Graphics Flutter Analysis Methods, an interactive computing system at Lockheed-California Company

An interactive computer graphics system, Graphics Flutter Analysis Methods (GFAM), was developed to complement FAMAS, a matrix-oriented batch computing system, and other computer programs in performing complex numerical calculations using a fully integrated data management system. GFAM has many of the matrix operation capabilities found in FAMAS, but on a smaller scale, and is utilized when the analysis requires a high degree of interaction between the engineer and computer, and schedule constraints exclude the use of batch entry programs. Applications of GFAM to a variety of preliminary design, development design, and project modification programs suggest that interactive flutter analysis using matrix representations is a feasible and cost effective computing tool.

Radovcich, N. A.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 12.0 ampere-hour nickel-cadmium spacecraft cells for the international ultraviolet explorer

An evaluation test program was conducted to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. The 20 cells were manufactured for the National Aeronautics and Space Administration, Goddard Space Flight Center (GSFC). The cells are from a lot of 175 cells procured for the International Ultraviolet Explorer project. Due to a change in requirements, the project selected to use 6.0 ampere-hour cells. Therefore, the remaining cells of this lot have been placed in storage at GSFC for use on a future GSFC project. All the cells are rated at 12.0 ampere-hours and contain double ceramic seals. Test limits specify those values in which a cell is to be terminated from a particular charge or discharge. Requirements are referred to as normally expected values based on past performance of aerospace nickel cadmium cells with demonstrated life characteristics.

Harkness, J. D.↗

Feasibility study of an Integrated Program for Aerospace-vehicle Design (IPAD) system. Volume 6: Implementation schedule, development costs, operational costs, benefit assessment, impact on company organization, spin-off assessment, phase 1, tasks 3 to 8

A baseline implementation plan, including alternative implementation approaches for critical software elements and variants to the plan, was developed. The basic philosophy was aimed at: (1) a progressive release of capability for three major computing systems, (2) an end product that was a working tool, (3) giving participation to industry, government agencies, and universities, and (4) emphasizing the development of critical elements of the IPAD framework software. The results of these tasks indicate an IPAD first release capability 45 months after go-ahead, a five year total implementation schedule, and a total developmental cost of 2027 man-months and 1074 computer hours. Several areas of operational cost increases were identified mainly due to the impact of additional equipment needed and additional computer overhead. The benefits of an IPAD system were related mainly to potential savings in engineering man-hours, reduction of design-cycle calendar time, and indirect upgrading of product quality and performance.

Garrocq, C. A.↗

Thermal performance evaluation of Solar Energy Products Company (SEPCO) 'Soloron' collector tested outdoors

The test article, Model EF-212, Serial Nr. 002, is a single glazed collector with a nonselective absorber plate, using flowing air as the heat transfer medium. The absorber plate and box frame are aluminum and the insulation is one inch isocyanurate foam board with thermal conductivity of 0.11 (BTU/sq ft Hr0/ft.) The tests included the following. (1) time constant test, (2) collector efficiency test, (3) collector stagnation test, (4) incident angle modifier test, (5) load test, (6) weathering test, and (7) absorber plate optical properties test. The results of these tests are tabulated, graphed, or otherwise recorded.

Chiou, J., Sr.↗

Utilization requirements. A southern California Gas Company project SAGE report: Utilization requirements

Utilization requirements are given and comparisons made of two phase III SAGE (solar assisted gas energy) installations in California: (1) a retrofit installation in an existing apartment building in El Toro, and (2) an installation in a new apartment building in Upland. Such testing in the field revealed the requirements to be met if SAGE-type installations are to become commercially practical on a widespread basis in electric and gas energy usage.

Barbieri, R. H.↗

Public policy issues. A Southern California Gas Company project SAGE report

The use of solar energy to stretch our supplies of fossil fuels was investigated. Project SAGE (semi-automated ground environment) addresses itself to one application of this goal, solar assistance in central water heating systems for multifamily projects. Public policy issues that affect the rate of adoption of solar energy systems were investigated and policy actions were offered to accelerate the adoption of SAGE and other solar energy systems.

Barbieri, R. H.↗

Initial evaluation tests of General Electric Company 26.5 ampere-hour nickel-cadmium spacecraft cells with auxiliary electrodes for the TIROS-N and NOAA-A satellites

This evaluation test program had the purpose to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are referenced to as normally expected values based on past performance of aerospace nickel-cadmium cells with demonstrated life characteristics. A requirement does not constitute a limit for discontinuance from test.

Harkness, J. D.↗

Test and evaluation of Fern Engineering Company, Incorporated, solar heating and hot water system

Tests, test results, examination and evaluation by Underwriters Laboratory, Inc., of a single family solar heating and hot water system consisting of collector, storage, control, transport, and data acquisition are presented. The structural characteristics of the solar flat plate collectors were evaluated according to snow and wind loads indicated in various building codes to determine their suitability for use both Michigan and Pennsylvania where prototype systems were installed. The flame spread classification of the thermal insulation is discussed and the fire tests conducted on components are described. The operation and dielectrics withstand tests of the energy transport module indicate the module is capable of rated air delivery. Tests of the control panel indicate the relay coil temperatures exceed the temperature limits allowed for the insulating materials involved.

Source record↗

Parametric study of prospective early commercial MHD power plants (PSPEC). General Electric Company, task 1: Parametric analysis

The performance and cost of moderate technology coal-fired open cycle MHD/steam power plant designs which can be expected to require a shorter development time and have a lower development cost than previously considered mature OCMHD/steam plants were determined. Three base cases were considered: an indirectly-fired high temperature air heater (HTAH) subsystem delivering air at 2700 F, fired by a state of the art atmospheric pressure gasifier, and the HTAH subsystem was deleted and oxygen enrichment was used to obtain requisite MHD combustion temperature. Coal pile to bus bar efficiencies in ease case 1 ranged from 41.4% to 42.9%, and cost of electricity (COE) was highest of the three base cases. For base case 2 the efficiency range was 42.0% to 45.6%, and COE was lowest. For base case 3 the efficiency range was 42.9% to 44.4%, and COE was intermediate. The best parametric cases in bases cases 2 and 3 are recommended for conceptual design. Eventual choice between these approaches is dependent on further evaluation of the tradeoffs among HTAH development risk, O2 plant integration, and further refinements of comparative costs.

Marston, C. H.↗

Evaluation Program for Secondary Spacecraft Cells: Initial Evaluation Tests of General Electric Company 6.0 Ampere Hour Nickel Cadmium Spacecraft Cells for the Dynamic Explorer Satellite Program

Evaluation tests of 10 nickel cadmium cells are described. Although pressures were greater than what normally was exhibited by General Electric cells in the past, it is recommended that these cells be placed on life test simulating the predicted Dynamic Explorer flight profiles.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere-hour nickel-cadmium spacecraft cells for the tracking data relay satellite system

Five cells provided by NASA's Goddard Space Flight Center were evaluated at room temperature and pressure (25 C plus or minus 2 C) with discharges at the 2 hour rate. Measurements of the cell containers following test, indicated an average increase of .006 inches at the plate thickness. Average end of charge voltages and pressures, and capacity output in ampere hours were determined. Three cells exceeded the voltage requirements of 1.52 volts during both c/10 charges at 20 C. All cells exceeded the voltage requirement of 1.52 volts during the 0 C overcharge test, although their end charges were below 1.50 volts. The pressure requirement of 65 psia was exceeded by both pressure transducer cells during c/10 charges at 25 C and 20 C and also during the 0 C overcharge test. The cells with pressure transducers reached a pressure of 20 psia before reaching the voltage limit of 1.550 volts during the pressure versus capacity test, and exhibited a pressure decay of 2 psia during the last 30 minutes of the 1 hour open circuit stand. Average capacity was 51.3 ampere hours.

Harkness, J. D.↗

Solar heating, cooling, and domestic hot water system installed at Kaw Valley State Bank and Trust Company, Topeka, Kansas

The building has approximately 5600 square feet of conditioned space. Solar energy was used for space heating, space cooling, and preheating domestic hot water (DHW). The solar energy system had an array of evacuated tube-type collectors with an area of 1068 square feet. A 50/50 solution of ethylene glycol and water was the transfer medium that delivered solar energy to a tube-in-shell heat exchanger that in turn delivered solar heated water to a 1100 gallon pressurized hot water storage tank. When solar energy was insufficient to satisfy the space heating and/or cooling demand, a natural gas-fired boiler provided auxiliary energy to the fan coil loops and/or the absorption chillers. Extracts from the site files, specification references, drawings, and installation, operation and maintenance instructions are presented.

Source record↗

Initial evaluation tests of General Electric Company 12.0 ampere hour nickel cadmium spacecraft cells with design variables

All evaluation tests were performed at room ambient pressure and temperature, with discharges at a 2 hour rate. Tests consisted of phenolphthalein leak tests, three capacity tests, an auxiliary electrode test, a charge retention test, an internal short test, a charge efficiency test, overcharge tests, and a pressure versus capacity test. Results of the tests and recommendations for improvements in manufacturing are presented.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company, 6.0 ampere-hour nickel-cadmium spacecraft cells for the GOES-D, E and F satellite program

The tests are to insure that all cells put into the life cycle program are of high quality by the screening of cells found to have electrolyte leakage, internal shorts, low capacity, or inability of any cell to recover its open-circuit voltage above 1.150 volts during the internal short test. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are referenced to normally expected values based on past performance of aerospace nickel-cadmium cells with demonstrated life characteristics. Recommendations for the improvement of the manufacturing processes are presented.

Harkness, J. D.↗

Evaluation program for secondary spacecraft cells: Initial evaluation tests of General Electric Company 40.0 ampere hour nickel cadmium spacecraft cells for the tracking data relay satellite system

Average end of charge voltages and pressures, and capacity output in ampere hours are presented. Test limits specify those values at which a cell is to be terminated from charge or discharge. Requirements are based on past cell performance data. The requirement does not constitute a limit for discontinuance from testing. The nickel cadmium batteries were screened for internal shorts, low capacity, electrolyte leakage, or inability of any cell to recover its open circuit voltage above 1.150 volts during the internal short test.

Hall, S. W.↗