Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION PRODUCTS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Atomic scale simulations for improved CRUD and fuel performance modeling

A more mechanistic description of fuel performance codes can be achieved by deriving models and parameters from atomistic scale simulations rather than fitting models empirically to experimental data. The same argument applies to modeling deposition of corrosion products on fuel rods (CRUD). Here are some results from publications in 2016 carried out using the CASL allocation at LANL.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Investigating Uranium Corrosion in Magnesium-containing Sludge Using X-ray Tomography - 20042

One of the current primary concerns within the British nuclear community is the decommissioning of legacy storage ponds in Sellafield Cumbria, where nuclear fuel cladding material (a Mg-Al alloy) resides along with fuel metallic swarf. Corrosion of the immersed metallic elements, which has been occurring over the storage period, has resulted in the formation of what is commonly known as Corroded Magnox Sludge. The behaviour of uranium metal within this particular environment and, more significantly, the identity of the corrosion products that may have formed is currently unknown. The present study attempts to shed some light on these aspects by investigating simplified surrogate systems, mimicking storage ponds. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface Structure and Corrosion Behavior of Mg{sub 68−x}Zn{sub 28+x}Ca{sub 4}(x = 0.4) Bulk Metallic Glasses after Immersion in Ringer’s Solution

The main aim of the present study was to determine the impact of Zn on the surface structure and corrosion behavior of Mg-based metallic glasses after immersion in Ringer’s solution. The corrosion rate expressed by the volume of released hydrogen in the form of a function of immersion time in Ringer’s solution at 37 °C was presented. The surface structure and corrosion products, which were formed during the immersion tests, were examined by means of scanning electron microscopy and the following spectroscopic methods: x-ray photoelectron spectroscopy, x-ray diffractometry, secondary ion mass spectrometry and energy-dispersive x-ray spectroscopy. As a result of the investigations of the surface structure, oxides (MgO, CaO, ZnO), hydroxides (Mg(OH){sub 2}, Ca(OH){sub 2}) and carbonates (CaCO{sub 3}) were identified. The analysis of the research results allowed the determination of a probable course and corrosion mechanism of the above-mentioned metallic glasses during immersion in Ringer’s solution.

36 MATERIALS SCIENCE↗

Examining Mechanisms of Groundwater Hg(II) Treatment by Reactive Materials: An EXAFS Study

Laboratory batch experiments were conducted to examine mechanisms of Hg(II) removal by reactive materials proposed for groundwater treatment. These materials included granular iron filings (GIF), 1:1 (w/w) mixtures of metallurgical granular Fe powder + elemental S (MGI+S) and elemental Cu + elemental S (Cu+S), granular activated carbon (GAC), attapulgite clay (ATP), ATP treated with 2-amino-5-thiol-1,3,4-thiadiazole (ATP-a), and ATP treated with 2,5-dimercapto-1,3,4-thiadiazole (ATP-d). Following treatment of simulated groundwater containing 4 mg L{sup -1} Hg for 8 or 16 days, the solution pH values ranged from 6.8 to 8.8 and Eh values ranged from +400 to -400 mV. Large decreases in aqueous Hg concentrations were observed for ATP-d (>99%), GIF (95%), MGI+S (94%), and Cu+S (90%). Treatment of Hg was less effective using ATP (29%), ATP-a (69%), and GAC (78%). Extended X-ray absorption fine structure (EXAFS) spectra of Hg on GIF, MGI+S, and GAC indicated the presence of an Hg-O bond at 2.04-2.07 {angstrom}, suggesting that Hg was bound to GIF corrosion products or to oxygen complexes associated with water sorbed to activated carbon. In contrast, bond lengths ranging from 2.35 to 2.48 {angstrom} were observed for Hg in Cu+S, ATP-a, and ATP-d treatments, suggesting the formation of Hg-S bonds.

54 ENVIRONMENTAL SCIENCES↗

IDENTIFYING IMPURITIES IN SURPLUS NON PIT PLUTONIUM FEEDS FOR MOX OR ALTERNATIVE DISPOSITION

This report provides a technical basis for estimating the level of corrosion products in materials stored in DOE-STD-3013 containers based on extrapolating available chemical sample results. The primary focus is to estimate the levels of nickel, iron, and chromium impurities in plutonium-bearing materials identified for disposition in the United States Mixed Oxide fuel process.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Nanoscale Chemical Imaging of Zinc Oxide Nanowire Corrosion

Nanoscale chemical images of individual bare and alumina-coated zinc oxide nanowires (NWs) were recorded using tip-enhanced second harmonic generation (SHG) spectroscopy before and after exposure to carbon dioxide and water vapor. The NWs were exposed for 0, 2, 4 and 6 days, and images were collected for the same bare nanowire after each two-day exposure period. Corrosion of the bare ZnO NW to zinc carbonate was evident from far-field and near-field SHG images and simultaneously recorded AFM data. The expected zinc carbonate corrosion product is SHG inactive. The AFM profile of the NW showed vertical and lateral expansion in different regions of the nanowire. The lower resolution far-field SHG signal decreased gradually and uniformly. The near-field SHG signal provided a profile of the evolving NW under investigation with a spatial resolution of ~100 nm which is in agreement with the AFM results. In contrast, alumina-coated ZnO NWs that were exposed in the same gas environment showed reduced, but still observable, degradation. The 3-nm thick alumina protective layer may have been insufficient to fully protect the NW, or the coating may have been incomplete. Thicker coatings preclude the tip-enhanced method. Nevertheless, the ability to monitor corrosion on a nanometer scale is a powerful tool for a fundamental understanding of surface chemical processes and should lead to the discovery of protective layers to prevent or delay degradation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Combining Raman Microprobe and XPS to Study High Temperature Oxidation of Metals

Raman microprobe spectroscopy was applied in studies of high-temperature air oxidation of a ferritic alloy (HT-9) in the absence and presence of zirconia coatings with the objective of evaluating the technique as a way to quickly screen candidate cladding materials and actinide-based mixed oxide fuel mixtures for advanced nuclear reactors. When oxidation was relatively uniform, Raman spectra collected using microscope optics with low spatial resolution were found to be similar to those collected with conventional Raman spectroscopy. These spectra could be used to identify major oxide corrosion products and follow changes in the composition of the oxides due to heating. However, when the oxidation films were comprised of multiple layers of varying composition, or with layers containing metallic phases, techniques with higher depth resolution and sensitivity to zero-valence metals were necessary. The requirements were met by combining Raman microprobe using different optical configurations and x-ray photoelectron spectroscopy.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

241-AY-102 Leak detection pit drain line visual inspection - 15678

In October 2012, Washington River Protection Solutions LLC (WRPS) determined that waste had leaked into the annulus of Tank 241-AY-102. WRPS conducted an extensive review of Tank AY-102 and increased both inspection and monitoring of the tank; however, the precise cause and location of the leak could not be determined. In parallel with the leak in the primary tank, the Tank AY-102 leak detection pit (LDP) was accumulating water through the drain system external to the secondary tank liner. Liquid collecting in the LDP is suspected to be from water intrusion and collects at a rate such that the LDP must be pumped routinely. Following a routine pumping event on June 20, 2013, elevated radiation dose rates were noted on the transfer hose and surface contamination readings were found on the transfer pump when it was removed from the Tank AY-102 LDP. These two field readings suggested that tank waste from a secondary liner breach could be leaking into the LDP. As a result, WRPS initiated a plan to ascertain the integrity of the secondary tank liner including a robotic inspection of the LDP. To perform the robotic visual inspection, a custom robotic crawler with a deployment device was designed, built, and operated by IHI Southwest for WRPS to inspect the 6 in (152 mm) leak detection pit drain line. To ensure success when deployed in the field, the inspection equipment was demonstrated at both the IHI facility in Denver, Colorado, and the Hanford Site using full scale piping mockups. On November 20, 2013 WRPS inspected the 6 in (152 mm) diameter drain line. The deployment device successfully attached to the drain line, and the crawler entered the drain line and traversed to within approximately 7 ft (2.1 m) of the central sump located under the center of the tank before losing traction. Crawler performance was satisfactory, and the quality of the camera image and lighting provided sufficient detail to document the current condition of the visible regions of the pipe. The inspection showed that the majority of the drain line was dry. Two wet areas were observed, a portion of the line nearest the LDP and a portion near the center of the tank. The portion nearest the LDP was under water prior to pumping on November 14, 2013. Although sediment and debris were seen during the inspection, it is believed to be construction debris and corrosion products. No material was found in the inspection that looked like tank waste or the material seen in the Tank AY-102 annulus (i.e., no greenish or yellowish deposits or dark fluids, dried salt deposits, or crystalline material). The contamination levels seen on the crawler were consistent with past values seen on LDP pumping equipment. Sampling and analysis of the recovered residues from the crawlers did not find material consistent with tank waste. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Possibility of High Phosphorus Pig Iron as Sacrificial Anode

Cathodic protection is an effective method to control the corrosion of underground pipelines and submerged structures. In the present work, high phosphorus containing pig iron was utilized as sacrificial anode for cathodic protection of underground mild steel plates and the results were compared with that of a commercially pure magnesium sacrificial anode. Driving potential and current between the galvanically coupled sacrificial anodes and mild steel plates were continuously monitored in real time for one month. Microstructure and morphology of the corrosion products formed on the surface of pig iron, magnesium sacrificial anodes and mild steel plates were observed with the help of optical microscope and scanning electron microscopy, and phase identification were performed using x-ray diffraction, Raman spectroscopy and Fourier transform infrared spectroscopy. The distribution of phosphorus in the pig iron matrix and soluble rust formation on the surface of pig iron under buried condition were critical from the point of sacrificial effect, indicating the possible scientific reasons for high phosphorous pig iron to be used as sacrificial anode.

36 MATERIALS SCIENCE↗

Investigation of historical metal objects using Laser Induced Breakdown Spectroscopy (LIBS) technique

Analysis of metal objects is a necessary step for establishing an appropriate conservation treatment of an object or to follow up the application's result of the suggested treatments. The main considerations on selecting a method that can be used in investigation and analysis of metal objects are based on the diagnostic power, representative sampling, reproducibility, destructive nature/invasiveness of analysis and accessibility to the appropriate instrument. This study aims at evaluating the usefulness of the use of Laser Induced Breakdown Spectroscopy (LIBS) Technique for analysis of historical metal objects. In this study various historical metal objects collected from different museums and excavations in Egypt were investigated using (LIBS) technique. For evaluating usefulness of the suggested analytical protocol of this technique, the same investigated metal objects were investigated by other methods such as Scanning Electron Microscope with energy-dispersive x-ray analyzer (SEM-EDX) and X-ray Diffraction (XRD). This study confirms that Laser Induced Breakdown Spectroscopy (LIBS) Technique is considered very useful technique that can be used safely for investigating historical metal objects. LIBS analysis can quickly provide information on the qualitative and semi-quantitative elemental content of different metal objects and their characterization and classification. It is practically non-destructive technique with the critical advantage of being applicable in situ, thereby avoiding sampling and sample preparations. It is can be dependable, satisfactory and effective method for low cost study of archaeological and historical metals. But we have to take into consideration that the corrosion of metal leads to material alteration and possible loss of certain metals in the form of soluble salts. Certain corrosion products are known to leach out of the object and therefore, their low content does not necessarily reflect the composition of the metal at the time of the object manufacture. Another point should be taken into consideration that the heterogeneity of a metal alloy object that often result from poor mixing of the different metal alloy composition.There is a necessity to carry out further research to investigate and determine the most appropriate and effective approaches and methods for conservation of these metal objects.

36 MATERIALS SCIENCE↗

Enhanced Corrosion of Magnesium as a Treatment for Legacy SNF - 19369

The ability of high concentrations of MgCl{sub 2} to induce activity-controlled dissolution of magnesium has been investigated in the context of providing a means of stabilising reactive metal fuel wastes, as oxide/hydroxide corrosion products, to enhance the resilience of the waste form following disposal. Kinetic parameters were measured using a novel immersion testing method that utilise the gravimetric measurement of evolving hydrogen produced by the oxidation of the metal. This method demonstrates extremely high precision relative to a traditional volumetric approach and appears to be relatively robust in its accuracy despite its sensitivity to changing temperature. An effective activation energy of 10.2 kJmoL{sup -1} was measured for the reaction using the Arrhenius equation over a temperature range of 30-70 deg. C. This implies that the reaction remains controlled by the diffusion of reactants to the metal surface and fails to corroborate the effect previously observed by Casey and Bergeron. This may be explained by differences in initial conditions, or it could be that the system transitions into the previously observed state as it reaches equilibrium, a possibility that was not accounted for in this study as the experiments focussed on measuring the initial rate of reaction. Repeat testing and further study is warranted given that enhanced corrosion could offer a means to produce a self-immobilising waste form with minimal intrusion, offering both improved safety tolerances and cost savings for the decommissioning and waste disposal efforts ongoing at the Sellafield site. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion and interdiffusion studies of U{sub 3}Si{sub 2}

U{sub 3}Si{sub 2} is a candidate fissile phase for use in accident tolerant fuel systems in light-water reactors because of its higher fissile density, higher thermal conductivity when compared to uranium dioxide. It is also expected to have acceptable performance in contact with high temperature water (e.g., a leaker event from breached cladding) and in regards to interaction with different cladding materials. In high temperature water, U{sub 3}Si{sub 2} is expected to form a protective SiO{sub 2} coating. However, the resistance of U{sub 3}Si{sub 2} to corrosion under light water reactor service conditions has been previously unknown. In this study, the corrosion tests of sintered U{sub 3}Si{sub 2} discs were conducted in pressurized water at 300 C. degrees in an autoclave. The exposure times to corrosion were 6 hours and 24 hours. Detailed composition and microstructural analysis were carried out using a combination of techniques including X-ray diffraction (XRD), scanning electron microscopy (SEM), transmission electron microscopy (TEM) equipped with energy dispersive X-ray spectroscopy (EDS). Only slight weight change of U{sub 3}Si{sub 2} discs can be detected in corrosion tests up to 24 hours. A layered structure of corrosion products formed on U{sub 3}Si{sub 2}, with a glassy silicon oxide layer at the top followed by a nanocrystalline UO{sub 2} layer, a Si-rich oxide layer and then a mixture oxide layer of U and Si. A diffusion couple of U{sub 3}Si{sub 2} in contact with Zircaloy-4 has been tested at 800 C. degrees up to 100 hours. The resulting microstructure and interdiffusion have been studied with SEM/EDS. Some limited interdiffusion has been observed in these tests as well as a layer containing Zr and Si forms between the U{sub 3}Si{sub 2} disc and the Zircaloy-4 disc. (authors)

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Retrieval of High Level Waste for the Cigeo Project - A Practical Retrieval Test Story - 16085

Since the passing of the June 28, 2006 Act, Andra has incorporated in its step-wise design development of the French high level waste (HLW) and intermediate level long lived waste (IL-LLW) deep geological repository (DGR, aka Cigeo) various requirements linked to 'reversibility' at different stages of the repository life cycle (from its construction phase to its final closure). Reversibility is based on a number of practical dispositions including the progressivity of the development and deployment of the facility, the flexibility of the nature of operations being carried out, the adaptability of the facility to future modifications and the possible retrieval of waste. The capacity to retrieve waste from Cigeo, also called 'retrievability', bears specific requirements. On a shorter term, one must demonstrate that the waste container retrieval operations are technically safe and feasible over at least 100 years. The current paper starts with two acceptations: retrievability and reversibility. It details how those two notions are defined and inter-linked. The 'Retrievability Scale' as proposed by OECD/NEA (and adopted by Andra) is also reminded. The needs for demonstration of retrieval operations are also exposed for the two categories of waste containers disposed of in Cigeo (IL-LLW and HLW) within the context of their respective emplacement configurations (in disposal horizontal vaults and micro-tunnels) at different stages of the repository life cycle. The technical part of the paper is then focused on a practical case story: a technological test campaign (still running) of HLW container retrieval out of a steel cased disposal micro-tunnel. On a test bench built on surface to simulate (create) the environmental conditions that may prevail inside a HLW micro-tunnel at time of retrieval, it was possible to check whether the mechanical means developed for the purpose were adequate and sufficient. The test case story is exposed, c/w the problems and challenges encountered (high temperature impairing the retrieval robot's proper functioning, presence of corrosion products...). The trouble-shooting solutions implemented and the results are commented. This article concludes with a critical analysis of the methods and equipment used, the results obtained and provides some perspectives of improvement. The positive outcomes of this technical test campaign pave the way for planning the in situ retrieval tests to be programmed in the 'industrial pilot phase' of Cigeo (to be implemented over the ten first years of operations, including the active and inactive test period and the first years of disposal activities): the industrial pilot phase is presently scheduled around 2026-2036 (provided the Cigeo construction is authorized in 2021, following the licensing request filing scheduled in 2018). The issues of IL-LLW containers retrieval (for which specific solutions are also studied and technical demonstrations engaged or planned) are also briefly presented. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Periodic Verification of the Scaling Factor for Radwastes in Korean NPPs - 13294

According to the acceptance criteria for a low and intermediate level radioactive waste (LILW) listed in Notice No. 2012-53 of the Nuclear Safety and Security Commission (NSSC), specific concentrations of radionuclides inside a drum has to be identified and quantified. In 5 years of effort, scaling factors were derived through destructive radiochemical analysis, and the dry active waste, spent resin, concentration bottom, spent filter, and sludge drums generated during 2004 ∼ 2008 were evaluated to identify radionuclide inventories. Eventually, only dry active waste among LILWs generated from Korean NPPs were first shipped to a permanent disposal facility on December 2010. For the LILWs generated after 2009, the radionuclides are being radiochemically quantified because the Notice clarifies that the certifications of the scaling factors should be verified biennially. During the operation of NPP, the radionuclides designated in the Notice are formed by neutron activation of primary coolant, reactor structural materials, corrosion products, and fission products released into primary coolant through defects or failures in fuel cladding. Eventually, since the radionuclides released into primary coolant are transported into the numerous auxiliary and support systems connected to primary system, the LILWs can be contaminated, and the radionuclides can have various concentration distributions. Thus, radioactive wastes, such as spent resin and dry active waste generated at various Korean NPP sites, were sampled at each site, and the activities of the regulated radionuclides present in the sample were determined using radiochemical methods. The scaling factors were driven on the basis of the activity ratios between a or β-emitting nuclides and γ-emitting nuclides. The resulting concentrations were directly compared with the established scaling factors' data using statistical methods. In conclusions, the established scaling factors were verified with a reliability of within 2σ, and the scaling factors will be applied for newly analyzed LILWs to evaluate the radionuclide inventories. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Critical Design Issues of Tokamak Cooling Water System of ITER's Fusion Reactor

U.S. ITER is responsible for the design, engineering, and procurement of the Tokamak Cooling Water System (TCWS). The TCWS transfers heat generated in the Tokamak to cooling water during nominal pulsed operation 850 MW at up to 150 C and 4.2 MPa water pressure. This water contains radionuclides because impurities (e.g., tritium) diffuse from in-vessel components and the vacuum vessel by water baking at 200 240 C at up to 4.4MPa, and corrosion products become activated by neutron bombardment. The system is designated as safety important class (SIC) and will be fabricated to comply with the French Order concerning nuclear pressure equipment (December 2005) and the EU Pressure Equipment Directive using ASME Section VIII, Div 2 design codes. The complexity of the TCWS design and fabrication presents unique challenges. Conceptual design of this one-of-a-kind cooling system has been completed with several issues that need to be resolved to move to next stage of the design. Those issues include flow balancing between over hundreds of branch pipelines in parallel to supply cooling water to blankets, determination of optimum flow velocity while minimizing the potential for cavitation damage, design for freezing protection for cooling water flowing through cryostat (freezing) environment, requirements for high-energy piping design, and electromagnetic impact to piping and components. Although the TCWS consists of standard commercial components such as piping with valves and fittings, heat exchangers, and pumps, complex requirements present interesting design challenges. This paper presents a brief description of TCWS conceptual design and critical design issues that need to be resolved.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

SLUDGE TREATMENT PROJECT ENGINEERED CONTAINER RETRIEVAL AND TRANSFER SYSTEM PRELMINARY DESIGN HAZARD AND OPERABILITY STUDY

This Hazard and Operability (HAZOP) study addresses the Sludge Treatment Project (STP) Engineered Container Retrieval and Transfer System (ECRTS) preliminary design for retrieving sludge from underwater engineered containers located in the 105-K West (KW) Basin, transferring the sludge as a sludge-water slurry (hereafter referred to as 'slurry') to a Sludge Transport and Storage Container (STSC) located in a Modified KW Basin Annex, and preparing the STSC for transport to T Plant using the Sludge Transport System (STS). There are six, underwater engineered containers located in the KW Basin that, at the time of sludge retrieval, will contain an estimated volume of 5.2 m{sup 3} of KW Basin floor and pit sludge, 18.4 m{sup 3} of 105-K East (KE) Basin floor, pit, and canister sludge, and 3.5 m{sup 3} of settler tank sludge. The KE and KW Basin sludge consists of fuel corrosion products (including metallic uranium, and fission and activation products), small fuel fragments, iron and aluminum oxide, sand, dirt, operational debris, and biological debris. The settler tank sludge consists of sludge generated by the washing of KE and KW Basin fuel in the Primary Clean Machine. A detailed description of the origin of sludge and its chemical and physical characteristics can be found in HNF-41051, Preliminary STP Container and Settler Sludge Process System Description and Material Balance. In summary, the ECRTS retrieves sludge from the engineered containers and hydraulically transfers it as a slurry into an STSC positioned within a trailer-mounted STS cask located in a Modified KW Basin Annex. The slurry is allowed to settle within the STSC to concentrate the solids and clarify the supernate. After a prescribed settling period the supernate is decanted. The decanted supernate is filtered through a sand filter and returned to the basin. Subsequent batches of slurry are added to the STSC, settled, and excess supernate removed until the prescribed quantity of sludge is collected. The sand filter is then backwashed into the STSC. The STSC and STS cask are then inerted and transported to T Plant.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Critical review of gamma spectrometry detection approaches for in-plant surface deposition monitoring

Surface deposition of activated corrosion product on oxide layers of light-water reactor primary system components is the primary source for ex-core radiation fields and personnel radiation exposure. Understanding the deposition mechanism and what factors influence the deposition and release behaviors are crucial for developing effective radiation field reduction measures. One of the available tools to assess the surface deposition is in-plant gamma spectrometry, which has been performed for several decades using either sodium iodide (NaI) or high-purity germanium (HPGe) detectors. Lately, the much more mobile cadmium-zinc-telluride (CZT) detectors are increasingly employed by stations because of their ease in use and handling. However, all of these gamma detectors face the same challenges; namely large-geometry samples of inconsistent sample compositions and sometimes gaps in the information necessary to establish proper efficiency calibrations. This paper reviews current measurements and efficiency calibration approaches taken in the industry. The validity of the measurement results and the feasibility of the data's use in understanding source term behavior is examined. Suggestions are made for the development of a more robust deposit characterization and radiation field monitoring program. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Hyperfine interactions and lattice dynamics of Sn{sub 21}O{sub 6}Cl{sub 16}(OH){sub 14}

In this study, the tin(II) oxy-hydroxychloride Sn{sub 21}O{sub 6}Cl{sub 16}(OH){sub 14} has been synthesised and investigated. This compound is the synthetic equivalent of mineral abhurite, which was discovered in 1985 as a tin corrosion product formed on the surface of tin ingots after long immersion in seawater. The Moessbauer parameters of Sn{sub 21}O{sub 6}Cl{sub 16}(OH){sub 14} determined at various temperatures are reported and discussed for the first time. At room temperature, the isomer shift and the quadrupole splitting are, respectively, {delta}=3.22 mm s{sup -1} and {delta}=1.71 mm s{sup -1}, relative to the centroid of the spectrum of BaSnO{sub 3}. The Moessbauer recoil-free fraction has been also evaluated over a wide range of temperature. At 300 K, the recoil-free fraction of Sn{sub 21}O{sub 6}Cl{sub 16}(OH){sub 14} is f{sub 300}=0.09{+-}0.02. - Graphical abstract: In this study, the tin(II) oxy-hydroxychloride Sn{sub 21}O{sub 6}Cl{sub 16}(OH){sub 14} has been synthesised. The Moessbauer parameters determined at various temperatures are reported and discussed for the first time. At room temperature, the isomer shift and the quadrupole splitting of Sn{sub 21}O{sub 6}Cl{sub 16}(OH){sub 14} are, respectively, {delta}=3.22 mm s{sup -1} and {delta}=1.71 mm s{sup -1} and the recoil-free fraction at 300 K is f{sub 300}=0.09{+-}0.02.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗