Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CORROSION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Study of development and utilization of a multipurpose atmospheric corrosion sensor

There has been a critical need for analyzing various aspects of atmospheric corrosion and for the development of atmospheric corrosion microsensors. The project work has involved the following activities: (1) making of multielectrode corrosion monitors on dielectric substrates; (2) testing them in the laboratory for functional characteristics; (3) preparing a report on the state of the art of atmospheric corrosion sensor development around the world; and (4) corrosion testing of electrochemical changes of sensor specimens and related fog testing. The study included work on the subject of development and utilization of a multipurpose atmospheric corrosion sensor and this report is the annual report on work carried out on this research project. This has included studies on the development of sensors of two designs, stage 1 and stage 2, and with glass and alumina substrate, experimentation and development and characterization of the coating uniformity, aspects of corrosion monitoring, literature search on the corrosion sensors and their development. A state of the art report on atmospheric corrosion sensor development was prepared and submitted.

Diwan, Ravinder M.↗

Determination of the Corrosive Conditions Present within Aircraft Lap-Splice Joints

The complexity of airframe structure lends itself to damage resulting from crevice corrosion. Fuselage lap-splice joints are a particularly important structural detail in this regard because of the difficulty associated with detection and measurement of corrosion in these occluded regions. The objective of this work is to develop a laboratory corrosion test protocol to identify the chemistry to which lap joints are exposed and to develop a model of the corrosion within the joints. A protocol for collecting and identifying the chemistry of airframe crevice corrosion has been developed. Capillary electrophoresis (CE) is used to identify the ionic species contained in corrosion product samples removed from fuselage lap splice joints. CE analysis has been performed on over sixty corrosion product samples removed from both civilian and military aircraft. Over twenty different ions have been detected. Measurements of pH of wetted corroded surfaces indicated an alkaline occluded solution. After determining the species present and their relative concentrations, the resultant solution was reproduced in bulk and electrochemical tests were performed to determine the corrosion rate. Electrochemical analyses of the behavior of AA2024-T3 in these solutions gave corrosion rates of up to 250 microns per year (10 mpy). Additional tests have determined the relative importance of each of the detected ions in model solutions used for future predictive tests. The statistically significant ions have been used to create a second generation solution. Laboratory studies have also included exposure tests involving artificial lap joints exposed to various simulated bulk and crevice environments. The extent and morphology of the attack in artificial lap joints has been compared to studies of corroded samples from actual aircraft. Other effects, such as temperature and potential, as well as the impact of the environment on fatigue crack growth have also been studied.

Lewis, Karen S.↗

Controlled-Release Microcapsules for Smart Coatings for Corrosion Applications

Corrosion is a serious problem that has enormous costs and serious safety implications. Localized corrosion, such as pitting, is very dangerous and can cause catastrophic failures. The NASA Corrosion Technology Laboratory at Kennedy Space Center is developing a smart coating based on pH-sensitive microcapsules for corrosion applications. These versatile microcapsules are designed to be incorporated into a smart coating and deliver their core content when corrosion starts. Corrosion indication was the first function incorporated into the microcapsules. Current efforts are focused on incorporating the corrosion inhibition function through the encapsulation of corrosion inhibitors into water core and oil core microcapsules. Scanning electron microscopy (SEM) images of encapsulated corrosion inhibitors are shown.

Source record↗

Microencapsulation Technology for Corrosion Mitigation by Smart Coatings

A multifunctional, smart coating for the autonomous control of corrosion is being developed based on micro-encapsulation technology. Corrosion indicators as well as corrosion inhibitors have been incorporated into microcapsules, blended into several paint systems, and tested for corrosion detection and protection effectiveness. This paper summarizes the development, optimization, and testing of microcapsules specifically designed to be incorporated into a smart coating that will deliver corrosion inhibitors to mitigate corrosion autonomously. Key words: smart coating, corrosion inhibition, microencapsulation, microcapsule, pH sensitive microcapsule, corrosion inhibitor, corrosion protection pain

Buhrow, Jerry↗

Recent Developments on Autonomous Corrosion Protection Through Encapsulation

This paper concerns recent progress in the development of a multifunctional smart coating, based on microencapsulation, for the autonomous detection and control of corrosion. Microencapsulation has been validated and optimized to incorporate desired corrosion control functionalities, such as early corrosion detection and inhibition, through corrosion-initiated release of corrosion indicators and inhibitors, as well as self-healing agent release triggered by mechanical damage. While proof-of-concept results have been previously reported, more recent research and development efforts have concentrated on improving coating compatibility and synthesis procedure scalability, with a targeted goal of obtaining easily dispersible pigment-grade type microencapsulated materials. The recent progress has resulted in the development of pH-sensitive microparticles as a corrosion-triggered delivery system for corrosion indicators and inhibitors. The synthesis and early corrosion indication results obtained with coating formulations that incorporate these microparticles are reported. The early corrosion indicating results were obtained with color changing and with fluorescent indicators.

Autonomous↗

Corrosion on Mars: Effect of the Mars Environment on Spacecraft Materials

This report presents the results of a one-year project, funded by NASA’s Kennedy Space Center Innovation Fund in FY18, to conduct a theoretical study on the effect of the Mars environment on spacecraft materials. Corrosion resistance is one of the most important properties in selecting materials for landed spacecraft and structures that will support surface operations for the human exploration of Mars. Currently, the selection of materials is done by assuming that the corrosion behavior of a material on Mars will be the same as that on Earth. This is understandable since there is no data on the corrosion resistance of materials in the Mars environment. However, given that corrosion is defined as the degradation of a metal that results from its chemical interaction with the environment, it cannot be assumed that corrosion is going to be the same in both environments since they are significantly different. The goal of this research was to develop a systematic approach to understand corrosion of spacecraft materials on Mars by conducting a literature search of available data, relevant to corrosion in the Mars environment. This project was motivated by the suggestion, by a team of researchers, that some of the structural degradation observed on Curiosity's wheels may have been caused by corrosive interactions with the transient liquid brines, reported to be present on Mars, while the most significant damage was attributed to rock scratching. An extensive literature search, on data relevant to corrosion on Mars, confirmed the need to investigate the interaction between materials, used for spacecraft and structures designed to support long-term surface operations on Mars, and the Mars environment. Previous preliminary experiments, designed to look at the interaction between aerospace aluminum alloy (AA7075-T73) and the gases present in the Mars atmosphere, at 20 degC and a pressure of 700 Pa, showed that there is an interaction between the small amount of oxygen present in the Mars gas and the alloy, when there is a scratch that removes the protective aluminum oxide film. Further studies are needed to consider many other important components of the Mars environment that can affect this interaction such as: the presence of brines, the interaction between these brines and materials, the effect of radiation on these interactions, and the possible catalytic effects of the clays present in the Martian regolith. This theoretical study provides strong justification to conduct experimental work to investigate the interaction between spacecraft materials with simulated Martian environments to reduce Mars exploration costs.

Calle, Luz M.↗

Corrosion Resistance of Materials in the Mars Environment

This paper presents the results of a literature search of available data relevant to corrosion resistance of materials in the Mars environment, as a background for future experimental work. Corrosion resistance is one of the most important properties in selecting materials for landed spacecraft and structures that will support surface operations for the human exploration of Mars. Currently, the selection of materials is done by assuming that the corrosion behavior of a material on Mars will be the same as that on Earth. This is understandable since there is no data available on the corrosion resistance of materials in the Mars environment. However, given that corrosion is defined as the degradation of a metal that results from its chemical interaction with the environment, it cannot be assumed that corrosion is going to be the same in both environments, since they are significantly different. This theoretical study was motivated by the suggestion, by a team of researchers, that some of the structural degradation observed on Curiosity's wheels may have been caused by corrosive interactions with the transient liquid brines, reported to be present on Mars, while the most significant damage was attributed to mechanical damage. An extensive literature search, on data relevant to corrosion on Mars, confirmed the need to investigate the interaction between materials, used for spacecraft and structures designed to support long-term surface operations on Mars, and the Mars environment. Experimental studies are needed to investigate the corrosion behavior of materials in relevant components of the Mars environment such as: the Mars atmosphere, the presence of brines, the interaction between these brines and materials, the effect of radiation on these interactions, and the possible catalytic effects of the clays present in the Martian regolith. The findings from this theoretical study provide strong justification to conduct experimental work to investigate the interaction between spacecraft materials with simulated Martian environments to reduce Mars exploration costs.

Calle, Luz M.↗

A closer look at corrosion of steel reinforcement bars in concrete using 3D neutron and X-ray computed tomography

Corrosion of reinforcing bars constitutes the largest threat to the durability of concrete structures. Thus, several studies have investigated the nature of the corrosion products, most using post-mortem analyses. However, corrosion products evolve when in contact with oxygen, hindering result interpretation. This work presents instead a state-of-the-art, non-destructive 3D method for the assessment of corrosion of embedded reinforcements. Multimodal neutron and X-ray tomography was used to observe, non-destructively, the characteristics of the corrosion products in two concrete samples, with the aim of investigating possible benefits of the use of this technique for reinforced concrete structures. One sample was naturally corroded, extracted from an 81-year-old bridge, the other was corroded via the galvanostatic method, resulting in corrosion-induced cracks. Quantitative and qualitative data was acquired, including the iron-to-rust volumetric ratio in macroscopic interfacial voids and the thickness of the corrosion layer at the steel concrete interface. The iron-to-rust volumetric ratio corresponded to large, soluble, corrosion products, forming in environments with low availability of oxygen for both samples.

36 MATERIALS SCIENCE↗

Corrosion behavior in aluminum/galvanized steel resistance spot welds and self-piercing riveting joints in salt spray environment

Here, this paper underlined the corrosion behavior of aluminum alloy/galvanized steel joints fabricated by resistance spot welding (RSW) and self-piercing riveting (SPR) exposed to different salt-spray cycles. It was found that the crevice generated by different joining methods has an important impact on corrosion behavior. Compared with the RSW joint, less corrosion happened on the coupled regions in SPR joints because of the higher local pH value resulted from the smaller crevice. The crevice, however, has less impact on the types of corrosion products. Galvanic corrosion happened in the coupled region for both RSW and SPR joints. The Pourbaix diagram explained the stable corrosion products of Al and Zn—Fe alloy, which are Al 2 O 3 , ZnO, and Fe 3 O 4 . Additional corrosion products observed from the experiment included α-Al(OH) 3 , Ca 4 Al 2 (CO 3 )(OH) 12 (H 2 O) 5 , Zn 5 (OH) 8 Cl 2 (H 2 O), Zn 5 (CO 3 ) 2 (OH) 6 , and Fe 2 (OH) 2 (CO 3 ), which can be understood by considering the metastable corrosion products, Pourbaix diagram, and possible chemical reactions.

36 MATERIALS SCIENCE↗

Pressure-Driven Fiber-Optic Sensor for Online Corrosion Monitoring

For many industrial applications, corrosion is a life-limiting phenomenon and therefore requires careful consideration and rigorous experimental testing before structural materials can be reliably deployed, particularly in harsh chemical environments. The traditional approach to measuring corrosion requires exposing many samples to the intended environment and then extracting them individually at discrete intervals for postexposure characterization. This approach does not provide a high degree of temporal resolution, nor does it provide any real-time information regarding dynamic changes in corrosion rates. Additionally, developing an online corrosion monitor capable of surviving harsh chemical environments could provide valuable information regarding the structural health of components and changing process conditions that could accelerate corrosion. To this end, a corrosion sensor was developed based on a pressure-driven Fabry-Pérot cavity (FPC). This sensor uses a pressure control system to internally pressurize the FPC formed between the sensor’s housing and a metal-embedded singlemode optical fiber. Simultaneous measurement of the change in FPC length using low-coherence interferometry and the applied pressure enables the calculation of the relative changes in the sensor’s diaphragm thickness due to corrosion on its outer surface. Measurements were made in situ while actively corroding the sensor and were validated against surveillance specimens that were corroded simultaneously. The uncertainties in the measured corrosion were analyzed using error propagation of the uncertainties in the measured pressures and displacements and were found to be <1% of the initial diaphragm thickness.

42 ENGINEERING↗

Hanford Double Shell Waste Tank Corrosion Studies (Final Report)

For fiscal year (FY) 2022, the Savannah River National Laboratory (SRNL) focused on two experimental tasks related to Hanford Double Shell Tank (DST) chemistry and integrity. The first task focused on understanding risk of corrosion due to formation of either continuous layers or discrete patches of solids on the tanks' inner sidewalls and bottoms. The tank bottom solids contact corrosion testing focused on studying the effects of forming a dry adherent solids layer on a carbon steel substrate. Long-term exposure tests and electrochemical tests were performed to investigate the effect of drying (i.e., removing water) from the solids phase. The second task focused on corrosion of the exterior of the secondary liner. In previous years, vapor corrosion inhibitors (VCIs) were investigated as a means of mitigating corrosion of the exterior of the secondary liner. During FY22 the utilization of nitrogen was explored as a means of corrosion mitigation. The corrosion test results with nitrogen were compared with the corrosion mitigation performance of the VCIs.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Corrosion Behavior of Hydrophobic Coatings in Aqueous CO2 Environments

Internal corrosion is caused by gas impurities such as CO2, moisture, and H2S, leading to material degradation. To combat this, the National Energy Technology Laboratory (NETL) developed a novel hydrophobic coating to reduce surface hydrophobicity and enhance the corrosion resistance of steel. NETL’s approach uses multi-layer hydrophobic coatings, a novel and promising coating that could potentially revolutionize the industry's approach to internal corrosion mitigation. This work aims to investigate the corrosion performance of the hydrophobic coating and determine the water uptake. Electrochemical corrosion experiments were carried out on bare X65 carbon steel without and with coating in 3.5 wt.% NaCl saturated with CO2 at 20 °C to follow the water uptake as a function of exposure time. Linear polarization resistance (LPR) was used to determine the corrosion rate for carbon steel immersed in a NaCl electrolyte saturated with CO2. Electrochemical impedance spectroscopy (EIS) of uncoated and coated bare carbon steel was investigated. The analyses of impedance models and water uptake behaviors of hydrophobic coatings were studied for 200 hours during the corrosion process. The water uptake was estimated using the Brasher and Kingsbury relation. The results showed that the superhydrophobic coating that was developed used innovative nano-based materials to act as protection layers on the surface of metallic parts against mechanical aggressors, corrosion, and fouling agents.

corrosion behavior↗

Characterization of Encapsulated Corrosion Inhibitors for Environmentally Friendly Smart Coatings

The NASA Kennedy Space Center's Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion indicators, inhibitors and self-healing agents. This allows the incorporation of autonomous corrosion control functionalities, such as corrosion detection and inhibition as well as the self-healing of mechanical damage, into coatings. This paper presents technical details on the characterization of inhibitor-containing particles and their corrosion inhibitive effects using electrochemical and mass loss methods. Three organic environmentally friendly corrosion inhibitors were encapsulated in organic microparticles that are compatible with desired coatings. The release of the inhibitors from the microparticles in basic solution was studied. Fast release, for immediate corrosion protection, as well as long-term release for continued protection, was observed. The inhibition efficacy of the inhibitors, incorporated directly and in microparticles, on carbon steel was evaluated. Polarization curves and mass loss measurements showed that, in the case of 2MBT, its corrosion inhibition effectiveness was greater when it was delivered from microparticles.

Corrosion↗

Release Properties and Electrochemical Characterization of Encapsulated Corrosion Inhibitors for Environmentally Friendly Smart Coatings

The NASA Kennedy Space Center's Corrosion Technology Lab at the Kennedy Space Center in Florida, U.S.A. has been developing multifunctional smart coatings based on the microencapsulation of environmentally friendly corrosion indicators, inhibitors and self-healing agents. This allows for the incorporation of autonomous corrosion control functionalities, such as corrosion detection and inhibition as well as the self-healing of mechanical damage, into coatings. This paper presents technical details on the characterization of inhibitor-containing particles and their corrosion inhibitive effects using electrochemical and mass loss methods. Three organic environmentally friendly corrosion inhibitors were encapsulated in organic microparticles that are compatible with desired coatings. The total inhibitor content and the release of one of the inhibitors from the microparticles in basic solution was measured. Particles with inhibitor contents of up 60 wt% were synthesized. Fast release, for immediate corrosion protection, as well as long-term release for continued protection, was observed. The inhibition efficacy of the inhibitors, both as the pure materials and in microparticles, on carbon steel was evaluated. Polarization curves and mass loss measurements showed that, in the case of 2MBT, its corrosion inhibition effectiveness was greater when it was delivered from microparticles.

Coatings↗

Long-Term Corrosivity at NASA Kennedy Space Center as a Function of Distance and Time from the Atlantic Ocean

Long-term data to record both seasonal and notional bounding values for corrosivity at multiple sites at NASA Kennedy Space Center was needed to make better materials choices for NASA-based ground and spaceflight programs. The data was valuable for two key reasons, 1) to measure corrosion rate and chloride concentration as a function of time and distance from the Atlantic Ocean, and 2) compare the corrosivity at launchpad and site-specific areas to the more accelerated conditions at the KSC Beachside Atmospheric Corrosion Test Site for coating and materials performance prediction. Sites were chosen from 45 meter (150 feet) to 8 kilometers (5 miles) from the Atlantic Ocean and corrosion variables at each site were measured throughout each year from June 2017 to April 2023, except the Beachside site, which includes data from November 2010. The summary includes corrosivity data and coating performance comparisons at select sites, which will be used as the updated NASA corrosivity standard for corrosion control requirements.

NASA↗

Dynamic and static corrosion of chromium-alumina refractory in simulated nuclear waste glass

Monofrax® K-3, a chromium–alumina refractory, is widely used in nuclear waste glass melters due to its high durability. However, aggressive vitrification conditions still lead to corrosion that limits melter lifespan. Here, this study investigates two key corrosion modes, subsurface and melt-line corrosion, under static and dynamic conditions, using a custom setup enabling precise control of melt velocity and temperature. Experimental results, interpreted using diffusion-limited dissolution models, show that (i) subsurface corrosion increases by approximately 10% per mm/s increase in melt velocity, while melt-line corrosion remains virtually unaffected, (ii) corrosion rate dependence on temperature is inversely proportional to melt viscosity, and (iii) glass composition affects both corrosion modes similarly, based on Cr 2 O 3 , Al 2 O 3 , and alkali contents. The experimental data also allowed the determination of diffusion coefficients of major dissolving species, which were found to be consistent between the melt-line and subsurface corrosion models, indicating their suitability for future CFD studies.

12 - MGMT OF RADIOACTIVE AND NON-RADIOACTIVE WASTE↗

Corrosion characteristics of Mo and TZM alloy for plasma facing components in molten lithium at 623 K

Here, in this study, the corrosion behaviours of molybdenum (Mo) and a Mo-based alloy (TZM) were investigated using a static immersion corrosion technique. Weight loss, surface microstructure, and corrosion depth of Mo and the TZM alloy were correlated with elements. The compatibility of Mo and the TZM alloy in static liquid Li was suitable. Mo demonstrated uniform corrosion with a homogenous dissolution of free C and Mo, and TZM alloy exhibited a nonuniform corrosion behaviour with a preferential grain boundary attack caused by the selective dissolution of free C, Ti, and Zr. When the surface oxidation layer of the samples was consumed, free C from Mo and TZM diffused into molten Li to form Li 2 C 2 and then was captured by Zr, Ti, and Mo to form thermodynamically stable carbides, which resulted in the enrichment of the C layer near the sample surfaces. In addition, Ti and Zr acted as N-trappers in liquid Li; the formation of Zr and Ti nitrides resulted in the enrichment of N, Ti, and Zr elements on the surface and led to TZM corrosion increase. Thus, Zr and Ti depletion, pitting, and grain boundary corrosion were problematic for TZM under long-term exposure to liquid Li. Reducing the content of free C and nonmetallic N and increasing the amount of Ti and Zr carbides on the surface of and inside the raw TZM alloy helped improve the corrosion resistance of TZM in liquid Li.

36 MATERIALS SCIENCE↗

Hot corrosion behavior of 304 & P91 graded composite transition joint under molten sulfate salts

A novel graded composite transition joint (GCTJ) between AISI 304 stainless steel and ASTM A335 P91 steel, has been demonstrated remarkablely superior creep performance compared to the conventional dissimilar metal weldment (DMW) under equivalent conditions. However, this advance is challenged by hot corrosion under salt deposition at elevated temperatures. Here, this study investigates the hot corrosion behavior of 304&P91 GCTJ exposed to sulfate salts at 700°C. Compared to the 304 steel, corrosion attacks initiate in the P91 triangle, where the dual-phase microstructure of ferrite and tempered martensite significantly influences pitting initiation. Anodic dissolution mainly occurs within the tempered martensite due to more vulnerable sites within the tempered martensite. With prolonged exposure, corrosion propagates across both phases, and the corrosion depth within the P91 triangle is related to the exposed surface area ratio between 304 and P91. Electrochemical analysis reveals the occurrence of galvanic corrosion between the 304 and P91, with a positive linear relationship between anodic dissolution current density (I a ) and the exposed surface area ratio between 304 and P91 in molten salts, further emphasizing the critical impact of this ratio on the corrosion severity in the P91 triangle. These findings underscore the importance of transition zone design optimization in mitigating localized corrosion.

Galvanic corrosion↗