Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COURSE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Students authoring molecular case studies as a partial course-based undergraduate research experience (CURE) for lab instruction

Understanding the relationship between protein structure and function is a core-learning goal in biochemistry. Students often struggle to visualize proteins as three-dimensional objects that interact with other molecules to affect its biochemical consequences. We describe here a partial course-based undergraduate research experiences that has students exploring protein structure and function hands-on while authoring a molecular case study intended for others to use.

59 BASIC BIOLOGICAL SCIENCES↗

Diffusion and perfusion MR parameters to assess preoperative short-course radiotherapy response in locally advanced rectal cancer: a comparative explorative study among Standardized Index of Shape by DCE-MRI, intravoxel incoherent motion- and diffusion kurtosis imaging-derived parameters

Purpose: To assess preoperative short-course radiotherapy (SCR) tumor response in locally advanced rectal cancer (LARC) by means of Standardized Index of Shape (SIS) by dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI), apparent diffusion coefficient (ADC), intravoxel incoherent motion (IVIM) and diffusion kurtosis imaging (DKI) parameters derived from diffusion-weighted MRI (DW-MRI). Materials and methods: Thirty-four patients with LARC who underwent MRI scans before and after SCR followed by delayed surgery, retrospectively, were enrolled. SIS, ADC, IVIM parameters [tissue diffusion (D{sub t}), pseudo-diffusion (D{sub p}), perfusion fraction (f{sub p})] and DKI parameters [mean diffusivity (MD), mean of diffusional kurtosis (MK)] were calculated for each patient. IVIM parameters were estimated using two methods, namely conventional biexponential fitting (CBFM) and variable projection (VARPRO). After surgery, the pathological TNM and tumor regression grade (TRG) were estimated. For each parameter, percentage changes between before and after SCR were evaluated. Furthermore, an artificial neural network was trained for outcome prediction. Nonparametric sample tests and receiver operating characteristic curve (ROC) analysis were performed. Results: Fifteen patients were classified as responders (TRG ≤ 2) and 19 as not responders (TRG > 3). Seven patients had TRG 1 (pathological complete response, pCR). Mean and standard deviation values of pre-treatment CBFM D{sub p} and mean value of VARPRO D{sub p} pre-treatment showed statistically significant differences to predict pCR. (p value at Mann–Whitney test was 0.05, 0.03 and 0.008, respectively.) Exclusively SIS percentage change showed significant differences between responder and non-responder patients after SCR (p value << 0.001) and to assess pCR after SCR (p value << 0.001). The best results to predict pCR were obtained by VARPRO Fp mean value pre-treatment with area under ROC of 0.84, a sensitivity of 96.4%, a specificity of 71.4%, a positive predictive value (PPV) of 92.9%, a negative predictive value (NPV) of 83.3% and an accuracy of 91.2%. The best results to assess after treatment complete pathological response were obtained by SIS with an area under ROC of 0.89, a sensitivity of 85.7%, a specificity of 92.6%, a PPV of 75.0%, a NPV of 96.1% and an accuracy of 91.2%. Moreover, the best results to differentiate after treatment responders vs. non-responders were obtained by SIS with an area under ROC of 0.94, a sensitivity of 93.3%, a specificity of 84.2%, a PPV of 82.4%, a NPV of 94.1% and an accuracy of 88.2%. Promising initial results were obtained using a decision tree tested with all ADC, IVIM and DKI extracted parameter: we reached high accuracy to assess pathological complete response after SCR in LARC (an accuracy of 85.3% to assess pathological complete response after SCR using VARPRO D{sub p} mean value post-treatment, ADC standard deviation value pre-treatment, MD standard deviation value post-treatment). Conclusion: SIS is a hopeful DCE-MRI angiogenic biomarker to assess preoperative treatment response after SCR with delayed surgery. Furthermore, an important prognostic role was obtained by VARPRO F{sub p} mean value pre-treatment and by a decision tree composed by diffusion parameters derived by DWI and DKI to assess pathological complete response.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Review and environmental impact assessment of green technologies for base courses in bituminous pavements

This paper provides a critical review of different approaches applied in the Belgian asphalt sector in order to reduce the environmental impact of bituminous road construction works. The focus is on (1) reusing reclaimed asphalt pavement, (2) reducing the asphalt production temperature, and (3) prolonging the service life of the pavement. Environmental impact assessment of these methods is necessary to be able to compare these approaches and understand better the ability to reduce the environmental impact during the life cycle of the road pavement. Attention should be drawn to the possible shift in environmental impact between various life cycle stages, e.g., raw material production, asphalt production, or waste treatment. Life cycle assessment is necessary to adequately assess the environmental impact of these approaches over the entire service life of the bituminous pavement. The three approaches and their implementation in the road sector in Flanders (region in Belgium) are described and the main findings from life cycle assessment studies on these subjects are discussed. It was found from the review that using reclaimed asphalt pavement in new bituminous mixtures might yield significant environmental gains. The environmental impact of the application of warm mix asphalt technologies, on the other hand, depends on the technique used. - Highlights: • Recycling, lower production temperature and durability of asphalt are investigated. • The use of RAP in new asphalt mixtures yields significant environmental advantages. • It would be beneficial to allow RAP in asphalt mixtures for wearing courses. • The use of particular additives might counteract the environmental gain from WMA. • The service life and the environmental data source influence the LCA results.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Longitudinal Changes in Tumor Perfusion Pattern during the Radiation Therapy Course and its Clinical Impact in Cervical Cancer

Purpose: To study the temporal changes of dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) perfusion patterns during the radiation therapy (RT) course and their influence on local control and survival in cervical cancer. Methods and Materials: DCE-MRI was performed in 98 patients with Stage IB{sub 2}-IVA cervical cancer before RT (pre-RT) and during early RT (20-25 Gy) and mid-RT (45-50 Gy). Signal intensity (SI) from the DCE-MRI time-SI curve was derived for each tumor voxel. The poorly perfused low-DCE tumor subregions were quantified as lower 10th percentiles of SI (SI10). Local control, disease-specific survival, and overall survival were correlated with DCE parameters at pre-RT, early RT, and mid-RT. Median follow-up was 4.9 (range, 0.2-9.0) years. Results: Patients (16/98) with initial pre-RT high DCE (SI10 >=2.1) had 100% 5-year local control, 81% disease-specific survival, and 81% overall survival, compared with only 79%, 61%, and 55%, respectively, in patients with pre-RT low DCE. Conversion from pre-RT low DCE to high DCE in early RT (28/82 patients) was associated with higher local control, disease-specific survival, and overall survival (93%, 74%, and 67%, respectively). In comparison with all other groups, outcome was worst in patients with persistently low DCE from pre-RT throughout the mid-RT phase (66%, 44%, and 43%; p = 0.003, 0.003, and 0.020; respectively). Conclusion: Longitudinal tumor perfusion changes during RT correlate with treatment outcome. Persistently low perfusion in pre-RT, early RT, and mid-RT indicates a high risk of treatment failure, whereas outcome is favorable in patients with initially high perfusion or subsequent improvements of initially low perfusion. These findings likely reflect reoxygenation and may have potential for noninvasive monitoring of intra-treatment radio-responsiveness and for guiding adaptive therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electromagnetic Transponders Indicate Prostate Size Increase Followed by Decrease During the Course of External Beam Radiation Therapy

Purpose: Real-time image guidance enables more accurate radiation therapy by tracking target movement. This study used transponder positions to monitor changes in prostate volume that may be a source of dosimetric and target inaccuracy. Methods and Materials: Twenty-four men with biopsy-proven T1c-T3a prostate cancer each had three electromagnetic transponders implanted transperineally. Their coordinates were recorded by the Calypso system, and the perimeter of the triangle formed by the transponders was used to calculate prostate volumes at sequential time points throughout the course of radiation therapy to a dose of 81 Gy in 1.8-Gy fractions. Results: There was a significant decrease in mean prostate volume of 10.9% from the first to the final day of radiation therapy. The volume loss did not occur monotonically but increased in most patients (75%) during the first several weeks to a median maximum on Day 7. The volume increased by a mean of 6.1% before decreasing by a mean maximum difference of 18.4% to nadir (p < 0.001 for both increase and decrease). Glandular shrinkage was asymmetric, with the apex to right base dimension varying more than twice that of the lateral dimension. For all dimensions, the mean change was <0.5 cm. Conclusion: Real-time transponder positions indicated a volume increase during the initial days of radiation therapy and then significant and asymmetric shrinkage by the final day. Understanding and tracking volume fluctuations of the prostate during radiation therapy can help real-time imaging technology perform to its fullest potential.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Shorter-Course Whole-Brain Radiotherapy for Brain Metastases in Elderly Patients

Purpose: Many patients with brain metastases receive whole-brain radiotherapy (WBRT) alone. Using 10 Multiplication-Sign 3 Gy in 2 weeks is the standard regimen in most centers. Regarding the extraordinarily poor survival prognosis of elderly patients with multiple brain metastases, a shorter WBRT regimen would be preferable. This study compared 10 Multiplication-Sign 3 Gy with 5 Multiplication-Sign 4 Gy in elderly patients ({>=}65 years). Methods and Materials: Data from 455 elderly patients who received WBRT alone for brain metastases were retrospectively analyzed. Survival and local (= intracerebral) control of 293 patients receiving 10 Multiplication-Sign 3 Gy were compared with 162 patients receiving 5 Multiplication-Sign 4 Gy. Eight additional potential prognostic factors were investigated including age, gender, Karnofsky performance score (KPS), primary tumor, number of brain metastases, interval from tumor diagnosis to WBRT, extracerebral metastases, and recursive partitioning analysis (RPA) class. Results: The 6-month overall survival rates were 29% after 5 Multiplication-Sign 4 Gy and 21% after 10 Multiplication-Sign 3 Gy (p = 0.020). The 6-month local control rates were 12% and 10%, respectively (p = 0.32). On multivariate analysis, improved overall survival was associated with KPS {>=} 70 (p < 0.001), only one to three brain metastases (p = 0.029), no extracerebral metastasis (p = 0.012), and lower RPA class (p < 0.001). Improved local control was associated with KPS {>=} 70 (p < 0.001), breast cancer (p = 0.029), and lower RPA class (p < 0.001). Conclusions: Shorter-course WBRT with 5 Multiplication-Sign 4 Gy was not inferior to 10 Multiplication-Sign 3 Gy with respect to overall survival or local control in elderly patients. 5 Multiplication-Sign 4 Gy appears preferable for the majority of these patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Linear Correlation Between Patient Survival and Decreased Percentage of Tumor [{sup 18}F]Fluorodeoxyglucose Uptake for Late-Course Accelerated Hyperfractionated Radiotherapy for Esophageal Cancer

Purpose: The aims of this trial were to study whether a decreased percentage of tumor fluorodeoxyglucose (FDG) uptake (%DeltaSUVmax) correlated with overall survival and local control times for patients with esophageal cancer and which patients would benefit from a late-course accelerated hyperfractionated (LCHF) radiation scheme. Methods and Materials: A total of 50 eligible patients with squamous esophageal cancer received positron-emission tomography examinations three times and were treated with the LCHF radiation scheme, with a dose of 68.4 Gy/41 fractions in 6.5 weeks. A %DeltaSUVmax value was calculated, and patients were stratified as highly radiosensitive (HR), moderately radiosensitive (MR), and low radiosensitivity (LR) according to %DeltaSUVmax values in the conventional fraction (CF) scheme. Then, a linear correlation was calculated between patients' survival time and %DeltaSUVmax. Local control and overall survival rates were compared after stratification. Results: In the MR subgroup, there was no linear correlation between %DeltaSUVmax and the CF and LCHF schemes (correlation coefficient, R < 0.4; p > 0.05). In the other subgroups (HR and LR), %DeltaSUVmax values between the CF and LCHF schemes were correlated. Also, in the HR and LR subgroups, %DeltaSUVmax after radiation correlated with overall survival or local control rates (correlation coefficient, R >0.5, and p < 0.05). Three-year local control rates in the HR, MR, and LR subgroups were 100%, 81.5%, and 0%, respectively (p < 0.001). Also, 3-year overall survival rates were 92.4%, 58.8%, and 0% for HR, MR, and LR subgroups, respectively (p < 0.001). Conclusions: Postradiation %DeltaSUVmax was positively correlated with survival time for patients' with esophageal cancer. Patients who benefited from LCHF schedules were those with a decrease of 30% to 60% in tumor FDG uptake after the completion of CF radiation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Quality of Life Outcomes From a Phase 2 Trial of Short-Course Radiation Therapy Followed by FOLFOX Chemotherapy as Preoperative Treatment for Rectal Cancer

Purpose: A prospective phase 2 trial of short-course (SC) radiation therapy (RT) with 25 Gy over 5 fractions, followed by 4 cycles of 5-fluorouracil, oxaliplatin, and leucovorin (mFOLFOX6) before surgery was recently completed at our institution. We present here the patient-reported quality of life (QOL) outcomes from this trial. Methods and Materials: Eighty patients with cT3/T4, any N, any M rectal adenocarcinoma planned for resection were enrolled between 2009 and 2012. The QOL data were obtained prospectively using the Functional Assessment of Cancer Therapy-Colon (FACT-C) questionnaire before RT, before surgery, and 1 year after surgery. The previously validated minimally importance difference (MID) method was used to measure clinically significant QOL changes in FACT-C scores for each patient across time points. We examined the role of ostomy on QOL. We also compared QOL with disease outcomes and physician-reported toxicity. Results: The FACT-C questionnaire was completed by 97% of patients before RT, 85% immediately before surgery, and 62% 1 year after surgery. There was no statistically significant change in mean FACT-C scores from before treatment to after treatment. The majority of patients had either no change or an increase in QOL 1 year after treatment using the MID method. There were significant changes in QOL between patients with ostomy versus no ostomy 1 year after treatment for functional well-being (FWB) (14.81 vs 20.52, P=.018) and the colorectal cancer subscale (CCS) using the MID method (P=.004). Patients without ostomy reported stable changes in bowel control 1 year after surgery. There was no statistically significant correlation between QOL and disease recurrence, pathologic complete response, pathologic T stage downstaging, or acute/late toxicity. Conclusions: SC-RT and sequential mFOLFOX6 as preoperative therapy for rectal cancer results in stable patient-reported QOL outcomes 1 year after treatment. These findings in conjunction with previously reported oncologic outcomes support further evaluation of this regimen in a phase 3 setting.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Nonmeasurable Speckled Contrast-Enhancing Lesions Appearing During Course of Disease Are Associated With IDH Mutation in High-Grade Astrocytoma Patients

Because treatment options at progression are limited for patients with glioma, accuracy in definition of progression is pivotal. Clinically asymptomatic, newly detected, nonmeasurable, speckled contrast-enhancing lesions (SCEs) without immediate relation to prior immune therapy or radiation therapy appear relatively frequently during the course of disease in patients with glioma and challenge the definition of progression based on Response Assessment in Neuro-oncology criteria. Therefore, data characterizing these SCEs are needed for recommendations of subsequent clinical management.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dark Field Microscopy for Analytical Laboratory Courses

An innovative and inexpensive optical microscopy experiment for a quantitative analysis or an instrumental analysis chemistry course is described. The students have hands-on experience with a dark field microscope and investigate the wavelength dependence of localized surface plasmon resonance in gold and silver nanoparticles. Students also observe and measure individual crystal growth during a replacement reaction between copper and silver nitrate. The experiment allows for quantitative, qualitative, and image data analyses for undergraduate students.

36 MATERIALS SCIENCE↗

Probing the course of cosmic expansion with a combination of observational data

We study the cosmic expansion history by reconstructing the deceleration parameter q(z) from the SDSS-II type Ia supernova sample (SNIa) with two different light curve fits (MLCS2k2 and SALT-II), the baryon acoustic oscillation (BAO) distance ratio, the cosmic microwave background (CMB) shift parameter, and the lookback time-redshift (LT) from the age of old passive galaxies. Three parametrization forms for the equation of state of dark energy (CPL, JBP, and UIS) are considered. Our results show that, for the CPL and the UIS forms, MLCS2k2 SDSS-II SNIa+BAO+CMB and MLCS2k2 SDSS-II SNIa+BAO+CMB+LT favor a currently slowing-down cosmic acceleration, but this does not occur for all other cases, where an increasing cosmic acceleration is still favored. Thus, the reconstructed evolutionary behaviors of dark energy and the course of the cosmic acceleration are highly dependent both on the light curve fitting method for the SNIa and the parametrization form for the equation of state of dark energy.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-J-62: Estimating Plausible Treatment Course Dose Distributions by Accounting for Registration Uncertainty and Organ Motion

Purpose: Dose accumulation following deformable image registration (DIR) is challenging. In this study, we used a statistical sampling approach, which takes into account both DIR uncertainties and patient-specific organ motion, to study the distribution of possible true dose distributions. Methods: The study included ten patients (six CT scans/patient) treated with radiotherapy for prostate cancer. For each patient, the planned dose was re-calculated on the repeated geometries, following rigid registration based on fiducial markers. The dose re-calculated on the first CT served as our snapshot dose distribution (D1) and the average of the first five repeat scans as our treatment course reference dose distribution (Dref). Patient-specific motion and DIR-uncertainties, at each voxel in CT1, were assessed using a previously developed DIR performance measure, the distance discordance metric (DDM). To sample the distribution of possible true, predicted dose distributions (Dpred), we resampled D1 by perturbing the location of each voxel with the corresponding DDM. The three dose distribution approaches are compared for the rectum and the bladder. Results: The bladder generalized equivalent uniform dose (gEUD) from the averaged Dpred was closer to the gEUDref than to the gEUD1 (difference: 0.6 vs. 1.0 Gy). For both structures, the gEUDpred was higher than the gEUDref, and significantly higher (p≤0.05) for the rectum (average: 50.8 Gy vs. 48.0 Gy). Conclusion: We have shown that the bladder gEUD values resulting from our DIR-uncertainty inclusive dose sampling approach, Dpred, were closer to the gEUD from Dref than the gEUD values from D1. For the rectum, gEUDpred overestimated gEUDref. Theoretically however, gEUDpred values, sampled from DDM uncertainties are more representative of dose uncertainties.

60 APPLIED LIFE SCIENCES↗

SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

60 APPLIED LIFE SCIENCES↗

MO-DE-201-03: This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine

Fundamental knowledge of radiologic anatomy and physiology is critical for medical physicists. Many physicists are exposed to this topic only in graduate school, and knowledge is seldom formally evaluated or assessed after Part I of the ABR exam. Successful interactions with clinicians, including surgeons, radiologists, and oncologists requires that the medical physicist possess this knowledge. This course presents a review of radiologic anatomy and physiology as it applies to projection radiography, fluoroscopy, CT, MRI, U/S, and nuclear medicine. We will review structural anatomy, manipulation of tissue contrast, the marriage between anatomy and physiology, and explore how medical imaging exploits normal and pathological processes in the body to generate contrast. Learning Objectives: Review radiologic anatomy. Examine techniques to manipulate tissue contrast in radiology. Integrate anatomy and physiology in molecular imaging.

60 APPLIED LIFE SCIENCES↗

SU-F-J-81: Evaluation of Automated Deformable Registration Between Planning Computed Tomography (CT) and Daily Cone Beam CT Images Over the Course of Prostate Cancer Radiotherapy

Purpose: To compute daily dose delivered during radiotherapy, deformable registration needs to be relatively fast, automated, and accurate. The aim of this study was to evaluate the performance of commercial deformable registration software for deforming between two modalities: planning computed tomography (pCT) images acquired for treatment planning and cone beam (CB) CT images acquired prior to each fraction of prostate cancer radiotherapy. Methods: A workflow was designed using MIM Software™ that aligned and deformed pCT into daily CBCT images in two steps: (1) rigid shifts applied after daily CBCT imaging to align patient anatomy to the pCT and (2) normalized intensity-based deformable registration to account for interfractional anatomical variations. The physician-approved CTV and organ and risk (OAR) contours were deformed from the pCT to daily CBCT over the course of treatment. The same structures were delineated on each daily CBCT by a radiation oncologist. Dice similarity coefficient (DSC) mean and standard deviations were calculated to quantify the deformable registration quality for prostate, bladder, rectum and femoral heads. Results: To date, contour comparisons have been analyzed for 31 daily fractions of 2 of 10 of the cohort. Interim analysis shows that right and left femoral head contours demonstrate the highest agreement (DSC: 0.96±0.02) with physician contours. Additionally, deformed bladder (DSC: 0.81±0.09) and prostate (DSC: 0.80±0.07) have good agreement with physician-defined daily contours. Rectum contours have the highest variations (DSC: 0.66±0.10) between the deformed and physician-defined contours on daily CBCT imaging. Conclusion: For structures with relatively high contrast boundaries on CBCT, the MIM automated deformable registration provided accurate representations of the daily contours during treatment delivery. These findings will permit subsequent investigations to automate daily dose computation from CBCT. However, improved methods need to be investigated to improve deformable results for rectum contours.

60 APPLIED LIFE SCIENCES↗

Some Thermodynamic Features of Uranium–Plutonium Nitride Fuel in the Course of Burnup

Calculation studies on the effect of carbon and oxygen impurities on the chemical and phase compositions of nitride uranium–plutonium fuel in the course of burnup are performed using the IVTANTHERMO code. It is shown that the number of moles of UN decreases with increasing burnup level, whereas UN{sub 1.466}, UN{sub 1.54}, and UN{sub 1.73} exhibit a considerable increase. The presence of oxygen and carbon impurities causes an increase in the content of the UN{sub 1.466}, UN{sub 1.54} and UN{sub 1.73} phases in the initial fuel by several orders of magnitude, in particular, at a relatively low temperature. At the same time, the presence of impurities abruptly reduces the content of free uranium in unburned fuel. Plutonium in the considered system is contained in form of Pu, PuC, PuC{sub 2}, Pu{sub 2}C{sub 3}, and PuN. Plutonium carbides, as well as uranium carbides, are formed in small amounts. Most of the plutonium remains in the form of nitride PuN, whereas unbound Pu is present only in the areas with a low burnup level and high temperatures.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗