formulations with HMX and shock initiation experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Characterization of Build Parameters and Microstructure in Low Heat Input WAAM of Ni-Based Superalloy Haynes 282

Ni-based superalloy Haynes® 282® is being targeted for various applications in advanced power generation systems for its superior fabricability, weldability, and excellent high temperature creep and corrosion performance. This process optimization study aims to use a low heat-input, high deposition rate, controlled Gas Metal Arc Welding (GMAW) process, Cold Metal Transfer (CMT) by Fronius, attempting to achieve fully dense fabrication and possibly avoid the need for HIP. Twenty-one multilayer blocks (~25x100x40 mm3) were deposited to explore a large set of build parameters variations that focused on varying the travel speed from 14 to 42 inches per minute (ipm) and wire feed speed from 150 to 450 ipm. A strong correlation has been observed between arc energy – controlled primarily by travel and wire feed speed. Initial visual inspection, internal microstructural examination, and computed tomography (CT) have been used to determine the effects of built parameters on evolution of internal porosity and defects. Scanning electron microscopy techniques enabled structural and compositional imaging of heterogeneity and changes in microstructural properties.

additive manufacturing↗