Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “COMFORT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Real-Time Omnidirectional Stereo Rendering: Generating 360° Surround-View Panoramic Images for Comfortable Immersive Viewing

Surround-view panoramic images and videos have become a popular form of media for interactive viewing on mobile devices and virtual reality headsets. Viewing such media provides a sense of immersion by allowing users to control their view direction and experience an entire environment. When using a virtual reality headset, the level of immersion can be improved by leveraging stereoscopic capabilities. Stereoscopic images are generated in pairs, one for the left eye and one for the right eye, and result in providing an important depth cue for the human visual system. For computer generated imagery, rendering proper stereo pairs is well known for a fixed view. However, it is much more difficult to create omnidirectional stereo pairs for a surround-view projection that work well when looking in any direction. One major drawback of traditional omnidirectional stereo images is that they suffer from binocular misalignment in the peripheral vision as a user's view direction approaches the zenith / nadir (north / south pole) of the projection sphere. This paper presents a real-time geometry-based approach for omnidirectional stereo rendering that fits into the standard rendering pipeline. Our approach includes tunable parameters that enable pole merging - a reduction in the stereo effect near the poles that can minimize binocular misalignment. Results from a user study indicate that pole merging reduces visual fatigue and discomfort associated with binocular misalignment without inhibiting depth perception.

360° panorama↗

WE-E-18A-06: To Remove Or Not to Remove: Comfort Pads From Beneath Neonates for Radiography

Purpose: To obtain an analytical empirical formula for the photon dose source term in forward direction from bremsstrahlung generated from laser-plasma accelerated electron beams in aluminum solid targets, with electron-plasma temperatures in the 10–100 keV energy range, and to calculate transmission factors for iron, aluminum, methacrylate, lead and concrete and air, materials most commonly found in vacuum chamber labs. Methods: Bremsstrahlung fluence is calculated from the convolution of thin-target bremsstrahlung spectrum for monoenergetic electrons and the relativistic Maxwell-Juettner energy distribution for the electron-plasma. Unattenuatted dose in tissue is calculated by integrating the photon spectrum with the mass-energy absorption coefficient. For the attenuated dose, energy dependent absorption coefficient, build-up factors and finite shielding correction factors were also taken into account. For the source term we use a modified formula from Hayashi et al., and we fitted the proportionality constant from experiments with the aid of the previously calculated transmission factors. Results: The forward dose has a quadratic dependence on electron-plasma temperature: 1 joule of effective laser energy transferred to the electrons at 1 m in vacuum yields 0,72 Sv per MeV squared of electron-plasma temperature. Air strongly filters the softer part of the photon spectrum and reduce the dose to one tenth in the first centimeter. Exponential higher energy tail of maxwellian spectrum contributes mainly to the transmitted dose. Conclusion: A simple formula for forward photon dose from keV range temperature plasma is obtained, similar to those found in kilovoltage x-rays but with higher dose per dissipated electron energy, due to thin target and absence of filtration.

07 ISOTOPE AND RADIATION SOURCES↗

Measure Guideline: Condensing Boilers—Control Strategies for Optimizing Performance and Comfort in Residential Applications

The combination of a gas-fired condensing boiler with baseboard convectors and an indirect water heater has become a common option for high-efficiency residential space heating in cold climates. While there are many condensing boilers available on the market with rated efficiencies in the low to mid 90% efficient range, it is imperative to understand that if the control systems are not properly configured, these heaters will perform no better than their non-condensing counterparts. Based on previous research efforts, it is apparent that these types of systems are typically not designed and installed to achieve maximum efficiency (Arena 2010). It was found that there is a significant lack of information for contractors on how to configure the control systems to optimize overall efficiency. For example, there is little advice on selecting the best settings for the boiler reset curve or how to measure and set flow rates in the system to ensure that the return temperatures are low enough to promote condensing. It has also been observed that recovery from setback can be extremely slow and, at times, not achieved. Recovery can be affected by the outdoor reset control, the differential setting on the boiler and over-sizing of the boiler itself. This guide is intended for designers and installers of hydronic heating systems interested in maximizing the overall system efficiency of condensing boilers when coupled with baseboard convectors. It is applicable to new and retrofit applications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Test Plan to Evaluate the Relationship Among IAQ, Comfort, Moisture, and Ventilation in Humid Climates

This experimental plan describes research being conducted by Pacific Northwest National Laboratory (PNNL), in coordinatation with Florida Solar Energy Center (FSEC), Florida HERO, and Lawrence Berkeley National Laboratory (LBNL) to evaluate the impact of ventilation rate on interior moisture levels, temperature distributions, and indoor air contaminant concentrations. Specifically, the research team will measure concentrations of indoor air contaminants, ventilation system flow rates, energy consumption, and temperature and relative humidity in ten homes in Gainesville, FL to characterize indoor pollutant levels and energy consumption associated with the observed ventilation rates. PNNL and FSEC have collaboratively prepared this experimental test plan, which describes background and context for the proposed study; the experimental design; specific monitoring points, including monitoring equipment, and sampling frequency; key research questions and the associated data analysis approach; experimental logistics, including schedule, milestones, and team member contact information; and clearly identifies the roles and responsibilities of each team in support of project objectives.

High Performance Homes↗

Review of Residential Comfort Control Products and Opportunities

This paper begins by discussing the interaction of each major component in advanced sensor and control applications related to HVAC equipment. The paper also looks at the applications of these components to commissioning, maintenance and operations of the HVAC equipment in residential buildings. A summary of state-of-the-art product features is also provided. These products are categorized through their primary application type (commissioning/maintenance or operation) and the features are categorized by component type (sensors, data storage, human-in-the-loop, communication, and controls). A common theme that emerges from this study is the importance of the ability for various product categories to be connected to each other. There are many manufacturers of sensors and many manufacturers of controls, but the power to automate any commissioning, maintenance or operation application, requires connectivity.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Research and Development of a Ventilation-Integrated Comfort System

From an indoor air quality perspective, the best residential ventilation strategies include filtering outdoor air and distributing that air to all occupied parts of a home. From an energy standpoint, it's desirable that energy be transferred from the exhaust air to the incoming outdoor air to limit heating and cooling impacts. Heat or energy recovery ventilation systems (HRVs or ERVs) can provide these functions, but researchers have seen many poor installations related to design, installation, and operation and maintenance. More robust ventilation systems may involve an ERV with a dedicated duct distribution system and controls. Such a duct system can be costly to install, and many builders reduce these costs by connecting an ERV to a central heating and cooling duct system. While this can sometimes be done effectively, researchers have seen consistent challenges with low, inconsistent, or imbalanced flow rates; high electricity consumption; and - of greatest concern - outdoor air short-circuiting or not being delivered to occupied spaces at all. Most ERVs are designed to operate with their own duct system; they are not designed as an add-on to much larger HVAC systems. With support from the US DOE Building Technologies Office, Steven Winter Associates, Inc. (SWA) partnered with Mitsubishi Electric Trane US, CORE Energy Recovery Solutions, and Therma-Stor LLC to design and test VICS prototypes. A conceptual diagram is shown in Figure 1, and the latest prototype (shown in Figure 2) was manufactured by Therma-Stor and tested in SWA's facility in Norwalk, CT. The ERV heat exchanger was provided by CORE, and the VICS was installed in conjunction with a 1-ton, inverter heat pump provided by Mitsubishi.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Impact of Mass Wood Walls on Building Energy Use, Peak Demand, and Thermal Comfort

Thermal mass moderates indoor temperatures, allowing the heating, ventilation, and air conditioning (HVAC) system to operate more efficiently during peak hours. Cross-Laminated Timber (CLT) and other mass wood products provide thermal mass to the building envelope in a lighter and more environmentally friendly form than concrete. However, the influence of CLTs on heating and cooling energy, peak energy demand, and the indoor climate is not well-known. This project was formed to find the energy efficiency benefits of mass timber structures. The objectives were to (1) test the thermal performance of insulated mass wall structures in controlled laboratory conditions, (2) validate simulation models to expand performance to natural climatic conditions, (3) isolate the impact of the thermal properties of wood (thermal mass, thermal conductivity, moisture storage) on heating and cooling energy use and peak energy demand, and to optimize the performance. Currently, the designs used for CLT buildings have focused on structural and fire issues, and they do not consider the thermal mass benefits. Therefore, the thermal performance is not necessarily optimized.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Optimizing Hydronic Heating for Comfort and Performance in Multifamily Housing

Inefficient control settings in multifamily boilers often lead to substantial energy and cost penalties. To address this, a Fault Detection and Diagnostic (FDD) tool was developed to automate data analysis and identify operational faults such as suboptimal outdoor temperature sensor placement, misconfigured outdoor air reset (OAR) curves, excess boiler cycling, and domestic hot water (DHW) setpoint errors. By comparing pre- and post-implementation periods and applying engineering models, the tool quantifies energy savings and reduces manual analysis time by over 90%. Testing on over 100 monitored sites and a targeted subset of 12 buildings showed an average 11% energy savings from remote optimization; further validation across 19 OAR curve changes confirmed the tool’s accuracy, predicting actual savings within ±5% for most cases. Simple payback can be under three years for many multifamily buildings, though rising hardware, labor, and fuel costs create uncertainties, and decarbonization goals increasingly shift focus to electrification. The FDD tool remains invaluable for optimizing existing boilers, enhancing future electrification measures, and adapting to new technologies by refining building load estimates. In doing so, it supports both near-term efficiency and long-term transitions to low-carbon alternatives, ensuring buildings achieve substantial cost and energy benefits throughout their system lifecycles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

R.U.N. Motion VR Boots: Realistic Unimpeded Natural (RUN) Motion Boots for VR gaming in the comfort of your home

Virtual reality (VR) gaming has experienced increasingly widespread adoption in recent years largely due to the development of affordable, consumer-grade headsets equipped with high quality, miniature displays and compact sensors for motion tracking. These devices are now able to provide users with immersive experiences that far surpass what traditional video games can achieve. However, despite these technological strides, a fundamental limitation remains: VR users are unable to move freely in their physical environment without the risk of colliding with real-world obstacles and hazards. This safety concern significantly restricts the level of immersion and natural movement possible in VR gaming.

42 ENGINEERING↗

The Impact of Operated Window Shading on Visual Comfort, Non-Visual Health, and Energy Demand from Electric Lighting

This paper introduces a simulation-based workflow to assess annual circadian lighting performance, glare risk and energy demand for an array of seated view positions under operated shading and electric lighting conditions. This workflow uses a combination of 9-band and 81-band simulations to represent daylight and electric lighting respectively. Annual daylight-driven calculations rely on a python-based code provided in the LARK simulation engine which was used to run 180-degree high dynamic range (HDR) renderings with 9-bands of spectral resolution. The results reveal the impact of shading systems on equivalent melanopic lux (EML) and daylight glare probability (DGP) over time and the energy demand (kWh) from electric lighting systems to supplement eye-level recommendations from the WELL v2 Building Standard.

Rockcastle, Siobhan↗

Concept to comfort-condition subjects wearing restrictive clothing

Heat exchanger maintains a desirable thermal balance in a subject wearing restrictive clothing. A grid of high thermal conductance fibers, in contact with the skin, transfers heat to or from the skin surface by means of a system of ducts, carrying the transfer fluid which is maintained at a controlled temperature.

Tucker, E. M.↗