Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 181 records · Page 10

Enhancement of anion-exchange chromatography of DNA using compaction agents

The use of adsorptive chromatography for preparative nucleic acid separations is often limited by low capacity. The possibility that the adsorbent surface area sterically accessible to nucleic acid molecules could be increased by reducing their radius of gyration with compaction agents has been investigated. The equilibrium adsorption capacity of Q Sepharose anion-exchange matrix for plasmid DNA at 600 mM NaCl was enhanced by up to ca. 40% in the presence of 2.5 mM spermine. In addition, compaction agent selectivity has been demonstrated. Spermine, for example, enhances the adsorption of both plasmid and genomic DNA, spermidine enhances binding only of plasmid, and hexamine cobalt enhances only the binding of genomic DNA. Compaction may be generally useful for enhancing adsorptive separations of nucleic acids.

NASA Discipline Environmental Health↗

Effect of modulator sorption on gradient shape in ion-exchange chromatography

Mobile phase additives, or modulators, are used in gradient elution chromatography to facilitate separation and reduce separation time. The modulators are usually assumed to be linearly adsorbed or unadsorbed. Here, the consequences of nonlinear modulator adsorption are examined for ion-exchange gradient elution through a series of simulations. Even when the buffer salt is identical to the modulator salt, gradient deformation is observed; the extent of deformation increases as the volume of the feed is increased. When the modulator salt is different from the buffer salt, unusual effects are observed, and the chromatograms are quite different from those predicted by classical gradient elution theory. In particular, local increases in the buffer concentration are found between feed bands, and serve to improve the separation. These effects become more pronounced as the feed volume increases, and could therefore prove valuable in preparative applications.

NASA Discipline Life Support Systems↗

Determination of anionic surfactants during wastewater recycling process by ion pair chromatography with suppressed conductivity detection

A direct approach utilizing ion pairing reversed-phase chromatography coupled with suppressed conductivity detection was developed to monitor biodegradation of anionic surfactants during wastewater recycling through hydroponic plant growth systems and fixed-film bioreactors. Samples of hydroponic nutrient solution and bioreactor effluent with high concentrations (up to 120 mS electrical conductance) of inorganic ions can be analyzed without pretreatment or interference. The presence of non-ionic surfactants did not significantly affect the analysis. Dynamic linear ranges for tested surfactants [Igepon TC-42, ammonium lauryl sulfate, sodium laureth sulfate and sodium alkyl (C10-C16) ether sulfate] were 2 to approximately 500, 1 to approximately 500, 2.5 to approximately 550 and 3.0 to approximately 630 microg/ml, respectively.

NASA Program Advanced Human Support Technology↗

Analysis of water from the Space Shuttle and Mir Space Station by ion chromatography and capillary electrophoresis

Drinking water and condensate samples collected from the US Space Shuttle and the Russian Mir Space Station are analyzed routinely at the NASA-Johnson Space Center as part of an ongoing effort to verify water quality and monitor the environment of the spacecraft. Water quality monitoring is particularly important for the Mir water supply because approximately half of the water consumed is recovered from humidity condensate. Drinking water on Shuttle is derived from the fuel cells. Because there is little equipment on board the spacecraft for monitoring the water quality, samples collected by the crew are transported to Earth on Shuttle or Soyuz vehicles, and analyzed exhaustively. As part of the test battery, anions and cations are measured by ion chromatography, and carboxylates and amines by capillary electrophoresis. Analytical data from Shuttle water samples collected before and after several missions, and Mir condensate and potable recovered water samples representing several recent missions are presented and discussed. Results show that Shuttle water is of distilled quality, and Mir recovered water contains various levels of minerals imparted during the recovery processes as designed. Organic ions are rarely detected in potable water samples, but were present in humidity condensate samples.

NASA Discipline Environmental Health↗

Improved resolution of hydrocarbon structures and constitutional isomers in complex mixtures using Gas Chromatography-Vacuum Ultraviolet-Mass Spectrometry (GC-VUV-MS)

Understanding the composition of complex hydrocarbon mixtures is important for environmental studies in a variety of fields, but many prevalent compounds cannot be confidently identified using traditional gas chromatography-mass spectrometry (GC-MS) techniques. This work uses vacuum-ultraviolet (VUV) ionization to elucidate the structures of a traditionally"unresolved complex mixture" by separating components by GC retention time, tR, and mass-to-charge ratio, m/Q, which are used to determine carbon number, NC, and the number of rings and double bonds, NDBE. Constitutional isomers are resolved based on tR, enabling the most complete quantitative analysis to date of structural isomers in an environmentally-relevant hydrocarbon mixture. Unknown compounds are classified in this work by carbon number, degree of saturation, presence of rings, and degree of branching, providing structural constraints. The capabilities of this analysis are explored using diesel fuel, in which constitutional isomer distribution patterns are shown to be reproducible between carbon numbers and follow predictable rules. Nearly half of the aliphatic hydrocarbon mass is shown to be branched, suggesting branching is more important in diesel fuel than previously shown. The classification of unknown hydrocarbons and the resolution of constitutional isomers significantly improves resolution capabilities for any complex hydrocarbon mixture.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Molecular Weight Distribution Analysis of Pyrolysis Oils by Gel Permeation Chromatography

Comprehensive analysis of the molecular weight distribution of raw and catalytic fast pyrolysis oils derived from biomass remains a key technical hurdle to understanding oil quality as it relates to downstream use and multiple methods may be necessary to accurately represent all components present. Here, we report the molecular weight distribution metrics of fast pyrolysis (FP) and catalytic fast pyrolysis (CFP) oils as determined by gel permeation chromatography (GPC) combined with UV-diode array (UV), differential refractive index (RI), and multi-angle laser light scattering (MALS) detection. The measured molar mass distributions revealed that FP oil consisted of a higher proportion of larger products relative to the low molecular weight products contained in the CFP oil. GPC/RI and UV methods showed FP oil to have higher weight-average molecular weight (Mw) and number-average molecular weight (Mn) than CFP oil based on elution time. However, GPC/MALS, determined the two oils to have similar overall molecular weight distribution metrics (Mw and Mn) and yielded values significantly higher than those determined by RI and UV detectors relative to external standards. Overall, the use of a multiple detection GPC method could enable a more accurate comparison and determination of true molecular weight metrics of bio-oils.

BIOMASS FUELS↗

Extremely Highly Volume Reduction of r-Cs Contaminated Wastes by Using Ion Exchanging Chromatography - 18248

Calcination or melting processes remove radio-Cs from contaminated soil and incineration ashes when appropriate amounts of CaO and CaCl{sub 2} are added. The byproducts from the heat treatment system are concentrated water-soluble alkali chlorides, mainly composed of KCl with small amounts of CsCl contaminated with radio-Cs. These methods may effectively reduce the volume of wastes to as much as 1/100. the initial volume in the best condition. Further volume reduction from the concentrated salts is investigated by using ion-exchange chromatography of transitional metal ferrocyanides. Copper ferrocyanide (CuFeCN) is chosen as the optimum salt as it has a high ion selectivity coefficient of 2.75 x 10{sup 4} and ion-exchange capacity of 0.29 mmol/g. This CuFeCN is supported by porous silica gel carrier and is used in the ion-exchange column. A solution containing 1.34 M of KCl and 1.34 mM of CsCl labelled with Cs-137 is flowed through the column. A maximum of 80% absorbing capacity of CuFeCN and 99.9% removal efficiency of radio-Cs are achieved. Because the used adsorbent contains a high concentration of radio-Cs, it must be solidified and scattering or leaching out must be prevented. Therefore, 10 g of the used adsorbent is mixed with 20 g of meta-kaolin, 7 g of NaOH, and 18 g of water and the 'geopolymer' mixture is solidified under room temperature. No ratio-Cs release is detected from this solidified material when it is immersed in sea water or pure water for a month at 40 deg. C. Using the proposed method, the final volume of the waste could be reduced to approximately 1/10,000. the initial volume. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

A Numerical Model of Exchange Chromatography Through 3D Lattice Structures

Rapid progress in the development of additive manufacturing technologies is opening new opportunities to fabricate structures that control mass transport in three dimensions across a broad range of length scales. We describe a structure that can be fabricated by newly available commercial 3D printers. It contains an array of regular three-dimensional flow paths that are in intimate contact with a solid phase, and thoroughly shuffle material among the paths. We implement a chemically reacting flow model to study its behavior as an exchange chromatography column, and compare it to an array of one-dimensional flow paths that resemble more traditional honeycomb monoliths. A reaction front moves through the columns and then elutes. Here, the front is sharper at all flow rates for the structure with three-dimensional flow paths, and this structure is more robust to channel width defects than the one-dimensional array.

42 ENGINEERING↗

Effects of processing on the efficacy and metabolites of Cistanche tubulosa using ultra‐performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry

Abstract Cistanche tubulosa (CT), a well‐known traditional Chinese medicine, has always been processed with rice wine for the treatment of kidney‐yang deficiency syndrome (KYDS) since time immemorial. To explore the effect of processing on the efficacy and metabolites of CT in vivo , a comprehensive method using ultra‐performance liquid chromatography coupled with quadrupole time‐of‐flight mass spectrometry was established for the analysis of the altered endogenous metabolites in response to the intervention of the raw and processed CT in KYDS model and the metabolites of the absorbed compounds in rats after gastric perfusion. It was shown that CT could improve KYDS, and the effect of the processed product was more significant. A total of 47 differential metabolites were identified in urine. Pathway analysis proved that purine metabolism; alanine, aspartate, and glutamate metabolism; and citrate cycle were the main pathways. Furthermore, 53 prototypes and 48 metabolites have been detected in rats. This was the first systematic research focus on the metabolites of raw and processed CT in vivo , which could provide a scientific basis for explaining the increasing efficiency of the processed CT. Moreover, it provides a valuable strategy for analyzing the chemical components and metabolites of other TCM prescriptions.

Lei, Huibo↗

Chiral Separation of G-type Chemical Warfare Nerve Agents via Analytical Supercritical Fluid Chromatography: SEPARATION OF G-TYPE CHEMICAL WARFARE NERVE AGENTS

Chemical warfare nerve agents (CWNAs) are extremely toxic organophosphorus compounds that contain a chiral phosphorus center. Undirected synthesis of G-type CWNAs produces stereoisomers of tabun, sarin, soman, and cyclosarin (GA, GB, GD, and GF, respectively). Analytical-scale methods were developed using a supercritical fluid chromatography (SFC) system in tandem with a mass spectrometer for the separation, quantitation, and isolation of individual stereoisomers of GA, GB, GD, and GF. Screening various chiral stationary phases (CSPs) for the capacity to provide full baseline separation of the CWNAs revealed that a Regis WhelkO1 (SS) column was capable of separating the enantiomers of GA, GB, and GF, with elution of the P(+) enantiomer preceding elution of the corresponding P(–) enantiomer; two WhelkO1 (SS) columns had to be connected in series to achieve complete baseline resolution. The four diastereomers of GD were also resolved using two tandem WhelkO1 (SS) columns, with complete baseline separation of the two P(+) epimers. A single WhelkO1 (RR) column with inverse stereochemistry resulted in baseline separation of the GD P(–) epimers. The analytical methods described can be scaled to allow isolation of individual stereoisomers to assist in screening and development of countermeasures to organophosphorus nerve agents

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Centrifugal‐driven, reduced‐dimension, planar chromatography

Abstract A fundamental problem with efficiency in capillary action driven planar chromatography results from diminishing flow rates as development proceeds, giving rise to molecular diffusion related band dispersion for most sample types. Overpressure and electrokinetic means to speed flow have been used successfully in TLC. We explore the use of centrifugal force (CF) to drive flow for reduced‐dimension planar platforms (ultra‐TLC, low micrometer features, and nano‐TLC, nanoscale features). The silicon wafer platforms have two forms of continuous 2D arrays created by either photolithography or metal dewetting followed by deep reactive ion etching and coated with porous SiO 2 . The flow pattern is unusual with co‐planar flows above and within the arrays. The effects of parameters such as spin rate, solvent type, and surface character on flow rates is established and can be substantially greater than capillary action flow. Using fluorescent dyes, we investigate retardation factors and chromatographic plate height; the latter falls in the low to sub‐micrometer range. To the best of our knowledge, we demonstrate the first analytical separations performed in pillar arrays using CF to augment solvent flow.

Strickhouser, Rachel B.↗

Chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic ( Allium ampeloprasum L.) by liquid chromatography tandem mass spectrometry

Abstract Introduction Giant garlic is a functional food that contains different kinds of bioactive molecules with beneficial effects on chronic noncommunicable diseases like diabetes and cardiovascular conditions. Considering biosynthesis pathways, abundance, and biological activity, alliin and S‐allyl‐cysteine were used as chemical markers of organosulphur compounds present in giant garlic. Objective To establish a chemometric optimisation of pressurised liquid extraction for the determination of alliin and S‐allyl‐cysteine in giant garlic by liquid chromatography tandem mass spectrometry (LC–MS/MS). Methodology Samples were blanched (ca. 90°C for 10 min) to inactivate alliinase and γ‐glutamyl transpeptidase enzymes and then freeze‐dried. Chemometric optimisation was performed via response surface methodology based on central composite design (CCD). Organosulphur compound yields were determined applying a validated LC–MS/MS method in multiple reaction monitoring (MRM) mode using the following transitions: for alliin m/z 178 → 74 and for S‐allyl‐cysteine m/z 162 → 41. Results According to CCD results, under constant conditions of pressure (1500 psi) and time (20 min), the optimal conditions for pressurised liquid extraction of alliin and S‐allyl‐cysteine were 70.75 and 68.97% v/v of ethanol in extraction solvent and 76.45 and 98.88°C as extraction temperature, respectively. Multiple response optimisation for the simultaneous extraction of both organosulphur compounds was established via desirability function. Under these conditions, 2.70 ± 0.27 mg g −1 dry weight (DW) of alliin and 2.79 ± 0.22 mg g −1 DW of S‐allyl‐cysteine were extracted. Conclusions These results clearly demonstrated that pressurised liquid extraction is an efficient green technique to extract bioactive organosulphur compounds from giant garlic. Extraction yields were significantly ( p < 0.05) higher than those obtained with conventional ultra‐turrax extraction.

Peterssen‐Fonseca, Darlene↗

Identification of Blue Discoloration in PBX 9404 using Ultrahigh Pressure Liquid Chromatography with Quadrupole Time-of-Flight Mass Spectrometry

PBX 9404, composed of 94 wt% HMX (1,3,5,7-Tetranitro-1,3,5,7-tetrazoctane), 3 wt% NC (nitrocellulose), 2.9 wt% CEF (tris(beta-chloroethyl) phosphate) and 0.1 wt% DPA (diphenylamine), has often been observed with a slight to entire blue discoloration of the manufactured prills. This blue discoloration has been observed since the formulation development of PBX 9404 in the late 1950s. In order to determine the source of the blue discoloration in PBX 9404, ultraviolet/visible (UV/Vis) absorbance of PBX 9404 and two potential candidates for the discoloration, p-nitrosodiphenylamine (p-NDPA) and N-nitrosodiphenylamine (N-NDPA) were evaluated. An absorbance band at 590 nm in PBX 9404 sample was attributed to the blue discoloration while p-NDPA and N-NPDA had different absorbance bands. Using the knowledge gained from the UV/Vis analysis, a semi-targeted approach using ultrahigh pressure liquid chromatography coupled to UV/Vis detector and quadrupole time of flight mass spectrometry (UHPLC-UV/Vis-QTOF) was implemented. Investigating the UHPLC-UV/Vis-QTOF chromatograms at a wavelength of 590 nm, a single compound was tentatively identified as being the source of the blue discoloration. Targeted tandem mass spectrometry (MS/MS) on the compound and subsequent analysis indicated that 4,4 -{[4-(Phenylimino)-2,5-cyclohexadien-1-ylidene]methylene}bis(N-phenylaniline), also known as Spirit Blue Base, was the source of the blue discoloration, which was confirmed using a standard. Here, a theory on the formation of Spirit Blue Base in PBX 9404 involving DPA, nitric acid (HNO 3 ) / nitrogen oxide(s) NO x , and formaldehyde is proposed.

36 MATERIALS SCIENCE↗

Liquid Chromatography Mass Spectrometry study of eutectic bis(2,2-dinitropropyl) acetal/formal

This study is the first attempt to document methodology development undergone using liquid chromatography tandem quadrupole time of flight mass spectrometry (LC-QTOF) to investigate degradation products of eutectic bis(2,2-dinitropropyl) acetal/formal nitroplasticizer (called NP here). Method properties investigated are: desolvation temperature (°C) and spray voltage (V) of the electrospray ionization source, and the development of an acetone system rinse to prevent any residual contamination between sample injections. Details are given on why it is essential to investigate method optimization with changes shown in MS/MS analysis in addition to MS results. Trends in MS/MS analytic results reveal important relationships between baseline and aged materials. In addition to verification of previously proposed fragments, insights offered by this newly developed methodology will also identify new degradation products and shed light on the complexity of NP degradation chemistry.

36 MATERIALS SCIENCE↗

Trace Compound Analysis in TATB by Liquid Chromatography coupled with Spectroscopic and Spectrometric Detection

Accurate quantitation of 1,3,5-triamino-2,4,6-trinitrobenzene (TATB) is important because of its strategic use as an energetic material. A purity determination is also needed for the proper assessment of performance. A fast and sensitive method has been developed to measure the purity of TATB in polymer-bonded materials. The target material is extracted with DMSO, and the extract is separated on a reversed-phase chromatography column. The column effluent is monitored by diode array detection (DAD) at 354 nm. The characteristic UV-Vis response and retention time identify the individual components when compared to pure compound standards. The chemical structures of compounds with no pure standards available have been determined by high-resolution mass spectrometry (MS) and MS/MS. The major component, TATB, along with 1-chloro-3,5-dinitro-2,4,6-triaminobenzene (T4A) and mono-benzofuroxan (FX1) were quantitated directly from pure compound standards. Several trace concentration components, mono-benzofurazan (F1), 1-bromo-3,5-dinitro-2,4,6-triaminobenzene (Br-T4A), 2,4,6-triamino-1-nitroso-3,5-dinitrobenzene (MN-TATB), 2,4,6-triamino-1-hydroxyl-3,5-dinitrobenzene (HO-TATB), and 2,4,6-triamino-1-nitrile-3,5-dinitrobenzene (Nitrile-TATB) were also detected and structures verified via MS/MS. Approximate concentrations were determined using calibrations from standards of similar structures. Additional trace components were also detected by MS. Contained herein are the results of analyses of TATB-based materials characterized for polymer-bonded formulations compared to different preparations of TATB. The accuracy, details, and process of developing this method are reported here.

36 MATERIALS SCIENCE↗