Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CLOCK”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Deep Space Atomic Clock Technology Demonstration Mission Results

The Deep Space Atomic Clock (DSAC), a NASA Technology Demonstration Mission, was launched into low-Earth orbit on June 25, 2019 as a hosted payload aboard General Atomics’ Orbital Test Bed (OTB) spacecraft. The DSAC mission has been conducting a two-year demonstration of a mercury ion atomic clock to characterize its space-based performance and to validate its utility for deep space navigation and radio science. Analysis of the collected data using JPL’s GIPSY-OASIS software has shown DSAC’s AD at one-day to be near 310-15; much better than required AD of 210-14. Such low spacecraft clock errors will enable one-way radiometric tracking data with precision equivalent to or better than current-day two way tracking data, allowing a shift to a more efficient and flexible one-way deep space navigation architecture. To verify this, an analog deep space navigation experiment was performed using JPL’s operational navigation software (Monte). The experiment recovered orbit solutions with reduced data sets and geometric variations that are more representative of deep space missions, and showed that orbit determination using DSAC derived data is on par with more traditional two-way datatypes. As a technology demonstrator, DSAC’s development focus has been on maturing the mercury ion trap clock technology rather than achieving the smallest size, weight, and power (SWaP). Over the course of DSAC’s development the project has identified numerous improvements that could be made to significantly reduce SWaP for DSAC’s next version. Indeed, DSAC-2 was recently selected by NASA for further demonstration on the VERITAS mission to Venus. This work will review the DSAC technology, mission, and results from its two-year mission.

Wang, Rabi↗

Using Pulsars For Clock Steering and Time Transfer

As we prepare for extended missions on the Moon and in cislunar space, precise time synchronization between lunar and terrestrial clocks becomes increasingly critical for navigation, communication, and science measurements. One promising technique is the use of millisecond pulsars, which are highly magnetized, rapidly rotating neutron stars emitting beams of electromagnetic radiation. These celestial clocks offer extraordinary stability and precision, with rotational periods ranging from about 1 to 10 milliseconds and timing stability comparable to laboratory atomic clocks on Earth. Pulsars can provide a common time reference for clock comparisons, allowing time transfer independent of a communications link.

Spacecraft Communications, Command and Tracking↗

Gm-C filter and multi-phase clock circuit

Described herein is a power-efficient Gm-C filter, wherein the Gm-C filter includes several operational transconductance amplifiers (OTAs). In an example, at least two of the OTAs share a common bias current. Further, output of one of the OTAs is used to bias another one of the OTAs. Also described herein is a power-efficient clock generator circuit that is configured to output non-overlapping clock signals. The clock generator circuit includes a ring oscillator circuit, which includes several inverter stages. The clock generator circuit is well-suited for controlling operation of switches.

42 ENGINEERING↗

Precision Clocks in Space and alpha-Variations

Important developments of both in theoretical and observational cosmology have fueled considerable interest in searches for variations of the fine structure constant. Experimentally, Webb et. al. have found evidence for a cosmological variation of the fine structure constant through an analysis of the absorption lines in galactic halos from quasar-emitted light. Recently developed small ion atomic clocks enable Solar System tests for equivalence principle (EP) violating (alpha)-variations by way of rate-comparisons of three ultra-stable atomic clocks near-to and far-from the sun where gravitational red-shift changes are more than 10(exp 4) larger than in low Earth orbit. No space tests of the EP have been made in nearly 30 years, since the GP-A hydrogen maser reached a 10,000 km apogee confirming EP red-shift predictions ~1 part in 10(exp 4). Today's small ion clocks, nearly 100x more stable and 100x smaller then the GP-A H-maser, could probe for EP violating scalar fields near the sun for mission costs comparable to low Earth orbiters and improve the GP-A sensitivity by 5 to 6 orders of magnitude.

(alpha)-variation↗

Probing many-body interactions in an optical lattice clock

We present a unifying theoretical framework that describes recently observed many-body effects during the interrogation of an optical lattice clock operated with thousands of fermionic alkaline earth atoms. The framework is based on a many-body master equation that accounts for the interplay between elastic and inelastic p-wave and s-wave interactions, finite temperature effects and excitation inhomogeneity during the quantum dynamics of the interrogated atoms. Solutions of the master equation in different parameter regimes are presented and compared. It is shown that a general solution can be obtained by using the so called Truncated Wigner Approximation which is applied in our case in the context of an open quantum system. We use the developed framework to model the density shift and decay of the fringes observed during Ramsey spectroscopy in the JILA {sup 87}Sr and NIST {sup 171}Yb optical lattice clocks. The developed framework opens a suitable path for dealing with a variety of strongly-correlated and driven open-quantum spin systems. -- Highlights: •Derived a theoretical framework that describes many-body effects in a lattice clock. •Validated the analysis with recent experimental measurements. •Demonstrated the importance of beyond mean field corrections in the dynamics.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Circadian clock control of ribosome composition promotes rhythmic translation and termination fidelity

Ribosome composition is dynamic, shifting with cell state and stress, but whether it varies with circadian time is unknown. Here, we uncover circadian clock-driven changes in ribosome composition in Neurospora crassa . Mass spectrometry of ribosomes across circadian time identified six ribosomal proteins and one associated factor under clock control. Rhythms in eL31 abundance were validated in purified ribosomes, and deletion of el31 disrupted translation rhythms in nearly half of rhythmically translated mRNAs. N. crassa eL31 promotes circadian control of translation termination and impacts elongation fidelity while maintaining Mg homeostasis, a key determinant of translational accuracy. These findings reveal that the circadian clock reprograms ribosome composition to orchestrate rhythmic translation and fidelity, temporally expanding the proteome beyond the static genome to align cellular function with time of day.

circadian clock↗

Invited Review Article: The statistical modeling of atomic clocks and the design of time scales

I will show how the statistical models that are used to describe the performance of atomic clocks are derived from their internal design. These statistical models form the basis for time scales, which are used to define international time scales such as International Atomic Time and Coordinated Universal Time. These international time scales are realized by ensembles of clocks at national laboratories such as the National Institute of Standards and Technology, and I will describe how ensembles of atomic clocks are characterized and managed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A low phase noise microwave frequency synthesis for a high-performance cesium vapor cell atomic clock

We report the development, absolute phase noise, and residual phase noise characterization of a 9.192 GHz microwave frequency synthesis chain devoted to be used as a local oscillator in a high-performance cesium vapor cell atomic clock based on coherent population trapping (CPT). It is based on frequency multiplication of an ultra-low phase noise 100 MHz oven-controlled quartz crystal oscillator using a nonlinear transmission line-based chain. Absolute phase noise performances of the 9.192 GHz output signal are measured to be −42, −100, −117 dB rad{sup 2}/Hz and −129 dB rad{sup 2}/Hz at 1 Hz, 100 Hz, 1 kHz, and 10 kHz offset frequencies, respectively. Compared to current results obtained in a state-of-the-art CPT-based frequency standard developed at LNE-SYRTE, this represents an improvement of 8 dB and 10 dB at f = 166 Hz and f = 10 kHz, respectively. With such performances, the expected Dick effect contribution to the atomic clock short term frequency stability is reported at a level of 6.2 × 10{sup −14} at 1 s integration time, that is a factor 3 higher than the atomic clock shot noise limit. Main limitations are pointed out.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Numerical quantum clock simulations for measuring tunneling times

Here, we numerically study two methods of measuring tunneling times using a quantum clock. In the conventional method using the Larmor clock, we show that the Larmor tunneling time can be shorter for higher tunneling barriers. In the second method, we study the probability of a spin-flip of a particle when it is transmitted through a potential barrier including a spatially rotating field interacting with its spin. According to the adiabatic theorem, the probability depends on the velocity of the particle inside the barrier. It is numerically observed that the probability increases for higher barriers, which is consistent with the result obtained by the Larmor clock. By comparing outcomes for different initial spin states, we suggest that one of the main causes of the apparent decrease in the tunneling time can be the filtering effect occurring at the end of the barrier.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Optical telecommunications-band clock based on neutral titanium atoms

Here, we propose an optical clock based on ultranarrow transitions in neutral titanium, which exhibit small blackbody radiation and quadratic Zeeman shifts and have wavelengths in the S-, C-, and L-telecommunications fiber bands, allowing for integration with robust laser technology. We calculate relevant properties using a high-precision relativistic hybrid method that combines configuration interaction and coupled-cluster approaches. To identify magic wavelengths, we have completed the largest-to-date direct dynamical polarizability calculations. Finally, we identify challenges that arise from magnetic dipole-dipole interactions and describe an approach to overcome them. A telecommunications-band atomic frequency standard will aid the deployment of optical clock networks and clock comparisons over long distances.

74 ATOMIC AND MOLECULAR PHYSICS↗

Collisionally induced atomic clock shifts and correlations

We develop a formalism to incorporate exchange symmetry considerations into the calculation of collisional frequency shifts for atomic clocks using a density-matrix formalism. The formalism is developed for both fermionic and bosonic atomic clocks. Numerical results for a finite-temperature {sup 87}Sr {sup 1}S{sub 0} (F=9/2) atomic clock in a magic wavelength optical lattice are presented.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Noise in state of the art clocks and their impact for fundamental physics

In this paper a review of the use of advanced atomic clocks in testing the fundamental physical laws will be presented. Noise sources of clocks will be discussed, together with an outline their characterization based on current models. The paper will conclude with a discussion of recent attempts to reduce the fundamental, as well as technical noise in atomic clocks.

noise state-of-the-art clocks fundamental physics↗

One-liter Hg ion clock for space and ground applications

We describe the development of a small Hg ion clock suitable for space use. A small clock occupying 1-2 liters volume and producing stability of 10 to the power negative twelve, divided by square root pi would significantly advance the state of space-qualified atomic clocks. Based on recent measurements, this technology should produce long-term stability as good as 10 to the power negative fifteen.

ion clock↗

The Deep Space Atomic Clock Mission

The Deep Space Atomic Clock (DSAC) mission will demonstrate the space flight performance of a small, low-mass, high-stability mercury-ion atomic clock with long term stability and accuracy on par with that of the Deep Space Network. The timing stability introduced by DSAC allows for a 1-Way radiometric tracking paradigm for deep space navigation, with benefits including increased tracking via utilization of the DSN's Multiple Spacecraft Per Aperture (MSPA) capability and full ground station-spacecraft view periods, more accurate radio occultation signals, decreased single-frequency measurement noise, and the possibility for fully autonomous on-board navigation. Specific examples of navigation and radio science benefits to deep space missions are highlighted through simulations of Mars orbiter and Europa flyby missions. Additionally, this paper provides an overview of the mercury-ion trap technology behind DSAC, details of and options for the upcoming 2015/2016 space demonstration, and expected on-orbit clock performance.

autonomy↗

The Deep Space Atomic Clock: Ushering in a New Paradigm for Radio Navigation and Science

The Deep Space Atomic Clock (DSAC) mission will demonstrate the on-orbit performance of a high-accuracy, high-stability miniaturized mercury ion atomic clock during a year-long experiment in Low Earth Orbit. DSAC's timing error requirement provides the frequency stability necessary to perform deep space navigation based solely on one-way radiometric tracking data. Compared to a two-way tracking paradigm, DSAC-enabled one-way tracking will benefit navigation and radio science by increasing the quantity and quality of tracking data. Additionally, DSAC also enables fully-autonomous onboard navigation useful for time-sensitive situations. The technology behind the mercury ion atomic clock and a DSAC mission overview are presented. Example deep space applications of DSAC, including navigation of a Mars orbiter and Europa flyby gravity science, highlight the benefits of DSAC-enabled one-way Doppler tracking.

atomic clock↗

Progress on Small Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approx.1-2x10-(sup 1)(sup 3) at 1 second, averaging to 10-(sup 1)? at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1-2x10-(sup 1)(sup 3) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for over three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow approx. 400 deg C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

positioning↗

Compact Microwave Mercury Ion Clock for Space Applications

We have recently completed a breadboard ion-clock physics package based on Hg ions shuttled between a quadrupole and a 16-pole rf trap. With this architecture we have demonstrated short-term stability approximately 1 - 2 x 10(exp -13) at 1 second, averaging to 10(exp -15) at 1 day. This development shows that H-maser quality stabilities can be produced in a small clock package, comparable in size to an ultra-stable quartz oscillator required for holding 1 - 2 x 10(exp -13) at 1 second. This performance was obtained in a sealed vacuum configuration where only a getter pump was used to maintain vacuum. The vacuum tube containing the traps has now been under sealed vacuum conditions for nearly three years with no measurable degradation of ion trapping lifetimes or clock short-term performance. We have fabricated the vacuum tube, ion trap and UV windows from materials that will allow an approximately 400 C bake-out to prepare for tube seal-off. This approach to the vacuum follows the methods used in flight vacuum tube electronics, such as flight TWTA's where tube operation lifetime and shelf life of up to 15 years is achieved.

Atomic Clock↗

A Novel Photonic Clock and Carrier Recovery Device

In high-speed fiber-optic communications systems, the ability to recover the clock from the incoming random data is essential. The recovered clock must be in precise synchronism with the incoming data and is used in further signal processing systems, such as regenerative repeaters, time division switching systems, and demultiplexers. A high-speed photonic clock regenerator is described.

photonic↗